Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Fundamental reliability of 1.5-nm-thick silicon oxide gate films grown at 150 deg. C by modified reactive ion beam deposition

The reliability of 1.5-nm-thick silicon oxide gate films grown at 150 deg. C by modified reactive ion beam deposition (RIBD) with in situ pyrolytic-gas passivation (PGP) using N{sub 2}O and NF{sub 3} was investigated. RIBD uses low-energy-controlled reactive, ionized species and potentializes low-temperature film growth. Although the oxide films were grown at a low temperature of 150 deg. C, their fundamental indices of reliability, such as the time-dependent dielectric breakdown lifetime and interface state density, were almost equivalent to those of oxide films grown at 850 deg. C using a furnace. This is probably due to localized interfacial N and F atoms. The number density of interfacial N atoms was about seven times larger than that for the furnace-grown oxide films, and this is a key factor for improving the reliability through the compensation of residual inconsistent-state bonding sites.

36 MATERIALS SCIENCE↗

Effect of proton irradiation dose on InAlN/GaN metal-oxide semiconductor high electron mobility transistors with Al 2 O 3 gate oxide

The effects of proton irradiation on the dc performance of InAlN/GaN metal-oxide-semiconductor high electron mobility transistors (MOSHEMTs) with Al 2 O 3 as the gate oxide were investigated. The InAlN/GaN MOSHEMTs were irradiated with doses ranging from 1×10 13 to 1×10 15 cm –2 at a fixed energy of 5MeV. There was minimal damage induced in the two dimensional electron gas at the lowest irradiation dose with no measurable increase in sheet resistance, whereas a 9.7% increase of the sheet resistance was observed at the highest irradiation dose. By sharp contrast, all irradiation doses created more severe degradation in the Ohmic metal contacts, with increases of specific contact resistance from 54% to 114% over the range of doses investigated. These resulted in source-drain current–voltage decreases ranging from 96 to 242 mA/mm over this dose range. The trap density determined from temperature dependent drain current subthreshold swing measurements increased from 1.6 × 10 13 cm –2 V –1 for the reference MOSHEMTs to 6.7 × 10 13 cm –2 V –1 for devices irradiated with the highest dose. In conclusion, the carrier removal rate was 1287 ± 64 cm –1 , higher than the authors previously observed in AlGaN/GaN MOSHEMTs for the same proton energy and consistent with the lower average bond energy of the InAlN.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three dimensional time-gated tracking of non-blinking quantum dots in live cells

Single particle tracking has provided a wealth of information about biophysical processes such as motor protein transport and diffusion in cell membranes. However, motion out of the plane of the microscope or blinking of the fluorescent probe used as a label generally limits observation times to several seconds. Here, we overcome these limitations by using novel non-blinking quantum dots as probes and employing a custom 3D tracking microscope to actively follow motion in three dimensions (3D) in live cells. As a result, signal-to-noise is improved in the cellular milieu through the use of pulsed excitation and time-gated detection.

59 BASIC BIOLOGICAL SCIENCES↗

Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro-CT

Recent advances in murine cardiac studies with three-dimensional (3D) cone beam micro-CT used a retrospective gating technique. However, this sampling technique results in a limited number of projections with an irregular angular distribution due to the temporal resolution requirements and radiation dose restrictions. Both angular irregularity and undersampling complicate the reconstruction process, since they cause significant streaking artifacts. This work provides an iterative reconstruction solution to address this particular challenge. A sparseness prior regularized weighted l{sub 2} norm optimization is proposed to mitigate streaking artifacts based on the fact that most medical images are compressible. Total variation is implemented in this work as the regularizer for its simplicity. Comparison studies are conducted on a 3D cardiac mouse phantom generated with experimental data. After optimization, the method is applied to in vivo cardiac micro-CT data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-67: Evaluation of Breathing Patterns for Respiratory-Gated Radiation Therapy Using Respiration Regularity Index

Purpose: Despite the importance of accurately estimating the respiration regularity of a patient in motion compensation treatment, an effective and simply applicable method has rarely been reported. The authors propose a simple respiration regularity index based on parameters derived from a correspondingly simplified respiration model. Methods: In order to simplify a patient's breathing pattern while preserving the data's intrinsic properties, we defined a respiration model as a power of cosine form with a baseline drift. According to this respiration formula, breathing-pattern fluctuation could be explained using four factors: sample standard deviation of respiration period, sample standard deviation of amplitude and the results of simple regression of the baseline drift (slope and standard deviation of residuals of a respiration signal. Overall irregularity (δ) was defined as a Euclidean norm of newly derived variable using principal component analysis (PCA) for the four fluctuation parameters. Finally, the proposed respiration regularity index was defined as ρ=ln(1+(1/ δ))/2, a higher ρ indicating a more regular breathing pattern. Subsequently, we applied it to simulated and clinical respiration signals from real-time position management (RPM; Varian Medical Systems, Palo Alto, CA) and investigated respiration regularity. Moreover, correlations between the regularity of the first session and the remaining fractions were investigated using Pearson's correlation coefficient. Results: The respiration regularity was determined based on ρ; patients with ρ<0.3 showed worse regularity than the others, whereas ρ>0.7 was suitable for respiratory-gated radiation therapy (RGRT). Fluctuations in breathing cycle and amplitude were especially determinative of ρ. If the respiration regularity of a patient's first session was known, it could be estimated through subsequent sessions. Conclusions: Respiration regularity could be objectively determined using a respiration regularity index, ρ. Such single-index testing of respiration regularity can facilitate determination of RGRT availability in clinical settings, especially for free-breathing cases. This work was supported by a Korea Science and Engineering Foundation (KOSEF) grant funded by the Korean Ministry of Science, ICT and Future Planning (No. 2013043498)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-144: Low Activity Studies of Carbon 11 Activation Via GATE Monte Carlo

Purpose: To investigate the behavior of a Monte Carlo simulation code with low levels of activity (∼1,000Bq). Such activity levels are expected from phantoms and patients activated via a proton therapy beam. Methods: Three different ranges for a therapeutic proton radiation beam were examined in a Monte Carlo simulation code: 13.5, 17.0 and 21.0cm. For each range, the decay of an equivalent length{sup 11}C source and additional sources of length plus or minus one cm was studied in a benchmark PET simulation for activities of 1000, 2000 and 3000Bq. The ranges were chosen to coincide with a previous activation study, and the activities were chosen to coincide with the approximate level of isotope creation expected in a phantom or patient irradiated by a therapeutic proton beam. The GATE 7.0 simulation was completed on a cluster node, running Scientific Linux Carbon 6 (Red Hat©). The resulting Monte Carlo data were investigated with the ROOT (CERN) analysis tool. The half-life of{sup 11}C was extracted via a histogram fit to the number of simulated PET events vs. time. Results: The average slope of the deviation of the extracted carbon half life from the expected/nominal value vs. activity showed a generally positive value. This was unexpected, as the deviation should, in principal, decrease with increased activity and lower statistical uncertainty. Conclusion: For activity levels on the order of 1,000Bq, the behavior of a benchmark PET test was somewhat unexpected. It is important to be aware of the limitations of low activity PET images, and low activity Monte Carlo simulations. This work was funded in part by the Philips corporation.

60 APPLIED LIFE SCIENCES↗

SU-E-T-507: Internal Dosimetry in Nuclear Medicine Using GATE and XCAT Phantom: A Simulation Study

Purpose Monte Carlo simulations are routinely used for internal dosimetry studies. These studies are conducted with humanoid phantoms such as the XCAT phantom. In this abstract we present the absorbed doses for various pairs of source and target organs using three common radiotracers in nuclear medicine. Methods The GATE software package is used for the Monte Carlo simulations. A typical female XCAT phantom is used as the input. Three radiotracers 153Sm, 131I and 99mTc are studied. The Specific Absorbed Fraction (SAF) for gamma rays (99mTc, 153Sm and 131I) and Specific Fraction (SF) for beta particles (153Sm and 131I) are calculated for all 100 pairs of source target organs including brain, liver, lung, pancreas, kidney, adrenal, spleen, rib bone, bladder and ovaries. Results The source organs themselves gain the highest absorbed dose as compared to other organs. The dose is found to be inversely proportional to distance from the source organ. In SAF results of 153Sm, when the source organ is lung, the rib bone, gain 0.0730 (Kg-1) that is more than lung itself. Conclusion The absorbed dose for various organs was studied in terms of SAF and SF. Such studies hold importance for future therapeutic procedures and optimization of induced radiotracer.

60 APPLIED LIFE SCIENCES↗

Monte Carlo simulations of the dose from imaging with GE eXplore 120 micro-CT using GATE

Purpose: Small animals are increasingly used as translational models in preclinical imaging studies involving microCT, during which the subjects can be exposed to large amounts of radiation. While the radiation levels are generally sublethal, studies have shown that low-level radiation can change physiological parameters in mice. In order to rule out any influence of radiation on the outcome of such experiments, or resulting deterministic effects in the subjects, the levels of radiation involved need to be addressed. The aim of this study was to investigate the radiation dose delivered by the GE eXplore 120 microCT non-invasively using Monte Carlo simulations in GATE and to compare results to previously obtained experimental values. Methods: Tungsten X-ray spectra were simulated at 70, 80, and 97 kVp using an analytical tool and their half-value layers were simulated for spectra validation against experimentally measured values of the physical X-ray tube. A Monte Carlo model of the microCT system was set up and four protocols that are regularly applied to live animal scanning were implemented. The computed tomography dose index (CTDI) inside a PMMA phantom was derived and multiple field of view acquisitions were simulated using the PMMA phantom, a representative mouse and rat. Results: Simulated half-value layers agreed with experimentally obtained results within a 7% error window. The CTDI ranged from 20 to 56 mGy and closely matched experimental values. Derived organ doses in mice reached 459 mGy in bones and up to 200 mGy in soft tissue organs using the highest energy protocol. Dose levels in rats were lower due to the increased mass of the animal compared to mice. The uncertainty of all dose simulations was below 14%. Conclusions: Monte Carlo simulations proved a valuable tool to investigate the 3D dose distribution in animals from microCT. Small animals, especially mice (due to their small volume), receive large amounts of radiation from the GE eXplore 120 microCT, which might alter physiological parameters in a longitudinal study setup.

60 APPLIED LIFE SCIENCES↗

SU-F-I-11: Software Development for 4D-CBCT Research of Real-Time-Image Gated Spot Scanning Proton Therapy

Purpose: To acquire correct information for inside the body in patient positioning of Real-time-image Gated spot scanning Proton Therapy (RGPT), utilization of tomographic image at exhale phase of patient respiration obtained from 4-dimensional Cone beam CT (4D-CBCT) has been desired. We developed software named “Image Analysis Platform” for 4D-CBCT researches which has technique to segment projection-images based on 3D marker position in the body. The 3D marker position can be obtained by using two axes CBCT system at Hokkaido University Hospital Proton Therapy Center. Performance verification of the software was implemented. Methods: The software calculates 3D marker position retrospectively by using matching positions on pair projection-images obtained by two axes fluoroscopy mode of CBCT system. Log data of 3D marker tracking are outputted after the tracking. By linking the Log data and gantry-angle file of projection-image, all projection-images are equally segmented to spatial five-phases according to marker 3D position of SI direction and saved to specified phase folder. Segmented projection-images are used for CBCT reconstruction of each phase. As performance verification of the software, test of segmented projection-images was implemented for sample CT phantom (Catphan) image acquired by two axes fluoroscopy mode of CBCT. Dummy marker was added on the images. Motion of the marker was modeled to move in 3D space. Motion type of marker is sin4 wave function has amplitude 10.0 mm/5.0 mm/0 mm, cycle 4 s/4 s/0 s for SI/AP/RL direction. Results: The marker was tracked within 0.58 mm accuracy in 3D for all images, and it was confirmed that all projection-images were segmented and saved to each phase folder correctly. Conclusion: We developed software for 4D-CBCT research which can segment projection-image based on 3D marker position. It will be helpful to create high quality of 4D-CBCT reconstruction image for RGPT.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-09: Tumor Location Prediction Using Natural Respiratory Volume for Respiratory Gated Radiation Therapy (RGRT): System Verification Study

Purpose: Respiratory gated radiation therapy (RGRT) gives accurate results when a patient’s breathing is stable and regular. Thus, the patient should be fully aware during respiratory pattern training before undergoing the RGRT treatment. In order to bypass the process of respiratory pattern training, we propose a target location prediction system for RGRT that uses only natural respiratory volume, and confirm its application. Methods: In order to verify the proposed target location prediction system, an in-house phantom set was used. This set involves a chest phantom including target, external markers, and motion generator. Natural respiratory volume signals were generated using the random function in MATLAB code. In the chest phantom, the target takes a linear motion based on the respiratory signal. After a four-dimensional computed tomography (4DCT) scan of the in-house phantom, the motion trajectory was derived as a linear equation. The accuracy of the linear equation was compared with that of the motion algorithm used by the operating motion generator. In addition, we attempted target location prediction using random respiratory volume values. Results: The correspondence rate of the linear equation derived from the 4DCT images with the motion algorithm of the motion generator was 99.41%. In addition, the average error rate of target location prediction was 1.23% for 26 cases. Conclusion: We confirmed the applicability of our proposed target location prediction system for RGRT using natural respiratory volume. If additional clinical studies can be conducted, a more accurate prediction system can be realized without requiring respiratory pattern training.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-JeP2-01: 4D-MRI with 3D Radial Sampling and Self-Gating-Based K-Space Sorting: Image Quality Improvement by Slab-Selective Excitation

Purpose: A recent 4D MRI technique based on 3D radial sampling and self-gating-based K-space sorting has shown promising results in characterizing respiratory motion. However due to continuous acquisition and potentially drastic k-space undersampling resultant images could suffer from low blood-to-tissue contrast and streaking artifacts. In this study 3D radial sampling with slab-selective excitation (SS) was proposed in attempt to enhance blood-to-tissue contrast by exploiting the in-flow effect and to suppress the excess signal from the peripheral structures particularly in the superior-inferior direction. The feasibility of improving image quality by using this approach was investigated through a comparison with the previously developed non-selective excitation (NS) approach. Methods: Two excitation approaches SS and NS were compared in 5 cancer patients (1 lung 1 liver 2 pancreas and 1 esophagus) at 3Tesla. Image artifact was assessed in all patients on a 4-point scale (0: poor; 3: excellent). Signal-tonoise ratio (SNR) of the blood vessel (aorta) at the center of field-of-view and its nearby tissue were measured in 3 of the 5 patients (1 liver 2 pancreas) and blood-to-tissue contrast-to-noise ratio (CNR) were then determined. Results: Compared with NS the image quality of SS was visually improved with overall higher signal in all patients (2.6±0.55 vs. 3.4±0.55). SS showed an approximately 2-fold increase of SNR in the blood (aorta: 16.39±1.95 vs. 32.19±7.93) and slight increase in the surrounding tissue (liver/pancreas: 16.91±1.82 vs. 22.31±3.03). As a result the blood-totissue CNR was dramatically higher in the SS method (1.20±1.20 vs. 9.87±6.67). Conclusion: The proposed 3D radial sampling with slabselective excitation allows for reduced image artifact and improved blood SNR and blood-to-tissue CNR. The success of this technique could potentially benefit patients with cancerous tumors that have invaded the surrounding blood vessels where radiation therapy is needed to remove tumor from those regions prior to surgical resection. This work is partially supported by NIH R03CA173273; and CTSI core voucher award.

60 APPLIED LIFE SCIENCES↗

A GATE evaluation of the sources of error in quantitative {sup 90}Y PET

Purpose: Accurate reconstruction of the dose delivered by {sup 90}Y microspheres using a postembolization PET scan would permit the establishment of more accurate dose–response relationships for treatment of hepatocellular carcinoma with {sup 90}Y. However, the quality of the PET data obtained is compromised by several factors, including poor count statistics and a very high random fraction. This work uses Monte Carlo simulations to investigate what impact factors other than low count statistics have on the quantification of {sup 90}Y PET. Methods: PET acquisitions of two phantoms—a NEMA PET phantom and the NEMA IEC PET body phantom-containing either {sup 90}Y or {sup 18}F were simulated using GATE. Simulated projections were created with subsets of the simulation data allowing the contributions of random, scatter, and LSO background to be independently evaluated. The simulated projections were reconstructed using the commercial software for the simulated scanner, and the quantitative accuracy of the reconstruction and the contrast recovery of the reconstructed images were evaluated. Results: The quantitative accuracy of the {sup 90}Y reconstructions were not strongly influenced by the high random fraction present in the projection data, and the activity concentration was recovered to within 5% of the known value. The contrast recovery measured for simulated {sup 90}Y data was slightly poorer than that for simulated {sup 18}F data with similar count statistics. However, the degradation was not strongly linked to any particular factor. Using a more restricted energy range to reduce the random fraction in the projections had no significant effect. Conclusions: Simulations of {sup 90}Y PET confirm that quantitative {sup 90}Y is achievable with the same approach as that used for {sup 18}F, and that there is likely very little margin for improvement by attempting to model aspects unique to {sup 90}Y, such as the much higher random fraction or the presence of bremsstrahlung in the singles data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reconfiguring band-edge states and charge distribution of organic semiconductor–incorporated 2D perovskites via pressure gating

Two-dimensional (2D) semiconductor heterostructures are key building blocks for many electronic and optoelectronic devices. Reconfiguring the band-edge states and modulating their interplay with charge carriers at the interface in a continuous manner have long been sought yet are challenging. Here, using organic semiconductor–incorporated 2D halide perovskites as the model system, we realize the manipulation of band-edge states and charge distribution via mechanical—rather than chemical or thermal—regulation. Compression induces band-alignment switching and charge redistribution due to the different pressure responses of organic and inorganic building blocks, giving controllable emission properties of 2D perovskites. We propose and demonstrate a “pressure gating” strategy that enables the control of multiple emission states within a single material. We also reveal that band-alignment transition at the organic-inorganic interface is intrinsically not well resolved at room temperature owing to the thermally activated transfer and shuffling of band-edge carriers. This work provides important fundamental insights into the energetics and carrier dynamics of hybrid semiconductor heterostructures.

42 ENGINEERING↗

Dynamic gating of infrared radiation in a textile

The human body absorbs and loses heat largely through infrared radiation centering around a wavelength of 10 micrometers. However, neither our skin nor the textiles that make up clothing are capable of dynamically controlling this optical channel for thermal management. By coating triacetate-cellulose bimorph fibers with a thin layer of carbon nanotubes, we effectively modulated the infrared radiation by more than 35% as the relative humidity of the underlying skin changed. Both experiments and modeling suggest that this dynamic infrared gating effect mainly arises from distance-dependent electromagnetic coupling between neighboring coated fibers in the textile yarns. This effect opens a pathway for developing wearable localized thermal management systems that are autonomous and self-powered, as well as expanding our ability to adapt to demanding environments.

Science & Technology - Other Topics↗

Programming correlated magnetic states with gate-controlled moiré geometry

The ability to control the underlying lattice geometry of a system may enable transitions between emergent quantum ground states. We report in situ gate switching between honeycomb and triangular lattice geometries of an electron many-body Hamiltonian in rhombohedral (R)–stacked molybdenum ditelluride (MoTe 2 ) moiré bilayers, resulting in switchable magnetic exchange interactions. At zero electric field, we observed a correlated ferromagnetic insulator near one hole per moiré unit cell with a widely tunable Curie temperature up to 14 K. Applying an electric field switched the system into a half-filled triangular lattice with antiferromagnetic interactions; further doping this layer-polarized superlattice tuned the antiferromagnetic exchange interaction back to ferromagnetic. Our work demonstrates R-stacked MoTe 2 moirés to be a laboratory for engineering correlated states with nontrivial topology.

Science & Technology - Other Topics↗

Self-correction of field-effect transistor characteristics in the mode of spontaneous space-charge ion polarization of gate oxide

Spontaneous space-charge ion polarization of gate oxide in the inversion n-channel silicon field-effect transistor was accomplished in the mode of its Joule heating by the drain current I{sub d}. The transistor characteristics measured at room temperature (T{sub r}) before and after thermal-field treatment show that positive ion (Na{sup +}) localization near the SiO{sub 2}/Si interface is accompanied by an increase in the effective electron mobility (by a factor of {approx} 2.3), steepness, I{sub d}, and by a small decrease in the threshold voltage ({delta}V{sub th} = 0.58 V). At T = T{sub r}, the modified transistor characteristics are retained for months; they can be easily and predictably varied by changing I{sub d} and heating duration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of the shape of spin gate elements on their magnetic and magnetoresistive characteristics

The effect of the geometric shape of elements of a spin-dependent tunneling gate on their magnetic characteristic is studied theoretically and experimentally. The hysteresis dependences of the magnetization and magnetoresistance of rectangular, hexagonal, and ringed elements on the magnetic field are calculated for different characteristically geometric parameters of the elements. In the studies of the magneto-optical Kerr effect, magnetic hysteresis loops are observed. The calculated and experimental magnetization curves are compared, and qualitative agreement between the curves is gained.

36 MATERIALS SCIENCE↗

Thermally deposited Ag-doped CdS thin film transistors with high-k rare-earth oxide Nd{sub 2}O{sub 3} as gate dielectric

The performance of thermally deposited CdS thin film transistors doped with Ag has been reported. Ag-doped CdS thin films have been prepared using chemical method. High dielectric constant rare earth oxide Nd{sub 2}O{sub 3} has been used as gate insulator. The thin film trasistors are fabricated in coplanar electrode structure on ultrasonically cleaned glass substrates with a channel length of 50 {mu}m. The thin film transistors exhibit a high mobility of 4.3 cm{sup 2} V{sup -1} s{sup -1} and low threshold voltage of 1 V. The ON-OFF ratio of the thin film transistors is found as 10{sup 5}. The TFTs also exhibit good transconductance and gain band-width product of 1.15 Multiplication-Sign 10{sup -3} mho and 71 kHz respectively.

36 MATERIALS SCIENCE↗