Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Theoretical and Experimental Evaluation of the Bond Strength Under Peeling Loads

Reliable applications of adhesively bonded joints require understanding of the stress distribution along the bond-line and the stresses that are responsible for the joint failure. To properly evaluate factors affecting peel strength, effects of defects such as voids on the stress distribution in the overlap region must be understood. In this work, the peel stress distribution in a single lap joint is derived using a strength of materials approach. The bonded joint is modeled as Euler-Bernoulli beams, bonded together with an adhesive. which is modeled as an elastic foundation which can resist both peel and shear stresses. It is found that for certain adhesive and adherend geometries and properties, a central void with the size up to 50 percent of the overlap length has negligible effect on the peak peel and shear stresses. To verify the solutions obtained from the model, the problem is solved again by using the finite element method and by treating the adherends and the adhesive as elastic materials. It is found that the model used in the analysis not only predicts the correct trend for the peel stress distribution but also gives rather surprisingly close results to that of the finite element analysis. It is also found that both shear and peel stresses can be responsible for the joint performance and when a void is introduced, both of these stresses can contribute to the joint failure as the void size increases. Acoustic emission (AE) activities of aluminum-adhesive-aluminum specimens with different void sizes were monitored. The AE ringdown counts and energy were very sensitive and decreased significantly with the void size. It was observed that the AE events were shifting towards the edge of the overlap where the maximum peeling and shearing stresses were occurring as the void size increased.

Nayeb-Hashemi, Hamid↗

Static Aeroelastic Modeling of a Sub-Scale Wind Tunnel Model with Novel Flap Concept

This paper examines the static aeroelastic modeling of a flexible wind tunnel model equipped with a novel control effector known as the Variable Camber Continuous Trailing Edge Flap (VCCTEF) system. The wind tunnel model is an approximately 10 percent sub-scale version of a wing designed to be equipped on a commerical transport aircraft such as the full-scale NASA Generic Transport Model (GTM). The structure of the model is made highly flexible such that a 10 percent of semi-span wing tip deflection is expected at a design lift condition, and a representation of the VCCTEF concept is incorporated on the model. Static aeroelastic modeling is conducted by using a representative single beam structural finite-element model coupled to a vortex-lattice aerodynamic model. The resulting aeroelastic model of the flexible wind tunnel model is compared against experimental wind tunnel test results from the actual model tested at the University of Washington Aeronautical Laboratory (UWAL). Comparison cases are made using reference and VICON measurements of VCCTEF flap deflections from the wind tunnel test data, and percent errors between the lift curve parameters are presented. The results show up to a maximum percent of error of <10% with regards to lift curve slope values between the aeroelastic model and the UWAL test data. The agreement of lift curve slope values from the aeroelastic model and experimental test results serves as validation for the coupled vortex-lattice finite-element static aeroelastic model.

Aeroelasticity↗

The relation between hard X-ray and transition-region line emission in solar flares

Observational evidence suggests that both the hard X-ray and ultraviolet emission from the impulsive phase of flares result from an electron beam. The results of model calculations that are consistent with this theory are presented. The impulsive phase is envisioned as occurring in many small magnetically confined loops, each of which maintains an electron beam for only a few seconds. This model successfully matches several observed aspects of the impulsive phase. The corona is heated to less than 2 million K, maximum enhanced emission occurs in lines formed near 100,000 K, and there is only slight enhancement between 100,000 and 2 million K. The slope of the observed relationship between hard X-ray and Ov 1371 A emission is also matched, but the relative emission is not. The calculations indicate that UV emission lines formed below a temperature of about 100,000 K will arise predominantly from the chromospheric region heated by the electron beam to transition region temperatures. Emission lines formed at higher temperatures will be produced in the transition region. This should be detectable in density-sensitive line ratios. To account successfully for the impulsive UV emission, the peak temperature in the impulsively heated loops must remain below about 2 million K. Thus the model implies that the impulsive heating takes place in different loops from the hotter gradual phase emission.

Mariska, J. T.↗

Experiment vs simulation RT WFNDEC 2014 benchmark: CIVA results

The French Atomic Energy Commission and Alternative Energies (CEA) has developed for years the CIVA software dedicated to simulation of NDE techniques such as Radiographic Testing (RT). RT modelling is achieved in CIVA using combination of a determinist approach based on ray tracing for transmission beam simulation and a Monte Carlo model for the scattered beam computation. Furthermore, CIVA includes various detectors models, in particular common x-ray films and a photostimulable phosphor plates. This communication presents the results obtained with the configurations proposed in the World Federation of NDEC 2014 RT modelling benchmark with the RT models implemented in the CIVA software.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-T-144: Analytical Closed Form Approximation for Carbon Ion Bragg Curves in Water

Purpose: Semi-empirical modeling is a powerful computational method in radiation dosimetry. A set of approximations exist for proton ion depth dose distribution (DDD) in water. However, the modeling is more complicated for carbon ions due to fragmentation. This study addresses this by providing and evaluating a new methodology for DDD modeling of carbon ions in water. Methods: The FLUKA, Monte Carlo (MC) general-purpose transport code was used for simulation of carbon DDDs for energies of 100–400 MeV in water as reference data model benchmarking. Based on Thomas Bortfeld’s closed form equation approximating proton Bragg Curves as a basis, we derived the critical constants for a beam of Carbon ions by applying models of radiation transport by Lee et. al. and Geiger to our simulated Carbon curves. We hypothesized that including a new exponential (κ) residual distance parameter to Bortfeld’s fluence reduction relation would improve DDD modeling for carbon ions. We are introducing an additional term to be added to Bortfeld’s equation to describe fragmentation tail. This term accounts for the pre-peak dose from nuclear fragments (NF). In the post peak region, the NF transport will be treated as new beams utilizing the Glauber model for interaction cross sections and the Abrasion- Ablation fragmentation model. Results: The carbon beam specific constants in the developed model were determined to be : p= 1.75, β=0.008 cm-1, γ=0.6, α=0.0007 cm MeV, σmono=0.08, and the new exponential parameter κ=0.55. This produced a close match for the plateau part of the curve (max deviation 6.37%). Conclusion: The derived semi-empirical model provides an accurate approximation of the MC simulated clinical carbon DDDs. This is the first direct semi-empirical simulation for the dosimetry of therapeutic carbon ions. The accurate modeling of the NF tail in the carbon DDD will provide key insight into distal edge dose deposition formation.

07 ISOTOPE AND RADIATION SOURCES↗

Elliptic and Hexadecapole Flow of Charged Hadrons in Au + Au Collisions at root s(NN)=GeV

Differential measurements of the elliptic (v{sub 2}) and hexadecapole (v{sub 4}) Fourier flow coefficients are reported for charged hadrons as a function of transverse momentum (p{sub T}) and collision centrality or number of participant nucleons (N{sub part}) for Au+Au collisions at {radical}s{sub NN} = 200 GeV. The v{sub 2,4} measurements at pseudorapidity |{eta}| {le} 0.35, obtained with four separate reaction-plane detectors positioned in the range 1.0 < |{eta}| < 3.9, show good agreement, indicating the absence of significant {Delta}{eta}-dependent nonflow correlations. Sizable values for v{sub 4}(p{sub T}) are observed with a ratio v{sub 4}(p{sub T},N{sub part})/v{sub 2}{sup 2}(p{sub T},N{sub part}) {approx} 0.8 for 50 {approx}< N{sub part} {approx}< 200, which is compatible with the combined effects of a finite viscosity and initial eccentricity fluctuations. For N{sub part} {approx}> 200 this ratio increases up to 1.7 in the most central collisions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Planck 2013 results. IV. Low Frequency Instrument beams and window functions

This paper presents the characterization of the in-flight beams, the beam window functions, and the associated uncertainties for the Planck Low Frequency Instrument (LFI). Knowledge of the beam profiles is necessary for determining the transfer function to go from the observed to the actual sky anisotropy power spectrum. The main beam distortions affect the beam window function, complicating the reconstruction of the anisotropy power spectrum at high multipoles, whereas the sidelobes affect the low and intermediate multipoles. The in-flight assessment of the LFI main beams relies on the measurements performed during Jupiter observations. By stacking the datafrom multiple Jupiter transits, the main beam profiles are measured down to-20 dB at 30 and 44 GHz, and down to-25 dB at 70 GHz. The main beam solid angles are determined to better than 0.2% at each LFI frequency band. The Planck pre-launch optical model is conveniently tuned to characterize the main beams independently of any noise effects. This approach provides an optical model whose beams fully reproduce the measurements in the main beam region, but also allows a description of the beams at power levels lower than can be achieved by the Jupiter measurements themselves. The agreement between the simulated beams and the measured beams is better than 1% at each LFI frequency band. The simulated beams are used for the computation of the window functions for the effective beams. The error budget for the window functions is estimated from both main beam and sidelobe contributions, and accounts for the radiometer bandshapes. The total uncertainties in the effective beam window functions are: 2% and 1.2% at 30 and 44 GHz, respectively (at &ell; &approx; 600), and 0.7% at 70 GHz (at &ell; &approx; 1000).

79 ASTRONOMY AND ASTROPHYSICS↗

The period-pulse-width distribution of pulsars and their division into three classes

The period-pulse-width (P-W) distribution of sample of 41 pulsars has been reanalyzed under two versions of a model where radiation is beamed from magnetic polar caps which are isotropically oriented with respect to the rotation axis of the neutron stars (IOPC models). It is found that neither IOPC model can explain the P-W distribution of the entire sample. Pulsars with simple unimodal (U) or complicated multimodal (M) pulse shapes show significantly different P-W distributions. Class M pulsars have a narrower P-W distribution than do class U pulsars and, taken separately, are compatible with either IOPC model. Class U pulsars divide into two subgroups, those with relatively narrower pulses (UN) and those with relatively wider pulses (UW), each of which is compatible with either IOPC model. One interpretation of these results is that the pulsars in classes UN, M, and UW have different intrinsic beam sizes, roughly in the ratios 1:2:4, respectively. The possible origins of the three classes are discussed in terms of the force-balance magnetosphere model (Roberts et al., 1972, 1973), where the differences may be attributed to different-mass neutron stars and the structure of the polar caps. An alternative interpretation is that the angle between the rotation and emission axes is not isotropically distributed, but can take only certain preferred values.

Roberts, D. H.↗

Persistence of collectivity in the low-lying states of 30,31 Na inside the 𝑁 = 20 island of inversion

Near the 𝛽-stability line, nuclei with magic numbers are expected to exhibit spherical ground states. However, mass measurements of neutron-rich nuclei near the 𝑁 = 20 island of inversion have indicated an excess in the binding energies. These results, together with subsequent spectroscopic studies and theoretical works, point to the structural evolution from normal configurations to intruder-deformed configurations characterized by particle-hole excitations across the shell gap. Despite evidence of intruder-dominant ground states for the 30,31 Na isotopes in the vicinity of 𝑁 = 20, a question remains as to whether the deformation persists into the ground-state bands beyond the first excited states. Here, in this work, we report on a heavy-ion inelastic scattering measurement performed with GRETINA, the TRIPLEX device, and the S800 spectrograph to study the low-lying excitations in neutron-rich 30,31 Na . The observed gamma rays for the (4 + ) → (3 + ), (3 + ) → 2$^+_{g.s.}$, and (4 + ) → 2$^+_{g.s.}$ decays in 30 Na and for the (7/2 + ) → (5/2 + ) and (5/2 + )→3/2$^+_{g.s.}$ decays in 31 Na were used to extract the reduced transition probabilities 𝐵⁡(𝐸⁢2↑). We report the first measurement of the 𝐵⁡(𝐸⁢2↑) between the 3/2$^+_{g.s.}$ and the (7/2 + ) states in 31 Na . The results from this study are compared to shell-model calculations, confirming the persistence of large collectivity in the low-lying excited states consistent with the formation of the well-deformed ground-state bands in 30,31 Na .

collective models↗

SU-F-J-148: A Collapsed Cone Algorithm Can Be Used for Quality Assurance for Monaco Treatment Plans for the MR-Linac

Purpose: Treatment plans for the MR-linac, calculated in Monaco v5.19, include direct simulation of the effects of the 1.5T B{sub 0}-field. We tested the feasibility of using a collapsed-cone (CC) algorithm in Oncentra, which does not account for effects of the B{sub 0}-field, as a fast online, independent 3D check of dose calculations. Methods: Treatment plans for six patients were generated in Monaco with a 6 MV FFF beam and the B{sub 0}-field. All plans were recalculated with a CC model of the same beam. Plans for the same patients were also generated in Monaco without the B{sub 0}-field. The mean dose (Dmean) and doses to 10% (D10%) and 90% (D90%) of the volume were determined, as percentages of the prescribed dose, for target volumes and OARs in each calculated dose distribution. Student’s t-tests between paired parameters from Monaco plans and corresponding CC calculations were performed. Results: Figure 1 shows an example of the difference between dose distributions calculated in Monaco, with the B{sub 0}-field, and the CC algorithm. Figure 2 shows distributions of (absolute) difference between parameters for Monaco plans, with the B{sub 0}-field, and CC calculations. The Dmean and D90% values for the CTVs and PTVs were significantly different, but differences in dose distributions arose predominantly at the edges of the target volumes. Inclusion of the B{sub 0}-field had little effect on agreement of the Dmean values, as illustrated by Figure 3, nor on agreement of the D10% and D90% values. Conclusion: Dose distributions recalculated with a CC algorithm show good agreement with those calculated with Monaco, for plans both with and without the B{sub 0}-field, indicating that the CC algorithm could be used to check online treatment planning for the MRlinac. Agreement for a wider range of treatment sites, and the feasibility of using the γ-test as a simple pass/fail criterion, will be investigated.

60 APPLIED LIFE SCIENCES↗

Injection of Large Transverse Emittance EBIS Beams in Booster

During the commissioning of EBIS beams in Booster in November 2010 and in April, May and June 2011, it was found that the transverse emittances of the EBIS beams just upstream of Booster were much larger than expected. Beam emittances of 11π mm milliradians had been expected, but numbers 3 to 4 times larger were measured. Here and throughout this note the beam emittance, πϵ 0 , is taken to be the area of the smallest ellipse that contains 95% of the beam. We call this smallest ellipse the beam ellipse. If the beam distribution is gaussian, the rms emittance of the distribution is very nearly one sixth the area of the beam ellipse. The normalized rms emittance is the rms emittance times the relativistic factor βγ = 0.06564. This amounts to 0.12π mm milliradians for the 11π mm milliradian beam ellipse. In we modeled the injection and turn-by-turn evolution of an 11π mm milliradian beam ellipse in the horizontal plane in Booster. It was shown that with the present injection system, up to 4 turns of this beam could be injected and stored in Booster without loss. In the present note we extend this analysis to the injection of larger emittance beams. We consider only the emittance in the horizontal plane. Emittance in the vertical plane and the effects of dispersion are treated in.

43 PARTICLE ACCELERATORS↗

Laser beam scattering on an inhomogeneous ensemble of elliptical discs modelling red blood cells in an ectacytometer

We have theoretically studied the effect of difference in particle shapes on the appearance of the diffraction pattern, which arises in the scattering of a laser beam on a dilute suspension of erythrocytes in an ectacytometer. We have proposed data processing algorithms allowing one to estimate the red blood cell shape parameter variance under conditions of laser ectacytometry. The conclusions of the theoretical analysis are verified experimentally. (laser methods in biology)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine learning surrogate for charged particle beam dynamics with space charge based on a recurrent neural network with aleatoric uncertainty

In this work, we develop a machine learning (ML) model with aleatoric uncertainty for the low energy beam transport (LEBT) region of the LANSCE linear accelerator in which we model the transport of a space-charge-dominated 750 keV proton beam through a lattice of 22 quadrupole magnets. Our ML model is developed based on data generated by a Kapchinsky–Vladimirsky (KV) envelope model of beam transport. We show that a recurrent neural network can be used as a dynamical surrogate model for fast prediction of the LEBT beam envelope. Furthermore, we endow the model with the prediction of aleatoric uncertainty and compare three different approaches. We demonstrate that the ML-based uncertainty quantification models are well calibrated and produce good estimates of the regions where the model is less certain about its predictions. This ML framework is a necessary step in the development of a real-time virtual diagnostic tool with uncertainty quantification that can be integrated into more complex downstream tasks (e.g., adaptive control or learning flexible control policies via reinforcement learning) for improved efficiency in beam operations. In future work, we plan to expand on this preliminary study by considering more realistic envelope models that include longitudinal momentum spread and dispersive effects in bending magnets, as well as particle tracking codes with 3D space charge (such as and ). Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Maneuver simulations of flexible spacecraft by solving TPBVP

The optimal control of large angle rapid maneuvers and vibrations of a Shuttle mast reflector system is considered. The nonlinear equations of motion are formulated by using Lagrange's formula, with the mast modeled as a continuous beam. The nonlinear terms in the equations come from the coupling between the angular velocities, the modal coordinates, and the modal rates. Pontryagin's Maximum Principle is applied to the slewing problem, to derive the necessary conditions for the optimal controls, which are bounded by given saturation levels. The resulting two point boundary value problem (TPBVP) is then solved by using the quasilinearization algorithm and the method of particular solutions. In the numerical simulations, the structural parameters and the control limits from the Spacecraft Control Lab Experiment (SCOLE) are used. In the 2-D case, only the motion in the plane of an Earth orbit or the single axis slewing motion is discussed. In the 3-D slewing, the mast is modeled as a continuous beam subjected to 3-D deformations. The numerical results for both the linearized system and the nonlinear system are presented to compare the differences in their time response.

Bainum, Peter M.↗

SU-E-T-110: Development of An Independent, Monte Carlo, Dose Calculation, Quality Assurance Tool for Clinical Trials

Purpose: To develop a comprehensive end-to-end test for Varian's TrueBeam linear accelerator for head and neck IMRT using a custom phantom designed to utilize multiple dosimetry devices. Purpose: To commission a multiple-source Monte Carlo model of Elekta linear accelerator beams of nominal energies 6MV and 10MV. Methods: A three source, Monte Carlo model of Elekta 6 and 10MV therapeutic x-ray beams was developed. Energy spectra of two photon sources corresponding to primary photons created in the target and scattered photons originating in the linear accelerator head were determined by an optimization process that fit the relative fluence of 0.25 MeV energy bins to the product of Fatigue-Life and Fermi functions to match calculated percent depth dose (PDD) data with that measured in a water tank for a 10x10cm2 field. Off-axis effects were modeled by a 3rd degree polynomial used to describe the off-axis half-value layer as a function of off-axis angle and fitting the off-axis fluence to a piecewise linear function to match calculated dose profiles with measured dose profiles for a 40×40cm2 field. The model was validated by comparing calculated PDDs and dose profiles for field sizes ranging from 3×3cm2 to 30×30cm2 to those obtained from measurements. A benchmarking study compared calculated data to measurements for IMRT plans delivered to anthropomorphic phantoms. Results: Along the central axis of the beam 99.6% and 99.7% of all data passed the 2%/2mm gamma criterion for 6 and 10MV models, respectively. Dose profiles at depths of dmax, through 25cm agreed with measured data for 99.4% and 99.6% of data tested for 6 and 10MV models, respectively. A comparison of calculated dose to film measurement in a head and neck phantom showed an average of 85.3% and 90.5% of pixels passing a 3%/2mm gamma criterion for 6 and 10MV models respectively. Conclusion: A Monte Carlo multiple-source model for Elekta 6 and 10MV therapeutic x-ray beams has been developed as a quality assurance tool for clinical trials.

60 APPLIED LIFE SCIENCES↗

SU-C-303-06: Treatment Planning Study for Non-Invasive Cardiac Arrhythmia Ablation with Scanned Carbon Ions in An Animal Model

Purpose: Scanned carbon ion beams might offer a non-invasive alternative treatment for cardiac arrhythmia, which are a major health-burden. We studied the feasibility of this procedure in an animal model. The underlying treatment planning and motion mitigation strategies will be presented. Methods: The study was carried out in 15 pigs, randomly distributed to 3 target groups: atrioventricular node (AVN, 8 animals with 25, 40, and 55 Gy target dose), left ventricular free-wall (LV, 4 animals with 40 Gy) and superior pulmonary vein (SPV, 3 animals with 40 Gy). Breathing motion was suppressed by repeated enforced breathholds at end exhale. Cardiac motion was mitigated by an inhomogeneous rescanning scheme with up to 15 rescans. The treatment planning was performed using the GSI in-house software TRiP4D on cardiac-gated 4DCTs, applying a range-considering ITV based on an extended CTV. For AVN and SPV isotropic 5 mm margins were applied to the CTV, while for the LV 2mm+2% range margins were used. The opposing fields for AVN and LV targets were optimized independently (SFUD), while SPV treatments were optimized as IMPT deliveries, including dose restrictions to the radiosensitive AVN. Results: Median value of D{sub 95} over all rescanning simulations was 99.1% (AVN), 98.0% (SPV) and 98.3% (LV) for the CTV and 94.7% (AVN) and 92.7% (SPV) for the PTV, respectively. The median D{sub 5}-D{sub 95} was improved with rescanning compared to unmitigated delivery from 13.3 to 6.5% (CTV) and from 23.4 to 11.6% (PTV). ICRP dose limits for aorta, trachea, esophagus and skin were respected. The maximal dose in the coronary arteries was limited to 30 Gy. Conclusion: We demonstrated the feasibility of a homogeneous dose delivery to different cardiac structures in a porcine model using a time-optimized inhomogeneous rescanning scheme. The presented treatment planning strategies were applied in a pig study with the analysis ongoing. Funding: This work was supported in part by the Helmholtz Association, the American Heart Association Midwest Affiliate Postdoctoral Fellowship Grant, the Mayo Clinic Foundation, and the Goldsmith Foundation.

60 APPLIED LIFE SCIENCES↗

Surface Production of Negative Ions by Positive Ions and Atoms in the Electron Suppressor Region

A simple model of the production of negative ions by positive ions and atoms from the source plasma striking a caesiated surface is presented. The model combines calculated flux rates for the ions and atoms at a surface with negative ion yields to determine the surface production rates. The model takes into account the relative potential between the plasma and the electron suppressor in calculating the surface production rates. By making the assumption that the surface production rates can be directly compared with the extracted beam current then the model is compared with data where the beam current has been measured as a function of electron suppressor bias and knowledge of the plasma parameters of the source also exists. At high bias voltages relative to the plasma potential only volume produced negative ions can be extracted as negative ions created on the surface cannot cross the sheath. The model reproduces features of the ion current dependence on electron suppressor bias. At high bias voltages where negative ions cannot leave the surface there is still an enhancement of the non-caesiated performance which may be attributed to volume production enhancement due to the presence of caesium in the plasma. This has implications for the replacement of caesium with other low work function materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Of narrow lines and beaming in the strong-field SSC emission model

The synchrotron self-Compton (SSC) emission model for gamma-ray bursts is capable of producing narrow line features for a variety of modelled field strengths, primary electron injection distributions and burst luminosities. Multiple resonant scattering with synchrotron continuum photons efficiently traps and cools pairs in the ground state to an average energy where the Compton energy loss rate is zero. Annihilation between pairs in these cooled distributions can be very efficient. For isotropic injection of primary electrons, there is an anti-correlation of the intensity of the angular-binned emission between the portions of the continuum spectrum below the cyclotron peak and above the annihilation line feature. Small-angle emission dominates the continuum above the annihilation line feature and is smooth through the line up to the pair production cut-off, which can be above several MeV for small enough angles. The angle-averaged annihilation line is made of components which can have peak emission centered at energies away from 511 keV, due to Doppler shifting. For beamed injection,the annihilation line breaks up into relatively narrow components in the angular emission, which sum into a broad feature in the angle-averaged emission.

Preece, Robert D.↗