Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pulse”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Modeling of Initial Detonation-mode Acceleration in Pulsed Plasma and Magnetoplasmadynamic Thrusters

Gas-fed electromagnetic pulsed plasma accelerators operate by discharging electrical energy into a gas, subsequently ionizing and electromagnetically accelerating propellant. Many efforts to model pulsed accelerators have assumed that the discharge is either short and completely transient, accelerating the gas like a shock by entraining it in a moving current sheet, or that the discharge is relatively long, establishing a stable quasi-steady current distribution through which plasma flows and is accelerated. This idealization encounters problems when thrusters possess some qualities associated with both short and long-pulse-length thrusters. To capture all possible scenarios, a model is presented based upon the idea that all pulsed plasma accelerators first form an accelerating current sheet (detonation mode accelerator) and then, depending upon the pulse length and the manner in which the plasma reaches the thruster exit, it can transition to the quasi-steady acceleration configuration (deflagration mode accelerator). In the present work the detonation mode is investigated, varying controllable parameters to determine their effects on the plasma acceleration process. The primary driver affecting current sheet acceleration is the amount of gas that the plasma encounters and entrains as it moves towards the thruster exit. The amount of neutral gas the plasma entrains affects the time it takes the plasma to reach the end of the accelerator and changes the corresponding electrical discharge parameters at the end of detonation mode acceleration.

Polzin, Kurt A.↗

A Screening Method Using Pulsed-Power Combined with Infrared Imaging to Detect Pattern Defects in Bulk Metal Foil or Thin Film Resistors

Bulk metal foil and thin film resistors occasionally contain localized defects within the etched resistor pattern. Common defects of this type include in-line constrictions referred to as notches, unremoved resistor material bridges between adjacent pattern lines, and embedded non-conductive particles in the resistor material. Such defects are prone to fracture due to thermomechanical fatigue during powered operation, especially power cycling, resulting in positive resistance change and open circuit failure modes. Common screening methods of optical microscopy, short time overload power tests (e.g., 6.25x rated power for 5 seconds) and burn-in (e.g., 1.5x rated power for 100 hours) are useful, but they are not always effective at removing devices with such defects. An improved method has been developed to screen for localized resistor pattern defects. The method involves the application of brief, high power electrical pulses at a low duty cycle while inspecting the resistor with a high resolution, high speed infrared camera. The following test conditions were found to be suitable for this purpose: 6.25x rated power, 1 to 5 pulses, 50 ms pulse width and 10% duty cycle. During the power pulsing, localized constrictions in the resistor pattern are identifiable as hot spots via the infrared camera. Reject criteria can be established based on observations of hot spots. To assess its effectiveness, a total of two hundred eighty (280) surface mount foil resistors (40 each from 7 different lots) were screened using this infrared technique. The screening identified twenty-nine (29) resistors with significant hot spots in the resistor pattern. All 280 resistors were then subjected to an industry standard 10,000 hour life test at 1x rated power at 70°C with power cycled for 90 minutes on and 30 minutes off. During life testing, three resistors exhibited positive resistance change failure mode. All three failures were due to thermomechanical fatigue failure of localized bridge defects at the locations identified via infrared screening. The results of this evaluation illustrate the benefits of the pulsed-power infrared detection screening technique to identify reliability suspect foil or thin film resistors that may escape common screening methods.

screening↗

A Screening Method Using Pulsed-Power Combined with Infrared Imaging to Detect Pattern Defects in Bulk Metal Foil or Thin Film Resistors

Bulk metal foil and thin film resistors occasionally contain localized defects within the etched resistor pattern. Common defects of this type include in-line constrictions referred to as notches, unremoved resistor material bridges between adjacent pattern lines, and embedded non-conductive particles in the resistor material. Such defects are prone to fracture due to thermomechanical fatigue during powered operation, especially power cycling, resulting in positive resistance change and open circuit failure modes. Common screening methods of optical microscopy, short time overload power tests (e.g., 6.25x rated power for 5 seconds) and burn-in (e.g., 1.5x rated power for 100 hours) are useful, but they are not always effective at removing devices with such defects. An improved method has been developed to screen for localized resistor pattern defects. The method involves the application of brief, high power electrical pulses at a low duty cycle while inspecting the resistor with a high resolution, high speed infrared camera. The following test conditions were found to be suitable for this purpose: 6.25x rated power, 1 to 5 pulses, 50 ms pulse width and 10% duty cycle. During the power pulsing, localized constrictions in the resistor pattern are identifiable as hot spots via the infrared camera. Reject criteria can be established based on observations of hot spots. To assess its effectiveness, a total of two hundred eighty (280) surface mount foil resistors (40 each from 7 different lots) were screened using this infrared technique. The screening identified twenty-nine (29) resistors with significant hot spots in the resistor pattern. All 280 resistors were then subjected to an industry standard 10,000 hour life test at 1x rated power at 70°C with power cycled for 90 minutes on and 30 minutes off. During life testing, three resistors exhibited positive resistance change failure mode. All three failures were due to thermomechanical fatigue failure of localized bridge defects at the locations identified via infrared screening. The results of this evaluation illustrate the benefits of the pulsed-power infrared detection screening technique to identify reliability suspect foil or thin film resistors that may escape common screening methods.

screening↗

The NANOGrav 12.5 yr Data Set: The Frequency Dependence of Pulse Jitter in Precision Millisecond Pulsars

Low-frequency gravitational-wave experiments require the highest timing precision from an array of the moststable millisecond pulsars. Several known sources of noise on short timescales in single radio pulsar observationsare well described by a simple model of three components: template fitting from a finite signal-to-noise ratio, pulsephase/amplitude jitter from single-pulse stochasticity, and scintillation errors from short-timescale interstellarscattering variations. Currently template-fitting errors dominate, but as radio telescopes push toward higher signalto-noise ratios, jitter becomes the next dominant term for most millisecond pulsars. Understanding the statistics ofjitter becomes crucial for properly characterizing arrival time uncertainties. We characterize the radio frequencydependence of jitter using data on 48 pulsars in the North American Nanohertz Observatory for GravitationalWaves timing program. We detect significant jitter in 43 of the pulsars and test several functional forms for itsfrequency dependence; we find significant frequency dependence for 30 pulsars. We find moderate correlations ofrms jitter with pulse width (R = 0.62) and number of profile components (R = 0.40); the single-pulse rms jitter istypically 1% of pulse phase. The average frequency dependence for all pulsars using a power-law model hasindex 0.42. We investigate the jitter variations for the interpulse of PSR B1937+21 and find no significantdeviations from the main pulse rms jitter. We also test the time variation of jitter in two pulsars and find thatsystematics likely bias the results for high-precision pulsars. Pulsar timing array analyses must properly modeljitter as a significant component of the noise within the detector.

Lam, M. T.↗

Performance Measurements of Electric Solid Propellant in an Ablative Pulsed Electric Thruster

Electric solid propellants are advanced solid chemical rocket propellants that can be controlled (ignited, throttled and extinguished) through the application and removal of an electric current. These propellants may also be used for electric in-space propulsion, specifically in the ablative pulsed plasma thruster. In this paper, we will investigate the performance of an electric solid propellant operating in an ablation-fed pulsed plasma device by use of an inverted pendulum micro-Newton thrust stand. Namely, the impulse-per-pulse and the specific impulse of the device using the electric solid propellant will be reported for test runs of 100 pulses and energy levels of 5, 10, 15 and 20 J. Further, the device will also be tested using the current state-of-the-art pulsed plasma thruster propellant, polytetrafluoroethylene. The performance of each propellant will be compared for each energy level using an identical setup and apparatus. This comparison of performance between propellants in a controlled setting will allow for better understanding of previous experimental observations.

Glascock, Matthew S.↗

Pulsed Plasma Acceleration Modeling in Detonation and Deflagration Modes

Gas-fed electromagnetic pulsed plasma accelerators discharge electrical energy into a gas to ionize and electromagnetically accelerate propellant in the domain. Efforts to model pulsed accelerators have either assumed that the discharge is short and completely transient, accelerating the gas by entraining it in a moving current sheet, or that the discharge is relatively long, establishing a stable quasi-steady current distribution pattern that accelerates a plasma flowing through it. There have been pulsed plasma accelerator tests that appear to fit somewhere between these two bounds, exhibiting some properties that are associated with the purely transient devices while also showing others that are associated with quasi-steady-state plasma acceleration. A model is presented based upon the premise that all pulsed plasma accelerators first form an accelerating current sheet (detonation mode accelerator). Depending upon the pulse length and the gas conditions in the dis- charge channel, the plasma sheet may reach the end of the accelerator before the discharge has completed a full half-cycle, wherein the proposed model transitions to a quasi-steady description of the acceleration process (deflagration mode accelerator). A review of the entire model is presented, highlighting improvements and upgrades implemented to aid in the stability of the numerical scheme used to model the gas flow in the channel and an improved treatment of current sheet mass shedding, which adds gas to the wake of the sheet. The assumptions employed to model the transition from detonation to deflagration mode are presented and used to generate solutions to the governing equations. The modeling of the deflagration-mode under the present assumptions results in very low deflagration impulse bits relative to those obtained at the end of the detonation mode, implying that the present assumptions and modeling of the deflagration mode may not represent a fruitful approach.

Polzin, Kurt A.↗

Ultrashort Pulse Laser Surface Processing Techniques for Sterilization of Metal Surfaces for Planetary Protection

To prevent forward contamination from microbes aboard spacecraft intended to search for extraterrestrial life, there is a need for effective sterilization methods. However, current techniques are both time-consuming and expensive. For example, dry heat sterilization requires removal from the assembly site and several days of treatment. Furthermore, some components such as optics and electronics are not compatible with current sterilization techniques. Here, we report the latest results in our development of a novel femtosecond laser processing technique for the rapid sterilization of spacecraft hardware. Femtosecond lasers produce extremely high photon fluxes (10^29 photons/sec*cm^2, ~0.03 J/cm^2) in extremely short pulses, which can inactivate even stress-tolerant microbial spores with minimal damage to the spacecraft surface. Aluminum coupons were inoculated with specific densities of Bacillus subtilis bacterial endospores. These coupons were treated with various laser illumination parameters. Afterward, metal coupon samples were assayed for viable spores using a polyvinyl alcohol (PVA) peel, serial dilution, and plating for colony-forming units (CFU). Results indicate that with high enough energy density and pulse counts, most bacterial spores are inactivated with minimal damage to the metal. The sterilization is dependent on both the fluence and pulse count. In addition, femtosecond pulses are more effective than longer pulses for inactivation. These experiments have consistently achieved 4-log reduction in viable spores. Sterilization has been achieved on both flat metal coupons and non-flat surfaces with microchannels, with a slight reduction in sterilization efficiency on the uneven surface. The application of air flow during laser processing was also investigated as a way to remove spores that are dislodged from the surface by the laser illumination, which would contribute to the reduction of spacecraft bioburden. With laser processing technology rapidly evolving, our results support the possibility of an extremely rapid, in-situ surface sterilization method for use in spacecraft assembly clean rooms.

Kaleb McQuillan↗

INJECTION STRAIGHT PULSED MAGNET ERROR TOLERANCE STUDY FOR TOP-OFF INJECTION

NSLS II is designed to work in top-off injection mode. The injection straight includes a septum and four fast kicker magnets. The pulsed magnet errors will excite a betatron oscillation. This paper gives the formulas of each error contribution to the oscillation amplitude at various source points in the ring. These are compared with simulation results. Based on the simple formulas, we can specify the error tolerances on the pulsed magnets with the goal to minimize the injection transient and scale it to similar machines. The NSLS-II is a 3 GeV third generation synchrotron light source under construction at Brookhaven National Laboratory. Due to its short lifetime, NSLS-II storage ring requires the top-off injection (once per minute) during which the stored beam orbit is highly desired as transparent. But the errors, from the SR pulsed magnets at the injection straight - kickers (non-closed injection bump) and pulsed septum (time-dependent stray field), excite a stored beam betatron oscillation. The magnitude of the perturbation can be large disturning some of the user experiments. In 2010 injection straight review, based on the experts experiences in ALS, DIAMOND, SLS and SPEAR, we came to the conclusion that the acceptable oscillation amplitude at the long straight is set as 100 {micro}m (i.e. 0.7 {sigma}x) in horizontal plane and 12 {micro}m, 2.5 {sigma}y, in vertical plane for NSLS II. This paper gives the analysis estimate of the different error source tolerance from the pulse magnets and scales it to our requirements. The result is compared with simulation.

43 PARTICLE ACCELERATORS↗

Laser ion source with long pulse width for RHIC-EBIS

The Electron Beam Ion Source (EBIS) at Brookhaven National Laboratory is a new heavy ion-projector for RHIC and NASA Space Radiation Laboratory. Laser Ion Source (LIS) with solenoid can supply many kinds of ion from solid targets and is suitable for long pulse length with low current as ion provider for RHIC-EBIS. In order to understand a plasma behavior for fringe field of solenoid, we measure current, pulse width and total ion charges by a new ion probe. The experimental result indicates that the solenoid confines the laser ablation plasma transversely. Laser ion source needs long pulse length with limited current as primary ion provider for RHIC-EBIS. New ion probe can measure current distribution for the radial positions along z axis. The beam pulse length is not effected by magnetic field strength. However, the currents and charges decay with the distance from the end of solenoid. These results indicate that solenoid field has important role for plasma confinement not longitudinally but transversely and solenoid is able to have long pulse length with sufficient total ion charges. Moreover, the results are useful for a design of the extraction system for RHIC-EBIS.

43 PARTICLE ACCELERATORS↗

Pulsed voltage electrospray ion source and method for preventing analyte electrolysis

An electrospray ion source and method of operation includes the application of pulsed voltage to prevent electrolysis of analytes with a low electrochemical potential. The electrospray ion source can include an emitter, a counter electrode, and a power supply. The emitter can include a liquid conduit, a primary working electrode having a liquid contacting surface, and a spray tip, where the liquid conduit and the working electrode are in liquid communication. The counter electrode can be proximate to, but separated from, the spray tip. The power system can supply voltage to the working electrode in the form of a pulse wave, where the pulse wave oscillates between at least an energized voltage and a relaxation voltage. The relaxation duration of the relaxation voltage can range from 1 millisecond to 35 milliseconds. The pulse duration of the energized voltage can be less than 1 millisecond and the frequency of the pulse wave can range from 30 to 800 Hz.

47 OTHER INSTRUMENTATION↗

Pulsed Gamma-Rays From PSR J2021 3651 with the Fermi Large Area Telescope

We report the detection of pulsed gamma-rays from the young, spin-powered radio pulsar PSR J2021+3651 using data acquired with the Large Area Telescope (LAT) on the Fermi Gamma-ray Space Telescope (formerly GLAST). The light curve consists of two narrow peaks of similar amplitude separated by 0.468 {+-} 0.002 in phase. The first peak lags the maximum of the 2 GHz radio pulse by 0.162 {+-} 0.004 {+-} 0.01 in phase. The integral gamma-ray photon flux above 100 MeV is (56 {+-} 3 {+-} 11) x 10{sup -8} cm{sup -2} s{sup -1}. The photon spectrum is well-described by an exponentially cut-off power law of the form dF/dE = kE{sup -{Gamma}}e{sup (-E/E{sub c})} where the energy E is expressed in GeV. The photon index is {Gamma} = 1.5 {+-} 0.1 {+-} 0.1 and the exponential cut-off is E{sub c} = 2.4 {+-} 0.3 {+-} 0.5 GeV. The first uncertainty is statistical and the second is systematic. The integral photon flux of the bridge is approximately 10% of the pulsed emission, and the upper limit on off-pulse gamma-ray emission from a putative pulsar wind nebula is < 10% of the pulsed emission at the 95% confidence level. Radio polarization measurements yield a rotation measure of RM = 524 {+-} 4 rad m{sup -2} but a poorly constrained magnetic geometry. Re-analysis of Chandra data enhanced the significance of the weak X-ray pulsations, and the first peak is roughly phase-aligned with the first gamma-ray peak. We discuss the emission region and beaming geometry based on the shape and spectrum of the gamma-ray light curve combined with radio and X-ray measurements, and the implications for the pulsar distance. Gamma-ray emission from the polar cap region seems unlikely for this pulsar.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Global synchronization of parallel processors using clock pulse width modulation

A circuit generates a global clock signal with a pulse width modification to synchronize processors in a parallel computing system. The circuit may include a hardware module and a clock splitter. The hardware module may generate a clock signal and performs a pulse width modification on the clock signal. The pulse width modification changes a pulse width within a clock period in the clock signal. The clock splitter may distribute the pulse width modified clock signal to a plurality of processors in the parallel computing system.

97 MATHEMATICS AND COMPUTING↗

Small Gas Bubble Experiment for Mitigation of Cavitation Damage and Pressure Waves in Short-pulse Mercury Spallation Targets

Populations of small helium gas bubbles were introduced into a flowing mercury experiment test loop to evaluate mitigation of beam-pulse induced cavitation damage and pressure waves. The test loop was developed and thoroughly tested at the Spallation Neutron Source (SNS) prior to irradiations at the Los Alamos Neutron Science Center - Weapons Neutron Research Center (LANSCE-WNR) facility. Twelve candidate bubblers were evaluated over a range of mercury flow and gas injection rates by use of a novel optical measurement technique that accurately assessed the generated bubble size distributions. Final selection for irradiation testing included two variations of a swirl bubbler provided by Japan Proton Accelerator Research Complex (J-PARC) collaborators and one orifice bubbler developed at SNS. Bubble populations of interest consisted of sizes up to 150 m in radius with achieved gas void fractions in the 10^-5 to 10^-4 range. The nominal WNR beam pulse used for the experiment created energy deposition in the mercury comparable to SNS pulses operating at 2.5 MW. Nineteen test conditions were completed each with 100 pulses, including variations on mercury flow, gas injection and protons per pulse. The principal measure of cavitation damage mitigation was surface damage assessment on test specimens that were manually replaced for each test condition. Damage assessment was done after radiation decay and decontamination by optical and laser profiling microscopy with damaged area fraction and maximum pit depth being the more valued results. Damage was reduced by flow alone; the best mitigation from bubble injection was between half and a quarter that of flow alone. Other data collected included surface motion tracking by three laser Doppler vibrometers (LDV), loop wall dynamic strain, beam diagnostics for charge and beam profile assessment, embedded hydrophones and pressure sensors, and sound measurement by a suite of conventional and contact microphones.

bubbles↗

Elemental analysis using temporal gating of a pulsed neutron generator

Technologies related to determining elemental composition of a sample that comprises fissile material are described herein. In a general embodiment, a pulsed neutron generator periodically emits bursts of neutrons, and is synchronized with an analyzer circuit. The bursts of neutrons are used to interrogate the sample, and the sample outputs gamma rays based upon the neutrons impacting the sample. A detector outputs pulses based upon the gamma rays impinging upon the material of the detector, and the analyzer circuit assigns the pulses to temporally-based bins based upon the analyzer circuit being synchronized with the pulsed neutron generator. A computing device outputs data that is indicative of elemental composition of the sample based upon the binned pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Apparatus for GHz rate high duty cycle pulsing and manipulation of low and medium energy DC electron beams

An ElectroMagnetic-Mechanical Pulser can generate electron pulses at rates up to 50 GHz, energies up to 1 MeV, duty cycles up to 10%, and pulse widths between 100 fs and 10 ps. A modulating Transverse Deflecting Cavity (“TDC”) imposes a transverse modulation on a continuous electron beam, which is then chopped into pulses by an adjustable Chopping Collimating Aperture. Pulse dispersion due to the modulating TDC is minimized by a suppressing section comprising a plurality of additional TDC's and/or magnetic quadrupoles. In embodiments the suppression section includes a magnetic quadrupole and a TDC followed by four additional magnetic quadrupoles. The TDC's can be single-cell or triple-cell. A fundamental frequency of at least one TDC can be tuned by literally or virtually adjusting its volume. TDC's can be filled with vacuum, air, or a dielectric or ferroelectric material. Embodiments are easily switchable between passive, continuous mode and active pulsed mode.

Baryshev, Sergey V.↗

Conceptual Design of the Project-X 1.3 GHz, 3-8 GeV Pulsed Linac

The Project-X, a multi-MW proton source, is under development at Fermilab. It enables a Long Baseline Neutrino Experiment via a new beam line pointed to DUSEL in Lead, South Dakota, and a broad suite of rare decay experiments. The facility co ntains 3-GeV 1-mA CW superconducting linac. In the second stage of about 5% of the H- beam is accelerated up to 8 GeV in a 1.3 GHz SRF pulse linac to Recycler/Main Injector. In order to mitigate the problem with the stripping foil heating during injection to the Main Injector, the pulses with higher current are accelerated in CW linac together with 1 mA beam for further acceleration in the pulse linac. The optimal current in the pulse linac is discussed as well as limitations that determine it's selection . A concept design of the pulse linac is described. The lattice design is presented as well as RF stability analysis. The necessity of the HOM couplers is discussed also.

43 PARTICLE ACCELERATORS↗

Multi-channel pulsed valve inlet system and method

A multichannel inlet system for a mass spectrometer includes a plurality of valve assemblies coupled to a manifold, and a pulsed valve driver. The manifold is configured to be connected in fluid connection with an ion trap of the mass spectrometer. Each valve assembly includes a valve and an injection port operably coupled to receive the reagent. The valve has an actuated state in which the valve provides fluid communication between the injection port and the manifold, and an unactuated state in which the valve substantially prevents fluid communication between the injection port and the manifold. The pulsed valve driver is operably connected to receive a pulse signal sequence from a processor, and is configured to generate pulsed valve drive signals for one or more of the valves based on the pulse signal sequence to cause a corresponding one of the valves to be in the actuated state.

Kenttamaa, Hilkka↗

Fast image acquisition system and method using pulsed light illumination and sample scanning to capture optical micrographs with sub-micron features

An optical inspection system for detecting sub-micron features on a sample component. The system may have a controller, a camera responsive to the controller for capturing images, an objective lens able to capture submicron scale features on the sample component, and a pulsed light source. The pulsed light source may be used to generate light pulses. The camera may be controlled to acquire images, using the objective lens, only while the pulsed light source is providing light pulses illuminating a portion of the sample component. Relative movement between the sample component and the objective lens is provided to enable at least one of a desired subportion or an entirety of the sample component to be scanned with the camera.

Yoo, Jae Hyuck↗