Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Vorticity-induced flow-focusing leads to bubble entrainment in an inkjet printhead: Synchrotron x-ray and volume-of-fluid visualizations

The oscillatory flows present in an inkjet printhead can lead to strong deformations of the air-liquid interface at the nozzle exit. Such deformations may lead to an inward directed air jet with bubble pinch-off and the subsequent entrainment of an air bubble, which is highly detrimental to the stability of inkjet printing. Understanding the mechanisms of bubble entrainment is therefore crucial to improving print stability. Here, in the present work, we use ultrafast x-ray phase-contrast imaging and direct numerical simulations based on the volume-of-fluid method to study the mechanisms underlying the bubble entrainment in a piezoacoustic printhead. We first demonstrate good agreement between experiments and numerics. We then show the different classes of bubble pinch-off obtained in experiments, and that those were also captured numerically. The numerical results are then used to show that the baroclinic torque, which is generated at the gas-liquid interface due to the misalignment of density and pressure gradients, results in a flow-focusing effect that drives the formation of the air jet from which a bubble can pinch off.

42 ENGINEERING↗

Near, far, wherever you are: simulations on the dose efficiency of holographic and ptychographic coherent imaging

Different studies in X-ray microscopy have arrived at conflicting conclusions about the dose efficiency of imaging modes involving the recording of intensity distributions in the near (Fresnel regime) or far (Fraunhofer regime) field downstream of a specimen. A numerical study is presented on the dose efficiency of near-field holography, near-field ptychography and far-field ptychography, where ptychography involves multiple overlapping finite-sized illumination positions. Unlike what has been reported for coherent diffraction imaging, which involves recording a single far-field diffraction pattern, it is found that all three methods offer similar image quality when using the same fluence on the specimen, with far-field ptychography offering slightly better spatial resolution and a lower mean error. These results support the concept that (if the experiment and image reconstruction are done properly) the sample can be near or far; wherever you are, photon fluence on the specimen sets one limit to spatial resolution.

42 ENGINEERING↗

Synthesizing pseudo-Kossel lines from neutron transmission data. I. An analytical approach for recovering single-crystal orientation

The energy-dispersive neutron spectra transmitted through single crystals are characterized by sharp Bragg dips at specific wavelengths, where Bragg's law is being fulfilled for certain crystallographic planes. This phenomenon allows for developing methods for crystal-orientation determination techniques similar to electron backscatter diffraction and X-ray diffraction microscopy. This work presents a new procedure to recover the orientation matrix for single crystals using transmission spectra recorded during rotation of a crystal about an axis perpendicular to a polychromatic neutron beam. The proposed method consists of an initial transformation of the as-collected wavelength–rotation maps to a wavevector $\textit{K}$ space, resulting in linear pseudo-Kossel lines that are suitable for analysis and indexing using image-processing procedures. Further, simulated neutron transmission spectra through a copper crystal with known orientations were used to set and prove the numerical approach. This technique may be expanded for cases where the neutron beam intersects multiple single-crystal grains with different orientations.

36 MATERIALS SCIENCE↗

Towards Interactive, Reproducible Analytics at Scale on HPC Systems

The growth in scientific data volumes has resulted in a need to scale up processing and analysis pipelines using High Performance Computing (HPC) systems. These workflows need interactive, reproducible analytics at scale. The Jupyter platform provides core capabilities for interactivity but was not designed for HPC systems. In this paper, we outline our efforts that bring together core technologies based on the Jupyter Platform to create interactive, reproducible analytics at scale on HPC systems. Our work is grounded in a real world science use case-applying geophysical simulations and inversions for imaging the subsurface. Our core platform addresses three key areas of the scientific analysis workflow-reproducibility, scalability, and interactivity. We describe our implemention of a system, using Binder, Science Capsule, and Dask software. We demonstrate the use of this software to run our use case and interactively visualize real-Time streams of HDF5 data.

containers↗

An engineered design of a diffractive mask for high precision astrometry [Modeling a diffractive mask that calibrates optical distortions]

AutoCAD, Zemax Optic Studio 15, and Interactive Data Language (IDL) with the Proper Library are used to computationally model and test a diffractive mask (DiM) suitable for use in the Gemini Multi-Conjugate Adaptive Optics System (GeMS) on the Gemini South Telescope. Systematic errors in telescope imagery are produced when the light travels through the adaptive optics system of the telescope. DiM is a transparent, flat optic with a pattern of miniscule dots lithographically applied to it. It is added ahead of the adaptive optics system in the telescope in order to produce diffraction spots that will encode systematic errors in the optics after it. Once these errors are encoded, they can be corrected for. DiM will allow for more accurate measurements in astrometry and thus improve exoplanet detection. Furthermore, the mechanics and physical attributes of the DiM are modeled in AutoCAD. Zemax models the ray propagation of point sources of light through the telescope. IDL and Proper simulate the wavefront and image results of the telescope. Aberrations are added to the Zemax and IDL models to test how the diffraction spots from the DiM change in the final images. Based on the Zemax and IDL results, the diffraction spots are able to encode the systematic aberrations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TU-F-17A-03: An Analytical Respiratory Perturbation Model for Lung Motion Prediction

Purpose: Breathing irregularity is common, causing unreliable prediction in tumor motion for correlation-based surrogates. Both tidal volume (TV) and breathing pattern (BP=ΔVthorax/TV, where TV=ΔVthorax+ΔVabdomen) affect lung motion in anterior-posterior and superior-inferior directions. We developed a novel respiratory motion perturbation (RMP) model in analytical form to account for changes in TV and BP in motion prediction from simulation to treatment. Methods: The RMP model is an analytical function of patient-specific anatomic and physiologic parameters. It contains a base-motion trajectory d(x,y,z) derived from a 4-dimensional computed tomography (4DCT) at simulation and a perturbation term Δd(ΔTV,ΔBP) accounting for deviation at treatment from simulation. The perturbation is dependent on tumor-specific location and patient-specific anatomy. Eleven patients with simulation and treatment 4DCT images were used to assess the RMP method in motion prediction from 4DCT1 to 4DCT2, and vice versa. For each patient, ten motion trajectories of corresponding points in the lower lobes were measured in both 4DCTs: one served as the base-motion trajectory and the other as the ground truth for comparison. In total, 220 motion trajectory predictions were assessed. The motion discrepancy between two 4DCTs for each patient served as a control. An established 5D motion model was used for comparison. Results: The average absolute error of RMP model prediction in superior-inferior direction is 1.6±1.8 mm, similar to 1.7±1.6 mm from the 5D model (p=0.98). Some uncertainty is associated with limited spatial resolution (2.5mm slice thickness) and temporal resolution (10-phases). Non-corrected motion discrepancy between two 4DCTs is 2.6±2.7mm, with the maximum of ±20mm, and correction is necessary (p=0.01). Conclusion: The analytical motion model predicts lung motion with accuracy similar to the 5D model. The analytical model is based on physical relationships, requires no training, and therefore is potentially more resilient to breathing irregularities. On-going investigation introduces airflow into the RMP model for improvement. This research is in part supported by NIH (U54CA137788/132378). AY would like to thank MSKCC summer medical student research program supported by National Cancer Institute and hosted by Department of Medical Physics at MSKCC.

60 APPLIED LIFE SCIENCES↗

Feasibility of RACT for 3D dose measurement and range verification in a water phantom

Purpose: The objective of this study is to establish the feasibility of using radiation-induced acoustics to measure the range and Bragg peak dose from a pulsed proton beam. Simulation studies implementing a prototype scanner design based on computed tomographic methods were performed to investigate the sensitivity to proton range and integral dose. Methods: Derived from thermodynamic wave equation, the pressure signals generated from the dose deposited from a pulsed proton beam with a 1 cm lateral beam width and a range of 16, 20, and 27 cm in water using Monte Carlo methods were simulated. The resulting dosimetric images were reconstructed implementing a 3D filtered backprojection algorithm and the pressure signals acquired from a 71-transducer array with a cylindrical geometry (30 × 40 cm) rotated over 2π about its central axis. Dependencies on the detector bandwidth and proton beam pulse width were performed, after which, different noise levels were added to the detector signals (using 1 μs pulse width and a 0.5 MHz cutoff frequency/hydrophone) to investigate the statistical and systematic errors in the proton range (at 20 cm) and Bragg peak dose (of 1 cGy). Results: The reconstructed radioacoustic computed tomographic image intensity was shown to be linearly correlated to the dose within the Bragg peak. And, based on noise dependent studies, a detector sensitivity of 38 mPa was necessary to determine the proton range to within 1.0 mm (full-width at half-maximum) (systematic error < 150 μm) for a 1 cGy Bragg peak dose, where the integral dose within the Bragg peak was measured to within 2%. For existing hydrophone detector sensitivities, a Bragg peak dose of 1.6 cGy is possible. Conclusions: This study demonstrates that computed tomographic scanner based on ionizing radiation-induced acoustics can be used to verify dose distribution and proton range with centi-Gray sensitivity. Realizing this technology into the clinic has the potential to significantly impact beam commissioning, treatment verification during particle beam therapy and image guided techniques.

07 ISOTOPE AND RADIATION SOURCES↗

MO-D-BRB-00: Pediatric Radiation Therapy Planning, Treatment, and Late Effects

Most Medical Physicists working in radiotherapy departments see few pediatric patients. This is because, fortunately, children get cancer at a rate nearly 100 times lower than adults. Children have not smoked, abused alcohol, or been exposed to environmental carcinogens for decades, and of course, have not fallen victim to the aging process. Children get very different cancers than adults. Breast or prostate cancers, typical in adults, are rarely seen in children but instead a variety of tumors occur in children that are rarely seen in adults; examples are germinomas, ependymomas and primitive neuroectodermal tumors, which require treatment of the child’s brain or neuroblastoma, requiring treatment in the abdomen. The treatment of children with cancer using radiation therapy is one of the most challenging planning and delivery problems facing the physicist. This is because bones, brain, breast tissue, and other organs are more sensitive to radiation in children than in adults. Because most therapy departments treat mostly adults, when the rare 8 year-old patient comes to the department for treatment, the physicist may not understand the clinical issues of his disease which drive the planning and delivery decisions. Additionally, children are more prone than adults to developing secondary cancers after radiation. For bilateral retinoblastoma for example, an irradiated child has a 40% chance of developing a second cancer by age 50. The dosimetric tradeoffs made during the planning process are complex and require careful consideration for children treated with radiotherapy. In the first presentation, an overview of childhood cancers and their corresponding treatment techniques will be given. These can be some of the most complex treatments that are delivered in the radiation therapy department. These cancers include leukemia treated with total body irradiation, medulloblastoma, treated with craniospinal irradiation plus a conformal boost to the posterior fossa, neuroblastoma, requiring focal abdominal irradiation to avoid kidney, liver, and vertebral body damage, retinoblastoma, requiring treatment to an eye while minimizing dose to surrounding tissues, and a variety of other tumors which occur anywhere in the body. Case studies will be presented showing the treatment technique and resulting dosimetry, highlighting the objectives for tumor coverage and organ-at-risk sparing. Practical issues that have to be faced when treating children will also be discussed such as daily sedation and immobilization. Late effects based on the current understanding of dose-volume response in normal tissues will be discussed. In the second presentation, specific focus will be on pediatric proton therapy. We will review literature publications on dosimetric comparison of proton versus photon plans, common pediatric tumors treated with protons, and available clinical outcomes. We will describe simulation technique, treatment planning, image guidance for setup verification, and proton beam delivery unique to pediatric and adolescent patients. Finally, we will discuss desired improvements, outlook, and opportunities for medical physicists in pediatric proton therapy. Learning Objectives: Improve understanding about childhood cancer and treatment with radiation Understand treatment planning and delivery issues and associated late effects specific to children Become aware of specific treatment methods for the most challenging pediatric cancers Know the current status, techniques, and desired improvements for pediatric proton therapy.

60 APPLIED LIFE SCIENCES↗

MO-D-BRB-01: Pediatric Treatment Planning I: Overview of Planning Strategies and Challenges

Most Medical Physicists working in radiotherapy departments see few pediatric patients. This is because, fortunately, children get cancer at a rate nearly 100 times lower than adults. Children have not smoked, abused alcohol, or been exposed to environmental carcinogens for decades, and of course, have not fallen victim to the aging process. Children get very different cancers than adults. Breast or prostate cancers, typical in adults, are rarely seen in children but instead a variety of tumors occur in children that are rarely seen in adults; examples are germinomas, ependymomas and primitive neuroectodermal tumors, which require treatment of the child’s brain or neuroblastoma, requiring treatment in the abdomen. The treatment of children with cancer using radiation therapy is one of the most challenging planning and delivery problems facing the physicist. This is because bones, brain, breast tissue, and other organs are more sensitive to radiation in children than in adults. Because most therapy departments treat mostly adults, when the rare 8 year-old patient comes to the department for treatment, the physicist may not understand the clinical issues of his disease which drive the planning and delivery decisions. Additionally, children are more prone than adults to developing secondary cancers after radiation. For bilateral retinoblastoma for example, an irradiated child has a 40% chance of developing a second cancer by age 50. The dosimetric tradeoffs made during the planning process are complex and require careful consideration for children treated with radiotherapy. In the first presentation, an overview of childhood cancers and their corresponding treatment techniques will be given. These can be some of the most complex treatments that are delivered in the radiation therapy department. These cancers include leukemia treated with total body irradiation, medulloblastoma, treated with craniospinal irradiation plus a conformal boost to the posterior fossa, neuroblastoma, requiring focal abdominal irradiation to avoid kidney, liver, and vertebral body damage, retinoblastoma, requiring treatment to an eye while minimizing dose to surrounding tissues, and a variety of other tumors which occur anywhere in the body. Case studies will be presented showing the treatment technique and resulting dosimetry, highlighting the objectives for tumor coverage and organ-at-risk sparing. Practical issues that have to be faced when treating children will also be discussed such as daily sedation and immobilization. Late effects based on the current understanding of dose-volume response in normal tissues will be discussed. In the second presentation, specific focus will be on pediatric proton therapy. We will review literature publications on dosimetric comparison of proton versus photon plans, common pediatric tumors treated with protons, and available clinical outcomes. We will describe simulation technique, treatment planning, image guidance for setup verification, and proton beam delivery unique to pediatric and adolescent patients. Finally, we will discuss desired improvements, outlook, and opportunities for medical physicists in pediatric proton therapy. Learning Objectives: Improve understanding about childhood cancer and treatment with radiation Understand treatment planning and delivery issues and associated late effects specific to children Become aware of specific treatment methods for the most challenging pediatric cancers Know the current status, techniques, and desired improvements for pediatric proton therapy.

60 APPLIED LIFE SCIENCES↗

MO-D-BRB-02: Pediatric Treatment Planning II: Applications of Proton Beams for Pediatric Treatment

Most Medical Physicists working in radiotherapy departments see few pediatric patients. This is because, fortunately, children get cancer at a rate nearly 100 times lower than adults. Children have not smoked, abused alcohol, or been exposed to environmental carcinogens for decades, and of course, have not fallen victim to the aging process. Children get very different cancers than adults. Breast or prostate cancers, typical in adults, are rarely seen in children but instead a variety of tumors occur in children that are rarely seen in adults; examples are germinomas, ependymomas and primitive neuroectodermal tumors, which require treatment of the child’s brain or neuroblastoma, requiring treatment in the abdomen. The treatment of children with cancer using radiation therapy is one of the most challenging planning and delivery problems facing the physicist. This is because bones, brain, breast tissue, and other organs are more sensitive to radiation in children than in adults. Because most therapy departments treat mostly adults, when the rare 8 year-old patient comes to the department for treatment, the physicist may not understand the clinical issues of his disease which drive the planning and delivery decisions. Additionally, children are more prone than adults to developing secondary cancers after radiation. For bilateral retinoblastoma for example, an irradiated child has a 40% chance of developing a second cancer by age 50. The dosimetric tradeoffs made during the planning process are complex and require careful consideration for children treated with radiotherapy. In the first presentation, an overview of childhood cancers and their corresponding treatment techniques will be given. These can be some of the most complex treatments that are delivered in the radiation therapy department. These cancers include leukemia treated with total body irradiation, medulloblastoma, treated with craniospinal irradiation plus a conformal boost to the posterior fossa, neuroblastoma, requiring focal abdominal irradiation to avoid kidney, liver, and vertebral body damage, retinoblastoma, requiring treatment to an eye while minimizing dose to surrounding tissues, and a variety of other tumors which occur anywhere in the body. Case studies will be presented showing the treatment technique and resulting dosimetry, highlighting the objectives for tumor coverage and organ-at-risk sparing. Practical issues that have to be faced when treating children will also be discussed such as daily sedation and immobilization. Late effects based on the current understanding of dose-volume response in normal tissues will be discussed. In the second presentation, specific focus will be on pediatric proton therapy. We will review literature publications on dosimetric comparison of proton versus photon plans, common pediatric tumors treated with protons, and available clinical outcomes. We will describe simulation technique, treatment planning, image guidance for setup verification, and proton beam delivery unique to pediatric and adolescent patients. Finally, we will discuss desired improvements, outlook, and opportunities for medical physicists in pediatric proton therapy. Learning Objectives: Improve understanding about childhood cancer and treatment with radiation Understand treatment planning and delivery issues and associated late effects specific to children Become aware of specific treatment methods for the most challenging pediatric cancers Know the current status, techniques, and desired improvements for pediatric proton therapy.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-JeP1-01: Prompt Gamma Imaging with a Multi-Knife-Edge Slit Collimator: Evaluation for Use in Proton Beam Range Verification

Purpose: To evaluate and characterize a multi-slit collimated imaging system for use in prompt gamma range verification of proton therapy. Methods: Acrylic (PMMA) targets were irradiated with a 50 MeV proton beam. With the collimator placed 13 cm from the beam axis, photons of energy from 2–7 MeV were measured. Image reconstruction provided 2-dimensional distribution of gamma rays. Estimated Bragg peak location was compared with 1-dimensional profiles of photon images. Shifts in Bragg peak were simulated by physically moving the targets in 1 mm increments. Results: The imaging system measured prompt gamma emissions resulting from a 50 MeV proton beam, at currents up to 2 nA, incident on a PMMA target. Overall system detection efficiency was approximately 2.6×10{sup −5} gamma/proton. With delivery of 1×10{sup 11} protons, shifts of 1 mm in the target location were detected in 2D prompt gamma images and 1D profiles. With delivery of 1×10{sup 8} protons, shifts of approximately 3 mm were detectable. Conclusion: This work has characterized the performance of a prototype multi-slit collimated imaging system. The system can produce 2D images of prompt gamma distributions and detect shifts in Bragg peak location down to 1 mm. These results encourage further development and optimization of the system for clinical proton beam applications. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number: DENA0000979 through the Nuclear Science and Security Consortium.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRC-10: Modeling of Radiotherapy Linac Source Terms Using ARCHER Monte Carlo Code: Performance Comparison of GPU and MIC Computing Accelerators

Purpose: (1) To perform phase space (PS) based source modeling for Tomotherapy and Varian TrueBeam 6 MV Linacs, (2) to examine the accuracy and performance of the ARCHER Monte Carlo code on a heterogeneous computing platform with Many Integrated Core coprocessors (MIC, aka Xeon Phi) and GPUs, and (3) to explore the software micro-optimization methods. Methods: The patient-specific source of Tomotherapy and Varian TrueBeam Linacs was modeled using the PS approach. For the helical Tomotherapy case, the PS data were calculated in our previous study (Su et al. 2014 41(7) Medical Physics). For the single-view Varian TrueBeam case, we analytically derived them from the raw patient-independent PS data in IAEA’s database, partial geometry information of the jaw and MLC as well as the fluence map. The phantom was generated from DICOM images. The Monte Carlo simulation was performed by ARCHER-MIC and GPU codes, which were benchmarked against a modified parallel DPM code. Software micro-optimization was systematically conducted, and was focused on SIMD vectorization of tight for-loops and data prefetch, with the ultimate goal of increasing 512-bit register utilization and reducing memory access latency. Results: Dose calculation was performed for two clinical cases, a Tomotherapy-based prostate cancer treatment and a TrueBeam-based left breast treatment. ARCHER was verified against the DPM code. The statistical uncertainty of the dose to the PTV was less than 1%. Using double-precision, the total wall time of the multithreaded CPU code on a X5650 CPU was 339 seconds for the Tomotherapy case and 131 seconds for the TrueBeam, while on 3 5110P MICs it was reduced to 79 and 59 seconds, respectively. The single-precision GPU code on a K40 GPU took 45 seconds for the Tomotherapy dose calculation. Conclusion: We have extended ARCHER, the MIC and GPU-based Monte Carlo dose engine to Tomotherapy and Truebeam dose calculations.

60 APPLIED LIFE SCIENCES↗

Computational Examination of Orientation-Dependent Morphological Evolution during the Electrodeposition and Electrodissolution of Magnesium

Here a new model of electrodeposition and electrodissolution is developed and applied to the evolution of Mg deposits during anode cycling. The model captures Butler-Volmer kinetics, facet evolution, the spatially varying potential in the electrolyte, and the time-dependent electrolyte concentration. The model utilizes a diffuse interface approach, employing the phase field and smoothed boundary methods. Scanning electron microscope (SEM) images of magnesium deposited on a gold substrate show the formation of faceted deposits, often in the form of hexagonal prisms. Orientation-dependent reaction rate coefficients were parameterized using the experimental SEM images. Three-dimensional simulations of the growth of magnesium deposits yield deposit morphologies consistent with the experimental results. The simulations predict that the deposits become narrower and taller as the current density increases due to the depletion of the electrolyte concentration near the sides of the deposits. Increasing the distance between the deposits leads to increased depletion of the electrolyte surrounding the deposit. Two models relating the orientation-dependence of the deposition and dissolution reactions are presented. Finally, the morphology of the Mg deposit after one deposition-dissolution cycle is significantly different between the two orientation-dependence models, providing testable predictions that suggest the underlying physical mechanisms governing morphology evolution during deposition and dissolution.

36 MATERIALS SCIENCE↗

Invited Review. Combustion instability in spray-guided stratified-charge engines. A review

Our article reviews systematic research on combustion instabilities (principally rare, random misfires and partial burns) in spray-guided stratified-charge (SGSC) engines operated at part load with highly stratified fuel -air -residual mixtures. Results from high-speed optical imaging diagnostics and numerical simulation provide a conceptual framework and quantify the sensitivity of ignition and flame propagation to strong, cyclically varying temporal and spatial gradients in the flow field and in the fuel -air -residual distribution. For SGSC engines using multi-hole injectors, spark stretching and locally rich ignition are beneficial. Moreover, combustion instability is dominated by convective flow fluctuations that impede motion of the spark or flame kernel toward the bulk of the fuel, coupled with low flame speeds due to locally lean mixtures surrounding the kernel. In SGSC engines using outwardly opening piezo-electric injectors, ignition and early flame growth are strongly influenced by the spray's characteristic recirculation vortex. For both injection systems, the spray and the intake/compression-generated flow field influence each other. Factors underlying the benefits of multi-pulse injection are identified. Finally, some unresolved questions include (1) the extent to which piezo-SGSC misfires are caused by failure to form a flame kernel rather than by flame-kernel extinction (as in multi-hole SGSC engines); (2) the relative contributions of partially premixed flame propagation and mixing-controlled combustion under the exceptionally late-injection conditions that permit SGSC operation on E85-like fuels with very low NO x and soot emissions; and (3) the effects of flow-field variability on later combustion, where fuel-air-residual mixing within the piston bowl becomes important.

42 ENGINEERING↗

Turbine Aeration Design Software for Mitigating Adverse Environmental Impacts Resulting From Conventional Hydropower Turbines

Conventional hydropower turbine aeration test-bed for computational routines and software tools for improving environmental mitigation technologies for conventional hydropower systems. In achieving this goal, we have partnered with Alstom, a global leader in energy technology development and United States power generation, with additional funding from the Initiative for Renewable Energy and the Environment (IREE) and the College of Science and Engineering (CSE) at the UMN

13 HYDRO ENERGY↗

Simulation Based Inference with Domain Adaptation for Strong Gravitational Lensing

Simulation based inference leverages machine learning to carry out Bayesian inference for systems with intractable likelihoods. However, transitioning a network trained on simulated data to real data runs the risk of encountering domain shift, leading to performance losses. We attempt to implement domain adaptation into the sbi neural posterior estimation framework using the Maximum Mean Discrepancy as an additional network loss. We test two network architectures and use masked autoregressive flow for density estimation. We test the network on a set of 400,000 simulated strong gravitational lensing images generated using deeplenstronomy. The source domain is defined as low noise whereas the target domain has a noise profile sampled from experimentally derived DES survey conditions. We find that, while DA does lead to performance improvements, they are marginal at ~6% less inference error. We also find a similar marginal improvement in uncertainty calibration at around 8%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward Complete Merger Identification at Cosmic Noon with Deep Learning

As we enter the era of large imaging surveys such as Roman, Rubin, and Euclid, a deeper understanding of potential biases and selection effects in optical astronomical catalogs created with the use of ML-based methods is paramount. This work focuses on a deeper understanding of the performance and limitations of deep learning-based classifiers as tools for galaxy merger identification. We train a ConvNeXT-Pico model on mock HST CANDELS images from the IllustrisTNG50 simulation. Our focus is on a more challenging classification of galaxy mergers and non-mergers at higher redshifts 1 < z < 1.5, including minor mergers and lower mass galaxies down to the stellar mass of 108M⊙. We demonstrate, for the first time, that a deep learning model, such as the one developed in this work, can successfully identify even minor and low mass mergers even at these redshifts. Our model achieves overall accuracy, purity, and completeness of over 73%. We show that some galaxy mergers can only be identified from certain observation angles, leading to a potential upper limit in overall accuracy. Using Grad-CAMs and UMAPs, we more deeply examine the performance and observe a visible gradient in the latent space with stellar mass and specific star formation rate, but no visible gradient with merger mass ratio or merger stage.

Schechter, Aimee L. [U. Colorado, Boulder]↗

Bridging Time-series Image Phenotyping and Functional–Structural Plant Modeling to Predict Adventitious Root System Architecture

Root system architecture (RSA) is an important measure of how plants navigate and interact with the soil environment. However, current methods in studying RSA must make tradeoffs between precision of data and proximity to natural conditions, with root growth in germination papers providing accessibility and high data resolution. Functional–structural plant models (FSPMs) can overcome this tradeoff, though parameterization and evaluation of FSPMs are traditionally based in manual measurements and visual comparison. Here, we applied a germination paper system to study the adventitious RSA and root phenology of Populus trichocarpa stem cuttings using time-series image-based phenotyping augmented by FSPM. We found a significant correlation between timing of root initiation and thermal time at cutting collection (P value = 0.0061, R 2 = 0.875), but little correlation with RSA. We also present a use of RhizoVision [1] for automatically extracting FSPM parameters from time series images and evaluating FSPM simulations. A high accuracy of the parameterization was achieved in predicting 2D growth with a sensitivity rate of 83.5%. This accuracy was lost when predicting 3D growth with sensitivity rates of 38.5% to 48.7%, while overall accuracy varied with phenotyping methods. Despite this loss in accuracy, the new method is amenable to high throughput FSPM parameterization and bridges the gap between advances in time-series phenotyping and FSPMs.

60 APPLIED LIFE SCIENCES↗