Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Neutron detection using boron gallium nitride semiconductor material

In this study, we developed a new neutron-detection device using a boron gallium nitride (BGaN) semiconductor in which the B atom acts as a neutron converter. BGaN and gallium nitride (GaN) samples were grown by metal organic vapor phase epitaxy, and their radiation detection properties were evaluated. GaN exhibited good sensitivity to α-rays but poor sensitivity to γ-rays. Moreover, we confirmed that electrons were generated in the depletion layer under neutron irradiation. This resulted in a neutron-detection signal after α-rays were generated by the capture of neutrons by the B atoms. These results prove that BGaN is useful as a neutron-detecting semiconductor material.

36 MATERIALS SCIENCE↗

Effect of the wire width on the intrinsic detection efficiency of superconducting-nanowire single-photon detectors

A thorough spectral study of the intrinsic single-photon detection efficiency in superconducting TaN and NbN nanowires with different widths has been performed. The experiment shows that the cut-off of the intrinsic detection efficiency at near-infrared wavelengths is most likely controlled by the local suppression of the barrier for vortex nucleation around the absorption site. Beyond the cut-off quasi-particle diffusion in combination with spontaneous, thermally activated vortex crossing explains the detection process. For both materials, the reciprocal cut-off wavelength scales linearly with the wire width where the scaling factor agrees with the hot-spot detection model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrasensitive detection of Hg{sup 2+} using oligonucleotide-functionalized AlGaN/GaN high electron mobility transistor

An oligonucleotide-functionalized ion sensitive AlGaN/GaN high electron mobility transistor (HEMT) was fabricated to detect trace amounts of Hg{sup 2+}. The advantages of ion sensitive AlGaN/GaN HEMT and highly specific binding interaction between Hg{sup 2+} and thymines were combined. The current response of this Hg{sup 2+} ultrasensitive transistor was characterized. The current increased due to the accumulation of Hg{sup 2+} ions on the surface by the highly specific thymine-Hg{sup 2+}-thymine recognition. The dynamic linear range for Hg{sup 2+} detection has been determined in the concentrations from 10{sup −14} to 10{sup −8} M and a detection limit below 10{sup −14} M level was estimated, which is the best result of AlGaN/GaN HEMT biosensors for Hg{sup 2+} detection till now.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multi-focus parallel detection of fluorescent molecules at picomolar concentration with photonic nanojets arrays

Fluorescence sensing and fluorescence correlation spectroscopy (FCS) are powerful methods to detect and characterize single molecules; yet, their use has been restricted by expensive and complex optical apparatus. Here, we present a simple integrated design using a self-assembled bi-dimensional array of microspheres to realize multi-focus parallel detection scheme for FCS. We simultaneously illuminate and collect the fluorescence from several tens of microspheres, which all generate their own photonic nanojet to efficiently excite the molecules and collect the fluorescence emission. Each photonic nanojet contributes to the global detection volume, reaching FCS detection volumes of several tens of femtoliters while preserving the fluorescence excitation and collection efficiencies. The microspheres photonic nanojets array enables FCS experiments at low picomolar concentrations with a drastic reduction in apparatus cost and alignment constraints, ideal for microfluidic chip integration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Boron carbide coatings for neutron detection probed by x-rays, ions, and neutrons to determine thin film quality

Due to the present shortage of {sup 3}He and the associated tremendous increase of its price, the supply of large neutron detection systems with {sup 3}He becomes unaffordable. Alternative neutron detection concepts, therefore, have been invented based on solid {sup 10}B converters. These concepts require development in thin film deposition technique regarding high adhesion, thickness uniformity and chemical purity of the converter coating on large area substrates. We report on the sputter deposition of highly uniform large-area {sup 10}B{sub 4}C coatings of up to 2 μm thickness with a thickness deviation below 4% using the Helmholtz-Zentrum Geesthacht large area sputtering system. The {sup 10}B{sub 4}C coatings are x-ray amorphous and highly adhesive to the substrate. Material analysis by means of X-ray-Photoelectron Spectroscopy, Secondary-Ion-Mass-Spectrometry, and Rutherford-Back-Scattering (RBS) revealed low impurities concentration in the coatings. The isotope composition determined by Secondary-Ion-Mass-Spectrometry, RBS, and inelastic nuclear reaction analysis of the converter coatings evidences almost identical {sup 10}B isotope contents in the sputter target and in the deposited coating. Neutron conversion and detection test measurements with variable irradiation geometry of the converter coating demonstrate an average relative quantum efficiency ranging from 65% to 90% for cold neutrons as compared to a black {sup 3}He-monitor. Thus, these converter coatings contribute to the development of {sup 3}He-free prototype detectors based on neutron grazing incidence. Transferring the developed coating process to an industrial scale sputtering system can make alternative {sup 3}He-free converter elements available for large area neutron detection systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an assisting detection system for early infarct diagnosis

In this paper, a detection assisting system for early infarct detection is developed. This new developed method is used to assist the medical practitioners to diagnose infarct from computed tomography images of brain. Using this assisting system, the infarct could be diagnosed at earlier stages. The non-contrast computed tomography (NCCT) brain images are the data set used for this system. Detection module extracts the pixel data from NCCT brain images, and produces the colourized version of images. The proposed method showed great potential in detecting infarct, and helps medical practitioners to make earlier and better diagnoses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Contributed Review: Quantum cascade laser based photoacoustic detection of explosives

Detecting trace explosives and explosive-related compounds has recently become a topic of utmost importance for increasing public security around the world. A wide variety of detection methods and an even wider range of physical chemistry issues are involved in this very challenging area. Optical sensing methods, in particular mid-infrared spectrometry techniques, have a great potential to become a more desirable tools for the detection of explosives. The small size, simplicity, high output power, long-term reliability make external cavity quantum cascade lasers (EC-QCLs) the promising spectroscopic sources for developing analytical instrumentation. This work reviews the current technical progress in EC-QCL-based photoacoustic spectroscopy for explosives detection. The potential for both close-contact and standoff configurations using this technique is completely presented over the course of approximately the last one decade.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of endotoxin using a photonic crystal nanolaser

Fast and reliable detection of endotoxin (ET) in medical equipment and pharmaceutical products is an essential precursor to clinical treatment. In this study, we demonstrate the use of shifts in wavelength of photonic crystal nanolasers for sensing the Limulus amebocyte lysate reaction, which is a standard method for detecting ET. From working curves of wavelength shift vs ET concentration, whose correlation factors were as high as 98%, we detected a required concentration of 0.001 EU/ml within 33 min and detected a low concentration of 0.0001 EU/ml.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Note: Determining the detection efficiency of excited neutral atoms by a microchannel plate detector

We present a method for determining the detection efficiency of neutral atoms relative to keV ions. Excited D* atoms are produced by D{sub 2} fragmentation in a strong laser field. The fragments are detected by a micro-channel plate detector either directly as neutrals or as keV ions following field ionization and acceleration by a static electric field. Moreover, we propose a new mechanism by which neutrals are detected. We show that the ratio of the yield of neutrals and ions can be related to the relative detection efficiency of these species.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Waveguide-integrated single- and multi-photon detection at telecom wavelengths using superconducting nanowires

We investigate single- and multi-photon detection regimes of superconducting nanowire detectors embedded in silicon nitride nanophotonic circuits. At near-infrared wavelengths, simultaneous detection of up to three photons is observed for 120 nm wide nanowires biased far from the critical current, while narrow nanowires below 100 nm provide efficient single photon detection. A theoretical model is proposed to determine the different detection regimes and to calculate the corresponding internal quantum efficiency. The predicted saturation of the internal quantum efficiency in the single photon regime agrees well with plateau behavior observed at high bias currents.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electromagnetic diagnostic techniques for hypervelocity projectile detection, velocity measurement, and size characterization: Theoretical concept and first experimental test

A new measurement technique is suggested to augment the characterization and understanding of hypervelocity projectiles before impact. The electromagnetic technique utilizes magnetic diffusion principles to detect particles, measure velocity, and indicate relative particle dimensions. It is particularly suited for detection of small particles that may be difficult to track utilizing current characterization methods, such as high-speed video or flash radiography but can be readily used for large particle detection, where particle spacing or location is not practical for other measurement systems. In this work, particles down to 2 mm in diameter have been characterized while focusing on confining the detection signal to enable multi-particle characterization with limited particle-to-particle spacing. The focus of the paper is on the theoretical concept and the analysis of its applicability based on analytical and numerical calculation. First proof-of-principle experimental tests serve to further validate the method. Some potential applications are the characterization of particles from a shaped-charge jet after its break-up and investigating debris in impact experiments to test theoretical models for the distribution of particles size, number, and velocity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Defect detection inside superconducting 1.3 GHz cavities by means of x-ray fluorescence spectroscopy

X-ray fluorescence probe for detection of foreign material inclusions on the inner surface of superconducting cavities has been developed and tested. The setup detects trace element content such as a few micrograms of impurities responsible for thermal breakdown phenomena limiting the cavity performance. The setup has been customized for the geometry of 1.3 GHz TESLA-type niobium cavities and focuses on the surface of equator area at around 103 mm from the centre axis of the cavities with around 20 mm detection spot. More precise localization of inclusions can be reconstructed by means of angular or lateral displacement of the cavity. Preliminary tests confirmed a very low detection limit for elements laying in the high efficiency spectrum zone (from 5 to 10 keV), and a high angular resolution allowing an accurate localization of defects within the equator surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of efficient spin injection and detection in various systems using Fe{sub 3}O{sub 4} based spin injectors

Half-metal based spin injector devices for spin injection and detection application have proven to be efficient owing to their enhanced injection and detection efficiency. In this study, we extend the all-electrical spin injection and detection studies into different systems like Si and GaAs using half-metal Fe{sub 3}O{sub 4} as a spin injector in the presence and absence of tunnel barrier MgO. Injection into GaAs is verified using conventional Fe/MgO/GaAs devices. Room temperature spin injection into both p-type and n-type Si is achieved and the spin injection could be observed down to 100 K. Obtained spin relaxation time for these n-type and p-type Si at different temperatures agree well with the existing reports. Further, the temperature dependent spin injection and detection is also successfully achieved in Fe{sub 3}O{sub 4}/GaAs (n-type) Schottky devices, and a comparison study of the results with control experiment using Fe/MgO/GaAs (n-type) devices confirm the relaxation to be similar in the GaAs substrate, as expected. Hence, even Fe{sub 3}O{sub 4} material can be effectively used as an efficient spin injector as well as detector, making it an attractive candidate for the room temperature spintronics device applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pixel multiplexing technique for real-time three-dimensional-imaging laser detection and ranging system using four linear-mode avalanche photodiodes

The avalanche-photodiode-array (APD-array) laser detection and ranging (LADAR) system has been continually developed owing to its superiority of nonscanning, large field of view, high sensitivity, and high precision. However, how to achieve higher-efficient detection and better integration of the LADAR system for real-time three-dimensional (3D) imaging continues to be a problem. In this study, a novel LADAR system using four linear mode APDs (LmAPDs) is developed for high-efficient detection by adopting a modulation and multiplexing technique. Furthermore, an automatic control system for the array LADAR system is proposed and designed by applying the virtual instrumentation technique. The control system aims to achieve four functions: synchronization of laser emission and rotating platform, multi-channel synchronous data acquisition, real-time Ethernet upper monitoring, and real-time signal processing and 3D visualization. The structure and principle of the complete system are described in the paper. The experimental results demonstrate that the LADAR system is capable of achieving real-time 3D imaging on an omnidirectional rotating platform under the control of the virtual instrumentation system. The automatic imaging LADAR system utilized only 4 LmAPDs to achieve 256-pixel-per-frame detection with by employing 64-bit demodulator. Moreover, the lateral resolution is ∼15 cm and range accuracy is ∼4 cm root-mean-square error at a distance of ∼40 m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of atomic force microscopy cantilever displacement with a transmitted electron beam

The response time of an atomic force microscopy (AFM) cantilever can be decreased by reducing cantilever size; however, the fastest AFM cantilevers are currently nearing the smallest size that can be detected with the conventional optical lever approach. Here, we demonstrate an electron beam detection scheme for measuring AFM cantilever oscillations. The oscillating AFM tip is positioned perpendicular to and in the path of a stationary focused nanometer sized electron beam. As the tip oscillates, the thickness of the material under the electron beam changes, causing a fluctuation in the number of scattered transmitted electrons that are detected. We demonstrate detection of sub-nanometer vibration amplitudes with an electron beam, providing a pathway for dynamic AFM with cantilevers that are orders of magnitude smaller and faster than the current state of the art.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The first experience of using {sup 99m}Tc-Al{sub 2}O{sub 3}-based radiopharmaceutical for the detection of sentinel lymph nodes in cervical cancer patients

The purpose of the study was to evaluate the feasibility of using {sup 99m}Tc-Al{sub 2}O{sub 3}-based radiopharmaceutical, a novel molecular imaging agent for sentinel lymph node detection in patients with invasive cervical cancer. The study included 23 cervical cancer patients (T1aNxMx-T2bNxMx) treated at the Tomsk Cancer Research Institute. In the 18 hours before surgery, 80 MBq of the {sup 99m}Tc-Al{sub 2}O{sub 3} in peritumoral injected, followed by single-photon emission computed tomography (SPECT) of the pelvis and intraoperative SLN identification. Twenty-seven SLNs were detected by SPECT, and 34 SLNs were identified by intraoperative gamma probe. The total number of identified SLNs per patient ranged from 1 to 3 (the mean number of SLNs was 1.4 per patient). The most common site for SLN detection was the external iliac region (57.2%), followed by the internal iliac (14%), obturator (14%), presacral and retrosacral regions (14%), and the parametrial region (1%). Sensitivity in detecting SLNs was 100% for intraoperative SLN identification and 79% for SPECT image.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PLUTINO DETECTION BIASES, INCLUDING THE KOZAI RESONANCE

Because of their relative proximity within the trans-Neptunian region, the plutinos (objects in the 3:2 mean-motion resonance with Neptune) are numerous in flux-limited catalogs, and well-studied theoretically. We perform detailed modeling of the on-sky detection biases for plutinos, with special attention to those that are simultaneously in the Kozai resonance. In addition to the normal 3:2 resonant argument libration, Kozai plutinos also show periodic oscillations in eccentricity and inclination, coupled to the argument of perihelion ({omega}) oscillation. Due to the mean-motion resonance, plutinos avoid coming to pericenter near Neptune's current position in the ecliptic plane. Because Kozai plutinos are restricted to certain values of {omega}, perihelion always occurs out of the ecliptic plane, biasing ecliptic surveys against finding these objects. The observed Kozai plutino fraction f{sub koz}{sup obs} has been measured by several surveys, finding values between 8% and 25%, while the true Kozai plutino fraction f{sub koz}{sup true} has been predicted to be between 10% and 30% by different giant planet migration simulations. We show that f{sub koz}{sup obs} varies widely depending on the ecliptic latitude and longitude of the survey, so debiasing to find the true ratio is complex. Even a survey that covers most or all of the sky will detect an apparent Kozai fraction that is different from f{sub koz}{sup true}. We present a map of the on-sky plutino Kozai fraction that would be detected by all-sky flux-limited surveys. This will be especially important for the Panoramic Survey Telescope and Rapid Response System and Large Synoptic Survey Telescope projects, which may detect large numbers of plutinos as they sweep the sky. f{sub koz}{sup true} and the distribution of the orbital elements of Kozai plutinos may be a diagnostic of giant planet migration; future migration simulations should provide details on their resonant Kozai populations.

79 ASTRONOMY AND ASTROPHYSICS↗

Detection of stars within ∼0.8 in of Kepler objects of interest

We present an algorithm to search for the faint spectrum of a second star mixed with the spectrum of a brighter star in high resolution spectra. We model optical stellar spectra as the sum of two input spectra drawn from a vast library of stars throughout the H-R diagram. From typical spectra having a resolution of R = 60,000, we are able to detect companions as faint as 1% relative to the primary star in approximately the V and R bandpasses of photometry. We are also able to find evidence for triple and quadruple systems, given that any additional companions are sufficiently bright. The precise threshold percentage depends on the signal-to-noise of the spectrum and the properties of the two stars. For cases of non-detection, we place a limit on the brightness of any potential companions. This algorithm is useful for detecting faint orbiting companions and background stars that are angularly close to a foreground target star. The size of the entrance slit to the spectrometer, 0.87 × 3 arcsec (typically), sets the angular domain within which the second star can be detected. We analyzed Keck-HIRES spectra of 1160 California Kepler Survey objects of interest (KOI) searching for the secondary spectra, with the two goals of alerting the community to two possible host stars of the transiting planet and to dilution of the light curve. We report 63 California KOI showing spectroscopic evidence of a secondary star.

79 ASTRONOMY AND ASTROPHYSICS↗