Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “home performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Hi-Q Rotor - Low Wind Speed Technology

The project objective was to optimize the performance of the Hi-Q Rotor. Early research funded by the California Energy Commission indicated the design might be advantageous over state-of-the-art turbines for collecting wind energy in low wind conditions. The Hi-Q Rotor is a new kind of rotor targeted for harvesting wind in Class 2, 3, and 4 sites, and has application in areas that are closer to cities, or 'load centers.' An advantage of the Hi-Q Rotor is that the rotor has non-conventional blade tips, producing less turbulence, and is quieter than standard wind turbine blades which is critical to the low-wind populated urban sites. Unlike state-of-the-art propeller type blades, the Hi-Q Rotor has six blades connected by end caps. In this phase of the research funded by DOE's Inventions and Innovation Program, the goal was to improve the current design by building a series of theoretical and numeric models, and composite prototypes to determine a best of class device. Development of the rotor was performed by aeronautical engineering and design firm, DARcorporation. From this investigation, an optimized design was determined and an 8-foot diameter, full-scale rotor was built and mounted using a Bergey LX-1 generator and furling system which were adapted to support the rotor. The Hi-Q Rotor was then tested side-by-side against the state-of-the-art Bergey XL-1 at the Alternative Energy Institute's Wind Test Center at West Texas State University for six weeks, and real time measurements of power generated were collected and compared. Early wind tunnel testing showed that the cut-in-speed of the Hi-Q rotor is much lower than a conventional tested HAWT enabling the Hi-Q Wind Turbine to begin collecting energy before a conventional HAWT has started spinning. Also, torque at low wind speeds for the Hi-Q Wind Turbine is higher than the tested conventional HAWT and enabled the wind turbine to generate power at lower wind speeds. Based on the data collected, the results of our first full-scale prototype wind turbine proved that higher energy can be captured at lower wind speeds with the new Hi-Q Rotor. The Hi-Q Rotor is almost 15% more productive than the Bergey from 6 m/s to 8 m/s, making it ideal in Class 3, 4, and 5 wind sites and has application in the critical and heretofore untapped areas that are closer to cities, 'load centers,' and may even be used directly in urban areas. The additional advantage of the Hi-Q Rotor's non-conventional blade tips, which eliminates most air turbulence, is noise reduction which makes it doubly ideal for populated urban areas. Hi-Q Products recommends one final stage of development to take the Hi-Q Rotor through Technology Readiness Levels 8-9. During this stage of development, the rotor will be redesigned to further increase efficiency, match the rotor to a more suitable generator, and lower the cost of manufacturing by redesigning the structure to allow for production in larger quantities at lower cost. Before taking the rotor to market and commercialization, it is necessary to further optimize the performance by finding a better generator and autofurling system, ones more suitable for lower wind speeds and rpms should be used in all future testing. The potential impact of this fully developed technology will be the expansion and proliferation of energy renewal into the heretofore untapped Class 2, 3, 4, and 5 Wind Sites, or the large underutilized sites where the wind speed is broken by physical features such as mountains, buildings, and trees. Market estimates by 2011, if low wind speed technology can be developed are well above: 13 million homes, 675,000 commercial buildings, 250,000 public facilities. Estimated commercial exploitation of the Hi-Q Rotor show potential increase in U.S. energy gained through the clean, renewable wind energy found in low and very low wind speed sites. This new energy source would greatly impact greenhouse emissions as well as the public sector's growing energy demands.

17 WIND ENERGY↗

Central Park Ecological Conservation: Assessing Tree Health Conditions in New York City’s Central Park with NASA Earth Observation Data

The Central Park Conservancy stewards New York City’s iconic Central Park with a mission to preserve the park for all. This mission is complicated by the spread of Dutch elm disease (DED) which has threatened the culturally and ecologically significant American elm tree (Ulmus americana). Central Park is home to one of the largest and last remaining urban concentrations of American elm and the Conservancy currently protects them through integrated pest management. This paper discusses an interdisciplinary feasibility study that assessed the application of NASA Earth observations from 2014 to 2023 to detect changes in forest phenology possibly related to DED. Landsat 8 and 9 imagery was used to calculate multiyear time series of the Normalized Difference Vegetation Index (NDVI) and quantify changes in land surface phenology for a given year. A pixel-based logistic regression analysis was performed using changes in NDVI, tree site locations, and recorded occurrences of trees infected with DED as inputs. The results of this analysis show that changes in NDVI derived from Landsat data are capable of detecting unhealthy tree canopies with 71% precision and healthy tree canopies with 41% precision. The study had uncertainties and limitations due to the spatial and temporal resolutions of Landsat, the natural variability in land surface phenology and NDVI, and the attempt to detect disease impacts while disease prevention and mitigation is occurring. As is, the findings of this study and its methods provide managers with an approach for integrating Earth observations to make more informed decisions in the application and timing of urban forest management activities.

Central Park↗

Nexus of thermal resilience and energy efficiency in buildings: A case study of a nursing home

Extreme weather events become more frequent and severe due to climate change. Although energy efficiency technologies can influence thermal resilience of buildings, they are traditionally studied separately, and their interconnections are rarely quantified. This study developed a methodology of modeling and analysis to provide insights into the nexus of thermal resilience and energy efficiency of buildings. In this work, we conducted a case study of a real nursing home in Florida, where 12 patients died during Hurricane Irma in 2017 due to HVAC system power loss, to understand and quantify how passive and active energy efficiency measures (EEMs) can improve thermal resilience to reduce heat-exposure risk of patients. Results show that passive measures of opening windows and doors for natural ventilation, as well as miscellaneous load reduction, are very effective in eliminating the extreme dangerous occasions. However, to maintain safe conditions, active measures such as on-site power generators and thermal storage are also needed. The nursing home was further studied by changing its location to two other cities: San Francisco (mild climate) and Chicago (cold winter and hot summer). Results revealed that the EEMs' impacts on thermal resilience vary significantly by climate and building characteristics. The study also estimated the costs of EEMs to help stakeholders prioritize the measures. Passive measures that may not save energy may greatly improve thermal resilience, and thus should be considered in building design or retrofit. Findings from this study indicate energy efficiency technologies should be evaluated not only by their energy savings performance but also by their influence on a building's resilience to extreme weather events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Explaining drivers of housing prices with nonlinear hedonic regressions

Housing markets play a critical role in shaping the spatial and demographic evolution of urban areas. Simulating housing price dynamics can enhance projections of future urban development outcomes. However, traditional hedonic regressions for housing prices, which neglect nonlinear interactions among explanatory variables, often exhibit limited predictive performance. While machine learning (ML) methods can provide a more flexible representation of the relationships between predictors, they are often regarded as “black boxes” due to their complexity and lack of transparency. Interpretable ML techniques provide a promising route by combining the flexibility of ML methods with approaches to analyze the relationships between inputs and outputs. In this study, we employ interpretable ML to analyze the patterns driving the housing market in Baltimore, Maryland, USA. We train an Artificial Neural Network (ANN) to predict Baltimore housing prices based on structural characteristics (e.g., home size, number of stories) and locational attributes (e.g., distance to the city center). We then conduct sensitivity and Partial Dependence Plot (PDP) analyses to interpret the fitted ANN model. We find that the ML model achieves higher predictive accuracy and explains 16 % more of housing price variance than a traditional linear regression model. The interpretable ML model also reveals more nuanced and realistic nonlinear relationships between housing sales price and predictors as well as interactive effects underlying Baltimore home price dynamics. For instance, while the linear model indicates a steady housing price increase over time, our interpretable ML model detects a post-2008 decline, with smaller properties experiencing the sharpest drop.

97 MATHEMATICS AND COMPUTING↗

Automating the interpretation of PM 2.5 time–resolved measurements using a data–driven approach

The rapid development of automated measurement equipment enables researchers to collect greater quantities of time-resolved data from indoor and outdoor environments. While significant, the interpretation of the resulting data can be a time-consuming effort. This paper introduces an automated process of interpreting PM 2.5 time-resolved data and differentiating PM 2.5 emissions resulting from indoor and outdoor sources. Here, we use Random Forest (RF), a machine learning approach, to study a dataset of 836 indoor emission events that occurred over a 2-week period in 18 apartments in California. In this paper, we show model development and evaluate its performance as the sample size and source vary. We discuss the characteristics of the dataset that tended to help the source identification and why. For example, we show that data from many events and from different apartments are essential for the model to be suitable for analyzing a new separate dataset. We also show that longitudinal data appear to be more helpful than the time frequency of measurements within a given apartment. We use the resulting RF model to analyze PM 2.5 data of an entirely separate dataset collected from 65 new homes in California. The RF model identifies 442 indoor emission events, with only a few misidentifications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residual value analysis of plug-in vehicles in the United States

Knowledge about the value of used plug-in electric vehicles (PEVs), known as residual value, is critical for potential PEV purchasers, corporations, and governments who wish to consider the lifetime cost effectiveness of PEVs. In this study, we investigate the residual values of PEVs and compare them with those of other vehicle powertrain technologies using the “true market value” data from Edmunds.com, and considering U.S. federal incentives. We define the adjusted retention rate as the ratio between resale value and the manufacturer’s suggested retail price, subtracting incentives. We develop statistical models to quantify the effects of powertrain technologies on residual value while controlling key factors, including vehicle size, brand, and market segments. We find that the long-range high-performance Tesla Model S holds value significantly better than any other vehicle type evaluated, including internal combustion engine vehicles. Hybrid electric vehicles and plugin hybrid electric vehicles are comparable to one another. They hold slightly less value than internal combustion engine vehicles, but significantly more than short-range (<125 miles) battery electric vehicles. However, short-range battery electric vehicles have a faster improvement in 3-year adjusted retention rate than any other powertrain technology from model year 2013–2014. Finally, the other factor that significantly influences adjusted retention rate is the home country of the vehicle manufacturer (e.g., United States, Japan, or Germany).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Model-Predictive Hierarchical-Control Framework for Aggregating Residential DERs to Provide Grid Regulation Services

This paper develops a hierarchical control frame-work to aggregate and to manage behind-the-meter distributed energy resources (DERs), which will be ubiquitous in future distribution systems. In the proposed framework, firstly, each controller in the hierarchy determines the flexibility of the DERs such that the obtained flexibility is feasible with respect to its operational purview. For example, the operational purview of a home energy management system may only consider consumer comfort preferences, while that for an aggregator or a grid controller may consider network voltage management as well. Based on the feasible flexibility, optimal setpoints for the DERs is then determined by the hierarchical controllers to help the distribution power network in voltage regulation, coordination issues with existing transmission-level conventional generators, etc. Therefore, the proposed strategy, which is based on model-predictive control, can be effectively utilized by the distribution network to coordinate several DERs to provide grid regulation services. Numerical simulations performed on the IEEE 37-bus test system demonstrate the efficacy of the proposed approach.

behind-the-meter↗

Overcoming the Technical Challenges of Coordinating Distributed Load Resources at Scale (Final Report)

Significant recent research has investigated the potential for loads to provide balancing services to the grid. However, this research has not addressed key issues that may arise when such schemes are applied at scale including: 1. Distribution Network Issues. Coordination of large numbers of loads could result in power flows that violate distribution network constraints; 2. Stability Issues. Certain strategies to control loads can exhibit nonlinearity in the form of period-adding bifurcations and chaos. Other control strategies can potentially synchronize the behavior of large numbers of loads. In both cases, the outcome can be power oscillations and instability; 3. Communication Network Issues. Bidirectional low-latency communication channels between a central controller (or several distributed controllers) and each resource are expensive and likely not necessary for effective coordination. Our research questions were: What network, stability, and communication issues might arise in practice when we coordinate large aggregations of loads? How can we coordinate loads to achieve performance objectives in a cost effective manner while avoiding these issues? The ultimate technical goal of the project was the development of network-aware, communication-constrained, non-disruptive load control strategies with stability guarantees that achieve the performance requirements of typical balancing services at a sufficiently low cost to enable the load aggregator and customer to profit. The overall goal was to establish credibility for load control at scale and contribute to U.S. energy security and environmental goals. The team succeeded in answering these research questions and developing these control strategies. The overall approach was based on the development of three testing environments: a simulation testbed, an experimental testbed (20 physical model houses with window-box air conditioners) coupled with the simulation testbed, and a field testbed (100 actual homes in Austin, TX) coupled with the simulation testbed, which enabled controller testing, identification of issues, controller development, and controller validation. The resulting controller was used to demonstrate fast timescale grid balancing (frequency regulation) by aggregations of physical and virtual air conditioners, with sufficient quality to participate in the electricity market. Cost benefit analysis showed overall benefits to the participating households, load aggregators, and the grid, especially if the control technology was integrated directly into existing programmable communicating thermostats. The project provides a variety of wider benefits. Our technology transfer and outreach activities lead us to choose an open-source licensing commercialization pathway, enabling the project results to be available to researchers, industry, and the public. Furthermore, new grid balancing technologies will increase grid flexibility and will enable higher penetrations of intermittent renewable energy resources, such as wind and solar, to be connected to the grid, reducing its environmental impact, and mitigating climate change to the benefit of society.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Exploration and Life Detection Sampling Through Planetary Analogue Sampling (FELDSPAR).

Exploration missions to Mars rely on rovers to perform analyses over small sampling areas; however, landing sites for these missions are selected based on large-scale, low-resolution remote data. The use of Earth analogue environments to estimate the multi-scale spatial distributions of key signatures of habitability can help ensure mission science goals are met. A main goal of FELDSPAR is to conduct field operations analogous to Mars sample return in its science, operations, and technology from landing site selection, to in-field sampling location selection, remote or stand-off analysis, in situ analysis, and home laboratory analysis. Lava fields and volcanic regions are relevant analogues to Martian landscapes due to desiccation, low nutrient availability, and temperature extremes. Operationally, many Icelandic lava fields are remote enough to require that field expeditions address several sampling constraints that are experienced in robotic exploration, including in situ and sample return missions. The Fimmvruhls lava field was formed by a basaltic effusive eruption associated with the 2010 Eyjafjallajkull eruption. Mlifellssandur is a recently deglaciated plain to the north of the Myrdalsjkull glacier. Holuhraun was formed by a 2014 fissure eruptions just north of the large Vatnajkull glacier. Dyngjusandur is an alluvial plain apparently kept barren by repeated mechanical weathering. Informed by our 2013 expedition, we collected samples in nested triangular grids every decade from the 10 cm scale to the 1 km scale (as permitted by the size of the site). Satellite imagery is available for older sites, and for Mlifellssandur, Holuhraun, and Dyngjusandur we obtained overhead imagery at 1 m to 200 m elevation. PanCam-style photographs were taken in the field by sampling personnel. In-field reflectance spectroscopy was also obtained with an ASD spectrometer in Dyngjusandur. All sites chosen were 'homogeneous' in apparent color, morphology, moisture, grain size, and reflectance spectra at all scales greater than 10 cm. Field lab assays were conducted to monitor microbial habitation, including ATP quantification, qPCR for fungal, bacterial, and archaeal DNA, and direct cell imaging using fluorescence microscopy. Home laboratory analyses include Raman spectroscopy and community sequencing. ATP appeared to be significantly more sensitive to small changes in sampling location than qPCR or fluorescence microscopy. Bacterial and archaeal DNA content were more consistent at the smaller scales, but similarly variable across more distant sites. Conversely, cell counts and fungal DNA content have significant local variation but appear relatively homogeneous over scales of 1 km. ATP, bacterial DNA, and archaeal DNA content were relatively well correlated at many spatial scales. While we have observed spatial variation at various scales and are beginning to observe how that variation fluctuates over time as biodiversity recovers after an eruption, we do not yet fully understand what parameters lead to the observed spatial variation. Home laboratory analyses will help us further understand the elemental and structural composition of the basaltic matrices, but further field analyses are vital for the understanding how temperature, moisture, incident radiation, and so forth influence the habitability of a microclimate.

Field↗

Assateague Island National Seashore Ecological Forecasting: Characterizing Nearshore Suspended Sediments and Landcover Change Relative to Sediment Bypassing and Catastrophic Events

Assateague Island is located off the coast of Maryland and Virginia and serves as a home to sensitive species and habitats. However, infrastructure development disrupted the natural sediment transport processes of the barrier island, which accelerated erosion of the island’s shoreline. To counteract this, the United States Army Corps of Engineers (USACE) initiated semiannual sediment bypassing operations in 2004. Over time, financial constraints limited the amount of sediment deposition possible, leading to concerns over navigational issues in nearby channels and the possibility of the operations not providing their intended benefits. To address these issues, NASA DEVELOP partnered with the National Park Service NPS and USACE. The team performed time series analyses of nearshore suspended sediment from 2004-2020 and landcover change from 2006-2018 with satellite imagery from Landsat 5 Thematic Mapper (TM), Landsat 7 Enhanced Thematic Mapper Plus (ETM+), Landsat 8 Operational Land Imager (OLI), and Sentinel-2 MultiSpectral Instrument (MSI). The sediment transport analyses showed that suspended sediment levels are seasonally dependent. Meanwhile, historical land cover trends included a net increase in unconsolidated shore and a net decrease in open water. Land cover change was then forecast to 2021, 2031, and 2046 using the IDRISI TerrSet Land Change Modeler. The model predicted the most drastic land cover changes in the southern portion and the least on the eastern foreshore of the island. As a result, this project allows our partners to understand the impact of sediment bypassing operations more fully and make better-informed decisions regarding the island’s management.

M Colin Marvin↗

A Model-Predictive Hierarchical-Control Framework for Aggregating Residential DERs to Provide Grid Regulation Services

This paper develops a hierarchical control frame-work to aggregate and to manage behind-the-meter distributed energy resources (DERs), which will be ubiquitous in future distribution systems. In the proposed framework, firstly, each controller in the hierarchy determines the flexibility of the DERs such that the obtained flexibility is feasible with respect to its operational purview. For example, the operational purview of a home energy management system may only consider consumer comfort preferences, while that for an aggregator or a grid controller may consider network voltage management as well. Based on the feasible flexibility, optimal setpoints for the DERs is then determined by the hierarchical controllers to help the distribution power network in voltage regulation, coordination issues with existing transmission-level conventional generators, etc. Therefore, the proposed strategy, which is based on model-predictive control, can be effectively utilized by the distribution network to coordinate several DERs to provide grid regulation services. Numerical simulations performed on the IEEE 37-bus test system demonstrate the efficacy of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 2: Particle number and size

The use of wood as a fuel for home heating is a concern from an environmental health and safety perspective as biomass combustion appliances emit high concentrations of particulate matter. Wood burning significantly contributes to wintertime particulate matter concentrations in many states in the northern United States. Of particular concern are outdoor wood-fired hydronic heaters. These devices are concerning as they tend to have very large combustion chambers and typical use patterns can result in long periods of low output, which result in an increased particulate matter emission rate relative to high heat output operating conditions. In this study, the performance of two hydronic heaters operating under different combustion conditions, including four different heat output categories approximately corresponding to categories I–IV denoted in Environmental Protection Agency Method 28 Outdoor Wood-fired Hydronic Heaters, and during start-up and reloading events were investigated. Measurements of flue gas particulate number concentration and size for particles with aerodynamic diameters between 0.006 and 10 µm were made using a dilution sampling system. The measured particle number concentration in the flue gas was between 0.71 and 420 million particles per cubic centimeter and was dependent on fuel loading and heat output. For each hydronic heater tested, the highest average particle concentration was found at the beginning of each test during the cold-start condition. Additionally, the majority of the particles had aerodynamic diameters less than 0.100 µm (particles of this size made up between 64% and 97% of all particles) and less than 1% of all particles had aerodynamic diameters greater than 1 µm for all phases. For particles in the accumulation mode, between 0.100 and 1 µm, the mean particle diameter was dependent on fuel loading and heat output.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Highly-Efficient Microemulsion-Based Absorption Chillers for HVAC Application

Air conditioning is a necessity to achieve a comfortable, habitable home or office for many places in US. However, vapor compression air conditioners are largely made with chlorofluorocarbon refrigerants, or CFCs, which create problems for a world grappling with climate change. In addition, vapor compression air conditioners are driven by electricity. Cooling and heating represent one-third of building electrical energy consumption in US. An absorption chiller is different to vapor compression chillers or air conditioners because it doesn’t use conventional refrigerants, like CFC. Instead, they may use water as the refrigerant which is mixed with safe and nontoxic absorbents. The research performed in this project advanced the understanding of absorption cooling technology and its application in HVAC. Various technologies were explored to improve the performance of the desorber and absorber components in the absorption chillers.

42 ENGINEERING↗

Split HPWHs as an Efficient Solution for Multifamily Buildings with In-Unit Water Heaters

A quarter of all housing units in the United States are found in multifamily buildings, but few efficiency innovations have been made to improve electric water heating systems in this building type. Domestic hot water in multifamily buildings can either be provided by a large central water heater or smaller in-unit water heaters. Integrated heat pump water heaters that are installed in single-family homes are often a poor fit for individual multifamily units because the water heaters are often located in small internal closets. This confined space can limit the airflow to the heat pump, and the cold exhaust air can cause discomfort and reduced efficiency. Split CO2 HPWHs separate the tank from the heat pump, which allows for installation location flexibility. Further, CO2 heat pumps can operate under colder ambient conditions, making them a better fit for multifamily units across a wide range of climate regions. As part of a larger project to characterize split HPWH performance, we evaluated the feasibility of installing an additional, parallel tank that could provide hot water to a second housing unit using a single CO2 heat pump. This approach would reduce the first costs of these more expensive units. Based on the high draw volume that we imposed on both tanks, the same heat pump may be able to support more tanks, depending on hot water usage. This paper will describe the split CO2 HPWH technology, how the two-tank system was controlled, and results from our laboratory evaluation.

CO2 HPWH↗

Split HPWHs as an Efficient Solution for Multifamily Buildings with In-Unit Water Heaters: Preprint

A quarter of all housing units in the country are found in multifamily buildings but few efficiency innovations have been made to improve electric water heating systems in this building type. Domestic hot water in multifamily buildings can either be provided by a large central water heater or smaller in-unit water heaters. Integrated heat pump water heaters that are installed in single family homes are often a poor fit for individual multifamily units since the water heaters are often located in small internal closets. This confined space can limit the air flow to the heat pump and the cold exhaust air can cause discomfort and reduced efficiency. Split CO2 HPWHs separate the tank from the heat pump, which allows for installation location flexibility. Further, CO2 heat pumps can operate under colder ambient conditions, making them a better fit for multifamily units across a wide range of climate regions. As part of a larger project to characterize split HPWH performance, we evaluated the feasibility of installing an additional, parallel tank that could provide hot water to a second housing unit using a single CO2 heat pump. This approach would reduce the first costs of these more expensive units. Based on the high draw volume that we imposed on both tanks, the same heat pump may be able to support more tanks, depending on hot water usage. This paper will describe the split CO2 HPWH technology, how the two-tank system was controlled, and results from our laboratory evaluation.

CO2 HPWH↗

Awe Bonner sphere measurements of the neutron leakage spectrum from the GODIVIA-IV critical assembly at NCERC - 14413

The US National Criticality Experiments Research Centre (NCERC) is home to several critical assembly machines that were relocated from Los Alamos National Laboratory in the last decade. The centre is sponsored by the Department of Energy's Nuclear Criticality Safety Program (NCSP), which has the mission to ensure the safe handling of fissile materials from a criticality perspective. Under the auspices of the NCSP, Lawrence Livermore National Laboratory (LLNL) is planning to host an international inter-comparison of nuclear accident dosimetry (NAD) using the Godiva-IV assembly at NCERC. The inter-comparison is motivated by a decline in the frequency of performance testing of NADs (both in the US, the UK and France) and the desire to modernize and harmonize dosimetry systems. A pre-requisite for the inter-comparison is the characterisation of the neutron and gamma-ray leakage spectra associated with the Godiva-IV assembly at NCERC. AWE provided its Bonner-sphere spectrometry capability to LLNL for two experimental campaigns, in November 2013 and May 2014, to measure the neutron leakage spectrum of the assembly in both a sub-critical 'steady-state' and a super-prompt-critical 'burst'. Nine points, at distances from 2 to 4 meters from the machine were measured with the Bonner-sphere spectrometer using both an active He-3 detector and a passive technique employing gold foils. This paper presents the spectra unfolded from the data and integral dose values, and compares these to previously published data. The limitations of the work and future plans are also discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Audit Report on "The Department of Energy's Opportunity for Energy Savings Through the Use of Setbacks in its Facilities"

Our testing at Office of Science and National Nuclear Security Administration facilities revealed that the Department either did not use or failed to properly maintain setback systems and equipment in a number of instances. At just the four sites we visited, the Department had not ensured that setback conservation methods were used for 35 of the 55 (approximately 64 percent) owned or leased buildings included in our review. The buildings that did not use setbacks capabilities to control energy consumption comprised over one million square feet of space. Specifically: Although in place or capable of being deployed, officials did not utilize setbacks in 20 separate buildings; and, Equipment in 15 other buildings had either never been enabled or had deteriorated and was no longer functional, thus making setbacks impossible. Typical of the problems we noted, the Y-12 National Security Complex recently leased two buildings that were constructed with setback capability. The property manager for these buildings told us that the setback equipment was not used because the owner of the properties had not purchased the software necessary to enable the capability. In another case, we learned that Los Alamos National Laboratory was not using the setback capability in two buildings because facility operators and tenants had not been trained on operating the setback control system. Finally, the Oak Ridge National Laboratory lost the ability to operate the setback equipment in two buildings when the electronic control system failed in 2008. Laboratory officials told us that they elected not to replace it because they planned to implement campus-wide energy conservation measures in the future. In spite of its energy conservation leadership role, we found that the Department and its facility contractors did not place adequate emphasis on reducing energy consumption through the application of setbacks. Of particular significance, we found that the Department had not always required the operation of setback capabilities in building lease agreements. This was especially troubling given the expanded use of leased space to house Departmental operations. Despite discussions with several Federal and contractor officials, we could not obtain what we considered to be a satisfactory explanation as to why the Department failed to take advantage of this conservation practice, one that is generally low cost and has limited, if any, adverse impact on operations or building occupants. Consistent with the lack of emphasis in this area, we noted that the Department had not required the four contractors included in our review to develop training requirements or energy policies and procedures governing the use of setback capabilities. Energy consumption reduction goals related to setbacks had also not been established to help incentivize contractor performance in this important area. With nearly $300 million in annual utility costs, the Department could realize significant savings by using setbacks in its buildings. We estimate that the Department could save over $11.5 million in annual utility costs. We developed the estimate based on the observation that approximately 64 percent of the facilities included in our review had not used setbacks. We then conservatively applied a 15 percent energy consumption savings estimate observed by Sandia National Laboratory and savings estimates contained in a study conducted by Pacific Northwest National Laboratory to the 40 percent of utility costs generally recognized as resulting from HVAC operation. Such savings could be used to fund high priority programs and install additional energy saving features. The consumption savings would be, at today's average residential electricity cost, sufficient to power over 9,800 homes each year. We recognize that while setbacks can be used in many situations, they are not appropriate for facilities that are continuously operated or those that house delicate equipment that depend on constant temperatures. However, during the course of our audit officials at four of the sites included in our review told us that they recognized the utility of using setbacks for most facilities. At two sites, implementation efforts began almost immediately after we briefed officials on our findings. We also noted that Department Headquarters facilities used setbacks in offices and many common areas. With over 9,000 buildings in its inventory, the consistent use of setbacks can help the Department significantly reduce its energy consumption and, as noted above, achieve substantial cost savings. Actions related to setbacks that officials began after we initiated our audit are noteworthy and should, if fully implemented, help further reduce energy consumption. However, additional action at sites across the complex is necessary to maximize energy efficient operations and to establish the Department as the leader in this effort in all of the Federal sector.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

An Analysis of Representative Heating Load Lines for Residential HSPF Ratings

This report describes an analysis to investigate representative heating loads for single-family detached homes using current EnergyPlus simulations (DOE 2014a). Hourly delivered load results are used to determine binned load lines using US Department of Energy (DOE) residential prototype building models (DOE 2014b) developed by Pacific Northwest National Laboratory (PNNL). The selected residential single-family prototype buildings are based on the 2006 International Energy Conservation Code (IECC 2006) in the DOE climate regions. The resulting load lines are compared with the American National Standards Institute (ANSI)/Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Standard 210/240 (AHRI 2008) minimum and maximum design heating requirement (DHR) load lines of the heating seasonal performance factor (HSPF) ratings procedure for each region. The results indicate that a heating load line closer to the maximum DHR load line, and with a lower zero load ambient temperature, is more representative of heating loads predicted for EnergyPlus prototype residential buildings than the minimum DHR load line presently used to determine HSPF ratings. An alternative heating load line equation was developed and compared to binned load lines obtained from the EnergyPlus simulation results. The effect on HSPF of the alternative heating load line was evaluated for single-speed and two-capacity heat pumps, and an average HSPF reduction of 16% was found. The alternative heating load line relationship is tied to the rated cooling capacity of the heat pump based on EnergyPlus autosizing, which is more representative of the house load characteristics than the rated heating capacity. The alternative heating load line equation was found to be independent of climate for the six DOE climate regions investigated, provided an adjustable zero load ambient temperature is used. For Region IV, the default DOE climate region used for HSPF ratings, the higher load line results in an ~28% increase in delivered heating load and an ~52% increase in the estimated heating operating cost over that given in the AHRI directory (AHRI 2014).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗