Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

SU-E-J-51: Dose Response of Common Solid State Detectors in Homogeneous Transverse and Longitudinal Magnetic Fields

Purpose: Solid state radiation detectors are often used for dose profiles and percent depth dose measurements. The dose response of selected solid state detectors is evaluated in varying transverse and longitudinal magnetic fields for eventual use in MR-Linac devices. Methods: A PTW 60003 and IBA PFD detector were modeled in the Monte Carlo code PENELOPE, incorporating a magnetic field which was varied in strength and oriented both transversely and longitudinally with respect to the incident photon beam. The detectors' long axis was in turn oriented either parallel or perpendicular to the photon beam. Dose to the active volume of each detector was scored, and its ratio to dose with zero magnetic field strength (dose response) was determined. Accuracy of the simulations was evaluated by measurements using both chambers taken at low field with a small electromagnet. Simulations were also performed in a water phantom to compare to the in air results. Results: Significant dose response was found in transverse field geometries, nearing 20% at 1.5T. The response is highly dependent on relative orientations to the magnetic field and photon beam, and on detector composition. Low field measurements confirm these results. In the presence of longitudinal magnetic fields, the detectors exhibit little dose response, reaching 0.5–1% at 1.5T regardless of detector orientation. Water tank simulations compared well to the in air simulations when not at the beam periphery, where in transverse magnetic fields only, the water tank simulations differed from the in air results. Conclusion: Transverse magnetic fields can cause large deviations in dose response, and are highly position orientation dependent. Comparatively, longitudinal magnetic fields exhibit little to no dose response in each detector as a function of magnetic field strength. Water tank simulations show longitudinal fields are generally easier to work with, but each detector must be evaluated separately.

07 ISOTOPE AND RADIATION SOURCES↗

TU-H-BRA-02: The Physics of Magnetic Field Isolation in a Novel Compact Linear Accelerator Based MRI-Guided Radiation Therapy System

Purpose: To develop a method for isolating the MRI magnetic field from field-sensitive linear accelerator components at distances close to isocenter. Methods: A MRI-guided radiation therapy system has been designed that integrates a linear accelerator with simultaneous MR imaging. In order to accomplish this, the magnetron, port circulator, radiofrequency waveguide, gun driver, and linear accelerator needed to be placed in locations with low magnetic fields. The system was also required to be compact, so moving these components far from the main magnetic field and isocenter was not an option. The magnetic field sensitive components (exclusive of the waveguide) were placed in coaxial steel sleeves that were electrically and mechanically isolated and whose thickness and placement were optimized using E&M modeling software. Six sets of sleeves were placed 60° apart, 85 cm from isocenter. The Faraday effect occurs when the direction of propagation is parallel to the magnetic RF field component, rotating the RF polarization, subsequently diminishing RF power. The Faraday effect was avoided by orienting the waveguides such that the magnetic field RF component was parallel to the magnetic field. Results: The magnetic field within the shields was measured to be less than 40 Gauss, significantly below the amount needed for the magnetron and port circulator. Additional mu-metal was employed to reduce the magnetic field at the linear accelerator to less than 1 Gauss. The orientation of the RF waveguides allowed the RT transport with minimal loss and reflection. Conclusion: One of the major challenges in designing a compact linear accelerator based MRI-guided radiation therapy system, that of creating low magnetic field environments for the magnetic-field sensitive components, has been solved. The measured magnetic fields are sufficiently small to enable system integration. This work supported by ViewRay, Inc.

60 APPLIED LIFE SCIENCES↗

Distributed Magnetic Field and Temperature Monitoring for Superconducting Radio Frequency Cavities

The overall objective of the proposed Phase I program was to design, construct and demonstrate a fiber optic sensing system capable of providing temperature and magnetic field measurements with an enhanced spatial resolution that can be implemented over a large surface area (cryomodules) to survey superconducting radio frequency cavities and magnets. A magnetic field sensor capable of detecting fluxes on the order of 1 μT is required to detect the distribution of trapped flux on the cavity surface. A unique distributed magnetic field sensor was successfully designed and constructed to demonstrate the detection of magnetic fluxes less than 500 nT. The sensor leveraged the ultra-high sensitivity of Sentek’s picoDAS to measure the magnetostriction induced vibrations in a commercially available Metglas 2605 SC ribbon that was in physical contact with sensing fiber. Static magnetic fields were detected by applying an alternating current a copper wire proximate to the Metglas 2605SC ribbon to create an AC bias magnetic field. In an alternative approach, an AC bias magnetic field was applied to a special magnetic field sensing fiber with Metglas 2605SC cladding successfully detect a magnetic field flux of a 3 μT. Exhaustive testing was performed to characterize the dependency of sensor response on the direction of the applied magnetic field. Although the special sensing fiber based magnetic field sensor did not exhibit an observable dependence on the direction of the magnetic field, the Metglas 2605SC ribbon sensor exhibited a clear directional dependence. A wide variety of polymer materials were evaluated to enhance the temperature response of an FBG based sensor at cryogenic temperatures. The processing and performance challenges provided the motivation to develop a new simple cryogenic temperature sensor that uses a commercially available fiber optic splice protector. The EVA hot melt tube that becomes adhered to the optical fiber and the polyolefin outer tube that shrinks upon heating in the fusion splicer heater provide the high thermal expansion coefficient necessary to impart a significant strain on the FBG when exposed to cryogenic temperatures. The temperature sensitivity (Δ𝜆𝐵𝑟𝑎𝑔𝑔~ 62 𝑝𝑝𝑚/℃) of the FBG-based sensor was on par with the best reported to date. The simple design, use of readily available cost-effective materials, and well-established processing techniques lends this approach to the creation of hundreds to thousands of temperature sensors on one single optical fiber length. The inherently small form factor also allows for co-location with the distributed magnetic field sensor. In preparation for field testing of the prototype sensing system at the Jefferson Labs in potential Phase II program, several different cable designs were evaluated to package the sensors. The preliminary successful demonstration of fully functional sensing cables provides the foundation for subsequent development efforts to advance the Technology Readiness Level of the technology. The technical feasibility of the proposed approach was successfully demonstrated in this Phase I effort.

43 PARTICLE ACCELERATORS↗

Report on Non-Contact DC Electric Field Sensors

This document reports on methods used to measure DC electrostatic fields in the range of 100 to 4000 V/m using a non-contact method. The project for which this report is written requires this capability. Non-contact measurements of DC fields is complicated by the effect of the accumulation of random space-charges near the sensors which interfere with the measurement of the field-of-interest and consequently, many forms of field measurements are either limited to AC measurements or use oscillating devices to create pseudo-AC fields. The intent of this document is to report on methods discussed in the literature for non-contact measurement of DC fields. Electric field meters report either the electric field expressed in volts per distance or the voltage measured with respect to a ground reference. Common commercial applications for measuring static (DC) electric fields include measurement of surface charge on materials near electronic equipment to prevent arcing which can destroy sensitive electronic components, measurement of the potential for lightning to strike buildings or other exposed assets, measurement of the electric fields under power lines to investigate potential health risks from exposure to EM fields and measurement of fields emanating from the brain for brain diagnostic purposes. Companies that make electric field sensors include Trek (Medina, NY), MKS Instruments, Boltek, Campbell Systems, Mission Instruments, Monroe Electronics, AlphaLab, Inc. and others. In addition to commercial vendors, there are research activities continuing in the MEMS and optical arenas to make compact devices using the principles applied to the larger commercial sensors.

42 ENGINEERING↗

Origin of primordial magnetic fields

Magnetic fields of intensities similar to those in our galaxy are also observed in high redshift galaxies, where a mean field dynamo would not have had time to produce them. Therefore, a primordial origin is indicated. It has been suggested that magnetic fields were created at various primordial eras: during inflation, the electroweak phase transition, the quark-hadron phase transition (QHPT), during the formation of the first objects, and during reionization. We suggest here that the large-scale fields {approx}{mu}G, observed in galaxies at both high and low redshifts by Faraday rotation measurements (FRMs), have their origin in the electromagnetic fluctuations that naturally occurred in the dense hot plasma that existed just after the QHPT. We evolve the predicted fields to the present time. The size of the region containing a coherent magnetic field increased due to the fusion of smaller regions. Magnetic fields (MFs) {approx}10 {mu}G over a comoving {approx}1 pc region are predicted at redshift z{approx}10. These fields are orders of magnitude greater than those predicted in previous scenarios for creating primordial magnetic fields. Line-of-sight average MFs {approx}10{sup -2} {mu}G, valid for FRMs, are obtained over a 1 Mpc comoving region at the redshift z{approx}10. In the collapse to a galaxy (comoving size {approx}30 kpc) at z{approx}10, the fields are amplified to {approx}10 {mu}G. This indicates that the MFs created immediately after the QHPT (10{sup -4} s), predicted by the fluctuation-dissipation theorem, could be the origin of the {approx}{mu}G fields observed by FRMs in galaxies at both high and low redshifts. Our predicted MFs are shown to be consistent with present observations. We discuss the possibility that the predicted MFs could cause non-negligible deflections of ultrahigh energy cosmic rays and help create the observed isotropic distribution of their incoming directions. We also discuss the importance of the volume average magnetic field predicted by our model in producing the first stars and in reionizing the Universe.

58 GEOSCIENCES↗

Spinor Field Nonlinearity and Space-Time Geometry

Within the scope of Bianchi type VI,VI0,V, III, I, LRSBI and FRW cosmological models we have studied the role of nonlinear spinor field on the evolution of the Universe and the spinor field itself. It was found that due to the presence of non-trivial non-diagonal components of the energy-momentum tensor of the spinor field in the anisotropic space-time, there occur some severe restrictions both on the metric functions and on the components of the spinor field. In this report we have considered a polynomial nonlinearity which is a function of invariants constructed from the bilinear spinor forms. It is found that in case of a Bianchi type-VI space-time, depending of the sign of self-coupling constants, the model allows either late time acceleration or oscillatory mode of evolution. In case of a Bianchi VI{sub 0} type space-time due to the specific behavior of the spinor field we have two different scenarios. In one case the invariants constructed from bilinear spinor forms become trivial, thus giving rise to a massless and linear spinor field Lagrangian. This case is equivalent to the vacuum solution of the Bianchi VI{sub 0} type space-time. The second case allows non-vanishing massive and nonlinear terms and depending on the sign of coupling constants gives rise to accelerating mode of expansion or the one that after obtaining some maximum value contracts and ends in big crunch, consequently generating space-time singularity. In case of a Bianchi type-V model there occur two possibilities. In one case we found that the metric functions are similar to each other. In this case the Universe expands with acceleration if the self-coupling constant is taken to be a positive one, whereas a negative coupling constant gives rise to a cyclic or periodic solution. In the second case the spinor mass and the spinor field nonlinearity vanish and the Universe expands linearly in time. In case of a Bianchi type-III model the space-time remains locally rotationally symmetric all the time, though the isotropy of space-time can be attained for a large proportionality constant. As far as evolution is concerned, depending on the sign of coupling constant the model allows both accelerated and oscillatory mode of expansion. A negative coupling constant leads to an oscillatory mode of expansion, whereas a positive coupling constant generates expanding Universe with late time acceleration. Both deceleration parameter and EoS parameter in this case vary with time and are in agreement with modern concept of space-time evolution. In case of a Bianchi type-I space-time the non-diagonal components lead to three different possibilities. In case of a full BI space-time we find that the spinor field nonlinearity and the massive term vanish, hence the spinor field Lagrangian becomes massless and linear. In two other cases the space-time evolves into either LRSBI or FRW Universe. If we consider a locally rotationally symmetric BI(LRSBI) model, neither the mass term nor the spinor field nonlinearity vanishes. In this case depending on the sign of coupling constant we have either late time accelerated mode of expansion or oscillatory mode of evolution. In this case for an expanding Universe we have asymptotical isotropization. Finally, in case of a FRW model neither the mass term nor the spinor field nonlinearity vanishes. Like in LRSBI case we have either late time acceleration or cyclic mode of evolution. These findings allow us to conclude that the spinor field is very sensitive to the gravitational one.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Noninvasive Near‐Field Spectroscopy of Single Subwavelength Complementary Resonators

Abstract Subwavelength metallic resonators provide a route to achieving strong light–matter coupling by means of tight confinement of resonant electromagnetic fields. Investigation of such resonators however often presents experimental difficulties, particularly at terahertz (THz) frequencies. A single subwavelength resonator interacts weakly with THz beams, making it difficult to probe it using far‐field methods, whereas arrays of resonators exhibit inter‐resonator coupling, which affect the resonator spectral signature and field confinement. Here, traditional far‐field THz spectroscopy is systematically compared with aperture‐type THz near‐field microscopy for investigating complementary THz resonators. While the far‐field method proves impractical for measuring single resonators, the near‐field technique gives high signal‐to‐noise spectral information, only achievable in the far‐field with resonator arrays. At the same time, the near‐field technique allows to analyze single resonators without significant interaction with the near‐field probe. Furthermore, the near‐field technique allows highly confined fields and surface waves to be mapped in space and time. This information gives invaluable insight into spectral response in resonator arrays. This near‐field microscopy and spectroscopy method enables investigations of strong light–matter coupling at THz frequencies in the single‐resonator regime.

Hale, Lucy L.↗

Improvement of Prostate Treatment by Anterior Proton Fields

Purpose: We performed a treatment planning study to demonstrate the potential dosimetric benefits of anterior-oriented fields for prostate irradiation by proton beam. A novel in vivo beam range control method shows millimeter accuracy, suggesting that such fields could be safely used to spare the rectum given the sharp distal penumbra of protons. Methods and Materials: Ten prostate patients treated with water-filled endorectal balloon were selected. Bilateral fields were planned following the conventional treatment protocol. Three anterior-oriented fields (0, +30, -30 Degree-Sign ) were planned, with the range compensators manually adjusted to improve rectal sparing. Dose distributions to the clinical target volume, rectum, anterior rectal wall (ARW), bladder, bladder wall (BW), and femoral heads were compared for: A) equally weighted bilateral fields, B) a single straight anterior field, and C) two equally weighted anterior-oblique fields. Results: The anterior-oriented fields required much less beam energy, {approx}10 cm water equivalent path length less than lateral fields. For ARW, the V{sub 95%} for Plans A, B, and C were 39%, 8%, and 6%, respectively; the corresponding V{sub 80%} were 59%, 27%, and 26%, respectively (p = 0.002 when Plan A was compared with B or C). Plan B irradiated a larger volume of BW than did Plan A by 3% at V{sub 95%}, 11% at V{sub 80%}, and 16% at V{sub 50%} (p = 0.002), whereas Plan C differs little from Plan A for BW at these dose levels. The femoral heads received {approx}40% of the prescription dose in Plan A, but negligible dose in Plans B and C. Conclusions: Compared to lateral fields, anterior-oriented fields can significantly reduce dose to the ARW, particularly at high dose levels. These fields alone, or in combination with lateral fields, allow for the possibility of either reducing treatment toxicity at current prescription doses or further dose escalation in the treatment of prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A comparison of small-field tissue phantom ratio data generation methods for an Elekta Agility 6 MV photon beam

Tissue-phantom ratios (TPRs) are a common dosimetric quantity used to describe the change in dose with depth in tissue. These can be challenging and time consuming to measure. The conversion of percentage depth dose (PDD) data using standard formulae is widely employed as an alternative method in generating TPR. However, the applicability of these formulae for small fields has been questioned in the literature. Functional representation has also been proposed for small-field TPR production. This article compares measured TPR data for small 6 MV photon fields against that generated by conversion of PDD using standard formulae to assess the efficacy of the conversion data. By functionally fitting the measured TPR data for square fields greater than 4 cm in length, the TPR curves for smaller fields are generated and compared with measurements. TPRs and PDDs were measured in a water tank for a range of square field sizes. The PDDs were converted to TPRs using standard formulae. TPRs for fields of 4 × 4 cm{sup 2} and larger were used to create functional fits. The parameterization coefficients were used to construct extrapolated TPR curves for 1 × 1 cm{sup 2}, 2 × 2-cm{sup 2}, and 3 × 3-cm{sup 2} fields. The TPR data generated using standard formulae were in excellent agreement with direct TPR measurements. The TPR data for 1 × 1-cm{sup 2}, 2 × 2-cm{sup 2}, and 3 × 3-cm{sup 2} fields created by extrapolation of the larger field functional fits gave inaccurate initial results. The corresponding mean differences for the 3 fields were 4.0%, 2.0%, and 0.9%. Generation of TPR data using a standard PDD-conversion methodology has been shown to give good agreement with our directly measured data for small fields. However, extrapolation of TPR data using the functional fit to fields of 4 × 4 cm{sup 2} or larger resulted in generation of TPR curves that did not compare well with the measured data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Proton imaging of stochastic magnetic fields

Recent laser-plasma experiments report the existence of dynamically significant magnetic fields, whose statistical characterization is essential for a complete understanding of the physical processes these experiments are attempting to investigate. In this paper, we show how a proton-imaging diagnostic can be used to determine a range of relevant magnetic-field statistics, including the magnetic-energy spectrum. To achieve this goal, we explore the properties of an analytic relation between a stochastic magnetic field and the image-flux distribution created upon imaging that field. This ‘Kugland image-flux relation’ was previously derived under simplifying assumptions typically valid in actual proton-imaging set-ups. We conclude that, as with regular electromagnetic fields, features of the beam’s final image-flux distribution often display a universal character determined by a single, field-scale dependent parameter – the contrast parameter $\unicode[STIX]{x1D707}\equiv d_{s}/{\mathcal{M}}l_{B}$ – which quantifies the relative size of the correlation length $l_{B}$ of the stochastic field, proton displacements $d_{s}$ due to magnetic deflections and the image magnification ${\mathcal{M}}$ . For stochastic magnetic fields, we establish the existence of four contrast regimes, under which proton-flux images relate to their parent fields in a qualitatively distinct manner. These are linear, nonlinear injective, caustic and diffusive. The diffusive regime is newly identified and characterized. The nonlinear injective regime is distinguished from the caustic regime in manifesting nonlinear behaviour, but as in the linear regime, the path-integrated magnetic field experienced by the beam can be extracted uniquely. Thus, in the linear and nonlinear injective regimes we show that the magnetic-energy spectrum can be obtained under a further statistical assumption of isotropy. This is not the case in the caustic or diffusive regimes. We discuss complications to the contrast-regime characterization arising for inhomogeneous, multi-scale stochastic fields, which can encompass many contrast regimes, as well as limitations currently placed by experimental capabilities on one’s ability to extract magnetic-field statistics. Furthermore, the results presented in this paper are of consequence in providing a comprehensive description of proton images of stochastic magnetic fields, with applications for improved analysis of proton-flux images.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Estimating the Electric Fields Driving Lightning Dart Leader Development With BIMAP‐3D Observations

Abstract In this paper, a numerical dart leader model has been implemented to understand the leader's development and the corresponding electric field changes observed by the 3D broadband mapping and polarization (BIMAP‐3D) system. The model assumes the extending leader channel is equipotential and has a linear charge distribution induced by an ambient electric field. The charge distribution induced by the ambient field can be used to model the electric field change at the ground. We then find the ambient electric field which best fits the field change measurements at the two BIMAP stations. The estimated ambient electric field decreases in the direction of dart leader propagation. Our observations and modeling results are consistent with our earlier hypothesis that dart leader speed is proportional to the electric field at the leader tip. The model also supports our earlier analysis that leader speed variations near branch junctions were due to previous charge deposits near the junctions. The modeled tip electric field is generally lower than the breakdown field unless the pre‐dart‐leader channel has a significant temperature of 3,000 K. This is consistent with the fact that dart leaders typically do not form new branches into the virgin air. Furthermore, the tip field is generally close to the negative streamer stability field at ambient temperatures, explaining the nature of the narrow and well‐defined channel structure. In addition to the charge distribution and the ambient and tip electric field, the development of the channel potential and current distribution are also presented.

3D lightning mapping↗

Macroscopic motion of sheath-connected blobs in magnetic fields with arbitrary topology

In this study, macroscopic motion of sheath-connected blobs in magnetic fields, having arbitrary topology of the field lines and unfrozen in plasma, is analyzed within the electrostatic limit. Two distinct cases of magnetic configurations, with small and large curvature of the field lines, are considered and the criterion to discern them is deduced. For magnetic configurations with small curvature of the field lines, it is demonstrated that asymmetry of plasma distribution at the blob ends can drive macroscopic motion of a filament due to formation of unequal sheath potentials and establishing the effective Boltzmann potential. For a specific case of magnetic fields with small curvature of the field lines and identical metrics at the sheaths, we show that macroscopic motion of a plasma filament is determined by an effective electrostatic potential, which remains constant in time. For magnetic configurations with large curvature of the field lines, it is shown that motion of sufficiently large blobs is governed by integral distribution of plasma and magnetic field parameters along the field lines leading to blob adjusting its shape and position to the lead of the magnetic field lines in the course of its motion, whereas propagation of small and medium sized blobs can be represented as mutually independent motion of filament transverse cross-sections across the magnetic field lines. In conclusion, the qualitative conclusions on regularities of filament motion are supplied with numerical simulations of blob dynamics in two cases of tokamak-like magnetic fields with sheared and non-sheared field lines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spherical compression of an applied magnetic field in inertial confinement fusion

Applying an external magnetic field to laser-driven inertial confinement fusion implosions is a promising approach for enhancing fusion yield. The field is compressed with the plasma, producing a magnetized hotspot that anisotropically suppresses thermal losses and traps alpha particles, making performance sensitive to the compressed field orientation. Here, we derive a simple, readily applicable analytic model that enables rapid evaluation of the compressed field topology and show that ablation into the hotspot amplifies the central field, while the ablated ice near the hotspot edge develops a decaying, radially bent field, with a discontinuity in the field direction. The radially bent field renders thermal insulation at the hotspot edge negligible and largely independent of the applied field strength, whereas insulation in the hotspot core still depends strongly on the applied field. Applying the model to non-axial initial field configurations, we find that an initially applied mirror field provides the greatest suppression, followed by the standard axial field.

Physics - Plasma physics↗

HYPERACCRETING DISKS AROUND MAGNETARS FOR GAMMA-RAY BURSTS: EFFECTS OF STRONG MAGNETIC FIELDS

Hyperaccreting neutron stars or magnetar disks cooled via neutrino emission can be candidates of gamma-ray burst (GRB) central engines. The strong field {>=}10{sup 15}-10{sup 16} G of a magnetar can play a significant role in affecting the disk properties and even lead to the funnel accretion process. In this paper, we investigate the effects of strong fields on the disks around magnetars, and discuss implications of such accreting magnetar systems for GRBs and GRB-like events. We discuss quantum effects of the strong fields on the disk thermodynamics and microphysics due to modifications of the electron distribution and energy in the strong field environment, and use the magnetohydrodynamical conservation equations to describe the behavior of the disk flow coupled with a large-scale field, which is generated by the star-disk interaction. If the disk field is open, the disk properties mainly depend on the ratio between |B {sub {phi}/}B{sub z}| and {Omega}/{Omega}{sub K} with B {sub {phi}} and B{sub z} being the azimuthal and vertical components of the disk field, and {Omega} and {Omega} {sub K} being the accretion flow angular velocity and Keplerian velocity, respectively. On the other hand, the disk properties also depend on the magnetar spin period if the disk field is closed. In general, stronger fields give higher disk densities, pressures, temperatures, and neutrino luminosity. Moreover, strong fields will change the electron fraction and degeneracy state significantly. A magnetized disk is always viscously stable outside the Alfven radius, but will be thermally unstable near the Alfven radius where the magnetic field plays a more important role in transferring the angular momentum and heating the disk than the viscous stress. The funnel accretion process will be important only for an extremely strong field, which creates a magnetosphere inside the Alfven radius and truncates the plane disk. Because of higher temperature and more concentrated neutrino emission of a ring-like belt region on the magnetar surface covered by funnel accretion, the neutrino annihilation rate from the accreting magnetar can be much higher than that from an accreting neutron star without fields. Furthermore, the neutrino annihilation mechanism, which releases the gravitational energy of the surrounding disk, and the magnetically driven pulsar wind, which extracts the stellar rotational energy from the magnetar surface, can work together to generate and feed an ultrarelativistic jet along the stellar magnetic poles.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantum spin ice response to a magnetic field in the dipole-octupole pyrochlore Ce 2 Zr 2 O 7

The pyrochlore magnet Ce 2 Zr 2 O 7 has attracted much attention as a quantum spin ice candidate whose novelty derives in part from the dipolar-octupolar nature of the Ce 3+ pseudospin-1/2 degrees of freedom it possesses. We report heat capacity measurements on single crystal samples of Ce 2 Zr 2 O 7 down to T~0.1K in a magnetic field along the [$1,\bar{1},0$] direction. These measurements show that the broad hump in the zero-field heat capacity moves higher in temperature with increasing field strength and is split into two separate humps by the [$1,\bar{1},0$] magnetic field at ~2T. These separate features are due to the decomposition of the pyrochlore lattice into effectively decoupled chains for fields in this direction: One set of chains (α chains) is polarized by the field while the other (β chains) remains free. This situation is similar to that observed in the classical spin ices Ho 2 Ti 2 O 7 and Dy 2 Ti 2 O 7 , but with the twist that here the strong transverse exchange interactions produce substantial quantum effects. Our theoretical modeling suggests that the β chains are close to a critical state, with nearly-gapless excitations. We also report elastic and inelastic neutron scattering measurements on single crystal Ce 2 Zr 2 O 7 in [$1,\bar{1},0$] and [0,0,1] magnetic fields at temperatures down to T=0.03K. The elastic scattering behaves consistently with the formation of independent chains for a [$1,\bar{1},0$] field, while the [0,0,1] field produces a single field-induced elastic magnetic Bragg peak at (0,2,0) and equivalent wavevectors, indicating a polarized spin ice state for fields above ~3T. For both [$1,\bar{1},0$] and [0,0,1] magnetic fields, our inelastic neutron scattering results show an approximately dispersionless continuum of scattering that increases in both energy and intensity with increasing field strength. By modeling the complete set of experimental data using numerical linked cluster and semiclassical molecular dynamics calculations, we demonstrate the dominantly multipolar nature of the exchange interactions in Ce 2 Zr 2 O 7 and the smallness of the parameter θ, which controls the mixing between dipolar and octupolar degrees of freedom. Finally, these results support previous estimates of the microscopic exchange parameters and place strong constraints on the theoretical description of this prominent spin ice candidate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Commissioning a small-field biological irradiator using point, 2D, and 3D dosimetry techniques

Purpose: To commission a small-field biological irradiator, the XRad225Cx from Precision x-Ray, Inc., for research use. The system produces a 225 kVp x-ray beam and is equipped with collimating cones that produce both square and circular radiation fields ranging in size from 1 to 40 mm. This work incorporates point, 2D, and 3D measurements to determine output factors (OF), percent-depth-dose (PDD) and dose profiles at multiple depths. Methods: Three independent dosimetry systems were used: ion-chambers (a farmer chamber and a micro-ionisation chamber), 2D EBT2 radiochromic film, and a novel 3D dosimetry system (DLOS/PRESAGE registered ). Reference point dose rates and output factors were determined from in-air ionization chamber measurements for fields down to {approx}13 mm using the formalism of TG61. PDD, profiles, and output factors at three separate depths (0, 0.5, and 2 cm), were determined for all field sizes from EBT2 film measurements in solid water. Several film PDD curves required a scaling correction, reflecting the challenge of accurate film alignment in very small fields. PDDs, profiles, and output factors were also determined with the 3D DLOS/PRESAGE registered system which generated isotropic 0.2 mm data, in scan times of 20 min. Results: Surface output factors determined by ion-chamber were observed to gradually drop by {approx}9% when the field size was reduced from 40 to 13 mm. More dramatic drops were observed for the smallest fields as determined by EBT{approx}18% and {approx}42% for the 2.5 mm and 1 mm fields, respectively. PRESAGE registered and film output factors agreed well for fields <20 mm (where 3D data were available) with mean deviation of 2.2% (range 1%-4%). PDD values at 2 cm depth varied from {approx}72% for the 40 mm field, down to {approx}55% for the 1 mm field. EBT and PRESAGE registered PDDs agreed within {approx}3% in the typical therapy region (1-4 cm). At deeper depths the EBT curves were slightly steeper (2.5% at 5 cm). These results indicate good overall consistency between ion-chamber, EBT2 and PRESAGE registered measured OFs, PDDs, and profiles. Conclusions: The combination of independent 2D and 3D measurements was found to be valuable to ensure accurate and comprehensive commissioning. Film measurements were time consuming and challenging due to the difficulty of film alignment in small fields. PRESAGE registered 3D measurements were comprehensive and efficient, because alignment errors are negligible, and all parameters for multiple fields could be obtained from a single dosimeter and scan. However, achieving accurate superficial data (within 4 mm) is not yet feasible due to optical surface artifacts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The use of computed radiography plates to determine light and radiation field coincidence

Purpose: Photo-stimulable phosphor computed radiography (CR) has characteristics that allow the output to be manipulated by both radiation and optical light. The authors have developed a method that uses these characteristics to carry out radiation field and light field coincidence quality assurance on linear accelerators.Methods: CR detectors from Kodak were used outside their cassettes to measure both radiation and light field edges from a Varian linear accelerator. The CR detector was first exposed to a radiation field and then to a slightly smaller light field. The light impinged on the detector's latent image, removing to an extent the portion exposed to the light field. The detector was then digitally scanned. A MATLAB-based algorithm was developed to automatically analyze the images and determine the edges of the light and radiation fields, the vector between the field centers, and the crosshair center. Radiographic film was also used as a control to confirm the radiation field size.Results: Analysis showed a high degree of repeatability with the proposed method. Results between the proposed method and radiographic film showed excellent agreement of the radiation field. The effect of varying monitor units and light exposure time was tested and found to be very small. Radiation and light field sizes were determined with an uncertainty of less than 1 mm, and light and crosshair centers were determined within 0.1 mm.Conclusions: A new method was developed to digitally determine the radiation and light field size using CR photo-stimulable phosphor plates. The method is quick and reproducible, allowing for the streamlined and robust assessment of light and radiation field coincidence, with no observer interpretation needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-D-BRD-02: In Memoriam of Bengt Bjarngard: SBRT II: Small Field Dosimetry - TG155

Specialized radiation treatment such as SRS/SRT. SBRT, IMRT, VMAT, Tomotherapy, CyberKnife and Gamma Knife use small fields or combination of small fields where dosimetry is challenging and uncertain due to non-equilibrium conditions such as longitudinal and lateral disequilibrium. Additionally the primary photon fluence is greatly affected by the obstruction of the source size by the jaws creating a large dose gradient across the field. Electronic equilibrium is a phenomenon associated with the range of secondary particles which depend on the beam energy, photon spectrum and the composition of the medium. Additionally, the finite size of detectors creates volume averaging and fluence perturbations especially in small fields. The IAEA/AAPM has provided a frame work for non-compliant reference dosimetry in small fields1. The AAPM TG-1552 has adopted this frame work to provide guidelines in relative dosimetry. This course provides the insight of TG-155 that defines small field, provides recommendations for suitable detectors and associated correction factors to convert reading to dose. Recommendations of a good working practice for relative dosimetry measurements (PDD, TMR, output factor, etc.) and dose calculations based on the new formulation is are elaborated. It also discusses beam modeling and dose calculations as a critical step in clinical utilization of small field radiotherapy. Small errors in beam data, approximations in dose algorithms, or misaligned of detectors and field settings can propagate into large errors in planned and delivered dose. The modeling and treatment planning aspects of small field dosimetry are reviewed with emphasis on the most critical parts for ensuring accurate and safe radiation therapy. Discussion on k(fmsr, fclin) for commercially available detectors are also provided.1 P. Alfonso, P. Andreo, R. Capote, M. S. Huq, W. Kilby, P. Kjall, T. R. Mackie, H. Palmans, K. Rosser, J. Seuntjens, W. Ullrich and S. Vatnitsky, “A new formalism for reference dosimetry of small and nonstandard fields,” Med Phys 35, 5179–5186 (2008).2 I. J. Das, P. Francescon, A. Ahnesjo, M. M. Aspradakis, C. W. Cheng, G. X. Ding, G. S. Ibbott, M. Oldham, M. S. Huq, C. S. Reft and S. O.A., “Task Group 155 report: Small fields and non-equilibrium condition photon beam dosimetry,” Med Phys (under review). Learning Objectives: Physics of cavity theory for non-equilibrium condition and definition of small fields Description of absolute and relative dosimetry in the context of TG-155 Choice of detector in small field dosimetry, perturbations and corrections (K(fmsr, fclin)) for accurate dosimetry Understand the advantages and limitations of commercially available detectors for small field dosimetry.

60 APPLIED LIFE SCIENCES↗