Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VOLTAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Origin of transverse voltages generated by thermal gradients and electric fields in ferrimagnetic-insulator/heavy-metal bilayers

We compare thermal-gradient-driven transverse voltages in ferrimagnetic-insulator/heavy-metal bilayers (Tm 3 Fe 5 O 12 /W and Tm 3 Fe 5 O 12 /Pt) to corresponding electrically driven transverse resistances at and above room temperature. We find for Tm 3 Fe 5 O 12 /W that the thermal and electrical effects can be explained by a common spin-current detection mechanism, the physics underlying spin Hall magnetoresistance (SMR). However, for Tm 3 Fe 5 O 12 /Pt the ratio of the electrically driven transverse voltages (planar Hall signal/anomalous Hall signal) is much larger than the ratio of corresponding thermal-gradient signals, a result which is very different from expectations for a SMR-based mechanism alone. Here, we ascribe this difference to a proximity-induced magnetic layer at the Tm 3 Fe 5 O 12 /Pt interface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Voltage-controlled magnetic anisotropy enabled by resistive switching

The discovery of new mechanisms of controlling magnetic properties by electric fields or currents furthers the fundamental understanding of magnetism and has important implications for practical use. Here, we present an approach of utilizing resistive switching to control magnetic anisotropy. We study a ferromagnetic oxide that exhibits an electrically triggered metal-to-insulator phase transition producing a volatile resistive switching. The switching occurs in a characteristic spatial pattern, the formation of an insulating barrier perpendicular to the current flow, which results in an unusual ferromagnetic/paramagnetic/ferromagnetic configuration. Further, the formation of this voltage-driven paramagnetic insulating barrier is accompanied by the emergence of a strong uniaxial magnetic anisotropy that overpowers the intrinsic material anisotropy. Our results demonstrate that resistive switching is an effective tool for manipulating magnetic properties. Because resistive switching can be induced in a broad range of materials, our findings could enable a new class of voltage-controlled magnetism systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Local twin domains and tip-voltage-induced domain switching of monoclinic M C phase in Pb ( M g 1 / 3 N b 2 / 3 ) O 3 - 0.34 PbTi O 3 single crystal revealed by piezoresponse force microscopy

Here, the monoclinic (M) phases in high-performance relaxor-based ferroelectric single crystals have been recognized to be a vital structural factor for the outstanding piezoelectric property. However, due to the complexity of the structure in M phases, the understanding about it is still limited. In this paper, the local twin domains and tip-voltage-induced domain switching of the M C phase in Pb(Mg 1/3 Nb 2/3 )O 3 - 0.34PbTiO 3 (PMN-0.34PT) single crystal have been intensively investigated by piezoresponse force microscopy (PFM). By theoretically analyzing the experimental patterns of domain walls on the (001) C face, the specific M C twin domains in the initial annealed state of a selected area have been clarified, and the polarization orientation of the M C phase in this sample is determined to be at an angle of 29 degrees to the < 001 > C directions. In addition, based on the evolution of domains and the motion of domain walls under the step-increased PFM tip dc voltage (V dc ), the switching process and features of different types of M C domain variants are visually revealed

74 ATOMIC AND MOLECULAR PHYSICS↗

Decentralized Voltage and Power Control of Multi-Machine Power Systems With Global Asymptotic Stability

Maintaining power system stability is becoming urgent due to the large-scale interconnection of power grids and the high penetration of uncertain renewable energy sources. The excitation control and governor control of synchronous generators have been considered as two crucial measures for enhancing the power system stability. However, a major challenge is to simultaneously achieve global asymptotic stability (GAS), voltage regulation (VR), and power regulation (PR) in the excitation and governor control. In this paper, a Lyapunov-based decentralized control (LBC) is proposed to address this challenge. The time-derivative of the Lyapunov function is designed by the feedback control of synchronous generators in order to guarantee GAS. VR and PR are ensured by considering voltage and power deviations as the feedback variables. The simulation results on the New-England ten-machine power system validate the effectiveness of the proposed LBC in improving power system transient stability and simultaneously achieving VR and PR. Although the proportional-integral- and power system stabilizer-based control can also perform VR and PR, the proposed control has much better dynamic performance and can more significantly improve the system transient stability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Circulating Current Reduction of Back-to-Back MMC with Advanced Grid-Support Functionalities for Medium-Voltage Applications

A Lyapunov energy function based circulating current reduction scheme for a back to back modular multilevel converter based system for a microgrid application has been proposed in this digest. In order to ensure no circulating or zero sequence currents within the modules, the dynamics from one leg of the converter to the other are evaluated. A Lyapunov energy function is then developed and utilizing the circulating current dynamics of the converter the overall control law is implemented. In this digest a decentralized hierarchical control architecture has been implemented for the main current control; where the outer loop or the central controller implements the higher level grid interconnection functions as per IEEE 1547-2018 standards and the inner loop based on synchronous reference frame implements the current control architecture. The inner loops' outputs are the commanded converter voltages either on either side which are augmented by the Lyapunov energy function based circulating current suppression architecture. To evaluate the efficacy of the overall system, the overall system is modeled around a 300kVA back to back SiC multilevel modular converter used as a direct-connected medium voltage (MV) grid intertie based on MATLAB/Simulink domain. Several important case studies are presented in this paper to prove the effectiveness of the proposed architecture. case study results are presented.

circulating current↗

A Machine Learning based Approach of Estimating Equivalent Circuit Model Parameters at Different SoCs of Li-ion Batteries from Voltage Relaxation

Abstract: In this study, an approach of estimating the equivalent circuit model (ECM) parameters for Li-ion batteries (LIBs) is proposed based on the voltage value at different intervals while relaxing the LIB after discharge. The typical approach for estimating ECM parameters of a LIB is to conduct electrochemical impedance spectroscopy (EIS) measurements at different frequencies and fit them to a predefined circuit model, which requires additional measuring arrangements and specialized devices. The proposed methodology utilizes four different voltages at 0s, 60s, 360s, and 1800s alongside the specific state of charge (SoC) value for a specific constant discharge current value of ~1C until the relaxation stage to train and evaluate three regression-based machine learning models— Support Vector Regression (SVR), Extreme Gradient Boosting (XGBoost), and Gaussian Process Regression (GPR)—for estimating the ECM parameters of the selected model. Bayesian optimization is employed for hyperparameter tuning to achieve optimal performance for all the regressor models, among which, the GPR provided the best performance with the root-mean-squared error (RMSE) of less than 4x10-4 on average for the resistive components and less than 0.27 for capacitive components with excellent R2 scores. The simplicity of the approach enables it to eliminate the need for sophisticated measuring equipment and computation power.

Sagar, Md. Samiul [The University of Alabama (UA)]↗

Temperature Dependence of FDR Response for Thermally Aged Low-Voltage Cables

Frequency Domain Reflectometry (FDR) has attracted significant attention for use in nuclear power plants (NPPs) for non-destructive cable health monitoring. However, cable aging detection using FDR faces challenges due to its high sensitivity to environmental factors such as temperature, vibrations, proximity to other cables, and so on. This work aims to evaluate the influence of measurement temperature on the FDR reflected signal in a low voltage cable undergoing accelerated thermal aging. A 100 ft long multi-core low-voltage unshielded power cable insulated with flame retardant ethylene propylene rubber (FR-EPR) and covered by a chloro-polyethylene (CPE) jacket was selected for this study. The cable was energized during aging by a 480 VAC 3-phase motor, and a 30 ft mid-section of this cable was routed through an air circulating oven held at 140 °C for up to an effective aging time of 62 days. FDR measurements were taken periodically with the oven on (at 140 °C) and with the oven off (at 22 °C). A comparative analysis of data collected at both temperatures showed that the FDR response was strongly dependent on measurement temperature. FDR measurements at ambient temperature showed large peaks corresponding to impedance changes in the aged section of the cable after 3 days of aging. These peaks continued to rise steadily with increasing aging time. However, for measurements taken at 140 °C, slowly rising peaks in the oven region (aged section) were observed only after a lead time of 23 days of aging. This work highlights the importance of measurement temperature on the performance of FDR as a condition monitoring tool for aging cables.

Sriraman, Aishwarya↗

Electrical design analysis and breakdown voltage test aspects of indigenously developed electrical breaks at Cryo temperatures

Electrical insulation breaks are very critical component of large-scale fusion devices employing superconducting magnets and are used to insulate electrically the coil and the cryogenic supply line (kept at ground potential). The electrical insulation of breaks consists of the composites insulations, G-10 GFRP (Glass fiber reinforced plastic), cryogenic compatible epoxy and S-glass boron free fiber in air and helium environment under vacuum. To optimize the design parameters, the detailed electrical analysis have been carried out using the electrostatic solid axi-symmetric model by COMSOL 4.1 multiphysics software for electrodes separation, electrical field strength as well as flashover phenomenon between two electrodes with composite insulator material have been analyzed at different surfaces and contours along with by varying gaps between SS electrodes. We have carried out the high voltage breakdown test (0-35) kV, insulation resistance measurement at 0-5 kV test voltage in Paschen condition of (10{sup 3} -10{sup -5}) mbar in helium gas and air environment at 300 K and 77 K experimentally on in-house developed insulation breaks. (author)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Variable Duty Control of Three-Phase Voltage Source Inverter for Wireless Power Transfer Systems

This paper presents duty control and analysis of the three-phase voltage source inverter (VSI) to adjust the output power for three-phase wireless power transfer (WPT) applications. Analytical results show significant reductions in the inverter dc link ripple current with the three-phase system over single-phase WPT counterparts. Simulation and experimental results for an 18 kW three-phase series-series WPT system are included to validate the duty control and analysis. Experimental results also demonstrated the output voltage can be controlled over a wide range by adjusting the inverter duty.

Su, Gui-Jia↗

Levelized-Cost-of-Electricity-Driven Design Optimization for Medium-Voltage Transformerless Photovoltaic Converters

Design approaches for power electronics are typically focused on efficiency and power density; however, these strategies do not guarantee cost optimality in any well-defined sense. To overcome this shortcoming, we propose a design framework that yields circuit parameters that minimize the levelized cost of electricity (LCOE) of a generation system. LCOE serves as a meaningful metric since it captures total lifetime costs - including hardware, balance of system, and maintenance costs - and includes the impacts of power conversion efficiency and revenue from harvested energy. To obtain a tractable design problem, we formulate an approximate LCOE improvement model that quantifies the changes in LCOE resulting from a candidate converter design. We apply this framework to a multilevel cascaded topology for low-voltage dc to medium-voltage ac conversion without line-frequency transformers. An example 200 kW commercial-scale system is studied and the solution yields a design with 15 cascaded stages, 98.01% efficiency, and an LCOE reduction of 2.0%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Suppression of Parasitic Voltage Oscillation in Power Modules by Turn-Off Current Zero Placement

This paper presents a frequency-domain analysis of the turn-off equivalent switching network of a hard-switched semiconductor switching cell. This paper also proposes a novel method to suppress parasitic voltage ringing by placing the turn-off current zero at the parasitic resonant frequency. The turn-off current was decomposed into ramp functions and a constant-valued function to facilitate obtaining the frequency components of the turn-off current using the Laplace transform of standard signals. The proposed frequency-domain modeling of the parasitic voltage ringing and the suppression were validated by detailed circuit simulation using parameters corresponding to prior literature with experimental validation.

Galigekere, Veda Prakash↗

Quantifying Transmission Fault Voltage Influence and its Potential Impact on Distributed Energy Resources

With increasing shares of distributed energy resources (DERs) on the electric grid, the power system is transitioning from having fewer large generators with relatively simple dynamics to many small generators with aggregate responses to system disturbances that are difficult to predict. In particular, voltage fluctuations might cause large losses of generation via DER operation/interconnection compliance. To understand orchestral DER dynamics, a first step is to determine the influence of a disturbance on the overall bulk power system. This work introduces metrics that allow for the classification and comparison of a variety of system faults with respect to their influences on voltage profiles. These metrics are applied to standardized fault simulations on the Western Interconnection Paths with a full-scale Positive Sequence Load Flow model. The results are presented with a highlight on Path 61, which has the potential for DER generation reduction exceeding the current credible contingency of a double Palo Verde loss.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Fairness-based Distributed Energy Coordination for Voltage Regulation in Distribution Systems

The rapid adoption of photovoltaic (PV) systems combined with falling prices of energy storage is paving the way for a future in which customers could locally supply their energy needs and export surplus power to the grid. However, reverse power flow from multiple sites in a network can cause overvoltage that decreases system reliability and the utilization level of PV system. In this paper, we present a two-stage approach to solve the energy coordination problem in distribution networks. In the first stage, a household with PV and energy storage is optimized to allow customers to adopt different control strategies such as load following and tariff arbitrage. We show that such customer-led control strategies can cause reverse power flows during peak PV generation periods, thus resulting in overvoltage. In such cases, the second stage of the proposed approach is called upon to solve a fairness-based energy coordination problem that can maintain voltages within limits while maximizing the PV generation while fairly distributing the actions among all the PV systems. As a result, each of the resources in the network has equal opportunity to export power and shares the responsibility of voltage regulation. Simulation studies have been carried out on the IEEE 13-bus test feeder to verify the effectiveness of the proposed approach.

Distributed energy resources, fairness, overvoltag↗

Digital Twin-Enabled Adaptive Control for Hydroelectric Systems: Turbine Governor and Voltage Regulation

This paper presents a comprehensive digital twin (DT) framework for hydroelectric systems that enables adaptive control of turbine governors and excitation systems without requiring detailed manufacturer specifications. The proposed framework integrates neural network-based system identification with stabilizing adaptive control laws for the installed turbine controller and middle-branch adaptive tuning for the installed voltage regulator. Using real operational data from Unit C-8 at Rocky Reach Dam (1,349 MW capacity), highfidelity neural network models are developed to capture turbine and generator dynamics without requiring detailed manufacturer specifications. The DT enables safe controller synthesis and validation in simulation before deployment. For turbine control, the proposed method achieves a 79.9% mean square error (MSE) reduction compared with that of an optimal controller. For voltage regulation, the adaptive excitation controller achieves approximately 42.6% MSE reduction while preserving installed protection logic. The results demonstrate that DT technology provides a practical pathway for modernizing hydropower control systems with minimal operational disruption.

Gui, Yonghao [ORNL] (ORCID:0000000250435534)↗

Study on Conversion from an Existing Alternating Current Medium-Voltage Line to a Direct Current Line: A Case of Load or Source Expansion

Simultaneous increase of power generation through renewable systems and load due owing to the rapid growth in electrified road transportation systems, leads to new challenges in the design, operation, and protection of distribution-level electrical power systems. This paper addresses challenges related to the integration of new sources or loads to a distribution grid through long alternating current lines. The International Council on Large Electric Systems medium-voltage benchmark model developed for North America was used for simulation studies. Use cases were developed to illuminate the issues related to long alternating current lines and the usefulness of medium-voltage direct current lines in a distribution network.

Jaldanki, Sreenivasa↗

Voltage and Current Response Characteristics of PMU Device by PCI Simulation

Phasor Measurement Units (PMUs) are critical for the Wide Area Measurement System (WAMS), especially for real-time grid monitoring, disturbance location, and situation awareness. Once they are damaged, the stable operation of power system will be affected directly and greatly. As new electronic devices in power system, their immunity to electromagnetic pulse (EMP) events needs to be studied. In this paper, an effective impedance measurement scheme is proposed for port impedance measurement of PMU. A non-uniform transmission line model is established to eliminate the impact of fixture in the de-embedding process. Then circuit of pulse current generator is established to generate damping sinusoid and double exponential wave applied to the port. Finally, by using measured impedance as load of the generator, the voltage and current responses of different ports are calculated in the pulsed current injection (PCI) simulation. Results shows the characteristics of port impedance, voltage and current waveforms. The relation between port impedance and the waveforms is discussed.

Zhang, Liang↗

Operation and Control of Electric Vehicle Charger with Enhanced Dynamic Performance Under Non-Ideal Grid Voltage Condition

This paper presents a three-phase electric vehicle charger connected to the grid, featuring multiple boost converters on the DC side, specifically designed to ensure smooth, oscillation-free power transfer during unsymmetrical voltage sags. Precise control mechanisms are implemented on the boost converter side to regulate both voltage and current on the electric vehicle side, thereby maintaining optimal charging conditions. The control architecture for both the grid-connected and boost converter components is based on the Lyapunov energy function, which is employed to achieve superior dynamic performance and stability. The system's robustness and reliability are demonstrated through its ability to maintain stable operation and efficient power transfer despite fluctuations in grid conditions. Furthermore, the implementation of Lyapunov-based control ensures rapid response and minimal energy loss, enhancing the overall efficiency of the system. To validate the effectiveness of this approach, a comprehensive model of the system was developed and tested using MATLAB/Simulink, with detailed computer simulations conducted across various significant case studies.

DC-DC boost converter↗

DERMS Online: A New Voltage Sensitivity-Enabled Feedback Optimization Framework

This paper proposes a distributed energy resource management system (DERMS) solution by developing a new voltage sensitivity-enabled feedback optimization framework. The key idea is to adopt a measurement feedback scheme to reformulate the original nonlinear optimization into a linear programming (LP) problem via perturb-and-observe-based voltage sensitivity analysis. The proposed solution eliminates the dependence on load knowledge and can be implemented online thanks to an efficient open-source solver for LP problems. Comparison results with other control methods on a real distribution feeder in Southern California highlight the feasibility as well as benefits for the proposed framework.

distributed energy resource management↗