Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Waste Transfer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

The Effect of Environmental Relative Humidity on Carbonation and Oxidation in a Cementitious Waste Form - 18448

Cementitious material has been developed and used for the nuclear waste disposal. Cast Stone, a type of cementitious waste form, is considered for solidification and immobilization of part of low activity radioactive waste (LAW) at DOE Hanford Site in Richland, WA. During its life cycle, the waste form, which is produced from Portland cement, fly ash, blast furnace slag and liquid waste, is subject to reaction with carbon dioxide and oxygen, both in gaseous and dissolved form. The reactions may alter the physical and chemical properties of the waste form and thus change its retention ability for the radionuclides. Therefore, understanding the rate and the impact of oxidation and carbonation in the material is important for projecting the long-term performance of Cast Stone. However, the rate of carbonation and oxidation in Cast Stone closely depends on the moisture content in the material, which varies largely with the environmental relative humidity (RH). In this study, experiments are carried out to study the effect of environmental relative humidity on the carbonation and oxidation rate as well as the leaching of the constituents from Cast Stone. Cast Stone samples doped with Cr as a reaction indicator are aged for 16 to 32 weeks under N{sub 2}, air, and 2% CO{sub 2} (in nitrogen) environments with various relative humidities (15%, 40%, 68%, 100%). After aging, samples were tested for the pH-dependent leaching (EPA Method 1313) and mass transfer rate under diffusion-controlled leaching (EPA Method 1315) of constituents. The progress of the carbonation was measured for each condition to determine the rate of carbonation front ingress. The results show that environmental relative humidity strongly influences carbonation and oxidation in Cast Stone; however, the impact is different for the rate of reaction and for the extent of reactions. The former refers to the rate at which the reaction front ingresses, while the latter refers to the fraction of the material reacted. For both carbonation and oxidation, the largest impact of the reactions at the exposure surface is observed at intermediate relative humidity (68%). However, for carbonation, the reaction front evolves more rapidly under drier conditions, with the highest rate observed at 15% RH. As a result, carbonation and oxidation have different degree of impact on the leaching behavior of Cast Stone samples aged under various relative humidities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quick-start of full-scale anaerobic digestion (AD) using aeration

Highlights: • A fast, and original, start up procedure for anaerobic digestors has been applied at full scale. • The development of a methanogenic culture has been documented using fluorescent in situ hybridization. • The technique can be widely applied. - Abstract: A conventional 1300 m{sup 3} continuously stirred anaerobic tank reactor at the city of Boden, north Sweden, which was receiving a feed of both sewage sludge and food waste, was put out of operation due to the build-up of a float phase. The reactor was emptied and cleaned. At start-up there was no methanogenic sludge available, so an unconventional start-up procedure was applied: The reactor was rapidly (8 days with 1200 kg of total solids (TS) added daily) filled with thickened, and slightly acidic sewage sludge, showing only slight methane generation, which was subsequently heated to 55 °C. Then compressed air was blown into the digester and within a month a fully functional methanogenic culture was established. The transfer from acidogenic to methanogenic conditions happened in about one week. As a start-up technique this is fast and cost efficient, it only requires the access of a compressor, electricity and a source of air. In total, about 16 tonnes of oxygen were used. It is proposed that this method may also be used as an operational amendment technique, should a reactor tend to acidify.

54 ENVIRONMENTAL SCIENCES↗

Deep Bed Adsorption Testing using Silver-Functionalized Aerogel

Nuclear fission results in the production of fission products and activation products, some of which tend to be volatile during used fuel reprocessing and evolve in gaseous species into the reprocessing facility off-gas systems. Analyses have shown that I129, due to its radioactivity, high potential mobility in the environment, and high longevity (half life of 15.7 million years), can require control efficiencies of up to 1,000x or higher to meet regulatory emission limits. Two Aerogel sorption tests that have been performed this fiscal year. The maximum iodine decontamination factor (DF) was measured to be over 10,000, above the 1,000-10,000 target DF range. The mass transfer zone may be as short as 0.5 inches under the sorption conditions of the first test. Only a small fraction of the iodine sorbed on Bed 1 was desorbed during the purge periods. The silver-functionalized Aerogel appears to have potential to be a very effective and efficient iodine sorbent.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ediesel: Diesel Additive production from ethanol and bio-diesel coproducts

This project has focused on supporting and expanding the U.S. ethanol industry by developing new conversion routes and products from ethanol and the byproducts made in ethanol fermentation. The work is relevant to the DOE program goals of developing high-margin chemical products in the biorefinery to economically support large-scale biofuel production. The higher alcohols from condensation of ethanol, alkylated amine compounds made by electrocatalytic alkyation, and fusel alcohols produced by modified fermentation microorganisms are all existing or potentially large-scale commodity or specialty chemicals with well-defined uses in industry. The formation of higher alcohols from ethanol in the condensed phase developed several catalysts, first in stirred batch autoclave reactors and then in a continuous flow reactor system, to achieve significant yields of n-butanol and higher alcohols. The best selectivity to higher alcohols exceeded 80% of theoretical at ethanol conversions of 30-40%. From the laboratory experiments and analysis of the phase equilibria of the species involved, a process concept was generated and simulated in AspenPlus to determine the specifications of the various equipment involved in the process. Results show that for the conversion and selectivity described above, the required n-butanol selling price of ~$1.60/kg is in the range of current n-butanol selling price in the marketplace. Several additional permutations of the process, along with evaluation of higher conversion and selectivities to desired alcohol products, showed that the production of n-butanol from ethanol should be competitive in the marketplace as the science and engineering behind the process improves with continued development. A second aspect of the project focused on producing fusel alcohols in increased quantities during ethanol fermentation. Fusel alcohols, which are composed primarily of isoamyl alcohol and minor quantities of C3-C6 alcohols, have potential as higher value feed stocks for specialty chemical production. Several strains of yeast were evaluated for fusel alcohol production, and the most efficient process for separating and purifying fusel alcohols was developed from both experiments and simulation. Finally, model fusel alcohol mixtures were subjected to condensation reactions with ethanol to prepare higher alcohols that again have potential for specialty chemical or solvent applications. In this preliminary work, measurable quantities of several species were observed, including some species that were previously unknown or uncharacterized in the literature. The third aspect of the project involved the electrocatalytic alkylation of amines with alcohols to form alkyl amines. Ethanol has been demonstrated to serve as an effective ethyl group transfer agent to the nitrogen centers of amines, a reaction with only water as a byproduct. Mild reaction conditions (60 °C, aqueous solution) are enabled by the novel use of simple, undivided electrochemical cell reactors that include long-lived, low cost catalytic electrodes. Direct polyalkylation of ammonia and isolation of the resulting triethylamine product was readily achieved in high yield. Though classical high temperature and pressure industrial scale alkylations reactions will likely continue to be used for production of simple product such as triethylamine, this approach has opened the door to the low cost, low waste use of ethanol and related primary and secondary alcohols to alkylate more delicate amines that were heretofore difficult to synthesize.

02 PETROLEUM↗

Automation of environmental compliance data acquisition and management - 15267

Regulatory sampling for environmental compliance at the Savannah River Site (SRS), Aiken, South Carolina employs several different types of sampling techniques at various sampling frequencies. These sampling events result in the collection of large quantities of data and generate substantial data-related documents. The use of paper documents resulted in the need for manual input of data collected in the field and distribution of documents from one group to the next. To efficiently and effectively manage the extensive amounts of data and documents, elements of the sampling process were automated using hand-held field tablets and an electronic application. The tablets allow for easier distribution of sampling documents, and the application allows for digital transfer of sampling information and collected field data. The transition to automated data acquisition and management has resulted in a more efficient and reliable manner for conducting business at SRS. This system benefits numerous organizations at SRS by utilizing a centralized database for efficient management of all environmental data collected. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Handling and Treatment of Sodium-Potassium Alloy (NaK) after the Loss of Key Personnel - 19002

In September 2010, during cleanup and removal efforts associated with a glovebox containing a sodium-potassium alloy (NaK) cooling system, a NaK reaction event occurred. Near the end of the evolution, which was at a Materials and Fuels Complex (MFC) research facility at the Idaho National Laboratory, a 2 to 3-ounce sample of NaK was being transferred from a metal can to a polyethylene bottle so it could be sent to the disposal outlet for verification analysis. During the transfer, a reaction of the NaK with ambient air was observed in both the metal can and sample container. The potential for a reaction was identified during the planning of this activity and mitigating steps were included in the procedures. In response, the two containers were flooded with argon, closed, and observed overnight. No additional reaction was noted. The sample container and metal can were packaged into a 10-gallon drum and transferred to a permitted storage location pending disposal. While the other containers generated from the deactivation and decommissioning activity were sent off-site for disposal, the 10-gal drum remained due to concerns by a staff specialist that the material could contain potassium superoxide (KO{sub 2}) as a result of the reaction event. The intent at that time was to treat the NaK in a Resource Conservation and Recovery Act (RCRA)-permitted treatment facility at MFC, instead of sending it off-site for disposal. The container was labeled, inspected, and managed as a hazardous waste. Due to the complexities associated with safely handling and treating NaK and KO{sub 2}, the container remained in storage. Treatment and disposal of the NaK and KO{sub 2} container was revisited in 2016, when researchers and chemists were consulted regarding the potential for superoxide formation and the best means to safely store and treat the container. The facility came to realize that due to the retirements of key personnel, it needed to provide current employees operational experience with the handling and treatment of NaK. An outside company was identified and contracted to provide training and consulting services. Several Battelle Energy Alliance, Inc. (BEA) personnel then attended an alkali metals safety training class. The training course provided participants with classroom and hands-on instruction associated with: - Hazards associated with handling and using sodium and NaK; - Proper personal protection equipment, spill control techniques, and first aid; - Common design approaches for buildings, systems, and equipment used to contain sodium and NaK; - What to expect in the event of a water reaction and how to respond; - How to properly prepare for a fire and contain/extinguish small metal fires; - A hands-on demonstration of NaK reaction and controls. Following the training, a procedure was developed to open the container, and inspect and treat the NaK. In June 2017, facility operations personnel successfully completed the inspection and treatment of the NaK drum, eliminating the legacy liability. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Phase 2 Methyl Iodide Deep-Bed Adsorption Tests

Nuclear fission produces fission products (FPs) and activation products, including iodine-129, which could evolve into used fuel reprocessing facility off-gas systems, and could require off-gas control to limit air emissions to levels within acceptable emission limits. Research, demonstrations, and some reprocessing plant experience have indicated that diatomic iodine can be captured with efficiencies high enough to meet regulatory requirements. Research on the capture of organic iodides has also been performed, but to a lesser extent. Several questions remain open regarding the capture of iodine bound in organic compounds. Deep-bed methyl iodide adsorption testing has progressed according to a multi-laboratory methyl iodide adsorption test plan. This report summarizes the second phase of methyl iodide adsorption work performed according to this test plan using the deep-bed iodine adsorption test system at the Idaho National Laboratory (INL), performed during the second half of Fiscal Year (FY) 2014. Test results continue to show that methyl iodide adsorption using AgZ can achieve total iodine decontamination factors (DFs, ratios of uncontrolled and controlled total iodine levels) above 1,000, until breakthrough occurred. However, mass transfer zone depths are deeper for methyl iodide adsorption compared to diatomic iodine (I2) adsorption. Methyl iodide DFs for the Ag Aerogel test adsorption efficiencies were less than 1,000, and the methyl iodide mass transfer zone depth exceeded 8 inches. Additional deep-bed testing and analyses are recommended to (a) expand the data base for methyl iodide adsorption under various conditions specified in the methyl iodide test plan, and (b) provide more data for evaluating organic iodide reactions and reaction byproducts for different potential adsorption conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Tank 9h Salt Dissolution Batch 2C In Support of Tank Closure Cesium Removal (TCCR) 1A Batch 2 Preparations

Savannah River Mission Completion (SRMC) is currently preparing the second batch of material to be processed through the Tank Closure Cesium Removal (TCCR) 1A system. The feed for TCCR 1A consists of dissolved saltcake from Tank 9H. The third batch of salt to make up processing Batch 2 (Batch 2C) has recently been dissolved in Tank 9H and transferred to Tank 10H where it was composited with the first part of the batch (Batches 2A and 2B) in preparation for processing through the TCCR 1A unit. Savannah River National Laboratory (SRNL) received samples from the recent batch (2C) of dissolved salt for characterization.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Robotic Solutions for Remote Access and Retrieval of High-Level Radioactive Waste - 19544

This paper describes the ongoing development of robotic solutions for accessing and retrieving high-level radioactive waste from underground storage bins as part of the Calcine Retrieval Project at the INL Site. The waste is in the form of a solid powder, referred to as calcine, stored in a set of stainless steel bins within an underground concrete vault. Due to the radiation field produced by the calcine, all operations must be performed remotely. The Calcine Retrieval Project is currently carrying out proof-of-concept testing of methods for the various stages of calcine retrieval. The bins were designed with no means for access, so retrieval operations will require welding access riser pipes to the bins, followed by cutting through the bin walls from within the risers. These tasks are complicated by the fact that four of the risers must be placed off center on a domed surface, resulting in a weld joint that is curved and tilted relative to the riser axis. The Access Riser Connection robot is being developed to perform these operations using interchangeable welding and plasma cutting attachments. The majority of the calcine will be removed using a vacuum system and pneumatically transferred to storage. This system is not described in this paper. However, the bins contain several internal features that are expected to retain calcine, most notably circumferential stiffening rings on the walls and radial ribs on the floors. One of the solutions being developed for the task of retrieving this residual calcine is a vacuum crawler, a wheeled robot using vacuum to adhere to the interior walls of the bins. The vacuum crawler would use a separate vacuum system to remove residual calcine or would use compressed air to move calcine to a location from which it can be retrieved more easily. While comparable welding and wall-climbing robots have been developed before, this particular application has several constraints that are not satisfied by existing systems. For this reason, both the access riser welder and the vacuum crawler, although still under development, may be of interest to other projects faced with similar constraints. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

First-Principles-Based Computational Study on Nucleation and Growth Mechanisms of U on Mo(110) Surface Solvated in an Eutectic LiCl-KCl Molten Salt

In nuclear engineering and industry electrochemical methods have been intensively employed in pyro-processing technology to recycle used nuclear fuels for substantial alleviation of the concern with the safe treatment of high-level radioactive nuclear wastes. Pyro-processing is based on sequential electrochemical reactions at high temperature (typically above 700 K at ambient pressure) to enhance the efficiency for decoupling nuclear fuels from unfavorable fission fragments. Using a molten salt in electrorefining process, at which actinides can be selectively deposited in solid cathode from ionic states, gives several advantages over an aqueous solution: higher thermal conductivity (it is liquid phase at high temperature, molten salt plays a role as medium at high temperature over 773 K in electrochemical reaction, lower kinetic barrier in ionic diffusion mobility and better stability against undesired side reactions with radioactive materials. Therefore, the volume of high-level nuclear wastes to be, otherwise, disposed into secured sites is dramatically reduced. Most of all it conforms to nuclear non-proliferation treaty. Electrochemical reactions in a molten salt medium are, however, much more complicated than in aqueous solution rendering the accurate understanding of thermodynamic and kinetic properties formidably challenging. It is represented by extensive researches in experiments and computations to identify underlying mechanisms on how U and other fission fragments behave in the electrorefining system. Regardless of the researches there is a general agreement that the initial stage of the nucleation and growth process of the U deposit is critical for determining the properties of final product and the electrorefining efficiency. In spite of the focused studies it still remains unclear. Theoretical and computational researches have been often carried out with various empirical parameter for interatomic potential energy, which are unknown variables until numerical fits to experimental measurements or just assumption is made. Thus, empirical simulations sometimes predicted outcomes are inconsistent depending on materials of interest with experimental measurements. This may be largely because the accuracy of an empirical interatomic potential energy models critically depends on the input parameters and thus, can be limited in transferability of the results. Furthermore, it may be devoid of fundamental physics or chemistry. This situation requires special caution when an electrorefining system is studied to recycle spent nuclear fuels because of the extreme difficulty in reliable acquisition of thermodynamic and kinetic data from direct experimental measurements. In this presentation, we extensively utilized first principles density functional theory (DFT) calculations and ab-initio molecular dynamic (AIMD) simulations to figure out underlying mechanisms of the initial stage of nucleation and growth behaviors of U on Mo(110) surface in a eutectic LiCl-KCl molten salt at T = 773 K. To rigorously investigate the effect of the molten salt electrolyte we compared the results with those calculated under vacuum condition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Independent Confirmatory Survey Summary and Results for the Enrico Fermi Atomic Power Plant, Unit 1, Newport, Michigan (Final Report No. 2)

The Enrico Fermi Atomic Power Plant, Unit 1 (Fermi 1) was a fast breeder reactor design that was cooled by sodium and operated at essentially atmospheric pressure. On May 10, 1963, the Atomic Energy Commission (AEC) granted an operating license, DPR-9, to the Power Reactor Development Company (PRDC), a consortium specifically formed to own and operate a nuclear reactor at the Fermi 1 site. The reactor was designed for a maximum capability of 430 megawatts (MW); however, the maximum reactor power with the first core loading (Core A) was 200 MW. The primary system was filled with sodium in December 1960 and criticality was achieved in August 1963. The reactor was tested at low power during the first couple years of operation. Power ascension testing above 1 MW commenced in December 1965 immediately following the receipt of a high-power operating license. In October 1966 during power ascension, zirconium plates at the bottom of the reactor vessel became loose and blocked sodium coolant flow to some fuel subassemblies. Two subassemblies started to melt and the reactor was manually shut down. No abnormal releases to the environment occurred. Forty-two months later after the cause had been determined, cleanup completed, and the fuel replaced, Fermi 1 was restarted. However, in November 1972, PRDC made the decision to decommission Fermi 1 as the core was approaching its burn-up limit. The fuel and blanket subassemblies were shipped off-site in 1973. Following that, the secondary sodium system was drained and sent off-site. The radioactive primary sodium was stored on-site in storage tanks and 55 gallon (gal) drums until it was shipped off-site in 1984. The initial decommissioning of Fermi 1 was completed in 1975. Effective January 23, 1976, DPR-9 was transferred to the Detroit Edison Company (DTE) as a 'possession only' license (DTE 2010a). This report details the confirmatory activities performed during the second Oak Ridge Institute for Science and Education (ORISE) site visit to Fermi 1 in November 2010. The survey was strategically planned during a Unit 2 (Fermi 2) outage to take advantage of decreased radiation levels that were observed and attributed to Fermi 2 from the operating unit during the first site visit. However, during the second visit there were elevated radiation levels observed and attributed to the partially dismantled Fermi 1 reactor vessel and a waste storage box located on the 3rd floor of the Fermi 1 Turbine Building. Confirmatory surveys (unshielded) performed directly in the line of sight of these areas were affected. The objective of the confirmatory survey was to verify that the final radiological conditions were accurately and adequately described in Final Status Survey (FSS) documentation, relative to the established release criteria. This objective was achieved by performing document reviews, as well as independent measurements and sampling. Specifically, documentation of the planning, implementation, and results of the FSS were evaluated; side-by-side FSS measurement and source comparisons were performed; site areas were evaluated relative to appropriate FSS classification; and areas were assessed for residual, undocumented contamination.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Assessment of the impact of TOA partitioning on DWPF off-gas flammability

An assessment has been made to evaluate the impact on the DWPF melter off-gas flammability of increasing the amount of TOA in the current solvent used in the Modular Caustic-Side Solvent Extraction Process Unit (MCU) process. The results of this study showed that the concentrations of nonvolatile carbon of the current solvent limit (150 ppm) in the Slurry Mix Evaporator (SME) product would be about 7% higher and the nonvolatile hydrogen would be 2% higher than the actual current solvent (126 ppm) with an addition of up to 3 ppm of TOA when the concentration of Isopar L in the effluent transfer is controlled below 87 ppm and the volume of MCU effluent transfer to DWPF is limited to 15,000 gallons per Sludge Receipt and Adjustment Tank (SRAT)/SME cycle. Therefore, the DWPF melter off-gas flammability assessment is conservative for up to an additional 3 ppm of TOA in the effluent based on these assumptions. This report documents the calculations performed to reach this conclusion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Supercritical CO2 Recuperators, Presented at The ASME Turbo Expo 2017, June 29, 2017, by Dr. John Kelly, President, Altex Technologies Corporation

Closed Brayton super-critical CO2 power cycles are well suited to waste heat bottoming cycles, due to their increased efficiency and compactness, relative to Rankine steam bottoming cycles. Since waste heat applications would be retrofits, the power system compactness is important. To achieve high efficiency, these power cycles require high pressure recuperative type heat exchangers, of substantial heat duty. Current Printed Circuit Heat Exchangers (PCHE), originally developed for high pressure gas and oil applications, can be used as recuperators, but costs are higher than desired. Altex is developing a purpose-built high pressure and effectiveness recuperator to provide the reliability, compactness, performance and pressure capability of current recuperators, but at a reduced cost. The High Effectiveness Low Cost (HELC) recuperative heat exchanger design yields volume and weight metrics of .0024 m3/UA and 10.2 kg/UA, which are 4% and 77.3% below recuperator target metrics, respectively. A 50 kW test article was designed and fabricated. Performance tests on water and oil showed that the HELC design model could predict heat transfer, to within 10% of the measured value. This model was then used to project HELC performance, when operating on supercritical CO2. Besides performance tests, the test article was hydrostatically tested, for integrity at up to 4,000 psi pressure. At these conditions, some distortion of channels was encountered. To mitigate distortion, the inserts were redesigned and these results were used to project the cost of 500 kW and 5,083 kW HELC units. The cost metric for the 5,083 kW unit was determined to be $1,349/UA, which is 10% lower than the recuperator desired cost metric desired target of $1,500/UA. In addition, the 5,083 kW unit HELC cost of $61.09/kW is 33.6% lower than the $92/kW estimated cost for a PCHE. Hydrostatic pressure tests, at up to 4,000psi, showed that the unit did not leak. However, channels were distorted at this pressure differential. Design updates to minimize stress concentrations and distortion were prepared and analyzed, to show that distortion could be controlled, but to date tests have not been run to prove the design. Project results show the potential of the HELC approach, but more work is required to confirm this potential, at the larger scales of interest.

14 SOLAR ENERGY↗

High Effectiveness, Compact, High Pressure and Low-Cost Recuperator, Presented at The Fifth International Symposium – Super-Critical CO2 Power Cycles, San Antonio, Texas, March 28-31, 2016, by Dr. John Kelly, President, Altex Technologies Corporation

Closed Brayton super-critical CO2 power cycles are well suited to waste heat bottoming cycles, due to their increased efficiency and compactness, relative to Rankine steam bottoming cycles. Since waste heat applications would be retrofits, the power system compactness is important. To achieve high efficiency, these power cycles require high pressure recuperative type heat exchangers, of substantial heat duty. Current Printed Circuit Heat Exchangers (PCHE), originally developed for high pressure gas and oil applications, can be used as recuperators, but costs are higher than desired. Altex is developing a purpose-built high pressure and effectiveness recuperator to provide the reliability, compactness, performance and pressure capability of current recuperators, but at a reduced cost. The High Effectiveness Low Cost (HELC) recuperative heat exchanger design yields volume and weight metrics of .0024 m3/UA and 10.2 kg/UA, which are 4% and 77.3% below recuperator target metrics, respectively. A 50 kW test article was designed and fabricated. Performance tests on water and oil showed that the HELC design model could predict heat transfer, to within 10% of the measured value. This model was then used to project HELC performance, when operating on supercritical CO2. Besides performance tests, the test article was hydrostatically tested, for integrity at up to 4,000 psi pressure. At these conditions, some distortion of channels was encountered. To mitigate distortion, the inserts were redesigned and these results were used to project the cost of 500 kW and 5,083 kW HELC units. The cost metric for the 5,083 kW unit was determined to be $1,349/UA, which is 10% lower than the recuperator desired cost metric desired target of $1,500/UA. In addition, the 5,083 kW unit HELC cost of $61.09/kW is 33.6% lower than the $92/kW estimated cost for a PCHE. Hydrostatic pressure tests, at up to 4,000psi, showed that the unit did not leak. However, channels were distorted at this pressure differential. Design updates to minimize stress concentrations and distortion were prepared and analyzed, to show that distortion could be controlled, but to date tests have not been run to prove the design. Project results show the potential of the HELC approach, but more work is required to confirm this potential, at the larger scales of interest.

14 SOLAR ENERGY↗

The feasibility study of hot cell decontamination by the PFC spray method

The characteristics of per-fluorocarbon compounds (PFC) are colorless, non-toxic, easily vaporized and nonflammable. Also, some of them are liquids of a high density, low surface tension, low latent heat and low specific heat. These particular chemical and physical properties of fluoro-organic compounds permit their use in very different fields such as electronics, medicine, tribology, nuclear and material science. The Sonatol process was developed under a contract with the DOE. The Sonatol process uses an ultrasonic agitation in a PFC solution that contains a fluorinated surfactant to remove radioactive particles from surfaces. Filtering the suspended particles allows the solutions to be reused indefinitely. They applied the Sonatol process to the decontamination of a heterogeneous legacy Pu-238 waste that exhibited an excessive hydrogen gas generation, which prevents a transportation of such a waste to a Waste Isolation Pilot Plant. Korea Atomic Energy Research Institute (KAERI) is developing dry decontamination technologies applicable to a decontamination of a highly radioactive area loosely contaminated with radioactive particles. This contamination has occurred as a result of an examination of a post-irradiated material or the development of the DUPIC process. The dry decontamination technologies developed are the carbon dioxide pellet spray method and the PFC spray method. As a part of the project, PFC ultrasonic decontamination technology was developed in 2004. The PFC spray decontamination method which is based on the test results of the PFC ultrasonic method has been under development since 2005. The developed PFC spray decontamination equipment consists of four modules (spray, collection, filtration and distillation). Vacuum cup of the collection module gathers the contaminated PFC solution, then the solution is moved to the filtration module and it is recycled. After a multiple recycling of the spent PFC solution, it is purified in the distillation module. A performance test on each module was executed and the results have been reported. A combined test of the four modules, however, has not been performed as yet. The main objective of the present study is to demonstrate the feasibility of the full PFC spray decontamination process. Decontamination of the inside of the IMEF hot cell by the PFC spray method was also performed. PFC spray decontamination process was demonstrated by using a surrogate wall contaminated with Eu{sub 2}O{sub 3} powder. The spray pressure was 41 kgf/cm{sup 2}, the orifice diameter was 0.2 mm and the spray velocity was 0.2 L/min. And, the decontaminated area was 100 cm{sup 2}. From previous test results, we found that the decontamination factor of the PFC spray method was in the range from 9.6 to 62.4. When the decontamination efficiency of Co-60 was high, then the decontamination efficiency of Cs-137 was also high. As the surface roughness of the specimen increased, the PFC spray decontamination efficiency decreased. Inferring from the previous results, the surface of the surrogate wall was cleaned by the PFC spray method. The vacuum cup of the collection module operated well and gathered more than 99 % of the PFC solution. Also, filtration and distillation modules operated well. All the filtered PFC solution flowed to the storage chamber where some of the PFC solution was distilled. The coolant of the distillation module was a dry ice. And, the recycled solution was transferred to the spray module by a high pressure pump. To evaluate the PFC spray decontamination efficiency, a smear device was fabricated and operated by a manipulator. Before and after decontamination, a smear test was performed. The tested area was 100 cm{sup 2} and the radioactivity was estimated indirectly by measuring the radioactivity of the filter paper. The average decontamination factor was in the range between 10 and 15. One application time was 2 minutes. The sprayed PFC solution was collected by the vacuum cup and it was stored in the collection equipment. After the termination of the decontamination test, the flexible hose was cut near a toboggan. The collection equipment that contained the spent PFC solution, vacuum cup, spray nozzle and the flexible hose was stored in a radioactive waste storage tank. A feasibility study for the PFC spray decontamination method for an application to a hot cell surface was performed. The decontamination equipment that consisted of four modules operated well in the hot cell. The collection module gathered the sprayed PFC solution. The solution was purified in the filtration or distillation modules. The main characteristic of the distillation module is the use of dry ice as a coolant. The decontamination factor of IMEF hot cell was in the range from 10 to 15. It was difficult to measure the radioactivity accurately at a given time. We, however, concluded that the PFC spray decontamination method is a promising technology. It generated a small amount of secondary waste and used a non-toxic and non-conducting material. Decontamination work was performed with a little loss of the main decontamination agent. Based on the test results, we are developing an improved PFC spray decontamination process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

EVALUATION OF LOW TEMPERATURE ALUMINUM DISSOLUTION IN TANK 51

Liquid Waste Organization (LWO) identified aluminum dissolution as a method to mitigate the effect of having about 50% more solids in High Level Waste (HLW) sludge than previously planned. Previous aluminum dissolution performed in a HLW tank in 1982 was performed at approximately 85 C for 5 days, which became the baseline aluminum dissolution process. LWO initiated a project to modify a waste tank to meet these requirements. Subsequent to an alternative evaluation, LWO management identified an opportunity to perform aluminum dissolution on sludge destined for Sludge Batch 5, but within a limited window that would not allow time for any modifications for tank heating. A variation of the baseline process, dubbed Low Temperature Aluminum Dissolution (LTAD), was developed based on the constraint of available energy input in Tank 51 and the window of opportunity, but was not constrained to a minimum extent of dissolution, i.e. dissolve as much aluminum as possible within the time available. This process was intended to operate between 55 and 70 C, but for a significantly longer time than the baseline process. LTAD proceeded in parallel with the baseline project. The preliminary evaluation at the completion of LTAD focused on the material balance and extent of the aluminum dissolved. The range of values of extent of dissolution, 56% to 64%, resulted from the variation in liquid phase sample data available at the time. Additional solid phase data is available from a sample taken after LTAD to refine this range. This report provides additional detailed evaluation of the LTAD process based on analytical and field data and includes: a summary of the process chronology; a determination of an acceptable blending strategy for the aluminum-laden supernate stored in Tank 11; an update to the determination of aluminum dissolved using more complete sample results; a determination of the effect of LTAD on uranium, plutonium, and other metals; a determination of the rate of heat loss from a quiescent tank; and an evaluation of the aluminum dissolution rate model and actual dissolution rate. LTAD was successfully completed in Tank 51 with minimal waste tank changes. The following general conclusions may be drawn about the LTAD process: (1) Dissolution at about 60 C for 46 days dissolved 64% of the aluminum from the sludge slurry. (2) The aluminum-laden leach solution decanted to Tank 11 can be blended with a wide variety of supernates without risk of precipitating the dissolved aluminum based on thermodynamic chemical equilibrium models. (3) Uranium and plutonium leached into solution without corresponding leaching of iron or metal other than aluminum, but the total mass leached was a small fraction of the total uranium and plutonium in the sludge. (4) The concentration of uranium and plutonium in the leach solution was indistinguishable from other tank farm supernates, thus, the leach solutions can be managed relative to the risk of criticality like any other supernate. (5) A small amount of mercury leached into solution from the sludge causing the liquid phase concentration to increase 6 to 10 fold, which is consistent with the 4 to 14 fold increase observed during the 1982 aluminum dissolution demonstration. (6) Chromium did not dissolve during LTAD. (7) Chloride concentration increased in the liquid phase during LTAD due to chloride contamination in the 50% sodium hydroxide solution. (8) The rate of heat loss from Tank 51 at temperatures above 45 C appeared linear and predictable at 8E+7 cal/hr. (9) The rate of heat transfer from Tank 51 did not follow a simplified bulk heat transfer model. (10) Prediction of the aluminum dissolution rate was prone to error due to a lack of active specific surface area data of sludge particles. (11) The higher than expected dissolution rate during LTAD was likely due to smaller than expected particle sizes of most of the sludge particles. While evaluating the LTAD process, the dissolved salt solution from Tank 41 that was stored and sampled in Tank 49 was determined to be supersaturated relative to aluminum. Supersaturation in Tank 49 is not a risk to LTAD. However, storing and processing of this supernate carries a risk of solids precipitation, primarily in the form of gibbsite or boehmite. Blending with the supernate in Tank 11 neither increases nor decreases this risk. LTAD was initiated as an opportunity to substantially mitigate the planned increase in canister production and DWPF lifecycle after the realization of more sludge solids stored in the HLW tanks. As determined from the preliminary evaluation of LTAD, the direct benefit of the decanted liquid stored in Tank 11 represents 45 canisters at 34% waste loading with potential indirect benefits for much larger reductions. Application of an aluminum dissolution process to the remaining high aluminum content sludge will potentially reduce the planned canister production by several hundred canisters at 34%-38% waste loading.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Effectiveness, Compact, High Pressure and Low Cost Recuperator for Super-Critical CO2 Power Cycles, Paper Presented at The Fifth International Symposium – Super-Critical CO2 Power Cycles, San Antonio, Texas, March 28-31, 2016, by Dr. John Kelly, President, Altex Technologies Corporation

Closed Brayton super-critical CO2 power cycles are well suited to waste heat bottoming cycles, due to their increased efficiency and compactness, relative to Rankine steam bottoming cycles. Since waste heat applications would be retrofits, the power system compactness is important. To achieve high efficiency, these power cycles require high pressure recuperative type heat exchangers, of substantial heat duty. Current Printed Circuit Heat Exchangers (PCHE), originally developed for high pressure gas and oil applications, can be used as recuperators, but costs are higher than desired. Altex is developing a purpose-built high pressure and effectiveness recuperator to provide the reliability, compactness, performance and pressure capability of current recuperators, but at a reduced cost. The High Effectiveness Low Cost (HELC) recuperative heat exchanger design yields volume and weight metrics of .0024 m3/UA and 10.2 kg/UA, which are 4% and 77.3% below recuperator target metrics, respectively. A 50 kW test article was designed and fabricated. Performance tests on water and oil showed that the HELC design model could predict heat transfer, to within 10% of the measured value. This model was then used to project HELC performance, when operating on supercritical CO2. Besides performance tests, the test article was hydrostatically tested, for integrity at up to 4,000 psi pressure. At these conditions, some distortion of channels was encountered. To mitigate distortion, the inserts were redesigned and these results were used to project the cost of 500 kW and 5,083 kW HELC units. The cost metric for the 5,083 kW unit was determined to be $1,349/UA, which is 10% lower than the recuperator desired cost metric desired target of $1,500/UA. In addition, the 5,083 kW unit HELC cost of $61.09/kW is 33.6% lower than the $92/kW estimated cost for a PCHE. Hydrostatic pressure tests, at up to 4,000psi, showed that the unit did not leak. However, channels were distorted at this pressure differential. Design updates to minimize stress concentrations and distortion were prepared and analyzed, to show that distortion could be controlled, but to date tests have not been run to prove the design. Project results show the potential of the HELC approach, but more work is required to confirm this potential, at the larger scales of interest.

14 SOLAR ENERGY↗

Efficiency analysis of semi-open sorption heat pump systems

Sorption systems traditionally fall into two categories: closed (heat pumps and chillers) and open (dehumidification). Recent work has explored the possibility of semi-open systems, which can perform heat pumping or chilling while utilizing ambient humidity as the working fluid of the cycle, and are still capable of being driven by solar, waste, or combustion heat sources. The efficiencies of closed and open systems are well characterized, and can typically be determined from four temperature s. In this work, the performance potential of semi-open systems is explored by adapting expressions for the efficiency of closed and open systems to the novel semi-open systems. A key new parameter is introduced, which involves five temperatures, since both the ambient dry bulb and ambient dew point are used. Furthermore, this additional temperature is necessary to capture the open absorber performance in terms of both the absorption of humidity and sensible heat transfer with surrounding air.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗