Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Effective Cytotoxic T Lymphocyte Targeting of Persistent HIV-1 during Antiretroviral Therapy Requires Priming of Naive CD8 + T Cells

Curing HIV-1 infection will require elimination of persistent cellular reservoirs that harbor latent virus in the face of combination antiretroviral therapy (cART). Proposed immunotherapeutic strategies to cure HIV-1 infection include enhancing lysis of these infected cells by cytotoxic T lymphocytes (CTL). A major challenge in this strategy is overcoming viral immune escape variants that have evaded host immune control. Here we report that naive CD8 + T cells from chronic HIV-1-infected participants on long-term cART can be primed by dendritic cells (DC). These DC must be mature, produce high levels of interleukin 12p70 (IL-12p70), be responsive to CD40 ligand (CD40L), and be loaded with inactivated, autologous HIV-1. These DC-primed CD8 + T cell responders produced high levels of gamma interferon (IFN-γ) in response to a broad range of both conserved and variable regions of Gag and effectively killed CD4 + T cell targets that were either infected with the autologous latent reservoir-associated virus or loaded with autologous Gag peptides. In contrast, HIV-1-specific memory CD8 + T cells stimulated with autologous HIV-1-loaded DC produced IFN-γ in response to a narrow range of conserved and variable Gag peptides compared to the primed T cells and most notably, displayed significantly lower cytolytic function. Our findings highlight the need to selectively induce new HIV-1-specific CTL from naive precursors while avoiding activation of existing, dysfunctional memory T cells in potential curative immunotherapeutic strategies for HIV-1 infection.

59 BASIC BIOLOGICAL SCIENCES↗

Development and Characterization of a High-Solids Deacetylation Process

Dilute-acid pretreatment has proven to be a robust means of converting herbaceous feedstock to fermentable sugars. However, it also releases acetic acid, a known fermentation inhibitor, from acetyl groups present in the biomass. A mild, dilute alkaline extraction stage was implemented prior to acid pretreatment to separate acetic acid from the hydrolysate sugar stream. This step, termed deacetylation, improved the glucose and xylose yields from enzymatic hydrolysis and ethanol yields from fermentation of the sugars relative to the control experiments using dilute-acid pretreatment of native corn stover without deacetylation. While promising, deacetylation as it was historically practiced is conducted at low solids loadings, and at fixed conditions. Thus, many questions have been left unanswered, including the relationship between sodium hydroxide and solids loading, and acetate and xylan solubilization, as well as the impact of temperature and residence time on the process efficacy. A central composite experiment was designed to evaluate the impact of solids loading, sodium hydroxide loading, reaction time and temperature during deacetylation on the acetate and xylan solubilization of corn stover. Using the ANOVA test, it became apparent that neither of the responses was significantly impacted by the solids loading, while the reaction time was a minor factor - the responses were largely driven by reaction temperature and the sodium hydroxide loading. Based on the results, we successfully demonstrated the ability to transition the low-solids (10 % w/w) deacetylation process to a higher-solids process (30 % w/w) with minimal impact on the ability to extract acetate from biomass. Conditions were selected to minimize xylose loss during deacetylation, while also removing 70 % of acetyl groups. The impact of selected conditions on the enzymatic hydrolysis and fermentation was further investigated. In conclusion, evaluation of the whole-process impact demonstrated that despite the upfront reduction in carbohydrate loss during deacetylation, the overall process sugar yields were depressed by the high-solids, low alkali process relative to the historical control. Consequently, ethanol titers were reduced, though strong fermentation performance was still observed, indicating that 70 % acetate removal is sufficient to depress acetic acid concentrations to a level that does not substantially inhibit ethanol fermentation by rZymomo nas.

09 BIOMASS FUELS↗

Concepts for a theoretical and experimental study of lifting rotor random loads and vibrations (identification of lifting rotor system parameters from transient response data), Phase 7-B

System identification methods have been applied to rotorcraft to estimate stability derivatives from transient flight control response data. While these applications assumed a linear constant coefficient representation of the rotorcraft, the computer experiments used transient responses in flap-bending and torsion of a rotor blade at high advance ratio which is a rapidly time varying periodic system. It was found that a simple system identification method applying a linear sequential estimator also called least square estimator or equation of motion estimator, is suitable for this periodic system and can be used directly if only the acceleration data are noise polluted. In the case of noise being present also in the state variable data the direct application of the estimator gave poor results.

Hohenemser, K. H.↗

Coupled elastic response of open section laminated composite beams subject to generalized beam loading

A generalized beam theory for arbitrary open section laminated composite beams subjected to generalized beam loading is developed using a strength of materials approach. At present, the theory is limited to statistically determinate beams. Solution of the general system of equations yields strain and curvature distributions as functions of the axial coordinate x and the contour coordinate s. Average stresses on a given cross section or ply stresses in a local coordinate system are determined using these distributions. Data obtained for thin-walled open section composite beams reveal that elastic coupling occurs among curvatures, shearing strains, and axial strain, depending on the laminate stiffness parameters. Laminate ply layup does not affect the location of the shear center in the thin-wall approximation, but may have a significant impact for thicker walled open sections. The average axial stress distribution is found to be distinctly different from the isotropic distribution, but the average shear stress distribution is the same as that in the isotropic case.

Zvarick, Albert G.↗

DetSuM: Detector Surrogate Model for LArTPC

In large neutrino experiments such as the Deep Underground Neutrino Experiment (DUNE), estimating detector response uncertainties typically requires simulation samples that consume substantial computing resources and time. To mitigate this challenge, we present DetSuM, an uncertainty-aware surrogate model designed to capture the detector response variations with reduced computing load compared to full simulations. This poster describes the construction and evaluation of DetSuM using simulation and reconstruction datasets in a rare-event search at DUNE. We assess DetSuM's ability to predict key detector-response variations and their associated uncertainties, discuss current limitations, and outline improvements to extend its validity in systematics studies of DUNE physics.

Li, Aobo [UC, San Diego]↗

Individual Differences in the Temporal Profile of Cardiovascular Responses to Head Down Tilt and Orthostatic Stress with and Without Fluid Loading

Susceptibility of healthy astronauts to orthostatic hypotension and presyncope is exacerbated upon return from spaceflight. Hypo-volemia is suspected to play an important role in cardiovascular deconditioning following exposure to spaceflight, which may lead to increased peripheral resistance, attenuated arterial baroreflex, and changes in cardiac function. The effect of altered gravity during space flight and planetary transition on human cardiovascular function is of critical importance to maintenance of astronaut health and safety. A promising countermeasure for post-flight orthostatic intolerance is fluid loading used to restore loss fluid volume by giving crew salt tablets and water prior to re-entry. Eight men and eight women will be tested during two, 6-hour exposures to 6o HDT: 1) fluid loading, 2) no fluid loading. Before and immediately after each HDT, subjects will perform a stand test to assess their orthostatic tolerance. Physiological measures (e.g., ECG, blood pressure, peripheral blood volume) will be continuously monitored while echocardiography measures are recorded at 30-minute intervals during HDT and stand tests. Preliminary results (N=4) clearly show individual differences in responses to this countermeasure and the time course of physiological changes induced by HDT.

Cowings, Patricia↗

Charge transport model in nanodielectric composites based on quantum tunneling mechanism and dual-level traps

Charge transport properties in nanodielectrics present different tendencies for different loading concentrations. The exact mechanisms that are responsible for charge transport in nanodielectrics are not detailed, especially for high loading concentration. A charge transport model in nanodielectrics has been proposed based on quantum tunneling mechanism and dual-level traps. In the model, the thermally assisted hopping (TAH) process for the shallow traps and the tunnelling process for the deep traps are considered. For different loading concentrations, the dominant charge transport mechanisms are different. The quantum tunneling mechanism plays a major role in determining the charge conduction in nanodielectrics with high loading concentrations. While for low loading concentrations, the thermal hopping mechanism will dominate the charge conduction process. The model can explain the observed conductivity property in nanodielectrics with different loading concentrations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Uncertainty and Risk Assessment in the Design Process for Wind

This report summarizes the concepts and opinions that emerged from an initial study on the subject of uncertainty in wind design that included expert elicitation during a workshop held at the National Wind Technology Center at the National Renewable Energy Laboratory July 12-13, 2016. In this paper, five major categories of uncertainties are identified. The first category is associated with direct impacts on turbine loads, (i.e., the inflow including extreme events, aero-hydro-servo-elastic response, soil-structure inter- action, and load extrapolation). The second category encompasses material behavior and strength. Site suitability and due-diligence aspects pertain to the third category. Calibration of partial safety factors and optimal reliability levels make up the fourth one. And last but not least, is the category associated with uncertainties in computational modeling. The main sections of this paper follow this organization.

17 WIND ENERGY↗

Automatic generation and analysis of solar cell IV curves

A photovoltaic system includes multiple strings of solar panels and a device presenting a DC load to the strings of solar panels. Output currents of the strings of solar panels may be sensed and provided to a computer that generates current-voltage (IV) curves of the strings of solar panels. Output voltages of the string of solar panels may be sensed at the string or at the device presenting the DC load. The DC load may be varied. Output currents of the strings of solar panels responsive to the variation of the DC load are sensed to generate IV curves of the strings of solar panels. IV curves may be compared and analyzed to evaluate performance of and detect problems with a string of solar panels.

14 SOLAR ENERGY↗

Comparison of loads from HAWC2 and OpenFAST for the IEA Wind 15 MW Reference Wind Turbine

Reference wind turbines (RWTs) that reflect the state-of-the-art of current wind energy technology are necessary in order to properly evaluate innovative methods in wind turbine design and evaluation. The International Energy Agency (IEA) Wind Technology Collaboration Platform (TCP) Task 37 has recently developed a new RWT geared towards offshore floating-foundation applications: the IEA Wind 15 MW. The model has been implemented in two aeroelastic codes, OpenFAST and HAWC2, based on an underlying common ontology. However, these toolchains result in slightly different structural parameters, and the two codes utilise different structural models. Thus, to increase the utility of the model, it is necessary to compare the aeroelastic responses. This paper compares aeroelastic loads calculated using different fidelities of the blade model in OpenFAST (ElastoDyn and BeamDyn) and HAWC2 (prismatic Timoshenko without torsion and Timoshenko with fully populated stiffness matrix), where both codes use the DTU Basic controller and the same turbulence boxes to reduce discrepancies. The aeroelastic responses to steady wind, step wind and turbulent wind (per IEC 61400-1 wind class IB) are considered. The results indicate a generally good agreement between the loads dominated by aerodynamic thrust and force, especially for the no-torsion blade models. Discrepancies were observed in other load channels, partially due to differences in the asymmetric loading of the rotor and partially due to differing closed-loop dynamics, and they will be the subject of future investigations.

17 WIND ENERGY↗

MPC solution for optimal load shifting for buildings with ON/OFF staged packaged units: Experimental demonstration, and lessons learned

Small and medium-sized commercial buildings (SMCB) are significant demand response resources, and it is important to develop grid-responsive control algorithms that exploit those resources and create financial benefits for building owners and HVAC service providers. Furthermore, unlike large-sized commercial buildings, there is an opportunity to have universally applicable control solutions for many SMCBs since those buildings have a consistent HVAC system configuration: SMCBs are commonly served by multiple-staged air conditioning units controlled by their own thermostats. Despite the demand response potential and scalability, however, very few control solutions are available for SMCBs. Typical model predictive control (MPC) and heuristic control approaches for cooling load shifting that lower thermostat setpoints before an electric price jump are suitable mainly for large-sized commercial buildings where a continuous capacity modulation is possible, e.g., via dampers in variable air volume terminal units. However, those approaches can cause undesired, high peaks for SMCBs due to the nature of ON/OFF unit staging and narrow thermostat deadbands. This could discourage the use of advanced grid-responsive controls for SMCBs due to the concern of high demand charges, and has to be resolved. This paper presents a MPC solution that overcomes this challenge. It has a hierarchical MPC structure where an upper level MPC is responsible for electrical load shifting in response to an electric price signal while a lower level MPC is responsible for coordinating compressor stages to eliminate unnecessary peaks and follows the setpoints determined by the upper level MPC. In this work, two one-month, comprehensive laboratory tests have been carried out to demonstrate load shifting and cost savings for the algorithm. Interesting trade-offs between energy efficiency and load flexibility were observed and are discussed, and lessons learned for applying MPCs for SMCBs are also presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multiscale Failure Analysis of a 3D Woven Unit Cell Containing Defects

Multiscale failure simulations have been performed for a Three-dimensional woven composite unit cell considering five, or more, length scales spanning the woven composite mesoscale to the sub-microscale voids. The multiscale recursive micromechanics approach, which enables recursive integration of general micromechanics theories over an arbitrary number of length scales, has been employed within the NASA Multiscale Analysis Tool. The multiscale model uses both the generalized method of cells and Mori-Tanaka micromechanics theories, and considers failure in the constituent materials using a simple damage model. Baseline results, containing distributed voids, are compared to uniaxial experimental data for an AS4 carbon fiber/ RTM6 epoxy matrix 3D orthogonal woven composite with good agreement in terms of global stiffness and global failure stress. The simulations demonstrate that the 3D woven composite exhibits damage tolerance through sustaining increasing axial load far beyond the first initiation of damage. The multiscale model is used to examine the nonlinear response of the material to other loading conditions. Case studies, motivated by X-ray computed tomography data, are presented on the effects of manufacturing induced voids and cracks.

3D woven↗

Combined mechanical loading of composite tubes

An analytical/experimental investigation was performed to study the effect of material nonlinearities on the response of composite tubes subjected to combined axial and torsional loading. The effect of residual stresses on subsequent mechanical response was included in the investigation. Experiments were performed on P75/934 graphite-epoxy tubes with a stacking sequence of (15/0/ + or - 10/0/ -15), using pure torsion and combined axial/torsional loading. In the presence of residual stresses, the analytical model predicted a reduction in the initial shear modulus. Experimentally, coupling between axial loading and shear strain was observed in laminated tubes under combined loading. The phenomenon was predicted by the nonlinear analytical model. The experimentally observed linear limit of the global shear response was found to correspond to the analytically predicted first ply failure. Further, the failure of the tubes was found to be path dependent above a critical load level.

Derstine, Mark S.↗

Response of discretely stiffened structures

This paper presents a theoretical study on dynamic response of complex discretely stiffened and interconnected structures to random loads. Modal and transfer matrix techniques are utilized to analyze these multidimensional structures. Application of this formulation for response and noise generation studies in space station and fuselage-wing design is discussed. The response spectral densities are calculated for several typical discretely stiffened and interconnected structural systems. It is found that this approach allows for easy parametric evaluation and that by proper selection of structural parameters and loading conditions, the vibration response can be reduced.

Vaicaitis, R.↗

Recovery Act: Advanced Load Identification and Management for Buildings

In response to the U.S. Department of Energy (DoE)’s goal of achieving market ready, net-zero energy residential and commercial buildings by 2020 and 2025, Eaton partnered with the Department of Energy’s National Renewable Energy Laboratory (NREL) and Georgia Institute of Technology to develop an intelligent load identification and management technology enabled by a novel “smart power strip” to provide critical intelligence and information to improve the capability and functionality of building load analysis and building power management systems. Buildings account for 41% of the energy consumption in the United States, significantly more than either transportation or industrial. Within the building sector, plug loads account for a significant portion of energy consumption. Plug load consumes 15-20% of building energy on average. As building managers implement aggressive energy conservation measures, the proportion of plug load energy can increase to as much as 50% of building energy leaving plug loads as the largest remaining single source of energy consumption. This project focused on addressing plug-in load control and management to further improve building energy efficiency accomplished through effective load identification. The execution of the project falls into the following three major aspects; An intelligent load modeling, identification and prediction technology was developed to automatically determine the type, energy consumption, power quality, operation status and performance status of plug-in loads, using electric waveforms at a power outlet level. This project demonstrated the effectiveness of the developed technology through a large set of plug-in loads measurements and testing; A novel “Smart Power Strip (SPS) / Receptacle” prototype was developed to act as a vehicle to demonstrate the feasibility of load identification technology as a low-cost, embedded solution; and Market environment for plug-in load control and management solutions, in particular, advanced power strips (APSs) was studied. The project evaluated the market potential for Smart Power Strips (SPSs) with load identification and the likely impact of a load identification feature on APS adoption and effectiveness. The project also identified other success factors required for widespread APS adoption and market acceptance. Even though the developed technology is applicable for both residential and commercial buildings, this project is focused on effective plug-in load control and management for commercial buildings, accomplished through effective load identification. The project has completed Smart Receptacle (SR) prototype development with integration of Load ID, Control/Management, WiFi communication, and Web Service. Twenty SR units were built, tested, and demonstrated in the Eaton lab; eight SR units were tested in the National Renewable Energy Lab (NREL) for one-month of field testing. Load ID algorithm testing for extended load sets was conducted within the Eaton facility and at local university campuses. This report is to summarize the major achievements, activities, and outcomes under the execution of the project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Efficiency Analysis and Grid Service Results for Commercial Buildings using the VOLTRON IoT Platform

In fiscal year 2021 (FY21), the Commercial Buildings Integration Program (CBI) within the Building Technologies Office (BTO), funded PNNL to conduct a field evaluation of the AIRCx and ILC using an Internet-of-Things (IoT) platform, VOLTTRON. The primary goal of the project is to show that software solutions deployed and delivered through an IoT-platform can identify energy efficiency opportunities and manage peak load (beyond the traditional demand response) in commercial buildings. There are also two secondary goals: 1) show that the energy efficiency solutions will result in identification of significant savings opportunities (10% to 30%) as well as energy cost reductions (10% to 15%) by managing the peak load in commercial buildings, and 2) show that an IoT-based software solution is more cost-effective compared to a manual process in meeting the Re-tuning/retro commissioning (RCx) mandates and there is a pathway for broader adoption of this approach. This report provides AIRCx and ILC results for two building located in District of Columbia managed by the energy service provider Intellimation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗