Molybdenum-99 Production via Fissile Solution Reactor and Electron Beam Accelerator
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The Transient Reactor Test (TREAT) Facility is an air-cooled reactor composed of graphite-urania fuel encapsulated in zirconium alloy canisters and surrounded by ~2 ft (~61 cm) of nuclear grade graphite. The primary role of TREAT is to provide in-pile nuclear-heated safety research via transient testing [1]. Benchmark efforts have demonstrated sensitivity of TREAT neutronics models to graphite cross section data and key neutron poisons found in the fuel assemblies [2]. During fabrication of TREAT fuel assemblies, a small concentration of boron was inadvertently introduced with variable concentration into the aggregate of fuel blocks prepared for TREAT use. The concentration of boron, and its respective uncertainty, represent the most sensitive component in a neutronics study; unfortunately, nothing can be done to reduce or otherwise mitigate its impact. Hydrogen in the fuel blocks reduces the mean free path of the core and its true quantity and uncertainty is approximated. The hydrogen remains from pitch binder used in the fuel fabrication process and was not completely released due to incomplete fuel graphitization. Destructive fuel testing is necessary to quantify the actual hydrogen content and to improve benchmark model quality. A third neutron poison of some significance is the hafnium impurity in the Zircaloy-3 (Zry-3) assembly cladding. The quantity of hafnium is expected to be within nominal manufacturing limits for nuclear grade zircaloy. Recladding the fuel assemblies with material that is less neutron absorbing is expected to benefit reactor neutron economy. Moreover, TREAT’s total transient energy is restricted based on the rate of Zry-3 oxidation in TREAT’s air coolant environment. Hence, cladding with more benign air reaction kinetics could dramatically uprate the facility’s experimental capability. Silicon carbide (SiC) has been proposed as a candidate material for recladding TREAT assemblies, as SiC/SiC demonstrate favorable properties within nuclear environments [3]. The current operational limits of TREAT are restricted by the oxidation of Zry-3. Change of the cladding to SiC could feasibly double the current temperature limitation. Recladding opportunities allow for previously damaged fuel assemblies to be returned to service, as Zry-3 is not commercially available. The initial effort required to consider proceeding with any recladding effort is to neutronically characterize key reactor parameters while replacing Zry-3 with SiC. A characterization summary, with respective results, is provided herein.
The Transient Reactor Test (TREAT) Facility is an air-cooled reactor composed of graphite-urania fuel encapsulated in zirconium alloy canisters and surrounded by ~2 ft (~61 cm) of nuclear grade graphite. The primary role of TREAT is to provide in-pile nuclear-heated safety research via transient testing [1]. The following work represents further analyses building upon previously reported work to support larger volume test vehicles within TREAT [2]. The Broad Use Specimen Transient Experiment Rig (BUSTER) provides ample versatility for numerous transient test concepts. However, future testing and experiment needs will require testing environments of different in-core footprints. The versatility of TREAT allows for the development of variegated core layouts with key limitations emplaced as operational safety temperature restrictions and available core reactivity. The focus of this current effort is to gauge core arrangements for TREAT core loadings to support centralized experimental testing of varying dimensional capacity. The total core excess reactivity (ER) was computed for different arrangements to establish comparison tables that enable ready assessment of core ER available for future experiment concepts. Test vehicle worths would then be necessary to establish available ER to support transient testing requirements and to perform reactor performance and safety calculations [3,4].
Explore the source record for details and available documents.
Nuclear criticality experiments are used to validate nuclear cross section data used by simulation software. This is typically achieved by designing a critical system with a high sensitivity to a certain material’s cross section. Once the experiment has been carried out, a high fidelity model of the system is developed into a benchmark. When this benchmark model is simulated by a transport code, some of the difference between the experimental and computational effective neutron multiplication factor can be attributed to inaccurate nuclear data. Nuclear data evaluators then can make adjustments accordingly to improve cross section data.
Explore the source record for details and available documents.
Los Alamos National Laboratory has been performing nuclear criticality experiments since 1946 at the Pajarito site, starting the Los Alamos Critical Experiments Facility in 1948. A transition period occurred between 2004 and 2011 as operations moved to the National Criticality Experiments Research Center (NCERC), where criticality experiments are now performed. Criticality experiments are essential for determination and verification of nuclear data used in calculations and modeling—such as radiation transport codes—throughout the industry, enhancing nuclear criticality safety. In addition to nuclear data validation and benchmarking, the remotely operated critical assemblies at NCERC are used for a variety of experiments and training classes supporting criticality safety.
The Measurement of Uranium Subcritical and Critical (MUSiC) experiment was carried out from December 2020 through April 2021 at the National Criticality Experiments Research Center (NCERC). This measurement campaign featured bare configurations of the Rocky Flats highly-enriched uranium (HEU) shells, with each configuration having different numbers of these shells. The goal of the experiment was to test multiple neutron multiplicity detectors and measurement methods for a large range of neutron multiplication values. The large range of multiplications allows researchers to see when the combination of detectors and methods break down as the configurations reach the delayed supercritical window. The critical configurations were the extreme end of the multiplication range in MUSIC configurations. A critical benchmark in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook is planned to help further validate nuclear data. Even though there are many benchmarks focusing on the fast spectrum for highly-enriched uranium, an additional benchmark that is well documented and up to the modern standard of the handbook would be a welcome addition. Given that there are no other materials such as moderators or significant reflectors, and its similarity to Lady Godiva, it is possible that this could be very useful for validation of 235 U nuclear data in the future.
The typical goal of designing a critical experiment is twofold: a system that is both critical and optimized for some other value. This value could be an energy-integrated sensitivity, percent fissions in a certain energy range, or some other value that can be calculated by a transport code. By simulating different combinations of reflector, moderator, and fuel thicknesses a designer can identify such a desirable configuration. The domain of all possible combinations of these thicknesses is referred to as the experiment search space. As more dimensions are added, the search space increases in size exponentially. For a three-dimensional case, which includes three thickness values between zero and ten centimeters to the nearest tenth of a millimeter, a total of 1,000 3 , configurations exists. Rather than check each configuration individually, which would be extremely computationally expensive, it has been shown to be more efficient to use a conventional particle swarm optimization (PSO) algorithm to identify critical and optimal configurations. This work presents the theory and implementation of a novel hybrid PSO interpolation algorithm to perform these optimizations faster than a conventional PSO algorithm. To demonstrate this, an example optimization will be carried out by the conventional and hybrid PSO algorithms and their performances will be compared.
For the past seven decades the Lady Godiva benchmark (HEU-MET-FAST-001) has been the primary experiment used for 235 U nuclear data validation. The papers associated with large nuclear data library releases such as ENDF/B-VII.1 and ENDF/B-VIII.0 refer to it frequently. The reasons why HEU-MET-FAST-001 has been used as the primary validation experiment for 235 U nuclear data validation will be discussed in the following section. However, as discussed among the benchmark community, the standards associated with International Criticality Safety Benchmark Evaluation Project (ICSBEP) evaluations have changed throughout time; this is subject of the OECD/NEA WPEC (Working Party on Nuclear Criticality Safety) Subgroup 8. HEU-MET-FAST-001 is an older benchmark (issued during the inaugural year of ICSBEP in 1996 with only minor revisions occurring since then) and (along with many of the other benchmarks from this era) does not meet the standards for a modern benchmark. This work explores why HEU-MET-FAST-001 is useful for 235 U nuclear data validation and discusses other alternative validation experiments.
Neutron leakage spectra have been measured, simulated, and investigated by many groups. These spectra have many uses, including determining shielding requirements and calculating dose for radiation protection purposes, validating nuclear data, and determining material composition. It has even been proposed to use measurements of neutron leakage spectra to determine the soil composition of Mars. As part of the Los Alamos National Laboratory (LANL) Experiments Underpinned by Computational Learning for Improvements in nuclear Data (EUCLID) Laboratory Directed Research Development (LDRD) project, the authors are working on developing methods to calculate sensitivities to neutron leakage spectra. This may allow nuclear data evaluators to better use neutron leakage spectra data to constrain or adjust nuclear data. This may also be particularly useful as many neutron leakage spectra measurements do not require fissile material and can be performed with well characterized neutron sources. Neutron leakage spectra measurements are usually performed by placing a detector at the outside of a nuclear system. This may be a reactor, a neutron generator, or a neutron source. Certain detection systems can use pulse height data to infer neutron energies, other detector systems rely on other ways of determining neutron energy (for example, a Bonner sphere with multiple moderator thicknesses can be used to measure neutron spectrum). These measurements typically rely on some unfolding of the measured results. For pulsed systems like the "Livermore Pulsed Spheres," time-of-flight information can also help to constrain the neutron energy spectra data.
The purpose of a nondestructive assay is to accurately verify the declared mass of special nuclear material (SNM) samples in a limited amount of time. One measurement modality is neutron multiplicity counting (NMC), which relates time-correlated neutron detection rates to the mass of SNM present. Traditional theory assumes point-like sources, which can be ill-posed for kilogram-quantity, bulk samples. Recent theory was developed to improve NMC accuracy for non-point-like samples. This work preliminarily examines the theory with measured data. The OSCAR prototype (a 3-by-4 array of 5.08-cm-thick, 5.08-cm-diameter trans-stilbene organic scintillators) measures configurations of 29.41-49.00 kg of highly enriched uranium (93wt% 235 U). Adjusted factorial moments for the emitted neutron multiplicity distributions are used to account for the shape and type of SNM being measured.
The International Criticality Safety Benchmark Evaluation Project (ICSBEP) was started in 1992 by the United States Department of Energy and later in 1995 became an international project with contributions from 22 countries. The project is now organized by the OECD (Organisation for Economic Co-operation and Development) Nuclear Energy Agency (NEA). In its most recent iteration, the ICSBEP handbook contains over five thousand evaluations of critical, near-critical, and subcritical experiments conducted in facilities all around the world. These benchmarks serve as valuable information for criticality safety engineers who can use them to validate calculation techniques and establish minimum subcritical margins for operations with fissionable materials. The benchmarks in the handbook are categorized by their fissile material composition, material form (oxide, solution, or metal), and fission energy spectra. This is especially useful for those looking for benchmarks similar to a system they are working on to compare methods and identify trends. The ICSBEP Handbook Uncertainty Guide is document outlining recommended practices and methods for determining uncertainties in these benchmarks. Quantifying these uncertainties thoroughly is crucial as it allows a higher degree of confidence that data used from them is valid and relevant. The guide stresses the importance of a thorough and well documented uncertainty analysis when evaluating an experiment. All measured values of a system, whether they be dimensions or material compositions, have a certain amount of uncertainty associated with them and can be analyzed one by one to determine their effects on the system. Many evaluated benchmarks in the handbook present this in detail, however some do not, mostly earlier evaluations performed in the 1990’s and early 2000’s. Recently at Los Alamos National Laboratory (LANL), the Nuclear Criticality Safety Division (NCSD) of LANL has been validating MCNP6.2 ® input files of criticality benchmarks for use by Whisper, a criticality safety code developed at LANL. This effort is also part of the OECD NEA Working Party on International Nuclear Data Evaluation Co-operation (WPEC) Subgroup 45, also known as Validation of Nuclear Data Libraries (VaNDaL). The goal of VaNDaL is to compile a set of validated simulation inputs for use in validating nuclear data and simulation codes. As part of these efforts, one of the benchmarks reviewed was the MIX SOL-THERM-003 ICSBEP benchmark. This paper provides an independent uncertainty analysis of this benchmark experiment.
Explore the source record for details and available documents.
The Department of Energy invests tens of millions of dollars each year to develop the next generation of nuclear engineering modeling & simulation (M&S) tools. These tools are used to analyze advanced reactor designs and the safety of current nuclear operations. As computers become more powerful, we are able to enhance resolution in our calculations. This improved resolution is taking us to a point where the limitations of simulation capability are in the quality of data, including our ability to quantify the uncertainty and sensitivity of the data. In order to model systems of interest with increasing accuracy, the industry must improve key nuclear data measurements. Thus, M&S tools need evaluated and quality-assured experimental data for validation purposes. The International Criticality Safety Benchmark Evaluation Project (ICSBEP) compiles and evaluates experiment data in a handbook that can be used by criticality safety engineers and others to validate computer codes and cross-section libraries at nuclear facilities. Both critical and subcritical experiments are included in the handbook. Figure 1 organizes all the benchmark evaluations that have been performed by the isotope of interest, in this case Pb, and the average neutron energy the system. Compared to other isotopes of interest for nuclear applications, there are few benchmark evaluations for Pb systems. The lack of integral measurements to determine errors in Pb cross-section data has caused the latest nuclear cross-section libraries to over/underestimate k eff compared to experimental results. Therefore, this evaluation fills an important knowledge gap in benchmark evaluations.
An experiment designed to compare neutron noise analysis techniques on subcritical assemblies using differing neutron detector designs was developed as a collaborative effort between the Institut de radioprotection et de surete nucleaire (IRSN), Los Alamos (LANL), Lawrence Livermore (LLNL), and Sandia National Laboratories. This experiment has the final goal of characterizing neutron noise analysis accuracy in determining multiplication in light water systems for various neutron detection systems. This experiment utilized the Seven Percent Critical Experiment (7uPCX) facility at Sandia National Laboratories. The 7uPCX is an assembly designed to investigate light water systems with fuel enrichment above 5% and is able to use square or hex grid plates with varying pitches.