Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMAL SIMULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Simulation of the synergistic low Earth orbit effects of vacuum thermal cycling, vacuum UV radiation, and atomic oxygen

In order to assess the low Earth orbit (LEO) durability of candidate space materials, it is necessary to use ground laboratory facilities which provide LEO environmental effects. A facility combining vacuum thermal cycling and vacuum ultraviolet (VUV) radiation has been designed and constructed at NASA Lewis Research Center for this purpose. This facility can also be operated without the VUV lamps. An additional facility can be used to provide VUV exposure only. By utilizing these facilities, followed by atomic oxygen exposure in an RF plasma asher, the effects of the individual vacuum thermal cycling and VUV environments can be compared to the effect of the combined vacuum thermal cycling/VUV environment on the atomic oxygen durability of materials. The synergistic effects of simulated LEO environmental conditions on materials were evaluated by first exposing materials to vacuum thermal cycling, VUV, and vacuum thermal cycling/VUV environments followed by exposure to atomic oxygen in an RP plasma asher. Candidate space power materials such as atomic oxygen protected polyimides and solar concentrator mirrors were evaluated using these facilities. Characteristics of the Vacuum Thermal Cycling/VUV Exposure Facility which simulates the temperature sequences and solar ultraviolet radiation exposure that would be experienced by a spacecraft surface in LEO are discussed. Results of durability evaluations of some candidate space power materials to the simulated LEO environmental conditions will also be discussed. Such results have indicated that for some materials, atomic oxygen durability is affected by previous exposure to thermal cycling and/or VUV exposure.

Dever, Joyce A.↗

Benchmark of Neutron Thermalization in Graphite Using a Pulsed Slowing-Down-Time Experiment

A benchmark has been developed using a pulsed slowing-down-time experiment to isolate the thermalization process in graphite. The experiment was conducted at the Oak Ridge Electron Linear Accelerator facility at Oak Ridge National Laboratory, and it measured the time spectrum of neutrons leaking from a graphite pile during slowing down and thermalization within graphite. Simulations of the benchmark experiment were performed using the MCNP6.1 Monte Carlo code and the ENDF/B-VII.1 and ENDF/B-VIII.0 cross-section databases. The benchmark provides a time spectrum (i.e., time-dependent counts in a detector) that allows for validation of the graphite thermal scattering libraries (TSLs). The impact on the simulations using a suite of graphite TSLs was compared with the experimental results. Given the density of nuclear graphite, the TSL corresponding to graphite with 30% porosity, as implemented in ENDF/B-VIII.0, was found to most accurately represent the measured time spectrum corresponding to the thermal energy range with an average deviation of ±1.7%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ocean cavity regime shift reversed West Antarctic grounding line retreat in the late Holocene

Recent geologic and modeled evidence suggests that the grounding line of the Siple Coast of the West Antarctic Ice Sheet (WAIS) retreated hundreds of kilometers beyond its present position in the middle to late Holocene and readvanced within the past 1.7 ka. This grounding line reversal has been attributed to both changing rates of isostatic rebound and regional climate change. Here, we test these two hypotheses using a proxy-informed ensemble of ice sheet model simulations with varying ocean thermal forcing, global glacioisostatic adjustment (GIA) model simulations, and coupled ice sheet-GIA simulations that consider the interactions between these processes. Our results indicate that a warm to cold ocean cavity regime shift is the most likely cause of this grounding line reversal, but that GIA influences the rate of ice sheet response to oceanic changes. This implies that the grounding line here is sensitive to future changes in sub-ice shelf ocean circulation.

58 GEOSCIENCES↗

The Dependence of the Change in the Coefficient of Thermal Expansion of Graphite Fiber Reinforced Polyimide IM7-K3B on Microcracking due to Thermal Cycling

Composite IM7-K3B was subjected to a simulated high speed aircraft thermal environment to determine the effects of microcracking on the change in CTE. IM7-K3B is a graphite fiber reinforced polyimide laminate, manufactured by Dupont. The lay-up for the material was (0.90((Sub 3)(Sub s))). The specimens were placed in a laser-interferometric dilatometer to obtain thermal expansion measurements and were then repeatedly cycled between -65 F and 350 F up to 1000 cycles. After cycling they were scanned for microcracks at a magnification of 400x. The material was expected not to crack and to have a near zero CTE. Some microcracking did occur in all specimens and extensive microcracking occurred in one specimen. Further testing is required to determine how closely the CTE and microcracking are related.

Stewart, Melissa C.↗

Enhanced Thermal Conductivity UO{sub 2}-BeO and UO{sub 2}-SiC Fuels Behavior

Commercial light-water reactors currently use UO{sub 2} as a nuclear fuel, which has demonstrated several desirable characteristics. However, UO{sub 2} has a low thermal conductivity that leads to the development of a large temperature gradient across the fuel pellet. This temperature gradient contributes to limits in the operational performance of the reactor due to effects that include thermal stresses causing pellet cladding interaction and the release of fission product gases as demonstrated. These high fuel temperatures can be decreased and reactor performance improved by developing an enhanced thermal conductivity nuclear fuel. A high thermal conductivity nuclear fuel would decrease fuel temperatures and facilitate a reduction in pellet cladding interaction through lessening thermal stresses that result in fuel cracking, relocation, and swelling as described. Additionally, fission gas release would be decreased allowing for higher fuel burn-up, and the safety of the reactor would be improved with a faster thermal response and less stored energy in the fuel pins. A ceramic-ceramic composite nuclear fuel has an increased effective thermal conductivity due to adding a second compatible and high thermal conductivity ceramic to UO{sub 2}. SiC and BeO are two materials that demonstrate compatibility with UO{sub 2} and have a high thermal conductivity. In summary, the enhanced thermal conductivity UO{sub 2}-BeO and UO{sub 2}-SiC fuel performance has been modelled in a light water reactor, and a more complete and detailed understanding was achieved for enhanced thermal conductivity UO{sub 2}-BeO and UO{sub 2}-SiC fuels. BeO and SiC have high melting point, low neutron absorption, low thermal expansion coefficient and chemical compatibility with current UO{sub 2} fuels which makes them a suitable material for thermal conductivity enhancement. In our modeling and simulation work, the enhanced thermal conductivity nuclear fuel showed the capability of decreasing the fuel temperatures, increasing the gap total conductance, reducing the fission gas release, decreasing the gap/plenum pressure, lessening oxygen redistribution, and facilitating a reduction in pellet cladding interaction through lessening thermal stresses that result in fuel cracking, relocation, and swelling. The safety of the reactor operation would be then improved. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Strain-controlled thermal conductivity in ferroic twinned films

Large reversible changes of thermal conductivity are induced by mechanical stress, and the corresponding device is a key element for phononics applications. We show that the thermal conductivity k of ferroic twinned thin films can be reversibly controlled by strain. Nonequilibrium molecular dynamics simulations reveal that thermal conductivity decreases linearly with the number of twin boundaries perpendicular to the direction of heat flow. Our demonstration of large and reversible changes in thermal conductivity driven by strain may inspire the design of controllable thermal switches for thermal logic gates and all-solid-state cooling devices.

SURFACES, INTERFACES AND THIN FILMS↗

Engineering Thermal Transport across Layered Graphene–MoS 2 Superlattices

Layering two-dimensional van der Waals materials provides a high degree of control over atomic placement, which could enable tailoring of vibrational spectra and heat flow at the sub-nanometer scale. In this work, using spatially resolved ultrafast thermoreflectance and spectroscopy, we uncover the design rules governing cross-plane heat transport in superlattices assembled from monolayers of graphene (G) and MoS 2 (M). Using a combinatorial experimental approach, we probe nine different stacking sequences, G, GG, MG, GGG, GMG, GGMG, GMGG, GMMG, and GMGMG, and identify the effects of vibrational mismatch, interlayer adhesion, and junction asymmetry on thermal transport. Pure G sequences display evidence of quasi-ballistic transport, whereas adding even a single M layer strongly disrupts heat conduction. The experimental data are described well by molecular dynamics simulations, which include thermal expansion, accounting for the effect of finite temperature on the interlayer spacing. The simulations show that an increase of ~2.4% in the layer separation of GMGMG, relative to its value at 300 K, can lead to a doubling of the thermal resistance. Using these design rules, we experimentally demonstrate a five-layer GMGMG superlattice “thermal metamaterial” with an ultralow effective cross-plane thermal conductivity comparable to that of air.

2D materials↗

The Evaporation and Survival of Cluster Galaxy Coronae. I. The Effectiveness of Isotropic Thermal Conduction Including Saturation

We simulate the evolution of cluster galaxy hot interstellar medium (ISM) gas that is a result of the effects of ram pressure and thermal conduction in the intracluster medium (ICM). At the density and temperature of the ICM, the mean free paths of ICM electrons are comparable to the sizes of galaxies, therefore electrons can efficiently transport heat that is due to thermal conduction from the hot ICM to the cooler ISM. Galaxies consisting of dark matter halos and hot gas coronae are embedded in an ICM-like “wind tunnel” in our simulations. In this paper, we assume that thermal conduction is isotropic and include the effects of saturation. We find that as heat is transferred from the ICM to the ISM, the cooler denser ISM expands and evaporates. This process is significantly faster than gas loss due to ram pressure stripping; for our standard model galaxy, the evaporation time is 160 Myr, while the ram pressure stripping timescale is 2.5 Gyr. Thermal conduction also suppresses the formation of shear instabilities, and there are no stripped ISM tails since the ISM evaporates before tails can form. Observations of long-lived X-ray emitting coronae and ram pressure stripped X-ray tails in galaxies in group and cluster environments therefore require that thermal conduction is suppressed or offset by some additional physical process. The most likely process is anisotropic thermal conduction that is due to magnetic fields in the ISM and ICM, which we simulate and study in the next paper in this series.

79 ASTRONOMY AND ASTROPHYSICS↗

Integrated Cryogenic Propulsion Test Article Thermal Vacuum Hotfire Testing

In support of a facility characterization test, the Integrated Cryogenic Propulsion Test Article (ICPTA) was hotfire tested at a variety of simulated altitude and thermal conditions in the NASA Glenn Research Center Plum Brook Station In-Space Propulsion Thermal Vacuum Chamber (formerly B2). The ICPTA utilizes liquid oxygen and liquid methane propellants for its main engine and four reaction control engines, and uses a cold helium system for tank pressurization. The hotfire test series included high altitude, high vacuum, ambient temperature, and deep cryogenic environments, and several hundred sensors on the vehicle collected a range of system level data useful to characterize the operation of an integrated LOX/Methane spacecraft in the space environment - a unique data set for this propellant combination.

Morehead, Robert L.↗

Simulation of Conduction Cooled SRF Cavity

SRF cavities are used heavily in high energy physics research, and simplifying operation of SRF cavities could enable their use in many fields of industry. Liquid helium coolant systems are a notable complexity of operating SRF cavities, and replacing liquid helium with cryocooler conduction cooling is an important research and development interest. As part of this effort, a system consisting of a 650 MHz single cell cavity, a commercial grade pulse tube refrigerator, and an aluminum thermal link was simulated through finite element analysis. The electromagnetic fields inside the cavity, heat flow through the system, and temperature distribution of the thermal link and cavity were calculated. Based on the simulations, the pulse tube refrigerator is capable of supplying adequate cooling power to a cavity with \ce{Nb3Sn} coating operating with an accelerating gradient between 6 and 12 MV/m. The maximum simulated temperature of the cavity was below 7 K, and the oscilla tions in temperature introduced by the pulse tube refrigerator were shown to dampen in amplitude before reaching the cavity surface.

43 PARTICLE ACCELERATORS↗

Thermal Modelling of Advanced Test Reactor Fuel in a Generalized Dry Storage System

Star-CCM+, a computational fluid dynamics (CFD) software was used to conduct modeling and simulation of the thermal performance of a dry storage configuration consisting of Department of Energy Standardized Canisters (DOESCs) loaded with aluminum-clad spent nuclear fuel (ASNF.) The configuration includes nine DOESCs loaded with Advanced Test Reactor ASNF contained within a stainless steel overcanister centered in a ventilated, concrete overpack. The simulations were used to estimate the maximum temperatures reached by backfill gases inside the overcanister and DOESCs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Building envelope anomaly characterization and simulation using drone time-lapse thermography

Defects in building envelopes deteriorate over time without being visible to the human eye, while significantly impacting energy performance due to unaccounted heat transfer. Defects can be characterized in the infrared (IR) spectrum. However, IR readings are typically recorded at singular points in time, when in several cases anomalies can only be revealed at specific times of the day, possibly in different seasons of the year. This paper presents a novel workflow for 3D envelope defect characterization and modeling using aerial time-lapse IR data collection using drones. A comprehensive envelope thermal profile is developed for a case study building employing the photogrammetry software Agisoft Photoscan, which generates temporal IR inspections of building skins using multiple thermography orthomosaics. Point-cloud data is then translated into a CAD model and thermal zones for whole Building Energy Modeling (BEM) using Honeybee as a frontend to EnergyPlus to showcase the potential of inclusion of detailed 4D data. Envelope contributions in this case study’s anomalies showed heat losses of 6447.6 kWh, and Energy Use Intensity (EUI) differences of ~2 kWh/m 2 /year from the baseline. Finally, why there is currently little translation of this work in BEM software is discussed, while identifying limitations and future research in the employment of time-lapse thermography using drones for more accurate building envelope inspection and modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal conductivity and spectral phonon properties of freestanding and supported silicene

We conduct molecular dynamics (MD) simulations to study the thermal conductivity of freestanding silicene and silicene supported on an amorphous silicon dioxide (SiO{sub 2}) substrate in the temperature range from 300 to 900 K. The results show that the thermal conductivity decreases with increasing temperature and that the presence of the SiO{sub 2} substrate results in a great reduction, up to 78% at 300 K, to the thermal conductivity of silicene. With atomic trajectories from equilibrium MD simulations, we perform spectral energy density analysis to compute the thermal conductivities, spectral phonon relaxation times, and spectral phonon mean free paths (MFPs) of freestanding and supported silicene at 300 K. When silicene is put on a SiO{sub 2} substrate, the phonon relaxation times are decreased from 1–13 ps to less than 1 ps, and the phonon MFPs are reduced from 10–120 nm to 0–20 nm. We also calculate the thermal conductivity contributions from all phonon branches and find that the thermal conductivities of freestanding and supported silicene are mainly (>85%) contributed by the longitudinal and transverse acoustic phonons, while the out-of-plane acoustic phonons have a contribution less than 3%. Our study predicts the reduction of the thermal conductivity of silicene due to substrate effects and provides a fundamental understanding of the reduction in terms of the spectral phonon relaxation times and MFPs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Computational Fluid Dynamics Modeling of Solar Thermal Dry Reforming of Methane in a Parabolic Trough

Computational fluid dynamics simulations of solar-thermal dry reforming of methane using a parabolic trough configuration were performed. Parametric simulations of different combinations of gas flow rate, receiver tube emissivity, and geometric concentration ratio were conducted to determine configurations that could achieve the required catalyst temperatures of at least 700 °C to achieve high conversion of CH4 and CO2 to H2 and CO. Results showed that the concentration ratio of the parabolic trough collector had to be increased from ~70 to ~120 and the receiver-tube emissivity had to be reduced to ~0.2 to achieve bulk average catalyst temperatures of greater than 700 °C. Lower gas flow rates also reduced enthalpic heat losses and increased catalyst temperatures.

Ho, Clifford↗

NTP system simulation and detailed nuclear engine modeling

The topics are presented in viewgraph form and include the following: nuclear thermal propulsion (NTP) & detailed nuclear engine modeling; modeling and engineering simulation of nuclear thermal rocket systems; nuclear thermal rocket simulation system; INSPI-NTVR core axial flow profiles; INSPI-NTRV core axial flow profiles; specific impulse vs. chamber pressure; turbine pressure ratio vs. chamber pressure; NERVA core axial flow profiles; P&W XNR2000 core axial flow profiles; pump pressure rise vs. chamber pressure; streamline of jet-induced flow in cylindrical chamber; flow pattern of a jet-induced flow in a chamber; and radiative heat transfer models.

Anghaie, Samim↗

Study of thermosiphon cooling scheme for the production solenoid of the Mu2e experiment at Fermilab

A thermosiphon cooling scheme is envisioned for the Production Solenoid of the Mu2e experiment at Fermi National Accelerator Laboratory. The thermosiphon cooling is achieved by indirect cooling with helium at 4.7 K. The siphon tubes are welded to the solenoid outer structure. The anticipated heat loads in the solenoid is presented as well as the cooling scheme design. A thermal model using ANSYS to simulate the temperature gradient is presented. The thermal analysis also makes provisions for including the heat load generated in the coils and structures by the secondary radiation simulated using the MARS 15 code. The impact of the heat loads from supports on the solenoid cooling is studied. The thermosiphon cooling scheme is also validated using pertinent correlations to study flow reversals and the cooling regime.

43 PARTICLE ACCELERATORS↗

Simulations of the fault current limiting operation of a long-length REBCO CORC ® superconducting cable cooled by helium gas

Conductor-on-round-core (CORC®) cables composed of rare-earth-barium-copper-oxide high-temperature superconducting (HTS) tapes are of great interest for power transmission applications due to their many advantages such as high power density, light weight, and low loss. Closed circulation loops of cryogenic helium gas can be used to cool HTS cables down to low temperatures to significantly improve their current-carrying capacity. Coupled circuit-electromagnetic-thermal finite element simulations implemented in the COMSOL Multiphysics package were developed, validated, and then used for simulating the fault current limiting (FCL) performance and the cooling processes of an 8-layer CORC® cable cooled with a flow of cryogenic helium gas. In the simulations, the temperature dependence of the electrical and thermal properties of all component materials is implemented for improved accuracy. To overcome computational challenges caused by the considerable difference in geometrical scales (i.e. few-µm-thick HTS layers versus 10 m-long HTS cable), the model is divided into two separate simulations. The first simulation is performed on the transverse cross-section of the cable to calculate the electric field, heating power and temperature rise in each component of a CORC® cable during FCL operation. The heating power calculated in the first simulation is transferred to the second model to simulate the cooling of a 10 m-long cable after the fault is cleared. The effect of the helium gas flow rate on the cooling process is also investigated to develop strategic approaches for optimizing cooling systems for HTS cables with FCL capability. The simulations indicated that a 40 ms fault with a voltage drop of 20 V m −1 along the cable can result in a temperature increase from 60 K to about 165 K inside the cable, and it takes about 500 s to cool the cable back to nearly 60 K with a flow of cold helium gas at a rate of 5 g s −1 .

24 POWER TRANSMISSION AND DISTRIBUTION↗