Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capacity test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

High-speed wide band 20 x 20 microwave switch matrix

The use of a dynamic switching matrix for future communication satellites will significantly increase the communication channel capacity and improve the system capability and flexibility. This paper describes the design and development of a unique coupler crossbar 20 x 20 microwave switch matrix. This paper also presents the test results of the proof-of-concept model that meets the requirements for a high-speed satellite switched, time division multiple access (SS-TDMA) system.

Coban, E.↗

Low temperature testing of Li-SOCl2 cells

The performance and safety characteristics Li-SOCl2 cells were evaluated at -40 C. Tests were conducted on cells of several defferent designs to determine the influence of cell design on performance and safety. The cells exhibited low operating voltages, poor voltage regulation, and low capacity at -40 C. The performance of the cells was found to be critically dependent on the cell design. No safety problems were observed during discharge to 2.0 V under constant current and constant load operating conditions. Cells subjected to prolonged periods of continuous drain at constant-load did not vent/rupture upon warm-up. Cells subjected to prolonged reversal were found to be potentially hazardous. Microcalorimetry and electrochemical impedance spectroscopy studies performed on the cells suggested that those containing a catalyst may exhibit poor shelf life.

Subbarao, S.↗

Transient response of a high-capacity heat pipe for Space Station Freedom

High-capacity heat pipe radiator panels have been proposed as the primary means of heat rejection for Space Station Freedom. In this system, the heat pipe would interface with the thermal bus condensers. Changes in system heat load can produce large temperature and heat load variations in individual heat pipes. Heat pipes could be required to start from an initially cold state, with heat loads temporarily exceeding their low-temperature transport capacity. The present research was motivated by the need for accurate prediction of such transient operating conditions. In this work, the cold startup of a 6.7-meter long high-capacity heat pipe is investigated experimentally and analytically. A transient thermohydraulic model of the heat pipe was developed which allows simulation of partially-primed operation. The results of cold startup tests using both constant temperature and constant heat flux evaporator boundary conditions are shown to be in good agreement with predicted transient response.

Ambrose, J. H.↗

Design and construction of a remote piloted flying wing

Currently, there is a need for a high-speed, high-lift civilian transport. Although unconventional, a flying wing could fly at speeds in excess of Mach 2 and still retain the capacity of a 747. The design of the flying wing is inherently unstable since it lacks a fuselage and a horizontal tail. The project goal was to design, construct, fly, and test a remote-piloted scale model flying wing. The project was completed as part of the NASA/USRA Advanced Aeronautics Design Program. These unique restrictions required us to implement several fundamental design changes from last year's Elang configuration including wing sweepback and wingtip endplates. Unique features such as a single ducted fan engine, composite structural materials, and an electrostatic stability system were incorporated. The result is the Banshee '94. Our efforts will aid future projects in design and construction techniques so that a viable flying wing can become an integral part of the aviation industry.

Costa, Alfred J.↗

Small Business Innovations (Robotic Wrist)

Under a Langley Research Center Small Business Innovation Research (SBIR) contract, Ross-Hime Designs, Inc. Minneapolis, MN, developed the Omni-Wrist actuator, which has a 25-pound capacity, 180 degrees of pitch/yaw, and 360 degrees of roll. Company literature calls it "the first successful singularity-free high-precision (robotic) wrist." Applications include spray painting, sealing, ultrasonic testing, welding and a variety of nuclear industry, aerospace and military uses.

Source record↗

Electrochemical Studies on LaNi(sub 5-x)Sn(sub x) Metal Hydride Alloys

Electrochemical studies were performed on LaNi(sub 5-x)Sn(sub x) with 0(less than or equal to)x(less than or equal to)0.5. We measured the effect of the Sn substituent on the kinetics of charge transfer and diffusion during hydrogen absorption and desorption, and the cyclic lifetimes of LaNi(sub 5-x)Sn(sub x) electrodes in 250 mAh laboratory test cells. We report beneficial effects of making small substitutions of Sn for Ni in LaNi(sub 5) on the performance of metal hydride alloy anode in terms of cyclic lifetime, capacity and kinetics. The optimal concentration of Sn in LaNi(sub 5-x)Sn(sub x) alloys for negative electrodes in alkaline rechargable secondary cells was found to lie in the range 0.25(less than or equal to)x(less than or equal to)0.3.

metal hydride alloys hydrogen absorption↗

Co-Adsorption of Ammonia and Formaldehyde on Regenerable Carbon Sorbents for the Primary Life Support System (PLSS)

Results are presented on the development of a reversible carbon sorbent for trace-contaminant (TC) removal for use in Extravehicular Activities (EVAs), and more specifically in the Primary Life Support System (PLSS). The current TC-control technology involves the use of a packed bed of acid-impregnated granular charcoal, which is deemed non-regenerable, while the carbon-based sorbent under development in this project can be regenerated by exposure to vacuum at room temperature. Data on concurrent sorption and desorption of ammonia and formaldehyde, which are major TCs of concern, are presented in this paper. A carbon sorbent was fabricated by dry impregnation of a reticulated carbon-foam support with polyvinylidene chloride, followed by carbonization and thermal oxidation in air. Sorbent performance was tested for ammonia and formaldehyde sorption and vacuum regeneration, with and without water present in the gas stream. It was found that humidity in the gas phase enhanced ammonia-sorption capacity by a factor larger than two. Co-adsorption of ammonia and formaldehyde in the presence of water resulted in strong formaldehyde sorption (to the point that it was difficult to saturate the sorbent on the time scales used in this study). In the absence of humidity, adsorption of formaldehyde on the carbon surface was found to impair ammonia sorption in subsequent runs; in the presence of water, however, both ammonia and formaldehyde could be efficiently removed from the gas phase by the sorbent. The efficiency of vacuum regeneration could be enhanced by gentle heating to temperatures below 60 deg.

Wojtowicz, Marek A.↗

Optimization Considerations for Annular Linear Electromagnetic Pumps for Space Nuclear Power and Propulsion

The Need for High Performance Liquid Metal Pumps Testing Power and Efficiency Considerations Liquid metal cooled reactors is one option for space nuclear power for settlements and electric propulsion vehicles (Snap 10 A, SP100, Soviet Topaz reactors) • High heat capacity • High boiling point (NaK~1200K) • Simplified heat transfer loop • Good neutronics Liquid metal EM pumps are desired over conventional pumps owing to lack of seals, bearings elimination of cavitation issues, lower mass and eliminates mechanical impeller • Conduction pumps (typically DC-high current, low voltage; ~5% efficiency) • Induction pumps (typically AC, high efficiency ~40%) Annular linear induction pump is an EM pump with no moving parts and of cylindrical/tubular geometry which makes it straightforward to integrate in conventional piping architectures • Higher inherent reliability • Invented by Einstein and Szilard

ALIP↗

Low cost solar array project silicon materials task. Development of a process for high capacity arc heater production of silicon for solar arrays

Silicon tetrachloride and a reductant (sodium) will be injected into an arc heated mixture of hydrogen and argon, yielding silicon and gaseous sodium chloride. Detailed characterization of the Sonicore sodium injection nozzle, using water as the test fluid was completed. Results indicated that flow rates of 45 gph sodium and 50 scfm argon should produce sufficiently small droplet sizes. The design effort was also completed for the test system preparation which was divided into two categories: (1) system components and (2) test system-laboratory integration.

Reed, W. H.↗

Cycle life test and failure model of nickel-hydrogen cells

Six ampere hour individual pressure vessel nickel hydrogen cells were charge/discharge cycled to failure. Failure as used here is defined to occur when the end of discharge voltage degraded to 0.9 volts. They were cycled under a low earth orbit cycle regime to a deep depth of discharge (80 percent of rated ampere hour capacity). Both cell designs were fabricated by the same manufacturer and represent current state of the art. A failure model was advanced which suggests both cell designs have inadequate volume tolerance characteristics. The limited existing data base at a deep depth of discharge (DOD) was expanded. Two cells of each design were cycled. One COMSAT cell failed at cycle 1712 and the other failed at cycle 1875. For the Air Force/Hughes cells, one cell failed at cycle 2250 and the other failed at cycle 2638. All cells, of both designs, failed due to low end of discharge voltage (0.9 volts). No cell failed due to electrical shorts. After cell failure, three different reconditioning tests (deep discharge, physical reorientation, and open circuit voltage stand) were conducted on all cells of each design. A fourth reconditioning test (electrolyte addition) was conducted on one cell of each design. In addition post cycle cell teardown and failure analysis were performed on the one cell of each design which did not have electrolyte added after failure.

Smithrick, J. J.↗

Cycle life test and failure model of nickel-hydrogen cells

Six ampere hour individual pressure vessel nickel hydrogen cells were charge/discharge cycled to failure. Failure as used here is defined to occur when the end of discharge voltage degraded to 0.9 volts. They were cycled under a low earth orbit cycle regime to a deep depth of discharge (80 percent of rated ampere hour capacity). Both cell designs were fabricated by the same manufacturer and represent current state of the art. A failure model was advanced which suggests both cell designs have inadequate volume tolerance characteristics. The limited existing data base at a deep depth of discharge (DOD) was expanded. Two cells of each design were cycled. One COMSAT cell failed at cycle 1712 and the other failed at cycle 1875. For the Air Force/Hughes cells, one cell failed at cycle 2250 and the other failed at cycle 2638. All cells, of both designs, failed due to low end of discharge voltage (0.9 volts). No cell failed due to electrical shorts. After cell failure, three different reconditioning tests (deep discharge, physical reorientation, and open circuit voltage stand) were conducted on all cells of each design. A fourth reconditioning test (electrolyte addition) was conducted on one cell of each design. In addition post cycle cell teardown and failure analysis were performed on the one cell of each design which did not have electrolyte added after failure. Previously announced in STAR as N83-25038

Smithrick, J. J.↗

Biotic degradation of acetonitrile. Limitations, controls and conversion rates

This document has been prepared to support Washington River Protection Solutions (WRPS) in their evaluation of technologies to remediate organic compounds in the Liquid Effluent Retention Facility (LERF)/Effluent Treatment Facility (ETF) during direct feed low activity waste (DFLAW) operations at Hanford. This report summarizes the results of a review of the available literature describing aerobic and anaerobic biological treatment of acetonitrile and proposes a test matrix to evaluate microbial degradation rates of acetonitrile. Numerous studies describe acetonitrile degradation by pure culture strains of bacteria, fungi, and yeast; however, the purpose of this review was to provide estimations of degradation under conditions that more closely approximate the Liquid Effluent Retention Facility (LERF) basins at the Hanford Site. To this end, documented limitations, controls, and conversion rates are summarized for mixed and natural microbial communities being maintained or operated as a biological treatment for wastewater processing. Based on the literature evaluation, the inherent capacity and rates of microbial degradation of acetonitrile are sufficiently high that if applied in the LERF basins, acetonitrile removal would be achieved. To be clear, though, published studies have not been conducted under conditions that approximate or that could be directly related to the LERF basins. Thus, a focused test matrix the encompasses LERF relevant conditions to specifically measure microbial degradation of acetonitrile is proposed and the results would provide the strong technical justification for use of this low-cost efficient biological process at LERF during DFLAW operations and beyond.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Heating performance of an air source heat pump with a portable thermoelectric subcooler

This study investigates the heating performance of an integrated air-source heat pump (ASHP) with a thermoelectric subcooler (TES) module, revealing significant performance enhancements, particularly in colder temperatures. Results show that adding the portable TES boosts the ASHP's heating capacity, making it feasible for residential applications. The coefficient of performance (COP) for the TE system, which is influenced by condensing temperatures and ambient conditions, ranges from 1.51 to 2.07. If condensing temperatures are consistently maintained above 35 °C, a TE COP of approximately 2.07 is achievable, supporting system downsizing and reducing supplemental heating. When coupled with an oversized indoor coil, the TES-ASHP system delivers comparable heating to a baseline unit while achieving a 10 % higher COP. Capacity increases by 8.7 %–24 % with TES in colder conditions, though COP declines by 9 %–18 %, diminishing as temperatures drop. Compared to systems with supplemental heating, this setup achieves a COP 10 %–17 % higher. Future work will involve extended field testing in various climates, exploration of advanced materials for thermal efficiency, and assessment of alternative refrigerants to improve performance and sustainability. This integrated ASHP-TES system holds promise for increased efficiency and reduced environmental impact in cold climates.

Air source heat pump↗

Embedded Optical Sensing Systems For Distribution Transformer Monitoring

Traditional utility monitoring systems do not provide real-time visibility into the condition of transformers or accurate performance measurements. This has resulted in the use of lagging indicators, such as oil sample analysis, typically requiring expensive field visits, grid outages, and laboratory sample testing. This presentation reviews the use of optical sensing systems for managing transformers and improving grid resiliency and safety. The sensing systems allow direct internal monitoring of critical transformer components. Versatility covering different monitoring parameters of interest in embedded configurations for new transformers and a retrofittable configuration for older transformers is achieved by applying hair-thin multiplexed fiber-optic and other low-profile optical sensors in combination with a high-resolution optical readout and advanced analytics. Under an initiative funded by the DOE Office of Electricity, PARC, GE and Con Edison built, tested, and qualified commercial network transformers with embedded optical sensing systems. The parameters monitored were validated across a range of scenarios with lab instruments typically used for qualification testing. An ongoing field trial to demonstrate the robustness of the technology for remote monitoring through the industrial internet under demanding grid deployment conditions in New York City is showing promise toward scale-up of the technology. This presentation will provide an overview of the typical pain points in managing transformers and parameters for monitoring. It will also cover the requirements for highly constrained installations that need to have a larger capacity and flexible rating but that must fit into a tight space. The unique capabilities of optical sensing systems and a low-cost approach to interpreting the signals from sensors in transformers for predictive maintenance will be covered. The presentation will discuss the compatibility of the sensors in the transformer environment. It will discuss the validation testing per IEEE standards that enabled the solution to be implemented in field-deployable commercial transformers. The initial results from the field deployment and the potential for the technology to provide systematic alerts for unsafe/unexpected events will be discussed. The technology could enable utility professionals to gain information they can use to better plan for maintenance/management, and improve grid performance. This would in turn accommodate DERs and other evolving grid market dynamics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electromagnetic Energy-Assisted Thermal Conversion of Fossil-Based Hydrocarbons to Low-Cost Hydrogen

The goal of this project was to develop and optimize catalysts for methane decomposition, particularly focusing on regeneration via an electromagnetic energy-assisted mechanism, to produce hydrogen more cost-effectively compared to electrolysis routes. To achieve this goal, the project pursued several key objectives. The project began with the preparation and testing of various catalysts. A nickel-silica based catalyst was identified as the most promising material for the pyrolysis of methane into carbon and hydrogen. Kinetic parameters for methane decomposition were determined, aiding in computational modeling efforts. Structured catalysts were investigated, highlighting the need for frequent cleaning or regeneration to maintain performance, with methane conversion rates exceeding 70% in tube furnace tests. Computational fluid dynamics modeling was employed to optimize reactor designs and electrode angles, leading the project team to propose a multi-compartment thermal conversion system for larger setups. This modeling work was important in understanding reaction characteristics, carbon deposition rates, and temperature profiles under various conditions. A bench-scale reactor system was assembled to evaluate catalyst regeneration using electromagnetic energy-assisted mechanisms. Experiments demonstrated the potential for carbon removal, though further optimization is needed. The carbon produced from the methane conversion process was evaluated for potential use in lithium-ion battery electrodes. The carbon exhibited properties similar to commercially available high-purity multi-walled carbon nanotubes and nanofibers, with a carbon content greater than 95%. Coin cell batteries assembled with this carbon showed that lower replacement levels (10% to 33%) outperformed the control group, improving specific capacity density and stability. However, higher replacement levels (100%) demonstrated poorer performance, suggesting that excessive carbon substitution negatively impacts battery performance. These findings indicate the potential marketability of the produced carbon as a component in lithium-ion batteries, though further testing is necessary to confirm long-term advantages and disadvantages associated with the use of the carbon product. These results however justified further technoeconomic assessments to determine if the process can provide low-cost hydrogen. The economic feasibility and technical performance of methane decomposition for hydrogen production were assessed, focusing on three plant configurations: 100E (electrically heated), 100C (combustion heated using produced hydrogen), and PE-Hybrid (a combination of pyrolysis (indicating decomposition) and electrolysis). The Levelized Cost of Hydrogen (LCOH) for the pyrolysis configurations was found to be approximately 25% lower than that of electrolysis. The 100E configuration had the lowest LCOH at $\$$3.12/kg. Including carbon product sales significantly improved the economics, with the 100C configuration achieving a negative LCOH of -$\$$0.35/kg. The PE-Hybrid configuration was not economically advantageous compared to pure pyrolysis plants due to its complexity and additional equipment requirements. Ultimately, methane pyrolysis presents a viable method for near carbon dioxide-free hydrogen production, with significant economic advantages over electrolysis, especially when considering the sale of carbon byproducts. The 100E and 100C configurations showed the most promise, with the choice between them ultimately depending on the prices of power and natural gas. In conclusion, this technology has the potential to lower hydrogen production costs by leveraging the methane decomposition process with the sale of valuable carbon byproducts. By optimizing catalyst performance and integrating electromagnetic energy-assisted regeneration, the process can achieve higher efficiency and economic viability, making it a competitive alternative to traditional hydrogen production methods.

08 HYDROGEN↗

Modeling, Design, and Testing of a Novel Biphasic Solvent-Enabled Absorption System for Post-Combustion Carbon Capture

A novel absorption process enabled by a new class of biphasic solvents for post-combustion carbon capture (BiCAP) is presently being developed at the University of Illinois at Urbana-Champaign. The new biphasic solvents are water-lean solvent blends that develop dual liquid phases with the absorbed CO2 highly enriched in one of the phases. These solvents are superior in CO2 capacity and have high thermal and oxidative stability compared to MEA. The BiCAP technology features a unique process configuration of multi-stage CO2 absorption and liquid–liquid phase separation during CO2 absorption, allowing continual separation and removal of the CO2-enriched liquid phase for maintaining low solvent viscosity and a fast absorption rate. A 40 kWe-scale skid has recently been constructed at the Abbott Power Plant in Champaign, IL, to test the BiCAP solvent in continuous operation with a slipstream of real post-combustion flue gas. Along with improvements in the stripping configuration including cold feed bypass, the process is expected to achieve a minimum reboiler duty of 2,210 kJ/kg CO2 captured at a stripper operating pressure of 6 bar.

20 FOSSIL-FUELED POWER PLANTS↗

Intern Poster - Characterizing Wildland Fire Conditions for Lab-Scale Testing of Advanced Conductors

As the demand for energy increases each year, electric utilities face the challenge of delivering more power than before. Current transmission/distribution networks have proved reliable in the past but are physically unable to meet higher energy demands. Traditional overhead conductor cables (such as Aluminum Conductor Steel Reinforced (ACSR)) are limited in their ability to hold more voltage due to increased temperatures and resulting sag. When the cable sags, it comes closer to the ground, violating clearance standards and presenting an environmental risk. Newly developed advanced conductors, aluminum conductors with carbon fiber composite cores (instead of steel) mitigate this risk. Advanced conductors are engineered to perform in higher operating temperatures without sagging, thus possessing higher capacity potential. Regardless, utilities are hesitant to adopt this new technology due to scarcity of use data. The largest looming risk for utilities is wildland fires. There is little to no data on how advanced conductors perform in the event of a wildland fire. To address these concerns, this project aims to test the mechanical performance of advanced conductors in these conditions, providing utilities use data for their reference. The initial steps of the project will be to design and construct a fire table apparatus to reproduce wildland fire conditions, calculate proper parameters for this testing, and analyze the impact mathematically. After completing these actions, the next steps will be to test the advanced conductors in the laboratory fire chamber.

24 POWER TRANSMISSION AND DISTRIBUTION↗