Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “benchmarks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Comparison of MAVRIC/MONACO and TRIPOLI-4{sup R} simulations of the LLNL pulsed spheres benchmark experiments - 25403

Simulations of the Lawrence Livermore Pulsed Spheres with MAVRIC/Monaco and TRIPOLI-4{sup R} are presented. Both codes use ENDF/B-VII.1 cross section data, but TRIPOLI-4{sup R} also uses cross section data based on JEFF-3.1.1. The MAVRIC/Monaco simulations were performed with the SCALE 6.2.2 release while the TRIPOLI-4{sup R} simulations used an internal development version of the code. For the most part, the simulated and measured neutron counts agree within 30%. Simulated gamma flux data is compared, as well. There are no measured gamma data. The agreement between the simulated gamma flux spectra is often within 10% or less, but there some notable differences, especially when comparing simulations using ENDF/B-VII.1 and JEFF 3.1.1 based cross section data. The comparison of photon simulations suggests that improvements are needed in the cross-section data, cross section processing codes, and/or transport codes and gamma measurement data is needed for experimental validation. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Surpassing 10% Efficiency Benchmark for Nonfullerene Organic Solar Cells by Scalable Coating in Air from Single Nonhalogenated Solvent

Here, the commercialization of nonfullerene organic solar cells (OSCs) relies critically on the response under typical operating conditions (for instance, temperature, humidity) and the ability of scale-up. Despite the rapid increase in power conversion efficiency (PCE) of spin-coated devices fabricated in a protective atmosphere, the device efficiencies of printed nonfullerene OSC devices by blade-coating are still lower than 6%. This slow progress significantly limits the practical printing of high-performance nonfullerene OSCs. Here, a new and stable nonfullerene combination was introduced by pairing a commercially available nonfluorinated acceptor IT-M with the polymeric donor FTAZ. Over 12%-efficiency can be achieved in spincoated FTAZ:IT-M devices using a single halogen-free solvent. More importantly, chlorinefree, in air blade-coating of FTAZ:IT-M is able to yield a PCE of nearly 11%, despite a humidity of ≈50%. X-ray scattering results reveal that large π-π coherence lengths, high degree of faceon orientation with respect to the substrate, and small domain spacings of ≈20 nm are closely correlated with such high device performance. Our material system and approach yields the highest reported performance for nonfullerene OSC devices by a coating technique approximating scalable fabrication methods and holds great promise for the development of low-cost, low-toxicity, and high-efficiency OSCs by high-throughput production.

14 SOLAR ENERGY↗

Benchmarking of X‐Ray Fluorescence Microscopy with Ion Beam Implanted Samples Showing Detection Sensitivity of Hundreds of Atoms

Abstract Single impurities in insulators are now often used for quantum sensors and single photon sources, while nanoscale semiconductor doping features are being constructed for electrical contacts in quantum technology devices, implying that new methods for sensitive, non‐destructive imaging of single‐ or few‐atom structures are needed. X‐ray fluorescence (XRF) can provide nanoscale imaging with chemical specificity, and features comprising as few as 100 000 atoms have been detected without any need for specialized or destructive sample preparation. Presently, the ultimate limits of sensitivity of XRF are unknown – here, gallium dopants in silicon are investigated using a high brilliance, synchrotron source collimated to a small spot. It is demonstrated that with a single‐pixel integration time of 1 s, the sensitivity is sufficient to identify a single isolated feature of only 3000 Ga impurities (a mass of just 350 zg). With increased integration (25 s), 650 impurities can be detected. The results are quantified using a calibration sample consisting of precisely controlled numbers of implanted atoms in nanometer‐sized structures. The results show that such features can now be mapped quantitatively when calibration samples are used, and suggest that, in the near future, planned upgrades to XRF facilities might achieve single‐atom sensitivity.

36 MATERIALS SCIENCE↗

Benchmark Analysis on Magnetic and Photoluminescence Properties of Selective Metal Ions Doped ZnS Nanoparticles

The creation of diluted magnetic semiconductors (DMSs) at lower dimensions that exhibit room temperature ferromagnetism (RTFM) has been given immense significance for the fabrication of a new class of spintronic devices through utilizing spin degrees of freedom besides charge nature of electrons. In this view, nanocrystals of ZnS doped with 4% concentration of Fe, Co, Ni, Cr, Mn, Sr, Cu, and Ce have been synthesized at room temperature (RT) by chemical co-precipitation method. The samples were examined by various characterization techniques like energy dispersive spectroscopy (EDS), X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), vibrating sample magnetometer (VSM), and photoluminescence (PL). EDS spectra revealed the existence of parent elements in the prepared samples. XRD characterization disclosed hexagonal structures of nanocrystals, and no secondary phases were observed in all the samples except for Cu and Ni doped ZnS. FTIR data confirmed the proper substitution of dopants in the host lattice as all the graphs have almost same stretchings. The magnetic nature of each sample was evaluated from M-H graphs of VSM, and it corroborated the transition of magnetic properties due to doping. Pristine ZnS showed diamagnetic nature, while Fe and Sr doped ZnS evinced strong ferromagnetic and anti-ferromagnetic properties, respectively. Photoluminescence studies on Ce, Sr and Mn doped ZnS samples revealed strong emission peaks with enhanced luminescence properties compared to bare ZnS. Cu, Cr and Mn doped ZnS exhibited a red shift in emission wavelengths, whereas Co doped ZnS showed emission peak shifted towards the blue region as compared to the host lattice.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Adsorption of Tracer Gases in Geological Media: Experimental Benchmarking

The interaction of xenon with containment barriers can play a crucial role in the detection of underground nuclear explosions. Independent field experiments and laboratory-derived models have observed depressed surface level xenon concentrations and subsequently predicted geological capture rates. This work sought to experimentally verify those predictions by analyzing xenon transport though a two-bulb diffusion apparatus adapted for the study of geologic media. Novel to this work is the timescale over which these experiments were carried out, allowing the system to reach equilibrium, rather than relying on numerical models to treat the equilibrium concentration of each gas as a fit coefficient.

Byers, Maggie↗

ProvSec: Open Cybersecurity System Provenance Analysis Benchmark Dataset with Labels

System provenance forensic analysis has been studied by a large body of research work. This area needs fine granularity data such as system calls along with event fields to track the dependencies of events. While prior work on security datasets has been proposed, we found a useful dataset of realistic attacks and details that are needed for high-quality provenance tracking is lacking. We created a new dataset of eleven vulnerable cases for system forensic analysis. It includes the full details of system calls including syscall parameters. Realistic attack scenarios with real software vulnerabilities and exploits are used. For each case, we created two sets of benign and adversary scenarios which are manually labeled for supervised machine-learning analysis. In addition, we present an algorithm to improve the data quality in the system provenance forensic analysis. We demonstrate the details of the dataset events and dependency analysis of our dataset cases.

97 MATHEMATICS AND COMPUTING↗