Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error correction.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

SU-F-T-410: Investigation of Treatment Planning Accuracy with the Presence of Magnetic Injection Port (breast Tissue Expander)

Purpose: Mastectomy patients with breast reconstruction usually have a magnetic injection port inside the breast during radiation treatments. The magnet has a very high CT number and produces severe streaking artifact across the entire breast in CT images. Our routine strategy is to replace the artifact volumes with uniform water, and it is necessary to validate that the planned dose, with such an artifact correction, is sufficiently accurate. Methods: A phantom was made with a gelatine-filled container sitting on a Matrixx detector, and the magnetic port was inserted into gelatine with specific depths and orientations. The phantom was scanned on a CT simulator and imported into Eclipse for treatment planning. The dose distribution at the Matrixx detector plane was calculated for raw CT images and artifact-corrected images. The treatment beams were then delivered to the phantom and the dose distributions were acquired by the Matrixx detector. Gamma index was calculated to compare the planned dose and the measurement. Results: Three field sizes (10×10, 15×15 and 20×20) and two depths (50mm and 20mm) were investigated. With the 2%/2mm or 3%/3mm criteria, several points (6–10) failed in the plan for raw CT images, and the number of failure was reduced close to zero for the corrected CT images. An assignment of 10,000 HU to the magnet further reduced the dose error directly under the magnet. Conclusion: It is validated that our routine strategy of artifact correction can effectively reduce the number of failures in the detector plane. It is also recommended to set the magnet with a CT number of 10,000HU, which could potentially improve the dose calculation at the points right behind the magnet.

60 APPLIED LIFE SCIENCES↗

SU-F-J-211: Scatter Correction for Clinical Cone-Beam CT System Using An Optimized Stationary Beam Blocker with a Single Scan

Purpose: X-ray scatter photons result in significant image quality degradation of cone-beam CT (CBCT). Measurement based algorithms using beam blocker directly acquire the scatter samples and achieve significant improvement on the quality of CBCT image. Within existing algorithms, single-scan and stationary beam blocker proposed previously is promising due to its simplicity and practicability. Although demonstrated effectively on tabletop system, the blocker fails to estimate the scatter distribution on clinical CBCT system mainly due to the gantry wobble. In addition, the uniform distributed blocker strips in our previous design results in primary data loss in the CBCT system and leads to the image artifacts due to data insufficiency. Methods: We investigate the motion behavior of the beam blocker in each projection and design an optimized non-uniform blocker strip distribution which accounts for the data insufficiency issue. An accurate scatter estimation is then achieved from the wobble modeling. Blocker wobble curve is estimated using threshold-based segmentation algorithms in each projection. In the blocker design optimization, the quality of final image is quantified using the number of the primary data loss voxels and the mesh adaptive direct search algorithm is applied to minimize the objective function. Scatter-corrected CT images are obtained using the optimized blocker. Results: The proposed method is evaluated using Catphan@504 phantom and a head patient. On the Catphan©504, our approach reduces the average CT number error from 115 Hounsfield unit (HU) to 11 HU in the selected regions of interest, and improves the image contrast by a factor of 1.45 in the high-contrast regions. On the head patient, the CT number error is reduced from 97 HU to 6 HU in the soft tissue region and image spatial non-uniformity is decreased from 27% to 5% after correction. Conclusion: The proposed optimized blocker design is practical and attractive for CBCT guided radiation therapy. This work is supported by grants from Guangdong Innovative Research Team Program of China (Grant No. 2011S013), National 863 Programs of China (Grant Nos. 2012AA02A604 and 2015AA043203), the National High-tech R&D Program for Young Scientists by the Ministry of Science and Technology of China (Grant No. 2015AA020917)

60 APPLIED LIFE SCIENCES↗

SU-F-T-245: The Investigation of Failure Mode and Effects Analysis and PDCA for the Radiotherapy Risk Reduction

Purpose: To optimize the clinical processes of radiotherapy and to reduce the radiotherapy risks by implementing the powerful risk management tools of failure mode and effects analysis(FMEA) and PDCA(plan-do-check-act). Methods: A multidiciplinary QA(Quality Assurance) team from our department consisting of oncologists, physicists, dosimetrists, therapists and administrator was established and an entire workflow QA process management using FMEA and PDCA tools was implemented for the whole treatment process. After the primary process tree was created, the failure modes and Risk priority numbers(RPNs) were determined by each member, and then the RPNs were averaged after team discussion. Results: 3 of 9 failure modes with RPN above 100 in the practice were identified in the first PDCA cycle, which were further analyzed to investigate the RPNs: including of patient registration error, prescription error and treating wrong patient. New process controls reduced the occurrence, or detectability scores from the top 3 failure modes. Two important corrective actions reduced the highest RPNs from 300 to 50, and the error rate of radiotherapy decreased remarkably. Conclusion: FMEA and PDCA are helpful in identifying potential problems in the radiotherapy process, which was proven to improve the safety, quality and efficiency of radiation therapy in our department. The implementation of the FMEA approach may improve the understanding of the overall process of radiotherapy while may identify potential flaws in the whole process. Further more, repeating the PDCA cycle can bring us closer to the goal: higher safety and accuracy radiotherapy.

60 APPLIED LIFE SCIENCES↗

Improving the Estimation of the Atmospheric Water Vapor Pressure Using Interpretable Long Short-Term Memory Networks: Dataset, Python code, and trained models

Atmospheric water vapor pressure is an essential meteorological control on land surface and hydrologic processes. It is not as frequently observed as other meteorologic conditions, but often inferred through the August–Roche–Magnus formula by simply assuming dew point and daily minimum temperatures are equivalent or by empirically correlating the two temperatures using an aridity correction. The performance of both methods varies considerably across different regions and during different time periods; obtaining consistently accurate estimates across space and time remains a great challenge. We applied an interpretable Long Short-Term Memory (iLSTM) network conditioned on static, location specific attributes to estimate daily vapor pressure for 83 FLUXNET sites in the United States and Canada. This data package includes all raw data of the 83 FLUXNET sites, input data for model training/validation/test, trained models and results, and python codes for the manuscript "Improving the Estimation of the Atmospheric Water Vapor Pressure Using an Interpretable Long Short-term Memory Network". Specifically, it consists of five parts. - First, "1_Daymet_data_83sites.zip" includes raw data downloaded from Daymet for the 83 sites used in the paper according to their longitude and latitude, in which vapor pressure is used. It also includes a pre-processed CSV data file combining all data from the 83 sites which is specifically used for the paper. - Second, "2_Fluxnet2015_data_83sites.zip" includes raw half hourly data of the 83 sites downloaded from FLUXNET2015 data portal, pre-processed daily data of the 83 sites, a CSV file including combined pre-processed daily data of the 83 sites, and a CSV file including the information (site ID, site name, latitude, longitude, data available period) of the 83 sites. - Third, "3_MODIS_LAI_data_83sites_raw.zip" includes raw leaf area index (LAI) data downloaded from the AppEEARs data portal. - Fourth, "4_Scripts.zip" includes all scripts related to model training and post-processing of a trained model, and a jupyter notebook showing an example for model post-processing. Two typo errors in files titled "run2get_args.py" and "postprocess.py" were corrected on March 27, 2024 to avoid confusions. - Finally, "Trained_models_and_results.zip" includes three folders and three files with suffix ".npy", and each folder corresponds to one file with suffix ".npy" with the same title. Each of the three folders include all trained models associated with one iLSTM model configuration (35 models for each configuration, details are described in the paper). Each file with suffix ".npy" includes the post-processed results of the corresponding 35 models under one iLSTM model configuration.

54 ENVIRONMENTAL SCIENCES↗

Author Correction: Building a global alliance of biofoundries

The original version of this Comment contained errors in the legend of Figure 2, in which the locations of the fifteenth and sixteenth GBA members were incorrectly given as '(15) Australian Genome Foundry, Macquarie University; (16) Australian Foundry for Advanced Biomanufacturing, University of Queensland'. The correct version replaces this with '(15) Australian Foundry for Advanced Biomanufacturing (AusFAB), University of Queensland and (16) Australian Genome Foundry, Macquarie University'. This has been corrected in both the PDF and HTML versions of the Comment.

59 BASIC BIOLOGICAL SCIENCES↗

Mass-preserving time second-order explicit–implicit domain decomposition schemes for solving parabolic equations with variable coefficients

In this paper, the new mass-preserving time second-order explicit–implicit domain decomposition (DD) schemes for solving parabolic equations with various coefficients are proposed. In the schemes, first, the interface values on the interfaces of sub-domains are explicitly calculated, in which two kinds of explicit difference schemes are used. Second, the interior values in sub-domains are determined by the implicit schemes. Third, the interface values are recalculated explicitly to preserve mass. The important feature is that the developed schemes are more than first order in time step and the correction operators at the third step ensure the schemes’ mass conservative. The stability and convergence are analyzed for the two schemes. The optimal error estimates are obtained in the H{sup 1} semi-norm under a stability condition. Numerical experiments confirm the theoretical results.

97 MATHEMATICS AND COMPUTING↗

Template-based automatic breast segmentation on MRI by excluding the chest region

Purpose: Methods for quantification of breast density on MRI using semiautomatic approaches are commonly used. In this study, the authors report on a fully automatic chest template-based method. Methods: Nonfat-suppressed breast MR images from 31 healthy women were analyzed. Among them, one case was randomly selected and used as the template, and the remaining 30 cases were used for testing. Unlike most model-based breast segmentation methods that use the breast region as the template, the chest body region on a middle slice was used as the template. Within the chest template, three body landmarks (thoracic spine and bilateral boundary of the pectoral muscle) were identified for performing the initial V-shape cut to determine the posterior lateral boundary of the breast. The chest template was mapped to each subject's image space to obtain a subject-specific chest model for exclusion. On the remaining image, the chest wall muscle was identified and excluded to obtain clean breast segmentation. The chest and muscle boundaries determined on the middle slice were used as the reference for the segmentation of adjacent slices, and the process continued superiorly and inferiorly until all 3D slices were segmented. The segmentation results were evaluated by an experienced radiologist to mark voxels that were wrongly included or excluded for error analysis. Results: The breast volumes measured by the proposed algorithm were very close to the radiologist's corrected volumes, showing a % difference ranging from 0.01% to 3.04% in 30 tested subjects with a mean of 0.86% ± 0.72%. The total error was calculated by adding the inclusion and the exclusion errors (so they did not cancel each other out), which ranged from 0.05% to 6.75% with a mean of 3.05% ± 1.93%. The fibroglandular tissue segmented within the breast region determined by the algorithm and the radiologist were also very close, showing a % difference ranging from 0.02% to 2.52% with a mean of 1.03% ± 1.03%. The total error by adding the inclusion and exclusion errors ranged from 0.16% to 11.8%, with a mean of 2.89% ± 2.55%. Conclusions: The automatic chest template-based breast MRI segmentation method worked well for cases with different body and breast shapes and different density patterns. Compared to the radiologist-established truth, the mean difference in segmented breast volume was approximately 1%, and the total error by considering the additive inclusion and exclusion errors was approximately 3%. This method may provide a reliable tool for MRI-based segmentation of breast density.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-AB-207A-02: John’s Equation Based Consistency Condition and Incomplete Projection Restoration Upon Circular Orbit CBCT

Purpose: In transmitted X-ray tomography imaging, projections are sometimes incomplete due to a variety of reasons, such as geometry inaccuracy, defective detector cells, etc. To address this issue, we have derived a direct consistency condition based on John’s Equation, and proposed a method to effectively restore incomplete projections based on this consistency condition. Methods: Through parameter substitutions, we have derived a direct consistency condition equation from John’s equation, in which the left side is only projection derivative of view and the right side is projection derivative of other geometrical parameters. Based on this consistency condition, a projection restoration method is proposed, which includes five steps: 1) Forward projecting reconstructed image and using linear interpolation to estimate the incomplete projections as the initial result; 2) Performing Fourier transform on the projections; 3) Restoring the incomplete frequency data using the consistency condition equation; 4) Performing inverse Fourier transform; 5) Repeat step 2)∼4) until our criteria is met to terminate the iteration. Results: A beam-blocking-based scatter correction case and a bad-pixel correction case were used to demonstrate the efficacy and robustness of our restoration method. The mean absolute error (MAE), signal noise ratio (SNR) and mean square error (MSE) were employed as our evaluation metrics of the reconstructed images. For the scatter correction case, the MAE is reduced from 63.3% to 71.7% with 4 iterations. Compared with the existing Patch’s method, the MAE of our method is further reduced by 8.72%. For the bad-pixel case, the SNR of the reconstructed image by our method is increased from 13.49% to 21.48%, with the MSE being decreased by 45.95%, compared with linear interpolation method. Conclusion: Our studies have demonstrated that our restoration method based on the new consistency condition could effectively restore the incomplete projections, especially for their high frequency component.

60 APPLIED LIFE SCIENCES↗

Optimization of the artificial viscosity in Lagrangian staggered discretization codes. Modeling 1D stand-alone shock - case study

We have developed new measures of errors for numerical shock. The new approach is based on analysis of the structure function, and separation of the errors related to oscillations and shock width, which also include error in the position of the ”center” of the numerical shock. We have demonstrated that those measures correctly characterize the numerical solution. We introduced an objective function in, which both types of errors are weighted, and presented optimal values of the coefficients of the linear and quadratic viscosity for different weights and different Mach numbers.

97 MATHEMATICS AND COMPUTING↗

Characterization of XR-RV3 GafChromic{sup ®} films in standard laboratory and in clinical conditions and means to evaluate uncertainties and reduce errors

Purpose: To investigate the optimal use of XR-RV3 GafChromic{sup ®} films to assess patient skin dose in interventional radiology while addressing the means to reduce uncertainties in dose assessment. Methods: XR-Type R GafChromic films have been shown to represent the most efficient and suitable solution to determine patient skin dose in interventional procedures. As film dosimetry can be associated with high uncertainty, this paper presents the EURADOS WG 12 initiative to carry out a comprehensive study of film characteristics with a multisite approach. The considered sources of uncertainties include scanner, film, and fitting-related errors. The work focused on studying film behavior with clinical high-dose-rate pulsed beams (previously unavailable in the literature) together with reference standard laboratory beams. Results: First, the performance analysis of six different scanner models has shown that scan uniformity perpendicular to the lamp motion axis and that long term stability are the main sources of scanner-related uncertainties. These could induce errors of up to 7% on the film readings unless regularly checked and corrected. Typically, scan uniformity correction matrices and reading normalization to the scanner-specific and daily background reading should be done. In addition, the analysis on multiple film batches has shown that XR-RV3 films have generally good uniformity within one batch (<1.5%), require 24 h to stabilize after the irradiation and their response is roughly independent of dose rate (<5%). However, XR-RV3 films showed large variations (up to 15%) with radiation quality both in standard laboratory and in clinical conditions. As such, and prior to conducting patient skin dose measurements, it is mandatory to choose the appropriate calibration beam quality depending on the characteristics of the x-ray systems that will be used clinically. In addition, yellow side film irradiations should be preferentially used since they showed a lower dependence on beam parameters compared to white side film irradiations. Finally, among the six different fit equations tested in this work, typically used third order polynomials and more rational and simplistic equations, of the form dose inversely proportional to pixel value, were both found to provide satisfactory results. Fitting-related uncertainty was clearly identified as a major contributor to the overall film dosimetry uncertainty with up to 40% error on the dose estimate. Conclusions: The overall uncertainty associated with the use of XR-RV3 films to determine skin dose in the interventional environment can realistically be estimated to be around 20% (k = 1). This uncertainty can be reduced to within 5% if carefully monitoring scanner, film, and fitting-related errors or it can easily increase to over 40% if minimal care is not taken. This work demonstrates the importance of appropriate calibration, reading, fitting, and other film-related and scan-related processes, which will help improve the accuracy of skin dose measurements in interventional procedures.

60 APPLIED LIFE SCIENCES↗

Describing long-range charge-separation processes with subsystem density-functional theory

Long-range charge-transfer processes in extended systems are difficult to describe with quantum chemical methods. In particular, cost-effective (non-hybrid) approximations within time-dependent density functional theory (DFT) are not applicable unless special precautions are taken. Here, we show that the efficient subsystem DFT can be employed as a constrained DFT variant to describe the energetics of long-range charge-separation processes. A formal analysis of the energy components in subsystem DFT for such excitation energies is presented, which demonstrates that both the distance dependence and the long-range limit are correctly described. In addition, electronic couplings for these processes as needed for rate constants in Marcus theory can be obtained from this method. It is shown that the electronic structure of charge-separated states constructed by a positively charged subsystem interacting with a negatively charged one is difficult to converge — charge leaking from the negative subsystem to the positive one can occur. This problem is related to the delocalization error in DFT and can be overcome with asymptotically correct exchange–correlation (XC) potentials or XC potentials including a sufficiently large amount of exact exchange. We also outline an approximate way to obtain charge-transfer couplings between locally excited and charge-separated states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Case report of a near medical event in stereotactic radiotherapy due to improper units of measure from a treatment planning system

Purpose: The authors hereby notify the Radiation Oncology community of a potentially lethal error due to improper implementation of linear units of measure in a treatment planning system. The authors report an incident in which a patient was nearly mistreated during a stereotactic radiotherapy procedure due to inappropriate reporting of stereotactic coordinates by the radiation therapy treatment planning system in units of centimeter rather than in millimeter. The authors suggest a method to detect such errors during treatment planning so they are caught and corrected prior to the patient positioning for treatment on the treatment machine. Methods: Using pretreatment imaging, the authors found that stereotactic coordinates are reported with improper linear units by a treatment planning system. The authors have implemented a redundant, independent method of stereotactic coordinate calculation. Results: Implementation of a double check of stereotactic coordinates via redundant, independent calculation is simple and accurate. Use of this technique will avoid any future error in stereotactic treatment coordinates due to improper linear units, transcription, or other similar errors. Conclusions: The authors recommend an independent double check of stereotactic treatment coordinates during the treatment planning process in order to avoid potential mistreatment of patients.

61 RADIATION PROTECTION AND DOSIMETRY↗

Maps and inverse maps in open quantum dynamics

Two kinds of maps that describe evolution of states of a subsystem coming from dynamics described by a unitary operator for a larger system, maps defined for fixed mean values and maps defined for fixed correlations, are found to be quite different for the same unitary dynamics in the same situation in the larger system. An affine form is used for both kinds of maps to find necessary and sufficient conditions for inverse maps. All the different maps with the same homogeneous part in their affine forms have inverses if and only if the homogeneous part does. Some of these maps are completely positive; others are not, but the homogeneous part is always completely positive. The conditions for an inverse are the same for maps that are not completely positive as for maps that are. For maps defined for fixed mean values, the homogeneous part depends only on the unitary operator for the dynamics of the larger system, not on any state or mean values or correlations. Necessary and sufficient conditions for an inverse are stated several different ways: in terms of the maps of matrices, basis matrices, density matrices, or mean values. The inverse maps are generally not tied to the dynamics the way the maps forward are. A trace-preserving completely positive map that is unital cannot have an inverse that is obtained from any dynamics described by any unitary operator for any states of a larger system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Review of analytical studies on seismic fluid-structure interaction of base-supported cylindrical tanks

Analytical solutions for seismic fluid-structure interaction (FSI) of tanks are used by analysts and engineers for a number of purposes, including preliminary sizing, risk assessment, and verification of numerical models. Analytical solutions for seismic FSI of tanks were first developed in the 1930s and have been extended and/or modified in the following nine decades to accommodate different seismic inputs and boundary conditions. This report reviews published analytical solutions for rigid and flexible, base-supported, cylindrical tanks subjected to unidirectional horizontal motion of a small amplitude. The studies parsed the fluid-structure (FSI) response into an impulsive and a convective component, and addressed frequencies of lateral motions of the tank (i.e., impulsive frequencies), hydrodynamic pressures, frequencies of waves (i.e., convective frequencies), wave heights, and reactions at the base. The solutions were categorized into exact and approximate solutions based on the methodologies used. Herein, FSI responses are calculated and compared for a range of tank dimensions using the analytical solutions from the different studies. The responses presented here are normalized to be unitless, and can be used for tanks with different dimensions and mechanical properties, and subjected to different input motions. A sample steel water tank is analyzed using the normalized solutions for two earthquake ground motions with different frequency contents. Ignoring tank flexibility may significantly underestimate seismic responses of the tank and its contained fluid. The approximate solutions, which have been widely used for decades, may not be sufficiently accurate in the modern era. Calculation errors in the reviewed studies are identified and corrected, and differences are quantified for the sample tank.

42 ENGINEERING↗

Cigarettes vs. e-cigarettes: Passive exposure at home measured by means of airborne marker and biomarkers

Background: There is scarce evidence about passive exposure to the vapour released or exhaled from electronic cigarettes (e-cigarettes) under real conditions. The aim of this study is to characterise passive exposure to nicotine from e-cigarettes' vapour and conventional cigarettes' smoke at home among non-smokers under real-use conditions. Methods: We conducted an observational study with 54 non-smoker volunteers from different homes: 25 living at home with conventional smokers, 5 living with nicotine e-cigarette users, and 24 from control homes (not using conventional cigarettes neither e-cigarettes). We measured airborne nicotine at home and biomarkers (cotinine in saliva and urine). We calculated geometric mean (GM) and geometric standard deviations (GSD). We also performed ANOVA and Student's t tests for the log-transformed data. We used Bonferroni-corrected t-tests to control the family error rate for multiple comparisons at 5%. Results: The GMs of airborne nicotine were 0.74 μg/m{sup 3} (GSD=4.05) in the smokers’ homes, 0.13 μg/m{sup 3} (GSD=2.4) in the e-cigarettes users’ homes, and 0.02 μg/m{sup 3} (GSD=3.51) in the control homes. The GMs of salivary cotinine were 0.38 ng/ml (GSD=2.34) in the smokers’ homes, 0.19 ng/ml (GSD=2.17) in the e-cigarettes users’ homes, and 0.07 ng/ml (GSD=1.79) in the control homes. Salivary cotinine concentrations of the non-smokers exposed to e-cigarette's vapour at home (all exposed ≥2 h/day) were statistically significant different that those found in non-smokers exposed to second-hand smoke ≥2 h/day and in non-smokers from control homes. Conclusions: The airborne markers were statistically higher in conventional cigarette homes than in e-cigarettes homes (5.7 times higher). However, concentrations of both biomarkers among non-smokers exposed to conventional cigarettes and e-cigarettes’ vapour were statistically similar (only 2 and 1.4 times higher, respectively). The levels of airborne nicotine and cotinine concentrations in the homes with e-cigarette users were higher than control homes (differences statistically significant). Our results show that non-smokers passively exposed to e-cigarettes absorb nicotine. - Highlights: • This is the first study of e-cigarette exposure at home under real-use conditions. • Airborne nicotine in homes with smokers were 5.7 times higher than in e-cig homes. • Cotinine of non-smokers exposed to e-cig and conventional cigarettes was similar. • Airborne nicotine in homes with e-cig users was higher than control homes. • Cotinine of non-smokers exposed to e-cig users was higher than in those no exposed.

54 ENVIRONMENTAL SCIENCES↗

Hydrogen measurement during steam oxidation using coupled thermogravimetric analysis and quadrupole mass spectrometry

An analytical technique is presented with the goal of measuring reaction kinetics during steam oxidation reactions for three cases in which obtaining kinetics information often requires a prohibitive amount of time and cost. The technique presented relies on coupling thermogravimetric analysis (TGA) with a quantitative hydrogen measurement technique using quadrupole mass spectrometry (QMS). The first case considered is in differentiating between the kinetics of steam oxidation reactions and those for simultaneously reacting gaseous impurities such as nitrogen or oxygen. The second case allows one to independently measure the kinetics of oxide and hydride formation for systems in which both of these reactions are known to take place during steam oxidation. The third case deals with measuring the kinetics of formation for competing volatile and non-volatile oxides during certain steam oxidation reactions. In order to meet the requirements of the coupled technique, a methodology is presented which attempts to provide quantitative measurement of hydrogen generation using QMS in the presence of an interfering fragmentation species, namely water vapor. This is achieved such that all calibrations and corrections are performed during the TGA baseline and steam oxidation programs, making system operation virtually identical to standard TGA. Benchmarking results showed a relative error in hydrogen measurement of 5.7–8.4% following the application of a correction factor. Lastly, suggestions are made for possible improvements to the presented technique so that it may be better applied to the three cases presented.

36 MATERIALS SCIENCE↗

Event-Based Processing of Neutron Scattering Data

Many of the world's time-of-flight spallation neutrons sources are migrating to the recording of individual neutron events. This provides for new opportunities in data processing, the least of which is to filter the events based on correlating them with logs of sample environment and other ancillary equipment. This paper will describe techniques for processing neutron scattering data acquired in event mode that preserve event information all the way to a final spectrum, including any necessary corrections or normalizations. This results in smaller final errors, while significantly reducing processing time and memory requirements in typical experiments. Results with traditional histogramming techniques will be shown for comparison.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗