Interconnection-wide hour-ahead scheduling in the presence of intermittent renewables and demand response: A surplus maximizing approach

This study describes a new approach for solving the multi-area electricity resource allocation problem when considering both intermittent renewables and demand response. The method determines the hourly inter-area export/import set that maximizes the interconnection (global) surplus satisfying transmission, generation and load constraints. The optimal inter-area transfer set effectively makes the electricity price uniform over the interconnection apart from constrained areas, which overall increases the consumer surplus more than it decreases the producer surplus. The method is computationally efficient and suitable for use in simulations that depend on optimal scheduling models. The method is demonstrated on a system that represents North America Western Interconnection for the planning year of 2024. Simulation results indicate that effective use of interties reduces the system operation cost substantially. Excluding demand response, both the unconstrained and the constrained scheduling solutions decrease the global production cost (and equivalently increase the global economic surplus) by 12.30B and 10.67B per year, respectively, when compared to the standalone case in which each control area relies only on its local supply resources. This cost saving is equal to 25% and 22% of the annual production cost. Including 5% demand response, the constrained solution decreases the annual production cost by 10.70B, while increases the annual surplus by 9.32B in comparison to the standalone case.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The combined value of wind and solar power forecasting improvements and electricity storage

As the penetration rates of variable renewable energy increase, the value of power systems operation flexibility technology options, such as renewable energy forecasting improvements and electricity storage, is also assumed to increase. In this work, we examine the value of these two technologies, when used independently and concurrently, for two real case studies that represent the generation mixes for the California and Midcontinent Independent System Operators (CAISO and MISO). Since both technologies provide additional system flexibility they reduce operational costs and renewable curtailment for both generation mixes under study. Interestingly, the relative impacts are quite similar when both technologies are used together. Though both flexibility options can solve some of the same issues that arise with high penetration levels of renewables, they do not seem to significantly increase or decrease the economic potential of the other technology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An MILP framework for optimizing demand response operation of air separation units

Renewable electricity generation and consumer demand are desynchronized in time, posing a challenge for grid operators. Industrial demand response (DR), has emerged as a strong candidate for mitigating demand variability. In this paper, we demonstrate the application of DR to an air separation unit (ASU), a chemical process that consumes significant amounts of electricity. We develop a novel optimal production scheduling framework that accounts for day-ahead electricity prices to modulate the grid load presented by the plant. Our framework accounts for the dynamics of the plant using a novel dynamic modeling framework. Further, we present a new decomposition scheme that allows us to solve the corresponding optimization problem in a matter of minutes. Extensive simulation results show significant reductions in operating costs (that benefit the plant) and reductions in peak power demand (which benefits the grid).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Extended convex hull-based distributed optimal energy flow of integrated electricity-gas systems

Integrated electricity and gas systems are constructed to facilitate the gas-fired generation, and the distributed operation of these integrated systems have received much attention due to the increased emphasis on data security and privacy between different agencies. This paper proposes an extended convex hull based method to address optimal energy flow problems for the integrated electricity and gas systems in a distributed manner. First, a multi-block electricity-gas system model is constructed by dividing the whole system into N blocks considering both physical and regional differences. This multi-block model is then convexified by replacing the nonconvex gas transmission equation with the extended convex hull-based constraints. The Jacobi-Proximal alternating direction method of multipliers algorithm is adopted to solve the convexified model and minimize its operation cost. Finally, the feasibility of the optimal solution for the convexified model is checked, and a sufficient condition is developed. If the sufficient condition is satisfied, the optimal solution for the original nonconvex problem can be recovered from that for the convexified problem. Simulation results demonstrate that the proposed method is tractable and effective in obtaining feasible optimal solutions for multi-block optimal energy flow problems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of alternatives for the evolution of palm oil mills into biorefineries

Six alternatives for the conversion of an average Colombian palm oil mill (30 t/h) of fresh fruit bunches (FFB) into biorefineries were evaluated. The alternatives studied were: (C1) Production of biogas from the Palm Oil Mill Effluents (POME), (C2) Composting of empty fruit bunches (EFB) and fiber, (C3) Biomass combustion for high pressure steam combined heat and power, (C4) Pellets production, (C5) Biochar production and, (C6) Biochar and bio-oil production. The available biomass could result in up to 125 kWh of electricity, 207 kg of compost, 125 kg of pellet, 44 kg of biochar and 63 kg of bio-oil per metric ton of FFB. The global warming potential (GWP), eutrophication potential (EP), net energy ratio (NER), capital expenditures (CAPEX), operational costs (OPEX), net present value (NPV) and internal rate of return (IRR) were calculated for all the alternatives. GHG reductions of more than 33% could be achieved. Anaerobic digestion and composting contributed to 30% reduction of the EP. The CAPEX for all of the biorefinery alternatives studied varies between 0.7 $/t and 2.8 $/t of FFB. The OPEX varies between 1.6 $/t and 7.3 $/t of FFB. The NPV for viable scenarios ranged between 2.5 million and 13.9 million US dollars. The IRR calculated varied between 3% and 56% and the payback periods were between 3 and 8 years. The total extra incomes reached values up to 15.2 $/t of FFB. Overall the pellets production biorefinery was the preferred alternative.

palm oil mill, biorefinery comparison, Life Cycle ↗

Regional difference and related cooling electricity savings of air pollutant affected natural ventilation in commercial buildings across the US

Maintaining indoor air pollutants under acceptable levels is significant to protect occupants from exposure to excessive air pollutants in natural ventilation. In this paper, using the representative air pollutant concentration data, we present the natural ventilation usability with associated cooling energy saving potentials in different location settings (urban and city center, suburban and rural) of the US under the influence of local weather conditions and major outdoor air pollutants, i.e. PM2.5, PM10 and ozone. It is found that the impacts of air pollutants on natural ventilation are usually higher in urban/suburban areas than rural areas (up to 25% difference) with the PM2.5 being the most significant outdoor air pollutant affecting natural ventilation usage. Furthermore, ozone could become increasingly influential on natural ventilation as moving from urban to suburban/rural areas. As to the cooling energy saving considering the impacts of outdoor air pollutants, natural ventilation is estimated to save approximately 10%–40% cooling energy (800–2600 kWh per small commercial building) annually in different location settings of investigated areas across the US. The following economic analysis demonstrates that these electricity savings lead to approximately 80–540 dollars annual savings of building operation cost per building. If the time of use rate is adopted, these cost savings could further increase by approximately 20% (Los Angeles) to more than 50% (Albuquerque) depending on different rate structures, which further demonstrates the potential of adopting natural ventilation as a sustainability measurement with benefits for building owners without compromising occupants health.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of HVAC operation strategies for office buildings during COVID-19 pandemic

To minimize the indoor transmission of contaminants, such as the virus that can lead to COVID-19, buildings must provide the best indoor air quality possible. Improving indoor air quality can be achieved through the building's HVAC system to decrease any concentration of indoor contaminants by dilution and/or by source removal. However, doing so has practical downsides on the HVAC operation that are not always quantified in the literature. This paper develops a temporal simulation capability that is used to investigate the indoor virus concentration and operational cost of an HVAC system for two mitigation strategies: (1) supplying 100% outdoor air into the building and (2) using different HVAC filters, including MERV 10, MERV 13, and HEPA filters. These strategies are applied to a hypothetical medium office building consisting of five occupied zones and located in a cold and dry climate. We modeled the building using the Modelica Buildings library and developed new models for HVAC filtration and virus transmission to evaluate COVID-19 scenarios. We show that the ASHRAE-recommended MERV 13 filtration reduces the average virus concentration by about 10% when compared to MERV 10 filtration, with an increase in site energy consumption of about 3%. In contrast, the use of 100% outdoor air reduces the average indoor concentration by about an additional 1% compared to MERV 13 filtration, but significantly increases heating energy consumption. Use of HEPA filtration increases the average indoor concentration and energy consumption compared to MERV 13 filtration due to the high resistance of the HEPA filter.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Influence of design and operating parameters for additively manufactured intensified packing devices on CO 2 -Absorption column cooling and capture efficiency

Solvent-based CO 2 absorption is technologically a matured CO 2 capture pathway but suffers from: high regeneration energy demand, and solvent temperature rise and decreased capture efficiency caused by the heat of reaction. While research has focused on developing non-aqueous and low-aqueous solvents for decreasing the regeneration energy, the temperature bulge due to exothermic absorption is typically dealt with by cooling the solvent with an external inter-stage heat-exchanger. This approach may increase the overall process footprint, as well as capital and operating costs. Here, the current study explores a process intensification approach by incorporating inside the column an additively manufactured intensified packing device that consists of corrugated plates and internal coolant channels. The corrugated plates provide surface area for mass transfer between gas and liquid, while cooling fluid inside the internal channels removes heat from the exothermic reactive system. Two different intensified devices with specific surface areas of 266 m 2 /m 3 and 359 m 2 /m 3 were designed, manufactured, and tested inside a 2.06-m long and 0.203-m diameter column packed with commercial Mellapak 250Y packing. The device with a lower surface area showed up to 27 % reduction in cooling performance. A steady-state heat transfer model provides good agreement with the experimental column temperature and intra-stage heat removal data. Although a decrease in heat transfer performance was observed for the device with lower surface area, CO 2 capture experiments performed with simulated flue gas and low-aqueous solvent demonstrated that both intensified devices lead to a similar improvement of 12 % in capture efficiency. This study provides an understanding on simplifying the intensified packing device geometry and decreasing the device fabrication cost by 25 % without compromising with the CO 2 absorption performance of the packed column.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of H 2 O on the ethylene glycol/alkali dismantling of bagasse for high-value conversion

Using a high-boiling alcohol system to dismantle main components of biomass is a feasible technology. Reducing dismantle operating costs and improving dismantle efficiency are essential for promoting the green, economical, and sustainable development of biomass refining. Therefore, based on the low cost and chemical properties of H 2 O at high temperature, the effects of different H 2 O dosages in NaOH-catalyzed ethylene glycol (HBAA) system on the dismantling efficiency of bagasse, surface lignin coverage, recovered-lignin activity and enzymatic hydrolysis efficiency were investigated. Compared with the HBAA dismantling system without H 2 O, the HBAA system with 60% w/v H 2 O can obviously increase the removal rates of lignin and hemicellulose, while recovering up to 99% of cellulose and significantly declining surface lignin coverage, thus enhancing the enzymatic hydrolysis efficiency. Additionally, the results of density functional theory calculations and 2D HSQC NMR analysis prove that the synergy between H 2 O and ethylene glycol can promote the esterification reaction occurrence at the α-C carbon cation in β-O-4 structure of lignin, thereby protecting the β-O-4 aromatic ether bond. Simultaneously, when the H 2 O dosage increase from 0% to 60%, the enzymatic yield increases from 84.51% to 93.74% with an enzyme load of 10 FPU/g. Based on experimental results, this study conducted a techno-economic analysis of bagasse dismantling for ethanol and co-production of lignin, achieving a minimum ethanol selling price of $\$$1.07 per kg. Here, in this study, a green and economical solution for dismantling the main components of bagasse is developed, which is important for the high-value conversion of bagasse.

Ethylene glycol↗

Targeted electrochemical reduction of carcinogenic N -nitrosamines from emission control systems within CO 2 capture plants

N-Nitrosamines are one of the environmentally significant byproducts from aqueous amine-based post-combustion carbon capture systems (CCS) due to their potential risk to human health. Safely mitigating nitrosamines before they are emitted from these CO 2 capture systems is therefore a key concern before widescale deployment of CCS can be used to address worldwide decarbonization goals. Electrochemical decomposition is one viable route to neutralize these harmful compounds. The circulating emission control waterwash system, commonly installed at the end of the flue gas treatment trains to minimize amine solvent emissions, plays an important role to capture N-nitrosamines and control their emission into the environment. The waterwash solution is the last point where these compounds can be properly neutralized before becoming an environmental hazard. In this study, the decomposition mechanisms of N-nitrosamines in a simulated CCS waterwash with residual alkanolamines was investigated using several laboratory-scale electrolyzers utilizing carbon xerogel (CX) electrodes. Hcell experiments revealed that N-nitrosamines were decomposed through a reduction reaction and are converted into their corresponding secondary amines thereby neutralizing their environmental impact. Batch-cell experiments statistically examined the kinetic models of N-nitrosamine removal by a combined adsorption and decomposition processes. The cathodic reduction of the N-nitrosamines statistically obeyed the first-order reaction model. Finally, a prototype flow-through reactor using an authentic waterwash was used to successfully target and decompose N-nitrosamines to below the detectable level without degrading the amine solvent compounds allowing them to be return to the CCS and lower the system operating costs. Furthermore, the developed electrolyzer was able to efficiently remove greater than 98% of N-nitrosamines from the waterwash solution without producing any additional environmentally harmful compounds and offers an effective and safe route to mitigate these compounds from CO 2 capture systems.

20 FOSSIL-FUELED POWER PLANTS↗

Shared automated vehicle fleet operations for first-mile last-mile transit connections with dynamic pooling

Shared automated vehicles (SAVs) have the potential to promote transit ridership by providing efficient first-mile last-mile (FMLM) connections through reduced operational costs to fleet providers and lower out-of-pocket costs to riders. To help plan for a future of integrated mobility, this paper investigates the impacts of SAVs serving FMLM connections, as a mode that provides flexibility in access/egress decisions and is well coordinated with train station schedules. To achieve this objective, a novel dynamic pooling algorithm was introduced to match SAVs with riders while coordinating the riders' arrival times at the light-rail station to a known train schedule. Microsimulations of SAVs and travelers throughout two central Austin neighborhoods show how larger service areas, higher levels of SAV demand, and longer arrival times between successive trains require larger SAV fleet sizes and higher SAV utilization rates to deliver close traveler wait times. Four-person SAVs appear to perform similar to 6-seat SAVs but will cost less to provide. Using a dynamic pooling algorithm tightly coordinated with train arrivals (every 15 min) delivers 87% of travelers to their stations in time to catch the next train, whereas uncoordinated assignments deliver just 58% of travelers in time.

33 ADVANCED PROPULSION SYSTEMS↗

Resource distribution under spatiotemporal uncertainty of disease spread: Stochastic versus robust approaches

We consider the problem of optimizing locations of distribution centers (DCs) and plans for distributing resources such as test kits and vaccines, under spatiotemporal uncertainties of disease spread and demand for the resources. We aim to balance the operational cost (including costs of deploying facilities, shipping, and storage) and quality of service (reflected by demand coverage), while ensuring equity and fairness of resource distribution across multiple populations. We compare a sample-based stochastic programming (SP) approach with a distributionally robust optimization (DRO) approach using a moment-based ambiguity set. Numerical studies are conducted on instances of distributing COVID-19 vaccines in the United States and test kits, to compare SP and DRO models with a deterministic formulation using estimated demand and with the current resource distribution plans implemented in the US. We demonstrate the results over distinct phases of the pandemic to estimate the cost and speed of resource distribution depending on scale and coverage, and show the “demand-driven” properties of the SP and DRO solutions. Furthermore, our results further indicate that if the worst-case unmet demand is prioritized, then the DRO approach is preferred despite of its higher overall cost. Nevertheless, the SP approach can provide an intermediate plan under budgetary restrictions without significant compromises in demand coverage.

97 MATHEMATICS AND COMPUTING↗

Desalination metamodels and a framework for cross-comparative performance simulations

There is an opportunity to save energy and reduce operational expenses when choosing a suitable desalination method aided by computational modeling. Existing models are not conducive to generalized comparisons between different desalination methods. Therefore, the work in this study developed metamodels for six desalination methods, grouped them into thermal and molecular transport families, and validated their predictive performance within 9% difference from published data. This validated framework allowed comparisons of desalination methods at their prescribed ranges of operational conditions that they were designed for. These conditions specify feed salinity ranges of 1.6 to 2.4 g/kg for Capacitive Deionization and Reverse Osmosis (RO), 2.8 to 4.2 g/kg for Electrodialysis, 28 to 42 g/kg for Thermovapor Compression and Humidification-Dehumidification, and 37 to 55 g/kg for Multi-Effect Distillation (MED). Despite different operational conditions, all models exhibit non-linear, positive correlation between energy consumption and system size in response to feed salinity and production rate. The framework is also employed in a cross-comparative analysis between MED and RO whose results suggest that energy intensity for MED is an order of magnitude greater than RO for the same operational conditions, but actual operational costs are comparable. Overall, the framework is ready for deployment in case studies of actual desalination plants.

42 ENGINEERING↗

Residential Demand Flexibility: Modeling Occupant Behavior using Sociodemographic Predictors

Demand flexibility (DF) has the potential to increase the saturation of renewables in the grid and reduce operating costs for both utilities and customers. However, less than 8% of U.S. residential electric customers are enrolled in DF programs. A major research gap on this topic is an uneven understanding of behavioral drivers of electricity use and DF program participation at the household level. In this study, we employ machine learning models to predict residential occupant behavior in activities relevant to DF. We model occupants' extensive decisions (i.e., choice of action) and intensive behaviors (i.e., amount of time spent) during peak and off-peak time periods using the publicly available American Time Use Survey, which includes activities data for approximately 200,000 respondents. In our machine learning models, predictions for both extensive and intensive behavior fell within a +/-20% error margin at the aggregate level. We identify 13 key sociodemographic predictors of DF-related intensive behavior using LASSO inference and beta coefficient ranking. However, these top predictors differ by activity, suggesting potential scope for differential user targeting for DF events and technologies during program design. This work also contributes to understanding when and who might adopt these DF technologies based on their daily routine activities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗