Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “parameter calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

International comparison of radiometers - Techniques and results.

Description of an international comparison of radiometers made on May 10 through 14, 1971, with 24 instruments, each one representing the calibration standard of a different country or a major laboratory. All were pyranometers, viewing the sun and sky, thus bypassing the conventional method of transferring the standard from Angstrom pyrheliometers. This is the first time that pyranometers from all around the globe have been brought together in order to verify the scale on which to report solar radiation data. A highly accurate data collection system measured simultaneously the output of each instrument and that of a reference standard at 20-sec intervals. Over 300,000 radiometric signals were recorded under varying atmospheric conditions, as well as data on turbidity, temperature, and other relevant parameters. Computer programs were developed for overnight analysis of the data and distribution to participants on the following day. Among major findings are that instruments of different types and independent calibration such as those of Eppley, U. S. A., World Radiation Center, Switzerland, and Melbourne, Australia, show better agreement than anticipated, that certain national standards have to be revised by as much as 16% and that the cosine factor is highly dependent on the type of instrument.

Thekaekara, M. P.↗

Physics-Informed and Data-Driven Prediction of Residual Stress in Three-Dimensional Machining

Efficient and reliable prediction of machining-induced residual stress (RS) is a key requirement for truly integrated computational materials engineering (ICME). Currently available process modeling approaches, including empirical, analytical, and numerical methodologies lack predictive power and require substantial calibration and validation data. Moreover, most model-based approaches consider only two-dimensional (2D) (i.e., orthogonal), cutting processes. Meanwhile, industrial processes such as milling, turning, and drilling are inherently three-dimensional (3D). The present work attempts to bridge the gap between 2D and 3D through careful consideration of the process physics, including geometric, kinematic, and size-effect constraints to realize robust prediction of how RS develops in 3D machining. Using a novel in-situ experimental technique and digital image correlation (DIC) to determine equivalent Hertzian contact widths, contact pressures, and friction coefficients, the proposed methodology leverages a discretized conversion algorithm that includes multi-pass shakedown effects. This paper presents a semi-analytical model to predict machining-induced RS in 3D turning operations, which are used representatively for 3D processes more generally. Rather than follow a ‘brute force’ 3D FEM approach or conduct countless experiments to train a purely data-driven machine learning algorithm, the proposed approach builds on previous 2D modeling work. Through careful consideration of the process physics, including complex geometry/kinematic considerations of 3D turning, the authors demonstrated an experimentally calibrated approach, as well as validation based on published RS data. Model predictions and previously published measurement data of RS depth profiles for turning of Inconel 718 were compared for a range of process parameters. Correlation between the proposed 3D model and validation data was found to be within the margin of experimental error for most conditions. The proposed model appears to capture the overall behavior of 3D RS depth profiles with acceptable accuracy, particularly the key metrics of near-surface stress, peak stress magnitude and location, as well as overall stress profile depth. This report presents a physics-informed, data-driven approach for efficient calibration of a 2D model for machining-induced RS through DIC analysis of in-situ characterized subsurface displacement fields.

42 ENGINEERING↗

Morphometric Characterization of Lunar Landing Sites

As ambitious surface exploration of the Moon commences in the 2020s, it is important to develop reliable and objective metrics for understanding the quality of future landing sites. A key prerequisite for any exploration and utilization of the lunar surface is a safe landing. One of the most important methods to provide understanding of potential metrics for landing site safety in the lunar context is the systematic comparison of candidate and historic landing sites. The goal of this project is to determine the morphometric parameters of the lunar surface at 16 successful lunar landing sites where adequate data exists to execute a quantitative comparison using various parameters. Quantitative analysis of Lunar Reconnaissance Orbiter (LRO) data should inform mission planning activities by providing morphologic metrics for landing sites including slope, Terrain Ruggedness Index (TRI), and rock abundance. These comparisons will assist mission planners and exploration scientists by providing “calibration points” for using Lunar Reconnaissance Orbiter (LRO) data to successfully plan and execute lunar powered descents in the future. The metrics included in this analysis describe the form of the terrain and can be calculated for any potential future landing site. Another objective of this project is to determine how the derived morphologic parameters for the same landing site change between common pixel scales. In ideal lighting conditions, 2m/px Narrow Angle Camera Digital Terrain Models (NAC DTMs) can be assembled using stereoscopic imagery from two or more concentric orbits of the LRO. However, due to low light conditions near the lunar poles, the highest quality data for many potential lunar landing sites comes from the Lunar Orbiter Laser Altimeter (LOLA). Therefore, we seek to assess how the derived slope and TRI values change as a function of changes in the DTM postings from 2m/px to 5m/px.

J M McCallion↗

Laboratory calibration of AAFE radiometer/scatterometer (RADSCAT)

A brief description of the electrical and mechanical instrument configuration, followed by an extensive discussion of laboratory tests and results are contained herein. This information is required to provide parameters for data reduction, and a basis for analysis of the measurement errors in data taken with this instrument.

Schroeder, L. C.↗

Performance Assessments and Comparisons of S-NPP and NOAA-20 (JPSS-1) VIIRS On-Orbit Calibration

The first Visible Infrared Imaging Radiometer Suite (VIIRS) instrument has been in operation for more than 6 years on-board the S-NPP satellite and the second instrument, with the same design and performance requirements, was launched in November, 2017 on-board the JPSS-1 satellite (named NOAA-20 after reaching its orbit) and is currently in normal operation conditions. This paper provides a brief description of VIIRS on-orbit calibration and characterization activities and presents performance assessments and comparisons of S-NPP and NOAA-20 VIIRS using data collected from their on-board calibrators (OBC) and regularly scheduled lunar observations. Results show that NOAA-20 VIIRS is performing as well or better than S-NPP VIIRS in all of the key performance metrics. The NOAA-20 reflective solar bands, including the day-night band, have experienced less than 1% change in gain in the first 250 days since launch and did not suffer from the contamination related rapid degradation experienced by S-NPP VIIRS. Some of the NOAA20 thermal emissive bands had larger than expected gain degradation after launch due to ice buildup on the dewar window of the long-wave IR focal plane assembly but a mid-mission outgassing operation was able to restore their gains and maintain stable behavior. Though this study is focused on the sensor's key performance parameters, such as detector responses (gains), signal-to-noise ratios, and noise-equivalent temperature differences, challenges identified and lessons learned through different phases of on-orbit calibration and characterization are also discussed.

DNB↗

Validation of Cloud Parameters Derived from Geostationary Satellites, AVHRR, MODIS, and VIIRS Using SatCORPS Algorithms

Validation is a key component of remote sensing that can take many different forms. The NASA LaRC Satellite ClOud and Radiative Property retrieval System (SatCORPS) is applied to many different imager datasets including those from the geostationary satellites, Meteosat, Himiwari-8, INSAT-3D, GOES, and MTSAT, as well as from the low-Earth orbiting satellite imagers, MODIS, AVHRR, and VIIRS. While each of these imagers have similar sets of channels with wavelengths near 0.65, 3.7, 11, and 12 micrometers, many differences among them can lead to discrepancies in the retrievals. These differences include spatial resolution, spectral response functions, viewing conditions, and calibrations, among others. Even when analyzed with nearly identical algorithms, it is necessary, because of those discrepancies, to validate the results from each imager separately in order to assess the uncertainties in the individual parameters. This paper presents comparisons of various SatCORPS-retrieved cloud parameters with independent measurements and retrievals from a variety of instruments. These include surface and space-based lidar and radar data from CALIPSO and CloudSat, respectively, to assess the cloud fraction, height, base, optical depth, and ice water path; satellite and surface microwave radiometers to evaluate cloud liquid water path; surface-based radiometers to evaluate optical depth and effective particle size; and airborne in-situ data to evaluate ice water content, effective particle size, and other parameters. The results of comparisons are compared and contrasted and the factors influencing the differences are discussed.

Minnis, P.↗

Uncertainty Analysis of the Single-Vector Force Balance Calibration System

This paper presents an uncertainty analysis of the Single-Vector Force Balance Calibration System (SVS). This study is focused on the uncertainty involved in setting the independent variables during the calibration experiment. By knowing the uncertainty in the calibration system, the fundamental limits of the calibration accuracy of a particular balance can be determined. A brief description of the SVS mechanical system is provided. A mathematical model is developed to describe the mechanical system elements. A sensitivity analysis of these parameters is carried out through numerical simulations to assess the sensitivity of the total uncertainty to the elemental error sources. These sensitivity coefficients provide valuable information regarding the relative significance of the elemental sources of error. An example calculation of the total uncertainty for a specific balance is provided. Results from this uncertainty analysis are specific to the Single-Vector System, but the approach is broad in nature and therefore applicable to other measurement and calibration systems.

Parker, Peter A.↗

Bayesian uncertainty quantification of tristructural isotropic particle fuel silver release: Decomposing model inadequacy plus experimental noise and parametric uncertainties

Tristructural isotropic (TRISO) particle fuel is one of the most promising fuel concepts enabling high temperature and high burnup reactor operation. One dominant source of radioactivity released from the TRISO particles is silver (Ag), which is subject to a high release fraction and long decay life compared to other fission products. Previous modeling efforts using the fuel performance code BISON indicated nonnegligible uncertainties in modeling the diffusion process of fission products in TRISO compared to the Advanced Gas Reactor experiments. The overall uncertainties observed when modeling the fission product diffusion can result from uncertainties in model parameters, noisy experimental measurements, and deficiencies in the developed models. The three types of underlying uncertainties have not yet been properly quantified in open literature. Here, this paper presents the Bayesian uncertainty quantification (UQ) using massively parallelizable Markov chain Monte Carlo samplers. The uncertainties due to model parameters, model inadequacy, and experimental measurement noise are quantified, with the σ term used to represent the sum of the model inadequacy and measurement noise uncertainties. It is worth noting that this is the first time the σ term is inferred for nuclear fuel experiments, as compared to using prescribed values for uncertainty quantification in previous work. The parallelizable Markov chain Monte Carlo samplers efficiently infer the model parameters and the σ term, giving insight into physical parameters like diffusion coefficients and the combined model discrepancy and measurement noise. A subsequent forward uncertainty quantification (UQ) is also performed based on the calibration results to generate more accurate predictions of the Ag release. The model inadequacy plus experimental noise is the most dominant source of uncertainty compared to the parametric uncertainty. All the UQ analyses presented in this work are based on the second series of the irradiation experiments in the Advanced Gas Reactor program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Bayesian calibration of irradiated graphite property models under high temperatures

Graphite under high temperatures and irradiation is central to advanced reactors. We develop a Bayesian calibration framework for graphite property models that explicitly represents model-data mismatch via a Gaussian-process discrepancy. The approach propagates uncertainty from parameters, experimental noise, and model form, with a hierarchical variance structure to capture group and cross-group noise. Using two predictive models across five grades (IG-110, NBG-18, PCEA, NBG-17, 2114) and four properties-irradiation-induced dimension change, creep, Young’s modulus change ratio, and coefficient of thermal expansion change ratio-we obtain average predictive-error reductions of 54%, 65%, 17%, and 17% when discrepancy is included. We illustrate engineering impact with a multiphysics model of a very-high-temperature reactor prismatic reflector brick, analyzing stresses under high fluence and temperature. Accounting for model discrepancy markedly improves predictive accuracy and provides a robust basis for reliable graphite component design in advanced reactors.

36 - MATERIALS SCIENCE↗

Database of pharmacokinetic time-series data and parameters for 144 environmental chemicals

Time courses of compound concentrations in plasma are used in chemical safety analysis to evaluate the relationship between external administered doses and internal tissue exposures. This type of experimental data is rarely available for the thousands of non-pharmaceutical chemicals to which people may potentially be unknowingly exposed but is necessary to properly assess the risk of such exposures. In vitro assays and in silico models are often used to craft an understanding of a chemical’s pharmacokinetics; however, the certainty of the quantitative application of these estimates for chemical safety evaluations cannot be determined without in vivo data for external validation. To address this need, we present a public database of chemical time-series concentration data from 567 studies in humans or test animals for 144 environmentally-relevant chemicals and their metabolites (187 analytes total). All major administration routes are incorporated, with concentrations measured in blood/plasma, tissues, and excreta. We also include calculated pharmacokinetic parameters for some studies, and a bibliography of additional source documents to support future extraction of time-series. In addition to pharmacokinetic model calibration and validation, these data may be used for analyses of diferential chemical distribution across chemicals, species, doses, or routes, and for meta-analyses on pharmacokinetic studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Medium-Scale Methanol Pool Fire Model Validation

In this work, medium scale (30 cm diameter) methanol pool fires were simulated using the latest fire modeling suite implemented in Sierra/Fuego, a low Mach number multiphysics reacting flow code. The sensitivity of model outputs to various model parameters was studied with the objective of providing model validation. This work also assesses model performance relative to other recently published large eddy simulations (LES) of the same validation case. Two pool surface boundary conditions were simulated. The first was a prescribed fuel mass flux and the second used an algorithm to predict mass flux based on a mass and energy balance at the fuel surface. Gray gas radiation model parameters (absorption coefficients and gas radiation sources) were varied to assess radiant heat losses to the surroundings and pool surface. The radiation model was calibrated by comparing the simulated radiant fraction of the plume to experimental data. The effects of mesh resolution were also quantified starting with a grid resolution representative of engineering type fire calculations and then uniformly refining that mesh in the plume region. Simulation data were compared to experimental data collected at the University of Waterloo and the National Institute of Standards and Technology (NIST). Validation data included plume temperature, radial and axial velocities, velocity temperature turbulent correlations, velocity velocity turbulent correlations, radiant and convective heat fluxes to the pool surface, and plume radiant fraction. Additional analyses were performed in the pool boundary layer to assess simulated flame anchoring and the effect on convective heat fluxes. This work assesses the capability of the latest Fuego physics and chemistry model suite and provides additional insight into pool fire modeling for nonluminous, non-sooting flames.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First demonstration of a TES based cryogenic Li 2 MoO 4 detector for neutrinoless double beta decay search

Cryogenic calorimetric experiments to search for neutrinoless double-beta decay (0vββ) are highly competitive, scalable and versatile in isotope. The largest planned detector array, CUPID, is comprised of about 1500 individual Li 2 100 MoO 4 detector modules with a further scale up envisioned for a follow up experiment (CUPID-1T). In this article, we present a novel detector concept targeting this second stage with a low impedance TES based readout for the Li 2 MoO 4 absorber that is easily mass-produced and lends itself to a multiplexed readout. We present the detector design and results from a first prototype detector operated at the NEXUS shallow underground facility at Fermilab. The detector is a 2-cm-side cube with 21 g mass that is strongly thermally coupled to its readout chip to allow rise-times of ~0.5 ms. This design is more than one order of magnitude faster than present NTD based detectors and is hence expected to effectively mitigate backgrounds generated through the pile-up of two independent two neutrino decay events coinciding close in time. Together with a baseline resolution of 1.95 keV (FWHM) these performance parameters extrapolate to a background index from pile-up as low as 5 • 10 –6 counts/keV/kg/yr in CUPID size crystals. The detector was calibrated up to the MeV region showing sufficient dynamic range for 0vββ searches. In combination with a SuperCDMS HVeV detector this setup also allowed us to perform a precision measurement of the scintillation time constants of Li 2 MoO 4 , which showed a primary component with a fast O(20 μs) time scale. Similar content being viewe

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration and Commissioning of the LSST

Understanding the nature of dark energy and dark matter remains one of the fundamental questions in physics today; impacting our understanding of particle physics, cosmology, and possibly theories of gravity. Given the scale and complexity of the next generation of cosmology experiments (e.g., the Rubin Observatory, the Euclid satellite mission, and the Roman space telescope) we are entering an era where statistical noise no longer determines the accuracy to which we can measure cosmological parameters. Our ability to control and correct for systematics will ultimately determine the scientific impact of these experiments. This award addressed the challenge of how we determine what limits the accuracy of our cosmological measures, what techniques are appropriate for measuring and calibrating the properties of galaxies to best constrain cosmological models, how to develop statistical techniques that are insensitive to systematic errors, and how to optimize survey strategies in order to minimize systematics while maximizing the speed at which an experiment can achieve its science objectives. In this final technical report for award DE-SC0011635 we describe a set of open-source frameworks that simulate the characteristics and properties of current and planned cosmology surveys and the application of these frameworks to the development of new methodologies for estimating the properties and distances to galaxies that are robust to noisy and incomplete data.

79 ASTRONOMY AND ASTROPHYSICS↗

Octofitter: Fast, Flexible, and Accurate Orbit Modeling to Detect Exoplanets

As next-generation imaging instruments and interferometers search for planets closer to their stars, they must contend with increasing orbital motion and longer integration times. These compounding effects make it difficult to detect faint planets but also present an opportunity. Increased orbital motion makes it possible to move the search for planets into the orbital domain, where direct images can be freely combined with the radial velocity and proper motion anomaly, even without a confirmed detection in any single epoch. In this paper, we present a fast and differentiable multimethod orbit-modeling and planet detection code called Octofitter. This code is designed to be highly modular and allows users to easily adjust priors, change parameterizations, and specify arbitrary function relations between the parameters of one or more planets. Octofitter further supplies tools for examining model outputs including prior and posterior predictive checks and simulation-based calibration. We demonstrate the capabilities of Octofitter on real and simulated data from different instruments and methods, including HD 91312, simulated JWST/NIRISS aperture masking interferometry observations, radial velocity curves, and grids of images from the Gemini Planet Imager. We show that Octofitter can reliably recover faint planets in long sequences of images with arbitrary orbital motion. This publicly available tool will enable the broad application of multiepoch and multimethod exoplanet detection, which could improve how future targeted ground- and space-based surveys are performed. Finally, its rapid convergence makes it a useful addition to the existing ecosystem of tools for modeling the orbits of directly imaged planets.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative evaluation of water quality in the coastal zone by remote sensing

Remote sensing as a tool in a waste management program is discussed. By monitoring both the pollution sources and the environmental quality, the interaction between the components of the exturaine system was observed. The need for in situ sampling is reduced with the development of improved calibrated, multichannel sensors. Remote sensing is used for: (1) pollution source determination, (2) mapping the influence zone of the waste source on water quality parameters, and (3) estimating the magnitude of the water quality parameters. Diffusion coefficients and circulation patterns can also be determined by remote sensing, along with subtle changes in vegetative patterns and density.

James, W. P.↗

Calibration of small gauge thermocouples.

A technique has been developed to dynamically calibrate fine wire thermocouples of 0.025 mm diam and smaller to 1625 K in less than 10 sec. In this method, the varying physical parameters present under typical dynamic heating conditions are simulated, and therefore, wire deterioration can be related to time, temperature, pressure, and atmosphere. A description of the equipment and procedures is given along with the preliminary results that correlate well with thermoelectric theory.

Stewart, W. F.↗

Validating regional differences in modelled satellite microwave signatures

A three-part microwave T(B) brightness temperature model was tested for applicability in regions of differing climatic and vegetation regime. Model parameters were limited to vegetation in the form of the normalized vegetation index (NDVI) and climatically modeled soil moisture. The T(B) model was calibrated for two climatically contrasting areas and subsequently validated on different test sites of similar climatic character. Vegetative characteristics in the form of the mean NDVI was used to partition and lump data from different test sites. Good agreement was realized between estimated T(B) and Nimbus-7 SMMR T(B) at the 6.6 GHz horizontal channel.

Owe, Manfred↗

A summary of recent aircraft/ground vehicle friction measurement tests

Tests were carried out to evaluate a variety of runway surface types and wetness conditions, using specially instrumented NASA B-737 and B-727 aircraft and several ground friction measuring devices. The performance data for aircraft braking on dry, wet, snow-covered, and ice-covered runway conditions are presented and compared to ground-vehicle friction data obtained under similar runway conditions. The relationships between ground vehicles and the aircraft friction data are identified, and the effects on friction of major test parameters, such as the speed, the tire characteristics, and the type of surface-contaminant are discussed. The results demonstrated that properly maintained and calibrated ground vehicles can be used to monitor the runway friction conditions.

Yager, Thomas J.↗