Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “memory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Efficient implementation of a multidimensional fast fourier transform on a distributed-memory parallel multi-node computer

The present in invention is directed to a method, system and program storage device for efficiently implementing a multidimensional Fast Fourier Transform (FFT) of a multidimensional array comprising a plurality of elements initially distributed in a multi-node computer system comprising a plurality of nodes in communication over a network, comprising: distributing the plurality of elements of the array in a first dimension across the plurality of nodes of the computer system over the network to facilitate a first one-dimensional FFT; performing the first one-dimensional FFT on the elements of the array distributed at each node in the first dimension; re-distributing the one-dimensional FFT-transformed elements at each node in a second dimension via "all-to-all" distribution in random order across other nodes of the computer system over the network; and performing a second one-dimensional FFT on elements of the array re-distributed at each node in the second dimension, wherein the random order facilitates efficient utilization of the network thereby efficiently implementing the multidimensional FFT. The "all-to-all" re-distribution of array elements is further efficiently implemented in applications other than the multidimensional FFT on the distributed-memory parallel supercomputer.

97 MATHEMATICS AND COMPUTING↗

Magnetic Resonance Flow Velocity and Temperature Mapping of a Shape Memory Polymer Foam Device

Interventional medical devices based on thermally responsive shape memory polymer (SMP) are under development to treat stroke victims. The goals of these catheter-delivered devices include re-establishing blood flow in occluded arteries and preventing aneurysm rupture. Because these devices alter the hemodynamics and dissipate thermal energy during the therapeutic procedure, a first step in the device development process is to investigate fluid velocity and temperature changes following device deployment. A laser-heated SMP foam device was deployed in a simplified in vitro vascular model. Magnetic resonance imaging (MRI) techniques were used to assess the fluid dynamics and thermal changes associated with device deployment. Spatial maps of the steady-state fluid velocity and temperature change inside and outside the laser-heated SMP foam device were acquired. Though non-physiological conditions were used in this initial study, the utility of MRI in the development of a thermally-activated SMP foam device has been demonstrated.

42 ENGINEERING↗

Structural Phase Transitions between Layered Indium Selenide for Integrated Photonic Memory

The primary mechanism of optical memoristive devices relies on phase transitions between amorphous and crystalline states. The slow or energy-hungry amorphous–crystalline transitions in optical phase-change materials are detrimental to the scalability and performance of devices. Leveraging an integrated photonic platform, nonvolatile and reversible switching between two layered structures of indium selenide (In 2 Se 3 ) triggered by a single nanosecond pulse is demonstrated. The high-resolution pair distribution function reveals the detailed atomistic transition pathways between the layered structures. With interlayer “shear glide” and isosymmetric phase transition, switching between the α- and β-structural states contains low re-configurational entropy, allowing reversible switching between layered structures. Broadband refractive index contrast, optical transparency, and volumetric effect in the crystalline–crystalline phase transition are experimentally characterized in molecular-beam-epitaxy-grown thin films and compared to ab initio calculations. Finally, the nonlinear resonator transmission spectra measure of incremental linear loss rate of 3.3 GHz, introduced by a 1.5 µm-long In 2 Se 3 -covered layer, resulted from the combinations of material absorption and scattering.

36 MATERIALS SCIENCE↗

Ion beam etching dependence of spin-orbit torque memory devices with switching current densities reduced by Hf interlayers

We report on the fabrication of nanoscale, three-terminal in-plane spin–orbit torque switching devices with low switching current densities. Critical parameters in the fabrication process, including the ion beam etching angle and time, were optimized to avoid fabrication defects and improve device yield. Measurements of the magnetic field and current-induced switching behavior of the tunnel junctions demonstrate a sensitivity to the nanopillar aspect ratio, which dictates the nanopillars’ anisotropy and thermal stability. Additionally, we show that the current density required for switching can be reduced and the device thermal stability increased by inserting Hf interlayers into the heterostructure. Micromagnetic simulations are generally consistent with the experimentally observed switching behavior, suggesting an increase in the interfacial perpendicular anisotropy at the CoFeB/MgO interface and the reduction in the Dzyaloshinskii–Moriya interaction at the W/CoFeB interface by the Hf interlayers.

36 MATERIALS SCIENCE↗

Two–Photon Polymerized Shape Memory Microfibers: A New Mechanical Characterization Method in Liquid

Two-photon polymerization (TPP) is widely used to create 3D micro- and nanoscale scaffolds for biological and mechanobiological studies, which often require the mechanical characterization of the TPP fabricated structures. To satisfy physiological requirements, most of the mechanical characterizations need to be conducted in liquid. However, previous characterizations of TPP fabricated structures are all conducted in air due to the limitation of conventional micro- and nanoscale mechanical testing methods. In this study, a new experimental method is reported for testing the mechanical properties of TPP-printed microfibers in liquid. The experiments show that the mechanical behaviors of the microfibers tested in liquid are significantly different from those tested in air. By controlling the TPP writing parameters, the mechanical properties of the microfibers can be tailored over a wide range to meet a variety of mechanobiology applications. In addition, it is found that, in water, the plasticly deformed microfibers can return to their predeformed shape after tensile strain is released. The shape recovery time is dependent on the size of microfibers. The experimental method represents a significant advancement in mechanical testing of TPP fabricated structures and may help release the full potential of TPP fabricated 3D tissue scaffolds for mechanobiological studies.

36 MATERIALS SCIENCE↗

Context-aware quantum simulation of a matrix stored in quantum memory

In this paper, a storage method and a context-aware circuit simulation idea are presented for the sum of block diagonal matrices. Additionally, using the design technique for a generalized circuit for the Hamiltonian dynamics through the truncated series, we generalize the idea to (0–1) matrices and discuss the generalization for the real matrices. The presented circuit requires O(n) number of quantum gates and yields the correct output with the success probability depending on the number of elements: For matrices with poly(n), the success probability is 1 / poly(n). Since the operations on the circuit are controlled by the data itself, the circuit can be considered as a context-aware computing gadget. In addition, it can be used in variational quantum eigensolver and in the simulation of molecular Hamiltonians.

97 MATHEMATICS AND COMPUTING↗

Protective Properties of Aluminum Nitride Coatings by DC-PVD Sputtering on Cu-10Al-13Mn Shape Memory Alloy

The AlN coating was applied on the surface of a Cu-10Al-13Mn alloy using the DC-PVD sputtering method. The substrate was set at three different temperatures which were ambient, 100 and 200 °C. The effect of the substrate temperature on the quality of AlN coating was modeled by simulating stress on the coating and substrate. The preparation, microstructure, and corrosion resistance of the coating were studied. The surface morphology and element distribution of the coating were investigated by scanning electron microscopy (SEM) and energy distribution spectroscopy (EDS), respectively. In addition, the corrosion resistance of coating was measured using electrochemical impedance spectroscopy (EIS) method in 1 M NaCl solution. The results showed that the AlN coating was formed on the Cu-10Al-13Mn alloy by DC-PVD sputtering method and the AlN coating considerably improved the corrosion resistance of Cu-10Al-13Mn alloy in the given corrosive media. According to EIS test, polarization resistance increased from approximately 1.6 to 115 KΩ, at 200 °C for uncoated and coated samples, respectively. Thus, corrosion resistance of AlN coating improved with the increase in the substrate temperature during the DC-PVD sputtering process.

36 MATERIALS SCIENCE↗

Stability of Phase Transformation Temperatures During Cycling of Ti-15.8Nb-4.94Al-0.06Sc Shape Memory Alloy

The active ω phase formation decreases the martensitic transformation temperatures sharply and can even suppress the martensitic transformation during thermal cycling in Ti-Nb-based alloys. No ω phase is observed in the present Ti-15.8Nb-4.94Al-0.06Sc alloy when it is annealed at 650 °C for 4 h or subsequently aged at 200 and 250 °C for 2 h. The exclusion of ω phase remarkably improves the stability of phase transformation temperatures during thermal cycling. The martensitic transformation start temperature of the present alloy decreases by 30 °C but tends to be stable gradually during the 20 thermal cycles, owing to the saturation of lattice defects.

36 MATERIALS SCIENCE↗

Effects of Heat Input on Weld-Bead Geometry, Surface Chemical Composition, Corrosion Behavior and Thermal Properties of Fiber Laser-Welded Nitinol Shape Memory Alloy

Bead-on-plate laser welding was carried out on 1-mm-thick Nitinol sheets at different heat input values. The variations in weld-bead geometry and variations in microstructures across the bead were studied. The effects of heat input on surface layer composition of the welded samples, corrosion properties and phase transformation temperature were examined. From x-ray photoelectron spectroscopy (XPS), it was clear that relative intensity of elemental Ni peak was higher in parent material and the oxidation state of Ti was Ti{sup 4+}. It was further observed from Auger electron spectroscopy (AES) that the Ti to Ni ratio on the top surface of the welded samples was more than 1, and as a result of this the stability of TiO{sub 2} layer was enhanced, which eventually helped to improve the corrosion property of the welded samples. The polarization resistance of the welded samples was increased by more than ten times compared to that of the un-welded samples. From differential scanning calorimetry (DSC), it became evident that phase transformation temperatures got changed due to welding.

36 MATERIALS SCIENCE↗

On the fast kinetics of B2–L2 1 ordering in Ni-Co-Mn-In metamagnetic shape memory alloys

B2–L2 1 configurational order resulting from thermal processing of Ni-Co-Mn-In Heusler alloys is one of the main factors defining the characteristics of the martensitic transformation experienced by these alloys. While the effects of the quenched-in disorder on the martensitic transformation have been extensively investigated, the kinetics of the ordering process is not well known and mostly inferred from the indirect results such as the dependence of the martensitic transformation or magnetic transition temperatures to thermal processing. However, recent results suggested that the kinetics of B2– L 2 1 ordering could have a more significant role than expected in the final state of the material and its functional properties. In the current work, an attempt has been made to investigate the kinetics of B2–L2 1 ordering in order to evaluate the dependence of the quenched-in disorder on the different variables of the thermal procedures. Results showed that ordering rate has a strong dependence on annealing temperature. Below 600 K, slow kinetics is forcing the crystal to always contain a certain amount of quenched-in disorder at room temperature. Between 600 K and 750 K, kinetics is fast enough to reach thermal equilibrium state within tens of minutes during the annealing process. Above 750 K, kinetics is very fast and thermal equilibrium can be reached during heating, so no isothermal holding is required. Furthermore, these predictions have been confirmed using differential scanning calorimetry and in-situ high-energy X-Ray diffraction measurements for non-direct estimations of the degree of order.

36 MATERIALS SCIENCE↗

Switching current reduction in magnetoresistive random access memories

We present an approach for minimizing the critical current for the magnetization switching in magnetic tunnel junctions by optimizing the spatial distribution of the current density. We show that such a minimization is possible because critical current is determined by the condition of making one of the magnetization eigenstates grow in time. The excitation of the eigenstates is enhanced when the spatial distributions of the eigenstates and current density overlap. Critical current can be viewed as a functional of the current density spatial distribution and it can be minimized by optimizing this distribution. Such an optimization results in a major reduction of the critical current and increase of the switching efficiency, viz. the ratio between the energy barrier and critical current. The minimized critical current increases approximately linearly with the magnetic tunnel junction size, which is much slower than critical current for the case of a uniform current density. The optimized efficiency can be approximately a constant with respect to the magnetic tunnel junction size, which is much higher than the efficiency for the uniform current density. Additional optimization can be achieved by spatially modulating the material parameters, e.g., the saturation magnetization. The presented approach and obtained scaling of the critical current and efficiency offers opportunities for the magnetic tunnel junction optimization.

36 MATERIALS SCIENCE↗

The characterization of shape memory effect for low elastic modulus biomedical {beta}-type titanium alloy

This work investigates the textures of biomedical TiNbTaZr alloy rolled by 99% cold reduction ratios in thickness. The relationship between textures and superelasticity of the specimens treated at 873 K and 1223 K for 1.2 ks is studied. The microstructure of tensile specimen is investigated by transmission electron microscopy. Textures of cold-rolled and heat-treated specimens are studied. During unloading, the anisotropy of superelastic strain and pure elastic strain in the heat-treated specimens is observed. Superelastic strain along rolling direction and transverse direction is larger than those along 45 deg. from rolling direction while pure elastic strain shows the highest value along 45 deg. from rolling direction in the specimen treated at 873 K. For the specimen treated at 1223 K, higher pure elastic strain is obtained along rolling direction. The maximum recovered strain around 2.11% is obtained along rolling direction.

36 MATERIALS SCIENCE↗