Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

A Cryogenic, Insulating Suspension System for the High Resolution Airborne Wideband Camera (HAWC)and Submillemeter And Far Infrared Experiment (SAFIRE) Adiabatic Demagnetization Refrigerators (ADRs)

The High Resolution Airborne Wideband Camera (HAWC) and the Submillimeter And Far Infrared Experiment (SAFIRE) will use identical Adiabatic Demagnetization Refrigerators (ADR) to cool their detectors to 200mK and 100mK, respectively. In order to minimize thermal loads on the salt pill, a Kevlar suspension system is used to hold it in place. An innovative, kinematic suspension system is presented. The suspension system is unique in that it consists of two parts that can be assembled and tensioned offline, and later bolted onto the salt pill.

Voellmer, George M.↗

Thermal Vacuum Test Performance of the Hubble Space Telescope (HST) Wide Field Camera 3 (WFC3) Variable Conductance Heat Pipe Assembly

The Variable Conductance Heat Pipe (VCHP) Assembly of the HST Wide Field Camera 3 was subjected to thermal vacuum (TN) environmental testing. The test program included both maximum and minimum environments as well as simulated on-orbit cycling. Elements of the VCHP assembly included a VCHP, an optical bench cold plate with an imbedded constant conductance heat pipe, and a VCHP reservoir radiator with a proportionally controlled heater. The purpose of the test was to characterize and demonstrate the assembly s ability to control the temperature of the cold plate, which provides a stable thermal environment for the instrument s optical bench. This paper discusses the VCHP Assembly control performance and control authority during the dynamic hot and cold 90-minute orbit cycling test phases.

Cleveland, Paul E.↗

The Seasonal Behavior of Water Ice Clouds in the Tharsis and Valles Marineris Regions of Mars: Mars Orbiter Camera Observations

The Mars Orbiter Camera (MOC) was used to obtain global maps of the Martian surface. The maps used were acquired between March 15, 1999 (LS = 110 ) and July 31, 2001 (L(sub s) = 110), corresponding to approximately one and a quarter martian years. In this work we focused on water ice clouds associated with the surface features of Olympus Mons, Ascraeus Mons, Pavonis Mons, Arsia Mons, Alba Patera, and the Valles Marineris canyon system. Using these data, we have made three types of quantitative measurements to characterize the cloud activity: 1) cloud area and location, 2) cloud height, and 3) cloud optical depth. We have also searched for short period variations in the cloud areas.

J L Benson↗

Characterizing Digital Camera Systems: A Prelude to Data Standards

This viewgraph presentation profiles: 1) Digital imaging systems; 2) Specifying a digital imagery product; and 3) Characterization of data acquisition systems. Advanced large array digital imaging systems are routinely being used. Digital imagery guidelines are being developed by ASPRS and ISPRS. Guidelines and standards are of little use without standardized characterization methods. Characterization of digital camera systems is important for supporting digital imagery guidelines. Specifications are characterized in the lab and/or the field. Laboratory characterization is critical for optimizing and defining performance. In-flight characterization is necessary for an end-to-end system test.

Ryan, Robert↗

An Array of Frequency Selective Bolometers (FSB) for the Spectral Energy Distribution (SPEED) Camera

The SPEED camera is being developed to study the spectral energy distributions of high redshift galaxies using the Heinrich Hertz Telescope (HHT) in Arizona. SPEED requires a small cryogenic detector array of 2x2 pixels with each pixel having four frequency bands in the 150-350 GHz range. Here we describe the development of the detector array of these high efficiency FSBs. The FSB design provides the multi-pixel multi-spectral band capability required for SPEED in a compact stackable array. The SPEED bolometers will use proximity effect superconducting transition edge sensors as their temperature-sensing element allowing for higher levels of multiplexing in future applications.

Silverberg, R. F.↗

Coordinated Observations of Aeolian Features from the Mars Exploration Rovers (MER) and the Mars Express High Resolution Stereo Camera and Other Orbiters

Surface features associated with aeolian (wind) processes at the Mars Exploration Rover (MER) landing sites for Spirit (Gusev crater) and Opportunity (Sinus Meridiani) were observed from the surface and from orbit through coordinated observations by the rovers and the Mars Express orbiter High Resolution Stereo Camera and compared with features seen in other orbiter data and with wind vectors predicted by a numerical mesoscale model of the atmosphere.

Greeley, R.↗

3D Surface Reconstruction and Automatic Camera Calibration

Illustrations in this view-graph presentation are presented on a Bayesian approach to 3D surface reconstruction and camera calibration.Existing methods, surface analysis and modeling,preliminary surface reconstruction results, and potential applications are addressed.

Jalobeanu, Andre↗

Feasibility Study of Utilizing Existing Infrared Array Cameras for Daylight Star Tracking on NASA's Ultra Long Duration Balloon (ULDB) Missions

The purpose of this study was to investigate the feasibility of developing a daytime star tracker for ULDB flights using a commercially available off-the-shelf infrared array camera. This report describes the system used for ground-based tests, the observations, the test results, and gives recommendations for continued development.

Tueller, Jack↗

Visualization of Subsurface Defects in Composites using a Focal Plane Array Infrared Camera

A technique for enhanced defect visualization in composites via transient thermography is presented in this paper. The effort targets automated defect map construction for multiple defects located in the observed area. Experimental data were collected on composite panels of different thickness with square inclusions and flat bottom holes of different depth and orientation. The time evolution of the thermal response and spatial thermal profiles are analyzed. The pattern generated by carbon fibers and the vignetting effect of the focal plane array camera make defect visualization difficult. An improvement of the defect visibility is made by the pulse phase technique and the spatial background treatment. The relationship between a size of a defect and its reconstructed image is analyzed as well. The image processing technique for noise reduction is discussed.

Plotnikov, Yuri A.↗

A quasi-static method for determining the characteristics of a motion capture camera system in a "split-volume" configuration

The purpose of this study was to determine the accuracy, repeatability and resolution of a six-camera Motion Analysis system in a vertical split-volume configuration using a unique quasi-static methodology. The position of a reflective marker was recorded while it was moved quasi-statically over a range of 2.54 mm (0.100 inches) via a linearly-translating table. The table was placed at five different heights to cover both sub-volumes and the overlapping region. Data analysis showed that accuracy, repeatability and resolution values were consistent across all regions of the split-volume, including the overlapping section.

NASA Center JSC↗

A 90GHz Bolometer Camera Detector System for the Green Bank Telescope

We describe a close-packed, two-dimensional imaging detector system for operation at 90GHz (3.3mm) for the 100 m Green Bank Telescope (GBT) This system will provide high sensitivity (<1mjy in 1s rapid imaging (15'x15' to 250 microJy in 1 hr) at the world's largest steerable aperture. The heart of this camera is an 8x8 close packed, Nyquist-sampled array of superconducting transition edge sensor bolometers. We have designed and are producing a functional superconducting bolometer array system using a monolithic planar architecture and high-speed multiplexed readout electronics. With an NEP of approx. 2.10(exp 17) W/square root Hz, the TES bolometers will provide fast linear sensitive response for high performance imaging. The detectors are read out by and 8x8 time domain SQUID multiplexer. A digital/analog electronics system has been designed to enable read out by SQUID multiplexers. First light for this instrument on the GBT is expected within a year.

Benford, Dominic J.↗

Smart Camera Technology Increases Quality

When it comes to real-time image processing, everyone is an expert. People begin processing images at birth and rapidly learn to control their responses through the real-time processing of the human visual system. The human eye captures an enormous amount of information in the form of light images. In order to keep the brain from becoming overloaded with all the data, portions of an image are processed at a higher resolution than others, such as a traffic light changing colors. changing colors. In the same manner, image processing products strive to extract the information stored in light in the most efficient way possible. Digital cameras available today capture millions of pixels worth of information from incident light. However, at frame rates more than a few per second, existing digital interfaces are overwhelmed. All the user can do is store several frames to memory until that memory is full and then subsequent information is lost. New technology pairs existing digital interface technology with an off-the-shelf complementary metal oxide semiconductor (CMOS) imager to provide more than 500 frames per second of specialty image processing. The result is a cost-effective detection system unlike any other.

Source record↗

Star Formation as Seen by the Infrared Array Camera on Spitzer

The Infrared Array Camera (IRAC) onboard Spitzer has imaged regions of star formation (SF) in its four IR bands with spatial resolutions of approximately 2"/pixel. IRAC is sensitive enough to detect very faint, embedded young stars at levels of tens of Jy, and IRAC photometry can categorize their stages of development: from young protostars with infalling envelopes (Class 0/1) to stars whose infrared excesses derive from accreting circumstellar disks (Class 11) to evolved stars dominated by photospheric emission. The IRAC images also clearly reveal and help diagnose associated regions of shocked and/or PDR emission in the clouds; we find existing models provide a good start at explaining the continuum of the SF regions IRAC observes.

Smith, Howard A.↗

Final Report for the Advanced Camera for Surveys (ACS)

ACS was launched aboard the Space Shuttle Columbia just before dawn on March 1, 2002. At the time of liftoff, the Hubble Space Telescope (HST) was reflecting the early morning sun as it moved across the sky. After successfully docking with HST, several components were replaced. One of the components was the Advanced Camera for Surveys built by Ball Aerospace & Technologies Corp. (BATC) in Boulder, Colorado. Over the life of the HST contract at BATC, hundreds of employees had the pleasure of working on the concept, design, fabrication, assembly, and test of ACS. Those employees thank NASA - Goddard Space Flight Center and the science team at Johns Hopkins University (JHU) for the opportunity to participate in building a great science instrument for HST.

Source record↗

A 90GHz Bolometer Camera Detector System for the Green

We describe a close-packed, two-dimensional imaging detector system for operation at 90GHz (3.3 mm) for the 100m Green Bank Telescope (GBT). This system will provide high sensitivity (less than 1mJy in 1s) rapid imaging (15'x15' to 150 micron Jy in 1 hr) at the world's largest steerable aperture. The heart of this camera is an 8x8 close-packed, Nyquist-sampled array of superconducting transition edge sensor (TES) bolometers. We have designed and are producing a functional superconducting bolometer array system using a monolithic planar architecture and high-speed multiplexed readout electronics. With an NEP of approximately 2 x 10(exp -17) W/square root of Hz, the TES bolometers will provide fast, linear, sensitive response for high performance imaging. The detectors are read out by an 8x8 time domain SQUID multiplexer. A digital/analog electronics system has been designed to enable read out by SQUID multiplexers. First light for this instrument on the GBT is expected within a year.

Benford, Dominic J.↗

The First Six Months of Iapetus Observations by the Cassini ISS Camera

Since Saturn arrival in June 2004, Iapetus has been studied intensively by the Cassini ISS camera [1] at various ranges. The first of two relatively close flybys in the primary mission occurred on Dec 31, 2004 at an altitude of approx.123,400 km over the northern leading hemisphere, resulting in images with a minimum pixel scale of 740 m. Detailed results of this flyby are given in [2], while this abstract covers the observations obtained earlier. Among the most important discoveries are: (a) Four giant impact basins with diameters between 390 and 550 km were detected, three of them are located in the dark terrain [3]. (b) Data revealed a >1300 km long ridge that marks exactly Iapetus' equator within the dark terrain. Individual mountains within the western part of the ridge reach heights of approx.20 km over surrounding terrain [3]. (c) Impact craters were confirmed to be the main geological feature within the dark terrain and at high southern latitudes. (d) There are numerous craters with dark walls roughly facing towards the central parts of the dark hemisphere [3]. (e) Almost all parts of Iapetus have been imaged at least at low resolution (< 60 km/pxl).

Denk, T.↗

CHAMP - Camera, Handlens, and Microscope Probe

CHAMP (Camera, Handlens And Microscope Probe) is a novel field microscope capable of color imaging with continuously variable spatial resolution from infinity imaging down to diffraction-limited microscopy (3 micron/pixel). As an arm-mounted imager, CHAMP supports stereo-imaging with variable baselines, can continuously image targets at an increasing magnification during an arm approach, can provide precision range-finding estimates to targets, and can accommodate microscopic imaging of rough surfaces through a image filtering process called z-stacking. Currently designed with a filter wheel with 4 different filters, so that color and black and white images can be obtained over the entire Field-of-View, future designs will increase the number of filter positions to include 8 different filters. Finally, CHAMP incorporates controlled white and UV illumination so that images can be obtained regardless of sun position, and any potential fluorescent species can be identified so the most astrobiologically interesting samples can be identified.

Mungas, G. S.↗