The first measurements of soft x-ray flux from ignition scale Hohlraums at the National Ignition Facility using DANTE (invited)

The first 96 and 192 beam vacuum Hohlraum target experiments have been fielded at the National Ignition Facility demonstrating radiation temperatures up to 340 eV and fluxes of 20 TW/sr as viewed by DANTE representing an {approx}20 times flux increase over NOVA/Omega scale Hohlraums. The vacuum Hohlraums were irradiated with 2 ns square laser pulses with energies between 150 and 635 kJ. They produced nearly Planckian spectra with about 30{+-}10% more flux than predicted by the preshot radiation hydrodynamic simulations. To validate these results, careful verification of all component calibrations, cable deconvolution, and software analysis routines has been conducted. In addition, a half Hohlraum experiment was conducted using a single 2 ns long axial quad with an irradiance of {approx}2x10{sup 15} W/cm{sup 2} for comparison with NIF Early Light experiments completed in 2004. We have also completed a conversion efficiency test using a 128-beam nearly uniformly illuminated gold sphere with intensities kept low (at 1x10{sup 14} W/cm{sup 2} over 5 ns) to avoid sensitivity to modeling uncertainties for nonlocal heat conduction and nonlinear absorption mechanisms, to compare with similar intensity, 3 ns OMEGA sphere results. The 2004 and 2009 NIF half-Hohlraums agreed to 10% in flux, but more importantly, the 2006 OMEGA Au Sphere, the 2009 NIF Au sphere, and the calculated Au conversion efficiency agree to {+-}5% in flux, which is estimated to be the absolute calibration accuracy of the DANTEs. Hence we conclude that the 30{+-}10% higher than expected radiation fluxes from the 96 and 192 beam vacuum Hohlraums are attributable to differences in physics of the larger Hohlraums.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced Ion Adsorption on Mineral Nanoparticles

Classical molecular dynamics simulation was used to study the adsorption of Na + , Ca 2+ , Ba 2+ and Cl-ions on gibbsite edge (1 0 0), basal (0 0 1), and nanoparticle surfaces. The gibbsite nanoparticle consists of both basal and edge surfaces. Simulation results indicate that Na + and Cl - ions adsorb on both (1 0 0) and (0 0 1) surfaces as inner-sphere species (i.e., no water molecules between an ion and the surface). Outer-sphere Cl - ions (i.e., one water molecule between an ion and the surface) were also found on these surfaces. On the (1 0 0) edge, Ca 2+ ions adsorb as inner-sphere and outer-sphere complexes, while on the (0 0 1) surface outer-sphere Ca 2+ ions are the dominant species. Ba 2+ ions were found as inner-sphere and outer-sphere complexes on both surfaces. Calculated ion surface coverages indicate that, for all ions, surface coverages are always higher on the basal surface compared to the edge surface. More importantly, surface coverages for cations on the gibbsite nanoparticle are always higher than those calculated for (1 0 0) and (0 0 1) surfaces. This enhanced ion adsorption behavior for the nanoparticle is due to the significant number of inner-sphere cations found at nanoparticle corners. Outer-sphere cations do not contribute to the enhanced surface coverage. In addition, there is no ion adsorption enhancement observed for the Cl - ion. Our work provides a molecular-scale understanding of the relative significance of ion adsorption onto gibbsite basal versus edge surfaces and demonstrates the corner effect on ion adsorption on nanoparticles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Anti-gravity device

An educational toy useful in demonstrating fundamental concepts regarding the laws of gravity is described. The device comprises a sphere 10 of radius r resting on top of sphere 12 of radius R. The center of gravity of sphere 10 is displaced from its geometrical center by distance D. The dimensions are so related that D((R+r)/r) is greater than r. With the center of gravity of sphere 10 lying on a vertical line, the device is in equilibrium. When sphere 10 is rolled on the surface of sphere 12 it will return to its equilibrium position upon release. This creates an illusion that sphere 10 is defying the laws of gravity. In reality, due to the above noted relationship of D, R, and r, the center of gravity of sphere 10 rises from its equilibrium position as it rolls a short distance up or down the surface of sphere 12.

Palsingh, S.↗

Satellite (Timed, Aura, Aqua) and In Situ (Meteorological Rockets, Balloons) Measurement Comparability

Measurements using the inflatable falling sphere often are requested to provide density data in support of special sounding rocket launchings into the mesosphere and thermosphere. To insure density measurements within narrow time frames and close in space, the inflatable falling sphere is launched within minutes of the major test. Sphere measurements are reliable for the most part, however, availability of these rocket systems has become more difficult and, in fact, these instruments no longer are manufactured resulting in a reduction of the meager stockpile of instruments. Sphere measurements also are used to validate remotely measured temperatures and have the advantage of measuring small-scale atmospheric features. Even so, with the dearth of remaining falling spheres perhaps it is time to consider whether the remote measurements are mature enough to stand alone. Presented are two field studies, one in 2003 from Northern Sweden and one in 2010 from the vicinity of Kwajalein Atoll that compare temperature retrievals between satellite and in situ failing spheres. The major satellite instruments employed are SABER, MLS, and AIRS. The comparisons indicate that remotely measured temperatures mimic the sphere temperature measurements quite well. The data also confirm that satellite retrievals, while not always at the exact location required for individual studies, are adaptable enough and highly useful. Although the falling sphere will provide a measurement at a specific location and time, satellites only pass a given location daily or less often. This report reveals that averaged satellite measurements can provide temperatures and densities comparable to the falling sphere.

Schmidlin, F. J.↗

Ions confined in spherical dielectric cavities modeled by a splitting field-theory

The properties of ions confined within spherical dielectric cavities are examined by a splitting field-theory and Monte Carlo simulations. Three types of cavities are considered: one possessing a uniform surface charge density, one with a uniform volume charge density, and one containing mobile ions. In all cases, mobile counterions are present within the dielectric sphere. The splitting theory is based on dividing the electrostatic interaction into long- and short-wavelength contributions and applying different approximations on the two contributions. The splitting theory works well for the case where the dielectric constant of the confining sphere is equal to or less than that of the medium external to the sphere. Nevertheless, by extending the theory with a virial expansion, the predictions are improved. However, when the dielectric constant of the confining sphere is greater than that of the medium outside the sphere, the splitting theory performs poorly, only qualitatively agreeing with the simulation data. In this case, the strong-coupling expansion does not seem to work well, and a modified mean-field theory where the counterions interact directly with only their own image charge gives improved predictions. The splitting theory works best for the system with a uniform surface charge density and worst for the system with a uniform volume charge density. Increasing the number of ions within the sphere, at a fixed radius, tends to increase the ion density near the surface of the sphere and leads to a depletion region in the sphere interior; however, varying the ion number does not lead to any qualitative changes in the performance of the splitting theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A hardware investigation of robotic SPECT for functional and molecular imaging onboard radiation therapy systems

Purpose: To construct a robotic SPECT system and to demonstrate its capability to image a thorax phantom on a radiation therapy flat-top couch, as a step toward onboard functional and molecular imaging in radiation therapy. Methods: A robotic SPECT imaging system was constructed utilizing a gamma camera detector (Digirad 2020tc) and a robot (KUKA KR150 L110 robot). An imaging study was performed with a phantom (PET CT Phantom{sup TM}), which includes five spheres of 10, 13, 17, 22, and 28 mm diameters. The phantom was placed on a flat-top couch. SPECT projections were acquired either with a parallel-hole collimator or a single-pinhole collimator, both without background in the phantom and with background at 1/10th the sphere activity concentration. The imaging trajectories of parallel-hole and pinhole collimated detectors spanned 180° and 228°, respectively. The pinhole detector viewed an off-centered spherical common volume which encompassed the 28 and 22 mm spheres. The common volume for parallel-hole system was centered at the phantom which encompassed all five spheres in the phantom. The maneuverability of the robotic system was tested by navigating the detector to trace the phantom and flat-top table while avoiding collision and maintaining the closest possible proximity to the common volume. The robot base and tool coordinates were used for image reconstruction. Results: The robotic SPECT system was able to maneuver parallel-hole and pinhole collimated SPECT detectors in close proximity to the phantom, minimizing impact of the flat-top couch on detector radius of rotation. Without background, all five spheres were visible in the reconstructed parallel-hole image, while four spheres, all except the smallest one, were visible in the reconstructed pinhole image. With background, three spheres of 17, 22, and 28 mm diameters were readily observed with the parallel-hole imaging, and the targeted spheres (22 and 28 mm diameters) were readily observed in the pinhole region-of-interest imaging. Conclusions: Onboard SPECT could be achieved by a robot maneuvering a SPECT detector about patients in position for radiation therapy on a flat-top couch. The robot inherent coordinate frames could be an effective means to estimate detector pose for use in SPECT image reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reactivity and selectivity descriptors of dioxygen activation routes on metal oxides

The activation of dioxygen at typically isolated two-electron reduced centers can lead to the formation of electrophilic superoxo or peroxo species, providing an essential route to form reactive O 2 -derived species in biological, organometallic, and heterogeneous catalysts. Alternatively, O 2 activation can proceed via outer sphere routes, circumventing the formation of bound peroxo (OO*) species during oxidation catalysis by forming H 2 O 2 (g), which can react with another reduced center to form H 2 O. The electronic and binding properties of metal oxides that determine the relative rates of these activation routes are assessed here by systematic theoretical treatments using density functional theory (DFT). These methods are combined with conceptual frameworks based on thermochemical cycles and crossing potential models to assess the most appropriate descriptors for the activation barriers for each route using Keggin polyoxometalates as illustrative examples. In doing so, we show that inner sphere routes, which form OO* species via O 2 activation on the O-vacancies (*) formed in the reduction part of redox cycles, are mediated by early transition states that only weakly sense the oxide binding properties. Outer sphere routes form H 2 O 2 (g) via O 2 activation on OH pairs (H/OH*) formed by dissociation of H 2 O on O-vacancies; their rates and activation barriers reflect the rates of the first H-atom transfer from H/OH* to O 2 . The activation barriers for this H-transfer step depend on the binding energy of more weakly-bound H-atom in H/OH* pairs (HAE 2 ) and on the ˙OOH-surface interaction energy at its product state ($E_{int}$ 0 ). The $E_{int}$ 0 values are similar among oxides unless a large charge-balancing cation is present and interacts with radical ˙OOH; consequently, HAE 2 acts as an appropriate descriptor of the outer sphere dynamics. HAE 2 also determines the thermodynamics of H 2 O dissociation on O-vacancies, which influence the inner and outer sphere rates by setting the relative coverage of * and H/OH*. So these results, in turn, show that HAE 2 is a complete descriptor of the reactivity and selectivity of oxides for O 2 activation; the O-atoms in more reducible oxides (more negative HAE 2 ) exhibit a greater preference for the inner sphere routes and for the formation of electrophilic OO* intermediates that mediate epoxidation and O-insertion reactions during catalytic redox cycles. Large charge-balancing cations locally modify $E_{int}$ 0 values that determine the outer sphere rates and thus can be used to alter the preference of O-atoms to either inner or outer sphere routes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adsorption mechanisms of selenium oxyanions at the aluminum oxide/water interface

Sorption processes at the mineral/water interface typically control the mobility and bioaccessibility of many inorganic contaminants such as oxyanions. Selenium is an important micronutrient for human and animal health, but at elevated concentrations selenium toxicity is a concern. The objective of this study was to determine the bonding mechanisms of selenate (SeO{sub 4}{sup 2-}) and selenite (SeO{sub 3}{sup 2-}) on hydrous aluminum oxide (HAO) over a wide range of reaction pH using extended X-ray absorption fine structure (EXAFS) spectroscopy. Additionally, selenate adsorption on corundum ({alpha}-Al{sub 2}O{sub 3}) was studied to determine if adsorption mechanisms change as the aluminum oxide surface structure changes. The overall findings were that selenite forms a mixture of outer-sphere and inner-sphere bidentate-binuclear (corner-sharing) surface complexes on HAO, selenate forms primarily outer-sphere surface complexes on HAO, and on corundum selenate forms outer-sphere surface complexes at pH 3.5 but inner-sphere monodentate surface complexes at pH 4.5 and above. It is possible that the lack of inner-sphere complex formation at pH 3.5 is caused by changes in the corundum surface at low pH or secondary precipitate formation. The results are consistent with a structure-based reactivity for metal oxides, wherein hydrous metal oxides form outer-sphere complexes with sulfate and selenate, but inner-sphere monodentate surface complexes are formed between sulfate and selenate and {alpha}-Me{sub 2}O{sub 3}.

54 ENVIRONMENTAL SCIENCES↗

Dynamical separation of spherical bodies in supersonic flow

An experimental and computational investigation of the unsteady separation behaviour of two spheres in a highly supersonic flow is carried out. The spherical bodies, initially touching, are released with negligible relative velocity, an arrangement representing the idealized binary fragmentation of a meteoritic body in the atmosphere. In experiments performed in a Mach-4 Ludwieg tube, nylon spheres are initially suspended in the test section by weak threads and, following detachment of the threads by the arrival of the flow, fly freely according to the aerodynamic forces experienced. The resulting sphere motions and unsteady flow structures are recorded using high-speed shadowgraphy. The qualitative separation behaviour and the final lateral velocity of the smaller sphere are found to vary strongly with both the radius ratio and the initial alignment angle of the two spheres. More disparate radii and initial configurations in which the smaller sphere centre lies downstream of that of the larger sphere both increase the tendency for the smaller sphere to be entrained within the flow region bounded by the bow-shock of the larger body, rather than expelled from this region. At a critical angle for a given radius ratio (or a critical radius ratio for a given angle), transition from entrainment to expulsion occurs; at this critical value, the final lateral velocity is close to maximum due to the surfing effect noted by Laurence & Deiterding (J. Fluid Mech., vol. 676, 2011, pp. 396-431) at hypersonic Mach numbers. A high-precision tracking algorithm is used to provide quantitative comparisons between experiments and high-resolution inviscid numerical simulations, with generally favourable agreement.

Laurence, Stuart J↗

Molecular Dynamics Modeling of Ion Adsorption to the Basal Surfaces of Kaolinite

Molecular dynamics simulation is used to study the mechanisms involved in the adsorption of various ions to the basal surfaces of kaolinite. Analysis of simulation data indicates that cations and anions adsorb preferably on the siloxane and gibbsite surfaces of kaolinite, respectively. Strong inner-sphere adsorption of chlorine at aluminum vacancies on the gibbsite surface and the occurrence of chlorine-driven inner-sphere adsorption of cesium and sodium on the gibbsite surface for high ionic strengths are observed. Cesium ions form strong inner-sphere complexes at ditrigonal cavities on the siloxane surface. Outer-sphere cesium is highly mobile and only weak adsorption may occur. A small amount of sodium adsorbs on the siloxane surface as inner-sphere complexes at less clearly defined sites. Like cesium, sodium only forms very weak outer-sphere complexes on this surface. Inner-sphere complexes of cadmium and lead do not occur on either surface. Relatively strong outer-sphere cadmium and lead complexes are present on the siloxane surface at ditrigonal cavities.

74 ATOMIC AND MOLECULAR PHYSICS↗

van der Waals interaction between an atom and a spherical plasma shell

The van der Waals interaction energy of an atom with an infinitely thin sphere with finite conductivity is investigated in the framework of the hydrodynamic approach. Thin sphere models the fullerene. We put the sphere into a spherical cavity inside the infinite dielectric media then calculate the energy of vacuum fluctuations in the context of the {zeta}-function approach. The interaction energy for a single atom is obtained from this expression in the limit of the rare media. The Casimir-Polder expression for an atom and plate is recovered in the limit of the infinite radius of the sphere. Assuming a finite radius of the sphere, the interaction energy of an atom falls down to a third power of distance between the atom and sphere for short distances and to a seventh power for large distances from the sphere. Numerically the interaction energy is 3.8 eV for the hydrogen atom placed on the surface of the sphere with parameters of fullerene C{sub 60}. We also show that the polarizability of fullerene is merely a cube of its radius.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

LANL studies of ESD spark energy discharge through September 2019

Two concentric-sphere apparatuses were used to measure the energies deposited by electric sparks through air to calibrated loads. Both sets of spheres had clean, uninsulated metal surfaces. The 127-mm diameter pair of spheres had a gap of 10 mm and a capacitance of 52 pF. The maximum energy stored on these spheres was 12 mJ and the maximum energy delivered to the 50-mΩ load was 11 µJ, with or without inductance. This load energy amounted to 0.09% of the available input energy; the remainder of the input energy was expended in forming the spark. The second set of spheres was 330 mm in diameter with a gap of 14 mm and a capacitance of 240 pF. The maximum energy stored on these spheres was 71 mJ and the maximum energy delivered to the 50-mΩ load was 150 µJ without added inductance. This load energy was 0.27% of the input energy; again, the remainder of the input energy was expended in forming the spark. The inclusion of 250 nH and 500 nH inductances in the discharge path of the smaller spheres caused the current discharges to resonate, but had little effect on the maximum energies deposited in the loads. At the time of writing, inductances had not yet been added to the larger spheres. The magnitudes of the observed spark discharges were stochastic, so more than 1200 tests were required to develop the statistical bounds of the spark behavior, i.e., to estimate the worst case (highest likely) energy depositions in the loads. The action integrals of the current discharges $∫ i^2dt$ were found to be approximately independent of the load resistances for loads of less than ~1 Ω. Hence the energy deposition scaled with resistance as 207 µJ/Ω and 2.93 mJ/Ω for the two apparatuses.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Development and fabrication of insulator seals for thermionic diodes

Eight different types of cermet seals for thermionic diodes were investigated: (1) 1 micron Al2O3 with Nb spheres; (2) 200 A Al2O3 with Nb spheres; (3) 1 micron Al2O3 with Nb 1% Zr spheres; (4) 200 A Al2O3 with Nb 1% Zr spheres; (5) Pure Y2O3 with Nb 1% Zr spheres; (6) Y2O3 3% ZrO2 with Nb 1% Zr spheres; (7) Y2O3 10% ZrO2 with Nb 1% Zr spheres; and (8) ZrO2 12% Y2O3 with Nb 1% Zr spheres. Investigations were made to determine the most favorable fabrication techniques and the effect of the bonding cycle, (length of bonding time and shutdown sequences). The analysis of the seals included tensile test, vacuum test, electrical test and metallurgical examination. At the conclusion of the development phase, 36 seals were fabricated for delivery for evaluation.

Poirier, V. L.↗

Temporal study of the current collected by a Langmuir probe biased to high voltages in the wake behind a conducting body

The temporal evolution of the voltage-current characteristic of a spherical Langmuir probe in the near-wake region of a conducting body is investigated in a pulsed plasma device. Measurements of the current collected by a sphere placed on axis behind a conducting disk are presented as a function of the bias voltage and time. The bias voltage on the collecting sphere is large enough, ranging from +500 to -3000 V, to attract ions or electrons across the wake region. In addition, plasma potential profiles as a function of sphere bias voltage and time throughout the nearwake and midwake region are presented. It is found that for a negative sphere bias a threshold voltage exists for current collection. This threshold voltage decreases during the formation of the wake behind the conducting disk. Potential measurements indicate that the sheath region around the negatively biased sphere contracts as the wake region establishes itself. This contraction of the sheath region increases the electric field attracting ions to the sphere and decreases the threshold voltage for current collection. For positive sphere bias voltage the current collected by the sphere does not exhibit a threshold voltage but is monotonically increasing.

Meassick, S.↗

Radiometric Measurement Comparisons Using Transfer Radiometers in Support of the Calibration of NASA's Earth Observing System (EOS) Sensors

EOS satellite instruments operating in the visible through the shortwave infrared wavelength regions (from 0.4 micrometers to 2.5 micrometers) are calibrated prior to flight for radiance response using integrating spheres at a number of instrument builder facilities. The traceability of the radiance produced by these spheres with respect to international standards is the responsibility of the instrument builder, and different calibration techniques are employed by those builders. The National Aeronautics and Space Administration's (NASA's) Earth Observing System (EOS) Project Science Office, realizing the importance of preflight calibration and cross-calibration, has sponsored a number of radiometric measurement comparisons, the main purpose of which is to validate the radiometric scale assigned to the integrating spheres by the instrument builders. This paper describes the radiometric measurement comparisons, the use of stable transfer radiometers to perform the measurements, and the measurement approaches and protocols used to validate integrating sphere radiances. Stable transfer radiometers from the National Institute of Standards and Technology, the University of Arizona Optical Sciences Center Remote Sensing Group, NASA's Goddard Space Flight Center, and the National Research Laboratory of Metrology in Japan, have participated in these comparisons. The approaches used in the comparisons include the measurement of multiple integrating sphere lamp levels, repeat measurements of select lamp levels, the use of the stable radiometers as external sphere monitors, and the rapid reporting of measurement results. Results from several comparisons are presented. The absolute radiometric calibration standard uncertainties required by the EOS satellite instruments are typically in the +/- 3% to +/- 5% range. Preliminary results reported during eleven radiometric measurement comparisons held between February 1995 and May 1998 have shown the radiance of integrating spheres agreed to within +/- 2.5% from the average at blue wavelengths and to within +/- 1.7% from the average at red and near infrared wavelengths. This level of agreement lends confidence in the use of the transfer radiometers in validating the radiance scales assigned by EOS instrument calibration facilities to their integrating sphere sources.

Butler, James J.↗

Synchronized Position Hold, Engage, Reorient, Experimental Satellites

Synchronized Position Hold, Engage, Reorient, Experimental Satellites (SPHERES) are bowling-ball sized spherical satellites. They will be used inside the space station to test a set of well-defined instructions for spacecraft performing autonomous rendezvous and docking maneuvers. Three free-flying spheres will fly within the cabin of the station, performing flight formations. Each satellite is self-contained with power, propulsion, computers and navigation equipment. The results are important for satellite servicing, vehicle assembly and formation flying spacecraft configurations. SPHERES is a testbed for formation flying by satellites, the theories and calculations that coordinate the motion of multiple bodies maneuvering in microgravity. To achieve this inside the ISS cabin, bowling-ball-sized spheres perform various maneuvers (or protocols), with one to three spheres operating simultaneously . The Synchronized Position Hold, Engage, Reorient, Experimental Satellites (SPHERES) experiment will test relative attitude control and station-keeping between satellites, re-targeting and image plane filling maneuvers, collision avoidance and fuel balancing algorithms, and an array of geometry estimators used in various missions. SPHERES consists of three self-contained satellites, which are 18 sided polyhedrons that are 0.2 meter in diameter and weigh 3.5 kilograms. Each satellite contains an internal propulsion system, power, avionics, software, communications, and metrology subsystems. The propulsion system uses CO2, which is expelled through the thrusters. SPHERES satellites are powered by AA batteries. The metrology subsystem provides real-time position and attitude information. To simulate ground station-keeping, a laptop will be used to transmit navigational data and formation flying algorithms. Once these data are uploaded, the satellites will perform autonomously and hold the formation until a new command is given.

Miller, David W.↗

Comparison of Temperature Measurements in the Middle Atmosphere by Satellite with Profiles Obtained by Meteorological Rockets

Measurements using the inflatable falling sphere technique have occasionally been used to obtain temperature results from density data and thereby provide comparison with temperature profiles obtained by satellite sounders in the mesosphere and stratosphere. To insure density measurements within narrow time frames and close in space, the inflatable falling sphere is launched within seconds of the nearly overhead satellite pass. Sphere measurements can be used to validate remotely measured temperatures but also have the advantage of measuring small-scale atmospheric features. Even so, with the dearth of remaining falling spheres available (the manufacture of these systems has been discontinued), it may be time to consider whether the remote measurements are mature enough to stand alone. Three field studies are considered, one in 2003 from Northern Sweden, and two in 2010 from the vicinity of Kwajalein Atoll in the South Pacific and from Barking Sands, Hawaii. All three sites are used to compare temperature retrievals between satellite and in situ falling spheres. The major satellite instruments employed are SABER, MLS, and AIRS. The comparisons indicate that remotely measured temperatures mimic the sphere temperature measurements quite well. The data also confirm that satellite retrievals, while not always at the exact location required for detailed studies in space and time, compare sufficiently well to be highly useful. Although the falling sphere will provide a measurement at a specific location and time, satellites only pass a given location daily or less frequently. This report reveals that averaged satellite measurements can provide temperatures and densities comparable to those obtained from the falling sphere, thereby providing a reliable measure of global temperature

Goldberg, Richard A.↗