Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Optomechanical interaction in fibre lasers with micro-optomechanical resonance structures

We report the results of studies of fibre lasers with passive modulators based on light-excited micro-optomechanical resonance structures (micro-oscillators). It is shown that in fibre lasers based on active fibres doped with rare-earth elements (Er, Er/Yb, Yb, Nd), the optomechanical interaction of laser radiation with micro-oscillators of various types (fibre-optic, microvolume) leads to self-oscillations of the characteristics of laser radiation at frequencies of relaxation oscillations and intermode beats synchronised with the frequencies of elastic eigenoscillations of micro-oscillators. It is found that in an ultra-long erbium – ytterbium fibre laser with a nonlinear mirror based on a microcantilever, laser photothermal excitation of the second mode of elastic transverse oscillations of the microcantilever makes it possible to perform passive mode locking exclusively due to Q-switching of the laser cavity. Pulsed lasing with a controlled repetition rate (∼76 kHz), a pulse duration of 2 – 5 μs and an output energy of 0.1 μJ per pulse is implemented. Based on a simplified physical model of the indicated fibre lasers with micro-oscillators, we have developed an approximate mathematical model describing the regimes of passive mode locking of fibre lasers with micro-oscillators that play the role of mirrors with a nonlinear reflection coefficient in the laser cavity. The prospects for the development and application of the considered laser systems are discussed. (control of laser radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental studies of 1.5 – 1.6 μm high-power single-frequency semiconductor lasers

High-power semiconductor laser systems based on 1.5 – 1.6 μm single-frequency distributed feedback (DFB) lasers with a sidewall Bragg diffraction grating are developed and their current – voltage, light – current, and spectral characteristics are experimentally studied. The characteristics of conventional lasers with a Fabry – Perot cavity and DFB lasers fabricated from one and the same heterostructure are compared. At a pump current not exceeding 700 mA, a conventional laser with a cavity length of 1.6 mm and a mesa-stripe width of 3 μm emits a power no lower than 200 mW versus 150 mW of the DFB laser; both lasers are mounted in a housing 11 mm in diameter. The DFB laser mounted in a butterfly housing emits a power no lower than 100 mW at the exit of the single-mode cable at a pump current not exceeding 500 mA, which, at a 60 % coupling efficiency, corresponds to a power no lower than 165 mW; the side-mode suppression ratio in this case is no lower than 53 dB. It is shown that the wavelength deviation with changing pump current and temperature is almost an order of magnitude lower for the DFB laser than for the conventional laser. (paper)

36 MATERIALS SCIENCE↗

Mechanisms of transport enhancement for self-propelled nanoswimmers in a porous matrix

Significance As with living microorganisms, many real-world applications of synthetic micro/nanoswimmers are likely to rely on transport in complex environments, a phenomenon that remains poorly understood. Here, we report anomalously rapid transport of self-propelled particles in a porous medium, where nanoswimmers escaped from cavities more than an order of magnitude faster than expected compared to corresponding Brownian particles. This phenomenon was determined to be due to nuanced effects associated with self-propulsion, including enhanced mobility in confinement, efficient surface-mediated searching for holes, and the abolition of barriers at cavity exits. These mechanisms are broadly generalizable, and the previously unknown transport efficiency of nanoswimmers in complex porous environments suggests tremendous opportunities in forward-looking applications, including drug delivery and environmental remediation.

59 BASIC BIOLOGICAL SCIENCES↗

Concept of circular-linear energy recovery accelerator to probe the energy frontier

Energy-frontier accelerators provide powerful tools performing high precision measurements confirming the fundamentals of the physics and broadening new research horizons. Such machines are either driven by circular or linear accelerators. The circular machines, having the centre-of-mass (CM) energy values reaching 200 GeV (for leptons) and above, experience beam energy loss and quality dilution, for example, due to synchrotron radiation, limiting the overall CM energy achievable and requiring a constant energy top-up to compensate the loss and the beam quality dilution. Linear colliders overcome these limitations, while the finite capabilities of generating high average current beams limits the luminosity. This is partially compensated by the quality of the colliding beams. In this work, we suggest a novel design of circular-linear accelerator based on the merging of the “non-emitting”, low-energy storage rings and energy recovery linear accelerators. We suggest using the recently considered dual-axis asymmetric cavities to enable the operation of such a system, and in particular the energy recovery from spent, high-intensity beams. The machine considered, under the scope of the SNOWMASS-2021 initiative, can be potentially used to reach ultimate energy frontiers in high-energy physics as well as to drive next generation light sources. The merging of circular and linear systems, and applications of dual axes cavities, should allow the maintaining of high beam quality, high luminosity, and high energy efficiency, while offering a flexible energy management and opening clear opportunity for reducing the running cost. We note that the numbers shown in the paper are for illustration purpose and can be improved further.

43 PARTICLE ACCELERATORS↗

Cosmic axions revealed via amplified modulation of the ellipticity of a laser

We propose a new axion dark matter detection strategy that employs optical readout of laser beam ellipticity modulations caused by axion-induced electric fields in a microwave cavity, using electro-optic (EO) crystals, enhanced by externally injected radio-frequency (rf) power. Building upon the variance-based probing method [Phys. Rev. D 107, 103005 (2023).], we extend this concept to the optical domain: A weak probe laser interacts with an EO crystal coupled to the resonant microwave cavity field at cryogenic temperatures, and the axion-induced electric field is revealed through induced ellipticity. The injected rf signal coherently interferes with that of the axion field, amplifying the optical response and significantly improving sensitivity. While our EO-based method employs a Fabry-Pérot resonator, we do not require Michelson interferometers. Our method, hence, enables compact, high-frequency axion searches, across the 0.5–50 GHz range. Operating at cryogenic temperatures not only suppresses thermal backgrounds, but, critically, allows the probing method to mitigate the quantum noise. This approach offers a scalable path forward for axion detection over the ∼(few−200) μ⁢eV mass range—covering the preferred parameter space for the postinflationary Peccei-Quinn axion dark matter—using compact, tunable systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Measurement of the Microwave Dielectric Loss of Sapphire in the Quantum Regime with Parts-per-Billion Sensitivity

Dielectric loss is known to limit state-of-the-art superconducting qubit lifetimes. Recent experiments imply upper bounds on bulk dielectric loss tangents on the order of 100 parts per billion but because these inferences are drawn from fully fabricated devices with many loss channels, these experiments do not definitely implicate or exonerate the dielectric. To resolve this ambiguity, we devise a measurement method capable of separating and resolving bulk dielectric loss with a sensitivity at the level of 5 ×10 –9 . The method, which we call the dielectric dipper, involves the in situ insertion of a dielectric sample into a high-quality microwave cavity mode. Smoothly varying the participation of the sample in the cavity mode enables a differential measurement of the dielectric loss tangent of the sample. The dielectric dipper can probe the low-power behavior of dielectrics at cryogenic temperatures and does so without the need for any lithographic process, enabling controlled comparisons of substrate materials and processing techniques. We demonstrate the method with measurements of sapphire grown by edge-defined film-fed growth (EFG) in comparison to high-grade sapphire grown by the heat-exchanger method (HEMEX). For EFG sapphire, we infer a bulk loss tangent of 63⁢(8) ×10 –9 and a substrate-air interface loss tangent of 15⁢(3) ×10 –4 (assuming a sample surface thickness of 3 nm). For a typical transmon, this bulk loss tangent would limit device quality factors to Q ≲20 ×10 6 , suggesting that bulk loss is likely the dominant loss mechanism in the longest-lived transmons on sapphire. We also demonstrate this method on HEMEX sapphire and bound its bulk loss tangent to be less than 19⁢(6) ×10 –9 . As this bound is about 3 times smaller than the bulk loss tangent of EFG sapphire, the use of HEMEX sapphire as a substrate would lift the bulk dielectric coherence limit of a typical transmon qubit to several milliseconds.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-volume tunable resonator for axion searches above 7 GHz

In this research, we present results from an experimental demonstration of a tunable thin-shell axion haloscope whose geometry decouples its overall volume from its resonant frequency, thereby evading the steep sensitivity degradation at high frequencies. An aluminum 2.6-l (41⁢λ 3 ) prototype, which tunes from 7.1 to 8.0 GHz, was fabricated and characterized at room temperature. An axion-sensitive, straightforwardly tunable TM 010 mode is clearly identified with a room-temperature quality factor, Q, of approximately 5000. The on-resonance E-field distribution is mapped and found to agree with numerical calculations. Anticipating future cryogenic operation, we develop an alignment protocol relying only on rf measurements of the cavity, maintaining a form factor of 0.57 across the full tuning range. These measurements demonstrate the feasibility of cavity-based haloscopes with operating volume V $\gg$ λ 3 . We discuss plans for future development and the parameters required for a thin-shell haloscope exploring the postinflationary axion parameter space (approximately 4 to 30 GHz) at Dine-Fischler-Srednicki-Zhitnitsky sensitivity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multidimensional Coherent Spectroscopy of Molecular Polaritons: Langevin Approach

We present a microscopic theory for nonlinear optical spectroscopy of N molecules in an optical cavity. Using the Heisenberg-Langevin equation, an analytical expression is derived for the time- and frequency-resolved signals accounting for arbitrary numbers of vibrational excitations. We identify clear signatures of the polariton-polaron interaction from multidimensional projections of the signal, e.g., pathways and timescales. Cooperative dynamics of cavity polaritons against intramolecular vibrations is revealed, along with a crosstalk between long-range coherence and vibronic coupling that may lead to localization effects. Our results further characterize the polaritonic coherence and the population transfer that is slower.

74 ATOMIC AND MOLECULAR PHYSICS↗

Experimental setup for high-resolution characterization of crystal optics for coherent X-ray beam applications

Stanford Synchrotron Radiation Lightsource serves a wide scientific community with its variety of X-ray capabilities. Recently, a wiggler X-ray source located at beamline 10-2 has been employed to perform high-resolution rocking curve imaging (RCI) of diamond and silicon crystals. X-ray RCI is invaluable for the development of upcoming cavity-based X-ray sources at SLAC, including the cavity-based X-ray free-electron laser and X-ray laser oscillator. In this paper, the RCI apparatus is described and experimental results are provided to validate its design. Future improvements of the setup are also discussed.

36 MATERIALS SCIENCE↗

Investigations Towards Ultra-Low Cost Nb 3 Sn SRF Fabrication via Melt Casted Bronze Route Processing

Here, a novel approach to fabricating Nb 3 Sn SRF cavities and other RF components using an ultra-low-cost melt casting fabrication process has been investigated. This simple, low cost melt casting technique has the potential to be used to fabricate nearly any superconducting Nb3Sn structure using either the Bronze Route (BR), Internal Tin (IT), External Tin (ET) processes as well as normal conducting pure copper (Cu) cavities. Most of the heat treated samples that were examined using SEM/EDX seemed to show a reasonable correlation of T c onset and transition width (ΔT c ) of the ingots initial/starting Sn content to the desired stoichiometric Nb 3 Sn phase, where the lower starting Sn content coupons resulted in lower T c 's with broader transition widths and the higher starting Sn coupons resulted in higher T c 's with narrower ΔT c ’s. The best samples had T c onsets ~17-18 K and ΔT c 's < 2 K. Two samples were further tested for RF surface resistance (R s ) and Quality Factor (Q) at JLAB. Here, these RF measurements were performed at 7.4 GHz using a calorimetric technique and showed two transitions, one at ~ 8 K and another at ~ 14 K; values of R s were at least two orders of magnitude higher than similar high quality Nb 3 Sn films directly deposited substrates by JLAB and with another superconducting transition close to the superconducting transition temperature of niobium. Substantial improvements in the processing variables ranging from higher quality of the initial ingots with higher Sn content, to better electropolishing and reaction heat treatment regimens will be necessary to realize improved RF performance metrics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electromagnetic and Engineering Design of a High-Current 15-MeV/u Cyclotron

The capability to produce high current, low loss, and extracted external ion beams presents an enabling technology for nuclear security, isotope production, and medical applications. We report on a novel, continuous-wave cyclotron for accelerating light ions with a charge-to-mass ratio of 1/2, which is designed for 1 mA maximum and 15 MeV/u energy. This article details the conceptual electromagnetic (EM) and engineering design including the 1.1 T sector magnets and 45 MHz, 200 kV radio frequency (RF) cavities. We discuss the cyclotron beam parameters with respect to potential commercial and industrial applications. The general concept and the accelerator’s layout are followed by a detailed EM design of magnets and RF cavities. Finally, practical engineering design considerations will be provided.

07 ISOTOPE AND RADIATION SOURCES↗

Progress and R/D challenges for FCC-ee SRF

The FCC-ee machines present a huge challenge for the RF systems, which need to be adapted to very diverse beam conditions going from moderate energy and high current for the Z machine to high energy and low beam current for the ttbar. This inverse scaling results naturally from a fixed budget for the synchrotron radiation, which the SRF cavities need to compensate. A global solution was elaborated for the FCC Conceptual Design Report (Abada in Eur Phys J Spec Top 228):261–623, 2019), and is referred here as the baseline. Recently, further studies have led to a new optimized baseline, still based on traditional elliptical cavities. In parallel, a novel concept, named the Slotted Waveguide ELLiptical (SWELL), was proposed with the potential of greatly simplified logistics and reduced costs. Under several aspects, all these changes call for enhanced performance of the RF systems. A vigorous R&D program has therefore continued since the publication of the CDR, with the aim of pushing the performance and demonstrating the feasibility of a more advanced baseline and, more recently, of the SWELL option. The progress and challenges of this ambitious program were presented in the dedicated SRF sessions at FCC week 2022 and are summarized in this paper.

47 OTHER INSTRUMENTATION↗

Finite Element Modeling of Electrochemical Polishing of Niobium in Hydrofluoric-Sulfuric Acid Electrolyte

Niobium (Nb) used in superconducting radio-frequency cavities requires smooth surface to achieve optimal performance. In this work, a finite element model that coupled electrochemistry, heat transfer, and fluid dynamics was developed to investigate the electrochemical polishing mechanisms of Nb, using experimentally measured polarization results of coupon samples as validations. The current and potential distribution, oxide growth kinetics of Nb in a complex cavity geometry was investigated as a function of temperature and coolant flow. A low temperature coolant with intermediate flow rate was found to reduce surface current and ensure oxide uniformity. These results could shed light on the design of future particle accelerators.

SRF accelerator cavity↗

Functional and genetic markers of niche partitioning among enigmatic members of the human oral microbiome

Abstract Introduction Microbial residents of the human oral cavity have long been a major focus of microbiology due to their influence on host health and intriguing patterns of site specificity amidst the lack of dispersal limitation. However, the determinants of niche partitioning in this habitat are yet to be fully understood, especially among taxa that belong to recently discovered branches of microbial life. Results Here, we assemble metagenomes from tongue and dental plaque samples from multiple individuals and reconstruct 790 non-redundant genomes, 43 of which resolve to TM7, a member of the Candidate Phyla Radiation, forming six monophyletic clades that distinctly associate with either plaque or tongue. Both pangenomic and phylogenomic analyses group tongue-specific clades with other host-associated TM7 genomes. In contrast, plaque-specific TM7 group with environmental TM7 genomes. Besides offering deeper insights into the ecology, evolution, and mobilome of cryptic members of the oral microbiome, our study reveals an intriguing resemblance between dental plaque and non-host environments indicated by the TM7 evolution, suggesting that plaque may have served as a stepping stone for environmental microbes to adapt to host environments for some clades of microbes. Additionally, we report that prophages are widespread among oral-associated TM7, while absent from environmental TM7, suggesting that prophages may have played a role in adaptation of TM7 to the host environment. Conclusions Our data illuminate niche partitioning of enigmatic members of the oral cavity, including TM7, SR1, and GN02, and provide genomes for poorly characterized yet prevalent members of this biome, such as uncultivated Flavobacteriaceae.

60 APPLIED LIFE SCIENCES↗

A field guide for aging passerine nestlings using growth data and predictive modeling

Abstract Background Accurate nestling age is valuable for studies on nesting strategies, productivity, and impacts on reproductive success. Most aging guides consist of descriptions and photographs that are time consuming to read and subjective to interpret. The Western Bluebird ( Sialia mexicana ) is a secondary cavity-nesting passerine that nests in coniferous and open deciduous forests. Nest box programs for cavity-nesting species have provided suitable nesting locations and opportunities for data collection on nestling growth and development. Methods We developed models for predicting the age of Western Bluebird nestlings from morphometric measurements using model training and validation. These were developed for mass, tarsus, and two different culmen measurements. Results Our models were accurate to within less than a day, and each model worked best for a specific age range. The mass and tarsus models can be used to estimate the ages of Western Bluebird nestlings 0–10 days old and were accurate to within 0.5 days for mass and 0.7 days for tarsus. The culmen models can be used to estimate ages of nestlings 0–15 days old and were also accurate to within less than a day. The daily mean, minimum, and maximum values of each morphometric measurement are provided and can be used in the field for accurate nestling age estimations in real time. Conclusions The model training and validation procedures used here demonstrate that this method can create aging models that are highly accurate. The methods can be applied to any passerine species provided sufficient nestling morphometric data are available.

59 BASIC BIOLOGICAL SCIENCES↗

High Force Spring Clamp System

This is the Final Technical Report for the work by Hyperboloid LLC using SBIR Grant # DE-SC0019579. The work responded to US DOE SBIR Topics FY2019, Phase 1, Release 1, August 13 2018, Topic: 30. a. (2) SRF cavity joining techniques that create vacuum seals without resorting to the use of bolted flanges in order to minimize particulates. Hyperboloid LLC designed, developed and tested the High Force Spring Clamp System characterized in Patent US 9756715 that is aimed at solving this topic. The patent is held by Thomas Jefferson National Accelerator Facility. The flange bolts are substituted with exceptionally high force, binder-clip-like “C” Clamps. The clamps are opened and applied by hydraulic based tooling called “Clamp Openers” using particle minimization methods. Model 1 Clamp reached the goal of sealing the SRF industry standard hexagonal section, aluminum alloy gasket, leak-free on a research cavity as determined by a superfluid helium challenge, at 2 K for 2 assembly cycles. Descriptions include the ANSYS calculations that determine the size and shape of the clamp, the details of the Clamp Opener construction, particle counts from sealing flanges using both bolts and clamps. Model 2 Clamp, at half the size, needing a softer metallic gasket to be successful, is more readily adaptable to Cryomodule designs. It was tested, but a needs soft gasket development to be successful.

43 PARTICLE ACCELERATORS↗

Contactless Position Measurement System for Remote Alignment of Highly Reflective Objects

The Contactless Position Measurement System (CPMS) permits automatic alignment of highly-reflecting components that cannot or should not be touched by human hands, such as those used in SRF cavities. CPMS also has application during maintenance of fusion reactors, when the components in the reactor are radioactive. The length of time for which humans can handle the components in order to carry out maintenance or repairs is limited. We would like to measure the relative positions of such objects so we can bring them into alignment with motorized stages, thus eliminating the need for human contact. The CPMS is a computer vision system that measures the location of highly reflective components to within a fraction of a millimeter by finding the edges of silhouette images. This is done by placing a uniform, infrared backlight behind the components, and viewing each component with two low-aberration, infrared cameras. Each of these stereoscopic cameras are located within a coordinate system we set up with reference platforms, light sources, and survey cameras distributed around the perimeter of the string assembly room, or fusion reactor. We obtain stereoscopic silhouette images of each component, and we use these to determine the position of the component within our string assembly coordinate system. The CPMS combines the silhouette images with knowledge of the dimensions of the objects to obtain the relative positions of components in its field of view. These position measurements then allow us to mechanically maneuver the components into contact. Once we know where they are, we can move the components to where they are supposed to be with motorized stages or other mechanical means, check they are in the right place, and bolt them together. In Phase I, we built a prototype infrared backlights and cameras, tested it, wrote an analysis program to fit the images. At a range of 50 cm, we are able to measure the relative positions of two stainless steel flanges with an accuracy of 150 μm rms. The next steps are to test the analysis program with motorized stages, build a full-size prototype, and implement it in an cleanroom with SRF cavity assembly. This can be done in a cost effective way given the materials with which the system is designed. As Open Source Instruments achieved more in Phase I than anticipated, despite not receiving a Phase II SBIR grant, we hope to move forward with product development and sales with a testing partner.

43 PARTICLE ACCELERATORS↗

COMBLE-ISLAS water isotopes in precipitation (COMBLEISLASISO)

During the measurement period, precipitation was sampled on daily to sub-daily basis with a sampling kit consiting of a clear plastic box (60x40x40 cm) mounted to a ground structure. Daily sampling lasted from 22 Feb to 24 Mar 2020. At a fixed time of day (10 UTC), samples were collected and the sampling box cleaned for the next sample. Additionally, during intense observations periods (IOPs) announced by ISLAS, ARMS scientists increased sampling frequency to sub-daily sampling. During the campaign period, 2 IOPs were conducted, with in total 12 samples taken. IOP1 lasted from 27 Feb 10 to 02 Mar 2020, and IOP2 lasted from 12 Mar to 14 Mar 2020. Solid precipitation in the box was then melted, transferred to an 8 ml glass vial, sealed and shipped to FARLAB (University of Bergen, Norway) for stable water isotope analysis. Measured stable isotope composition of precipitation samples will be related to conditions at other sampling locations, and at the evaporation site to inform about conservation of water isotope quantities. In the period from 22 Feb to 24 Mar, 23 daily samples were collected at 10 UTC for stable water isotope analysis. During the entire sampling period, a high variability of precipitation phase was encountered. Most samples were recovered in the form of graupel/snow (12 samples), as rain (7 samples), and the remaining samples fell as graupel, snow, rain or frozen rain. Precipitation amounts varied between <1 mm (26 Feb) and 140 mm (25 Feb) within the sampling box. Furthermore, higher-resolution sampling was conducted during 2 intense observation periods (IOPs). During IOP1, lasting from 27 Feb 10 UTC to 02 Mar 10 UTC, 7 samples were collected, all of them as solid phase precipitation. IOP2 lasted from 12 Mar 10 UTC to 14 Mar 09 UTC, and 5 samples (all as graupel/snow) were collected. Samples were processed according to FARLAB standard measurement procedures. In short, samples were transferred to 1.5 ml glass vials with rubber/PTFE septa (part #548-0907, VWR, USA). An autosampler (A0325, Picarro Inc) transferred ca. 2&micro;l per injection into a high-precision vapourizer (A0211, Picarro Inc, USA) heated to 110&deg;C. After blending with dry N2 (< 5 ppm H2O) the gas mixture was directed into the measurement cavity of a Cavity-Ring Down Spectrometer (L2140-i, Picarro Inc) for about 7 min with a typical water concentration of 20 000 ppm. Memory effects were reduced by two times measuring a vapour mixture at a mixing ratio of 50 000 ppm, obtained from 2 injections of 2 &micro;l for 5 min at the beginning of each new sample vial. Thereafter, another 6 injections of 2 &micro;l per sample were measured individually as described above, and averages of the last 5 injections were used for further processing. Three standards were measured at the beginning and end of each batch, including a drift standard DI2 (&delta;D: -50.72&plusmn;0.73 permil, &delta;18O: -7.63&plusmn;0.10 permil), and for calibration the laboratory standards GLW (&delta;D: -307.79&plusmn;0.75 permil, &delta;18O: -40.02&plusmn;0.07 permil) and EVAP2 (&delta;D: 9.52&plusmn;0.65 permil, &delta;18O: 1.81&plusmn;0.13 permil). A detailed calibration report is included with the final uploaded data set.

54 ENVIRONMENTAL SCIENCES↗