Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error localization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

CALIBRATING THE STAR FORMATION RATE AT z {approx} 1 FROM OPTICAL DATA

We present a star formation rate (SFR) calibration based on optical data that is consistent with average observed rates in both the red and blue galaxy populations at z {approx} 1. The motivation for this study is to calculate SFRs for DEEP2 Redshift Survey galaxies in the 0.7 < z < 1.4 redshift range, but our results are generally applicable to similar optically selected galaxy samples without requiring UV or IR data. Using SFR fits from UV/optical spectral energy distributions (SEDs) in the All-Wavelength Extended Groth Strip International Survey, we explore the behavior of rest-frame B-band magnitude, observed [O II] luminosity, and rest-frame color with SED-fit SFR for both red sequence and blue cloud galaxies. The resulting SFR calibration is based on three optical-band observables: M{sub B} , (U - B), and (B - V). The best-fit linear relation produces residual errors of 0.3 dex rms scatter for the full color-independent sample with minimal correlated residual error in L[O II] or stellar mass. We then compare the calibrated z {approx} 1 SFRs to two diagnostics that use L[O II] as a tracer in local galaxies and correct for dust extinction at intermediate redshifts through either galaxy B-band luminosity or stellar mass. We find that an L[O II]-M{sub B} SFR calibration commonly used in the literature agrees well with our calculated SFRs after correcting for the average B-band luminosity evolution in L{sub *} galaxies. However, we find better agreement with a local L[O II]-based SFR calibration that includes stellar mass to correct for reddening effects, indicating that stellar mass is a better tracer of dust extinction for all galaxy types and less affected by systematic evolution than galaxy luminosity from z = 1 to the current epoch.

79 ASTRONOMY AND ASTROPHYSICS↗

IMFIT: A FAST, FLEXIBLE NEW PROGRAM FOR ASTRONOMICAL IMAGE FITTING

I describe a new, open-source astronomical image-fitting program called IMFIT, specialized for galaxies but potentially useful for other sources, which is fast, flexible, and highly extensible. A key characteristic of the program is an object-oriented design that allows new types of image components (two-dimensional surface-brightness functions) to be easily written and added to the program. Image functions provided with IMFIT include the usual suspects for galaxy decompositions (Sérsic, exponential, Gaussian), along with Core-Sérsic and broken-exponential profiles, elliptical rings, and three components that perform line-of-sight integration through three-dimensional luminosity-density models of disks and rings seen at arbitrary inclinations. Available minimization algorithms include Levenberg-Marquardt, Nelder-Mead simplex, and Differential Evolution, allowing trade-offs between speed and decreased sensitivity to local minima in the fit landscape. Minimization can be done using the standard χ{sup 2} statistic (using either data or model values to estimate per-pixel Gaussian errors, or else user-supplied error images) or Poisson-based maximum-likelihood statistics; the latter approach is particularly appropriate for cases of Poisson data in the low-count regime. I show that fitting low-signal-to-noise ratio galaxy images using χ{sup 2} minimization and individual-pixel Gaussian uncertainties can lead to significant biases in fitted parameter values, which are avoided if a Poisson-based statistic is used; this is true even when Gaussian read noise is present.

79 ASTRONOMY AND ASTROPHYSICS↗

SpaceNet 9—Cross-Sensor Alignment of Optical and SAR Imagery

Precise registration of high-resolution synthetic aperture radar (SAR) and optical imagery is necessary for realizing the full potential and benefits of multimodal image analysis. However, two significant challenges presently exist. First, there is a lack of annotated datasets and benchmarks available for high-resolution SAR–optical image registration. Second, an assessment of efficient and reliable image registration methods that can precisely align these modalities is lacking. Here, we present a holistic description of the SpaceNet 9 Challenge and its results. We present a description of the dataset and baseline algorithm along with the results of the challenge, including a description of the winning algorithms. We release the SpaceNet 9 dataset along with open-sourcing the winning algorithms and baseline. The objective of SpaceNet 9 was to compute a dense displacement map that indicates the shift needed to align pixels in an optical image to the pixels in a SAR image. The challenge launched in April 2025 and was active for approximately two months. The top five solutions reduced image alignment error from approximately 34 m to under 13 m for public and private test data, with the best results obtaining a registration error of only 8.5 and 6.7 m on the public testing and private testing dataset, respectively. Usage of pretrained image matching models, robust outlier rejection with RANSAC, and estimating local displacement were common among the top solutions. The results of this challenge provide insight into high-resolution SAR–optical image registration and offer opportunities for future benchmarking in this domain. The baseline algorithm, winning solutions, and datasets are available at https://spacenet.ai/sn9-challenge/.

benchmark datasets↗

Target tracking using DMLC for volumetric modulated arc therapy: A simulation study

Purpose: Target tracking using dynamic multileaf collimator (DMLC) is a promising approach for intrafraction motion management in radiation therapy. The purpose of this work is to develop a DMLC tracking algorithm capable of delivering volumetric-modulated arc therapy (VMAT) to the targets that experience two-dimensional (2D) rigid motion in the beam's eye view. Methods: The problem of VMAT delivery to moving targets is formulated as a control problem with constraints. The relationships between gantry speed, gantry acceleration, MLC leaf-velocity, dose rate, and target motion are derived. An iterative search algorithm is developed to find numerical solutions for efficient delivery of a specific VMAT plan to the moving target using 2D DMLC tracking. The delivery of five VMAT lung plans is simulated. The planned and delivered fluence maps in the target-reference frame are calculated and compared. Results: The simulation demonstrates that the 2D tracking algorithm is capable of delivering the VMAT plan to a moving target fast and accurately without violating the machine constraints and the integrity of the treatment plan. The average delivery time is only 29 s longer than that of no-tracking delivery, 101 versus 72 s, respectively. The fluence maps are normalized to 200 MU and the average root-mean-square error between the desired and the delivered fluence is 2.1 MU, compared to 14.8 MU for no-tracking and 3.6 MU for one-dimensional tracking. Conclusions: A locally optimal MLC tracking algorithm for VMAT delivery is proposed, aiming at shortest delivery time while maintaining treatment plan invariant. The inconsequential increase of treatment time due to DMLC tracking is clinically desirable, which makes VMAT with DMLC tracking attractive in treating moving tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Critical issues in conducting constant strain rate nanoindentation tests at higher strain rates

Constant strain rate nanoindentation is a popular technique for probing the local mechanical properties of materials but is usually restricted to strain rates ≤0.1 s -1 . Faster indentation potentially results in an overestimation of the hardness because of the plasticity error associated with the continuous stiffness measurement (CSM) method. This can have significant consequences in some applications, such as the measurement of strain rate sensitivity. The experimental strain rate range can be extended by increasing the harmonic frequency of the CSM oscillation. However, with commercial instruments, this is achievable only by identifying higher CSM frequencies at which the testing system is dynamically well behaved. Using these principles, a commercial system operated at the unusually high harmonic frequency of 1570 Hz was successfully used to characterize of the strain rate sensitivity of a Zn22Al superplastic alloy at strain rates up to 1 s -1 , i.e., an order of magnitude higher than with standard methods.

36 MATERIALS SCIENCE↗

TOPEX orbit determination by solving gravity parameters with multiple arc data

Multiple arc data from repeated ground track are combined to reduce the error due to gravity field uncertainty in the determination of TOPEX orbit. The TOPEX dynamics is modeled with relatively few gravity parameters to account for the effect of the local gravity field. The gravity parameters are common to all arcs. The estimation algorithm uses the Householder transformation to combine multiple arc data and solve for the gravity parameters. The earth gravity field can be recovered with very modest amount of calculation.

Wu, J.-T.↗

Orbit and sampling requirements: TRMM experience

The Tropical Rainfall Measuring Mission (TRMM) concept originated in 1984. Its overall goal is to produce datasets that can be used in the improvement of general circulation models. A primary objective is a multi-year data stream of monthly averages of rain rate over 500 km boxes over the tropical oceans. Vertical distributions of the hydrometers, related to latent heat profiles, and the diurnal cycle of rainrates are secondary products believed to be accessible. The mission is sponsored jointly by the U.S. and Japan. TRMM is an approved mission with launch set for 1997. There are many retrieval and ground truth issues still being studied for TRMM, but here we concentrate on sampling since it is the single largest term in the error budget. The TRMM orbit plane is inclined by 35 degrees to the equator, which leads to a precession of the visits to a given grid box through the local hours of the day, requiring three to six weeks to complete the diurnal cycle, depending on latitude. For sampling studies we can consider the swath width to be about 700 km.

North, Gerald↗

Revised estimates of NO 2 reductions during the COVID-19 lockdowns using updated TROPOMI NO 2 retrievals and model simulations

The TROPOspheric Monitoring Instrument (TROPOMI) observed unprecedented declines in NO 2 vertical column densities (VCD) over the world's most densely populated cities during the 2020 COVID-19 lockdowns. These favorable changes in NO 2 air quality were correlated with sharp reductions in traffic volume and economic activity during the lockdowns. In this comprehensive global study, we provide revised estimates of the declines in anthropogenic emissions for 36 megacities using a novel methodology for disentangling the anthropogenic emissions from the meteorological transport and natural variability. We further quantify the uncertainty associated with changes in the a priori profile shape information during the lockdowns due to reduced emissions. Satellite NO 2 retrieval techniques calculate an air mass factor that requires a priori NO 2 profile shape information representative of the local atmosphere. This information, which is typically obtained from a chemical transport model (CTM), was not available for the early studies. This study also accounts for the satellite sampling errors resulting from the selective sampling of non-cloudy scenes during the study period. For our analysis, we used CTM simulations that were generated with and without COVID-impacted emissions. We perform retrievals of tropospheric NO 2 columns with the NASA NO 2 algorithm, and then use observed and simulated data to disentangle the meteorological transport from the contribution due anthropogenic emissions. We found that the meteorological transport was most significant source of variability ranging between −35% and 22% of the change total tropospheric VCD. We also find that not accounting for changes in the a priori NO 2 profile shape information during the lockdowns resulted in systematic retrieval errors that were up to 12% of the estimated decline, and the elimination of cloud contaminated scenes resulted in sampling errors that in general ranged between varied ±15%.

NO2↗

Ionospheric calibration for single frequency altimeter measurements

This report investigates the potential of using Global Positioning System (GPS) data and a model of the ionosphere to supply a measure of the sub-satellite Total Electron Current (TEC) of the required accuracy (10 TECU rms) for the purpose of calibrating single frequency radar altimeter measurements. Since climatological (monthly mean) models are known to be in error by as much as 50 percent, this work focused on the Parameterized Real-Time Ionospheric Specification Model (PRISM) which has the capability to improve model accuracy by ingesting (adjusting to) in situ ionospheric measurements. A set of globally distributed TEC measurements were generated using GPS data and were used as input to improve the accuracy of the PRISM model. The adjusted PRISM TEC values were compared to TOPEX dual frequency TEC measurements (which are considered truth) for a number of TOPEX sub-satellite tracks. The adjusted PRISM values generally compared to the TOPEX measurements within the 10 TECU accuracy requirements when the sub-satellite track passed within 300 to 400 km of the GPS TEC data or when the track passed through a night time ionosphere. However, when the sub-satellite points were greater than 300 to 400 km away from the GPS TEC data or when a local noon ionosphere was sampled, the adjusted PRISM values generally differed by greater than 10 TECU rms with data excursions from the TOPEX TEC measurements of as much as 40 TECU (an 8 cm path delay error at K band). Therefore, it can be concluded from this analysis that an unrealistically large number of GPS stations would be needed to predict sub-satellite TEC at the 10 TECU level in the day time ionosphere using a model such as PRISM. However, a technique currently being studied at the Jet Propulsion Laboratory (JPL) may provide a means of supplying adequate TEC data to meet the 10 TECU ionospheric correction accuracy when using a realistic number of ionospheric stations. This method involves using global GPS TEC data to estimate a global grid of vertical ionospheric TEC as a function of time (i.e. every one half hour) in a sun-fixed longitude frame. Working in a sun-fixed longitude frame, one is not limited by the spatial decorrelation distance of the ionosphere, but instead is limited more by the temporal correlations of the ionosphere in the sun-fixed frame which are a smaller effect. It is the opinion of the authors that using the global sun-fixed TEC grid data, in particular, ingesting it into PRISM, offers the best possibility of meeting the 10 TECU ionospheric correction accuracy requirement, and should be the subject of further study.

Schreiner, William S.↗

WHAT IS THE MOST PROMISING ELECTROMAGNETIC COUNTERPART OF A NEUTRON STAR BINARY MERGER?

The final inspiral of double neutron star and neutron-star-black-hole binaries are likely to be detected by advanced networks of ground-based gravitational wave (GW) interferometers. Maximizing the science returns from such a discovery will require the identification of an electromagnetic counterpart. Here we critically evaluate and compare several possible counterparts, including short-duration gamma-ray bursts (SGRBs), 'orphan' optical and radio afterglows, and day-long optical transients powered by the radioactive decay of heavy nuclei synthesized in the merger ejecta ('kilonovae'). We assess the promise of each counterpart in terms of four 'Cardinal Virtues': detectability, high fraction, identifiability, and positional accuracy. Taking into account the search strategy for typical error regions of tens of square degrees, we conclude that SGRBs are the most useful to confirm the cosmic origin of a few GW events, and to test the association with neutron star mergers. However, for the more ambitious goal of localizing and obtaining redshifts for a large sample of GW events, kilonovae are instead preferred. Off-axis optical afterglows are detectable for at most tens of percent of events, while radio afterglows are promising only for energetic relativistic ejecta in a high-density medium. Our main recommendations are: (1) an all-sky gamma-ray satellite is essential for temporal coincidence detections, and for GW searches of gamma-ray-triggered events; (2) the Large Synoptic Survey Telescope should adopt a one-day cadence follow-up strategy, ideally with 0.5 hr per pointing to cover GW error regions; and (3) radio searches should focus on the relativistic case, which requires observations for a few months.

79 ASTRONOMY AND ASTROPHYSICS↗

Chemoradiation With Concomitant Boosts Followed by Radical Surgery in Locally Advanced Cervical Cancer: Long-term Results of the ROMA-2 Prospective Phase 2 Study

Purpose: This prospective, phase 2 study aimed at assessing the efficacy of accelerated fractionation radiation therapy by concomitant boosts (CBs) associated with chemoradiation therapy (CRT) of the whole pelvis, in improving the rate of pathological complete response (pCR) to treatment in patients with International Federation of Gynaecology and Obstetrics (FIGO) stage IB2-IVA locally advanced cervical cancer. Methods and Materials: Neoadjuvant CRT included conformal irradiation of the whole pelvis with a total dose of 39.6 Gy (1.8 cGy/fraction, 22 fractions), plus additional irradiation of primary tumor and parametria with 10.8 Gy administered with CBs (0.9 cGy/fraction, 12 fractions, every other day). Concomitant chemotherapy included cisplatin (20 mg/m{sup 2}, days 1-4 and 26-30 of treatment), and capecitabine (1300 mg/m{sup 2}/daily, orally) during the first 2 and the last 2 weeks of treatment. Radical hysterectomy plus pelvic with or without aortic lymphadenectomy was performed within 6 to 8 weeks from CRT. Toxicity was recorded according to Radiation Therapy Oncology Group toxicity criteria and Chassagne grading system. Based on the Simon design, 103 cases were required, and the regimen would be considered active if >45 pCR were registered (α error = 0.05; β error = 0.1). Results: pCR was documented in 51 cases (50.5%), and the regimen was considered active, according to the planned statistical assumptions. At median follow-up of 36 months (range: 7-85 months), the 3-year local failure rate was 7%, whereas the 3-year disease-free and overall survival rates were 73.0% and 86.1%, respectively. Grade 3 leukopenia and neutropenia were reported in only 1 and 2 cases, respectively. Gastrointestinal toxicity was always grade 1 or 2. Conclusions: Addition of CBs in the accelerated fractionation modality to the whole pelvis chemoradiation followed by radical surgery results in a high rate of pathologically assessed complete response to CRT and a very encouraging local control rate, with acceptable toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatially resolved X-ray emission measurements of the residual velocity during the stagnation phase of inertial confinement fusion implosion experiments

A technique for measuring residual motion during the stagnation phase of an indirectly driven inertial confinement experiment has been implemented. This method infers a velocity from spatially and temporally resolved images of the X-ray emission from two orthogonal lines of sight. This work investigates the accuracy of recovering spatially resolved velocities from the X-ray emission data. A detailed analytical and numerical modeling of the X-ray emission measurement shows that the accuracy of this method increases as the displacement that results from a residual velocity increase. For the typical experimental configuration, signal-to-noise ratios, and duration of X-ray emission, it is estimated that the fractional error in the inferred velocity rises above 50% as the velocity of emission falls below 24 μm/ns. By inputting measured parameters into this model, error estimates of the residual velocity as inferred from the X-ray emission measurements are now able to be generated for experimental data. Details of this analysis are presented for an implosion experiment conducted with an unintentional radiation flux asymmetry. The analysis shows a bright localized region of emission that moves through the larger emitting volume at a relatively higher velocity towards the location of the imposed flux deficit. This technique allows for the possibility of spatially resolving velocity flows within the so-called central hot spot of an implosion. This information would help to refine our interpretation of the thermal temperature inferred from the neutron time of flight detectors and the effect of localized hydrodynamic instabilities during the stagnation phase. Across several experiments, along a single line of sight, the average difference in magnitude and direction of the measured residual velocity as inferred from the X-ray and neutron time of flight detectors was found to be ∼13 μm/ns and ∼14°, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Utilizing Adjoint-Based Error Estimates for Surrogate Models to Accurately Predict Probabilities of Events

In thist study, we develop a procedure to utilize error estimates for samples of a surrogate model to compute robust upper and lower bounds on estimates of probabilities of events. We show that these error estimates can also be used in an adaptive algorithm to simultaneously reduce the computational cost and increase the accuracy in estimating probabilities of events using computationally expensive high-fidelity models. Specifically, we introduce the notion of reliability of a sample of a surrogate model, and we prove that utilizing the surrogate model for the reliable samples and the high-fidelity model for the unreliable samples gives precisely the same estimate of the probability of the output event as would be obtained by evaluation of the original model for each sample. The adaptive algorithm uses the additional evaluations of the high-fidelity model for the unreliable samples to locally improve the surrogate model near the limit state, which significantly reduces the number of high-fidelity model evaluations as the limit state is resolved. Numerical results based on a recently developed adjoint-based approach for estimating the error in samples of a surrogate are provided to demonstrate (1) the robustness of the bounds on the probability of an event, and (2) that the adaptive enhancement algorithm provides a more accurate estimate of the probability of the QoI event than standard response surface approximation methods at a lower computational cost.

97 MATHEMATICS AND COMPUTING↗

An approximate Kalman filter for ocean data assimilation: An example with an idealized Gulf Stream model

A practical method of data assimilation for use with large, nonlinear, ocean general circulation models is explored. A Kalman filter based on approximation of the state error covariance matrix is presented, employing a reduction of the effective model dimension, the error's asymptotic steady state limit, and a time-invariant linearization of the dynamic model for the error integration. The approximations lead to dramatic computational savings in applying estimation theory to large complex systems. We examine the utility of the approximate filter in assimilating different measurement types using a twin experiment of an idealized Gulf Stream. A nonlinear primitive equation model of an unstable east-west jet is studied with a state dimension exceeding 170,000 elements. Assimilation of various pseudomeasurements are examined, including velocity, density, and volume transport at localized arrays and realistic distributions of satellite altimetry and acoustic tomography observations. Results are compared in terms of their effects on the accuracies of the estimation. The approximate filter is shown to outperform an empirical nudging scheme used in a previous study. The examples demonstrate that useful approximate estimation errors can be computed in a practical manner for general circulation models.

Fukumori, Ichiro↗

FERMI LAT OBSERVATION OF DIFFUSE GAMMA RAYS PRODUCED THROUGH INTERACTIONS BETWEEN LOCAL INTERSTELLAR MATTER AND HIGH-ENERGY COSMIC RAYS

Observations by the Large Area Telescope (LAT) on the Fermi mission of diffuse gamma-rays in a mid-latitude region in the third quadrant (Galactic longitude l from 200 deg. to 260 deg. and latitude |b| from 22 deg. to 60 deg.) are reported. The region contains no known large molecular cloud and most of the atomic hydrogen is within 1 kpc of the solar system. The contributions of gamma-ray point sources and inverse Compton scattering are estimated and subtracted. The residual gamma-ray intensity exhibits a linear correlation with the atomic gas column density in energy from 100 MeV to 10 GeV. The measured integrated gamma-ray emissivity is (1.63 +- 0.05) x 10{sup -26} photons s{sup -1}sr{sup -1} H-atom{sup -1} and (0.66 +- 0.02) x 10{sup -26} photons s{sup -1}sr{sup -1} H-atom{sup -1} above 100 MeV and above 300 MeV, respectively, with an additional systematic error of {approx}10%. The differential emissivity from 100 MeV to 10 GeV agrees with calculations based on cosmic ray spectra consistent with those directly measured, at the 10% level. The results obtained indicate that cosmic ray nuclei spectra within 1 kpc from the solar system in regions studied are close to the local interstellar spectra inferred from direct measurements at the Earth within {approx}10%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An Approximate Kalman Filter for Ocean Data Assimilation; An Example with an Idealized Gulf Stream Model

A practical method of data assimilation for use with large, nonlinear, ocean general circulation models is explored. A Kalman filter based on approximations of the state error covariance matrix is presented, employing a reduction of the effective model dimension, the error's asymptotic steady-state limit, and a time-invariant linearization of the dynamic model for the error integration. The approximations lead to dramatic computational savings in applying estimation theory to large complex systems. We examine the utility of the approximate filter in assimilating different measurement types using a twin experiment of an idealized Gulf Stream. A nonlinear primitive equation model of an unstable east-west jet is studied with a state dimension exceeding 170,000 elements. Assimilation of various pseudo measurements is examined, including velocity, density, and volume transport at localized arrays, and realistic distributions of satellite altimetry and acoustic tomography observations. Results are compared in terms of their effects on the accuracies of the estimation. The approximate filter is shown to outperform a previous study that used an empirical nudging scheme. The examples demonstrate that useful approximate estimation errors can be computed in a practical manner for general circulation models.

['Kalman↗

Generic method for automatic bladder segmentation on cone beam CT using a patient-specific bladder shape model

Purpose: The aim of this study is to develop and validate a generic method for automatic bladder segmentation on cone beam computed tomography (CBCT), independent of gender and treatment position (prone or supine), using only pretreatment imaging data. Methods: Data of 20 patients, treated for tumors in the pelvic region with the entire bladder visible on CT and CBCT, were divided into four equally sized groups based on gender and treatment position. The full and empty bladder contour, that can be acquired with pretreatment CT imaging, were used to generate a patient-specific bladder shape model. This model was used to guide the segmentation process on CBCT. To obtain the bladder segmentation, the reference bladder contour was deformed iteratively by maximizing the cross-correlation between directional grey value gradients over the reference and CBCT bladder edge. To overcome incorrect segmentations caused by CBCT image artifacts, automatic adaptations were implemented. Moreover, locally incorrect segmentations could be adapted manually. After each adapted segmentation, the bladder shape model was expanded and new shape patterns were calculated for following segmentations. All available CBCTs were used to validate the segmentation algorithm. The bladder segmentations were validated by comparison with the manual delineations and the segmentation performance was quantified using the Dice similarity coefficient (DSC), surface distance error (SDE) and SD of contour-to-contour distances. Also, bladder volumes obtained by manual delineations and segmentations were compared using a Bland-Altman error analysis. Results: The mean DSC, mean SDE, and mean SD of contour-to-contour distances between segmentations and manual delineations were 0.87, 0.27 cm and 0.22 cm (female, prone), 0.85, 0.28 cm and 0.22 cm (female, supine), 0.89, 0.21 cm and 0.17 cm (male, supine) and 0.88, 0.23 cm and 0.17 cm (male, prone), respectively. Manual local adaptations improved the segmentation results significantly (p < 0.01) based on DSC (6.72%) and SD of contour-to-contour distances (0.08 cm) and decreased the 95% confidence intervals of the bladder volume differences. Moreover, expanding the shape model improved the segmentation results significantly (p < 0.01) based on DSC and SD of contour-to-contour distances. Conclusions: This patient-specific shape model based automatic bladder segmentation method on CBCT is accurate and generic. Our segmentation method only needs two pretreatment imaging data sets as prior knowledge, is independent of patient gender and patient treatment position and has the possibility to manually adapt the segmentation locally.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Note: Rotaphone, a new self-calibrated six-degree-of-freedom seismic sensor

We have developed and tested (calibration, linearity, and cross-axis errors) a new six-degree-of-freedom mechanical seismic sensor for collocated measurements of three translational and three rotational ground motion velocity components. The device consists of standard geophones arranged in parallel pairs to detect spatial gradients. The instrument operates in a high-frequency range (above the natural frequency of the geophones, 4.5 Hz). Its theoretical sensitivity limit in this range is 10{sup -9} m/s in ground velocity and 10{sup -9} rad/s in rotation rate. Small size and weight, and easy installation and maintenance make the instrument useful for local-earthquake recording and seismic prospecting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗