Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “S Parameters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Dynamic Contrast-Enhanced MRI in Head-and-Neck Cancer: The Impact of Region of Interest Selection on the Intra- and Interpatient Variability of Pharmacokinetic Parameters

Purpose: Dynamic contrast-enhanced (DCE) MRI-extracted parameters measure tumor microvascular physiology and are usually calculated from an intratumor region of interest (ROI). Optimal ROI delineation is not established. The valid clinical use of DCE-MRI requires that the variation for any given parameter measured within a tumor be less than that observed between tumors in different patients. This work evaluates the impact of tumor ROI selection on the assessment of intra- and interpatient variability. Method and Materials: Head and neck cancer patients received initial targeted therapy (TT) treatment with erlotinib and/or bevacizumab, followed by radiotherapy and concurrent cisplatin with synchronous TT. DCE-MRI data from Baseline and the end of the TT regimen (Lead-In) were analyzed to generate the vascular transfer function (K{sup trans}), the extracellular volume fraction (v{sub e}), and the initial area under the concentration time curve (iAUC{sub 1min}). Four ROI sampling strategies were used: whole tumor or lymph node (Whole), the slice containing the most enhancing voxels (SliceMax), three slices centered in SliceMax (Partial), and the 5% most enhancing contiguous voxels within SliceMax (95Max). The average coefficient of variation (aCV) was calculated to establish intrapatient variability among ROI sets and interpatient variability for each ROI type. The average ratio between each intrapatient CV and the interpatient CV was calculated (aRCV). Results: Baseline primary/nodes aRCVs for different ROIs not including 95Max were, for all three MR parameters, in the range of 0.14-0.24, with Lead-In values between 0.09 and 0.2, meaning a low intrapatient vs. interpatient variation. For 95Max, intrapatient CVs approximated interpatient CVs, meaning similar data dispersion and higher aRCVs (0.6-1.27 for baseline) and 0.54-0.95 for Lead-In. Conclusion: Distinction between different patient's primary tumors and/or nodes cannot be made using 95Max ROIs. The other three strategies are viable and equivalent for using DCE-MRI to measure head and neck cancer physiology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Dosimetric Parameters Associated With Acute Gastrointestinal Toxicity and Upper Gastrointestinal Bleeding in Locally Advanced Pancreatic Cancer Patients Treated With Gemcitabine-Based Concurrent Chemoradiotherapy

Purpose: To identify the dosimetric parameters associated with gastrointestinal (GI) toxicity in patients with locally advanced pancreatic cancer (LAPC) treated with gemcitabine-based chemoradiotherapy. Methods and Materials: The data from 40 patients were analyzed retrospectively. Chemoradiotherapy consisted of conventional fractionated three-dimensional radiotherapy and weekly gemcitabine. Treatment-related acute GI toxicity and upper GI bleeding (UGB) were graded according to the Common Toxicity Criteria Adverse Events, version 4.0. The dosimetric parameters (mean dose, maximal absolute dose which covers 2 cm{sup 3} of the organ, and absolute volume receiving 10-50 Gy [V{sub 10-50}]) of the stomach, duodenum, small intestine, and a composite structure of the stomach and duodenum (StoDuo) were obtained. The planning target volume was also obtained. Univariate analyses were performed to identify the predictive factors for the risk of grade 2 or greater acute GI toxicity and grade 3 or greater UGB, respectively. Results: The median follow-up period was 15.7 months (range, 4-37). The actual incidence of acute GI toxicity was 33%. The estimated incidence of UGB at 1 year was 20%. Regarding acute GI toxicity, a V{sub 50} of {>=}16 cm{sup 3} of the stomach was the best predictor, and the actual incidence in patients with V{sub 50} <16 cm{sup 3} of the stomach vs. those with V{sub 50} of {>=}16 cm{sup 3} was 9% vs. 61%, respectively (p = 0.001). Regarding UGB, V{sub 50} of {>=}33 cm{sup 3} of the StoDuo was the best predictor, and the estimated incidence at 1 year in patients with V{sub 50} <33 cm{sup 3} of the StoDuo vs. those with V{sub 50} {>=}33 cm{sup 3} was 0% vs. 44%, respectively (p = 0.002). The dosimetric parameters correlated highly with one another. Conclusion: The irradiated absolute volume of the stomach and duodenum are important for the risk of acute GI toxicity and UGB. These results could be helpful in escalating the radiation doses using novel techniques, such as intensity-modulated radiotherapy, for the treatment of pancreatic cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combining Physical and Biologic Parameters to Predict Radiation-Induced Lung Toxicity in Patients With Non-Small-Cell Lung Cancer Treated With Definitive Radiation Therapy

Purpose: To investigate the plasma dynamics of 5 proinflammatory/fibrogenic cytokines, including interleukin-1beta (IL-1{beta}), IL-6, IL-8, tumor necrosis factor alpha (TNF-{alpha}), and transforming growth factor beta1 (TGF-{beta}1) to ascertain their value in predicting radiation-induced lung toxicity (RILT), both individually and in combination with physical dosimetric parameters. Methods and Materials: Treatments of patients receiving definitive conventionally fractionated radiation therapy (RT) on clinical trial for inoperable stages I-III lung cancer were prospectively evaluated. Circulating cytokine levels were measured prior to and at weeks 2 and 4 during RT. The primary endpoint was symptomatic RILT, defined as grade 2 and higher radiation pneumonitis or symptomatic pulmonary fibrosis. Minimum follow-up was 18 months. Results: Of 58 eligible patients, 10 (17.2%) patients developed RILT. Lower pretreatment IL-8 levels were significantly correlated with development of RILT, while radiation-induced elevations of TGF-ss1 were weakly correlated with RILT. Significant correlations were not found for any of the remaining 3 cytokines or for any clinical or dosimetric parameters. Using receiver operator characteristic curves for predictive risk assessment modeling, we found both individual cytokines and dosimetric parameters were poor independent predictors of RILT. However, combining IL-8, TGF-ss1, and mean lung dose into a single model yielded an improved predictive ability (P<.001) compared to either variable alone. Conclusions: Combining inflammatory cytokines with physical dosimetric factors may provide a more accurate model for RILT prediction. Future study with a larger number of cases and events is needed to validate such findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Effect of Dose-Volume Parameters and Interfraction Interval on Cosmetic Outcome and Toxicity After 3-Dimensional Conformal Accelerated Partial Breast Irradiation

Purpose: To evaluate dose-volume parameters and the interfraction interval (IFI) as they relate to cosmetic outcome and normal tissue effects of 3-dimensional conformal radiation therapy (3D-CRT) for accelerated partial breast irradiation (APBI). Methods and Materials: Eighty patients were treated by the use of 3D-CRT to deliver APBI at our institutions from 2003-2010 in strict accordance with the specified dose-volume constraints outlined in the National Surgical Adjuvant Breast and Bowel Project B39/Radiation Therapy Oncology Group 0413 (NSABP-B39/RTOG 0413) protocol. The prescribed dose was 38.5 Gy in 10 fractions delivered twice daily. Patients underwent follow-up with assessment for recurrence, late toxicity, and overall cosmetic outcome. Tests for association between toxicity endpoints and dosimetric parameters were performed with the chi-square test. Univariate logistic regression was used to evaluate the association of interfraction interval (IFI) with these outcomes. Results: At a median follow-up time of 32 months, grade 2-4 and grade 3-4 subcutaneous fibrosis occurred in 31% and 7.5% of patients, respectively. Subcutaneous fibrosis improved in 5 patients (6%) with extended follow-up. Fat necrosis developed in 11% of women, and cosmetic outcome was fair/poor in 19%. The relative volume of breast tissue receiving 5%, 20%, 50%, 80%, and 100% (V5-V100) of the prescribed dose was associated with risk of subcutaneous fibrosis, and the volume receiving 50%, 80%, and 100% (V50-V100) was associated with fair/poor cosmesis. The mean IFI was 6.9 hours, and the minimum IFI was 6.2 hours. The mean and minimum IFI values were not significantly associated with late toxicity. Conclusions: The incidence of moderate to severe late toxicity, particularly subcutaneous fibrosis and fat necrosis and resulting fair/poor cosmesis, remains high with continued follow-up. These toxicity endpoints are associated with several dose-volume parameters. Minimum and mean IFI values were not associated with late toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Estimation of a Self-Consistent Set of Radiobiological Parameters From Hypofractionated Versus Standard Radiation Therapy of Prostate Cancer

Purpose: To determine a self-consistent set of radiobiological parameters in prostate cancer. Methods and Materials: A method to estimate intrinsic radiosensitivity (α), fractionation sensitivity (α/β), repopulation doubling time, number of clonogens, and kick-off time for accelerated repopulation of prostate cancer has been developed. Based on the generalized linear-quadratic model and without assuming the isoeffective hypothesis, the potential applications of the method were investigated using the clinical outcome of biochemical relapse-free survival recently reviewed in the literature. The strengths and limitations of the method, regarding the fitted parameters and 95% confidence intervals (CIs), are also discussed. Results: Our best estimate of α/β is 2.96 Gy (95% CI 2.41-3.53 Gy). The corresponding α value is 0.16 Gy{sup −1} (95% CI 0.14-0.18 Gy{sup −1}), which is compatible with a realistic number of clonogens: 6.5 × 10{sup 6} (95% CI 1.5 × 10{sup 6}-2.1 × 10{sup 7}). The estimated cell doubling time is 5.1 days (95% CI 4.2-7.2 days), very low if compared with that reported in the literature. This corresponds to the dose required to offset the repopulation occurring in 1 day of 0.52 Gy/d (95% CI 0.32-0.68 Gy/d). However, a long kick-off time of 31 days (95% CI 22-41 days) from the start of radiation therapy was found. Conclusion: The proposed analytic/graphic method has allowed the fitting of clinical data, providing a self-consistent set of radiobiological parameters for prostate cancer. With our analysis we confirm a low value for α/β with a correspondingly high value of intrinsic radiosensitivity, a realistic average number of clonogens, a long kick-off time for accelerated repopulation, and a surprisingly fast repopulation that suggests the involvement of subpopulations of specifically tumorigenic stem cells during continuing radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volume-Based Parameters of {sup 18}F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Improve Disease Recurrence Prediction in Postmastectomy Breast Cancer Patients With 1 to 3 Positive Axillary Lymph Nodes

Purpose: To determine whether volume-based parameters on pretreatment {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography in breast cancer patients treated with mastectomy without adjuvant radiation therapy are predictive of recurrence. Methods and Materials: We retrospectively analyzed 93 patients with 1 to 3 positive axillary nodes after surgery, who were studied with {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography for initial staging. We evaluated the relationship between positron emission tomography parameters, including the maximum standardized uptake value, metabolic tumor volume (MTV), and total lesion glycolysis (TLG), and clinical outcomes. Results: The median follow-up duration was 45 months. Recurrence was observed in 11 patients. Metabolic tumor volume and TLG were significantly related to tumor size, number of involved nodes, nodal ratio, nuclear grade, estrogen receptor (ER) status, and triple negativity (TN) (all P values were <.05). In receiver operating characteristic curve analysis, MTV and TLG showed better predictive performance than tumor size, ER status, or TN (area under the curve: 0.85, 0.86, 0.79, 0.74, and 0.74, respectively). On multivariate analysis, MTV was an independent prognostic factor of locoregional recurrence-free survival (hazard ratio 34.42, 95% confidence interval 3.94-882.71, P=.0008) and disease-free survival (DFS) (hazard ratio 13.92, 95% confidence interval 2.65-103.78, P=.0018). The 3-year DFS rate was 93.8% for the lower MTV group (<53.1; n=85) and 25.0% for the higher MTV group (≥53.1; n=8; P<.0001, log–rank test). The 3-year DFS rate for patients with both ER-positive status and MTV <53.1 was 98.2%; and for those with ER-negative status and MTV ≥53.1 it was 25.0% (P<.0001). Conclusions: Volume-based parameters improve recurrence prediction in postmastectomy breast cancer patients with 1 to 3 positive nodes. The addition of MTV to ER status or TN has potential benefits to identify a subgroup at higher risk for recurrence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling Pathologic Response of Esophageal Cancer to Chemoradiation Therapy Using Spatial-Temporal {sup 18}F-FDG PET Features, Clinical Parameters, and Demographics

Purpose: To construct predictive models using comprehensive tumor features for the evaluation of tumor response to neoadjuvant chemoradiation therapy (CRT) in patients with esophageal cancer. Methods and Materials: This study included 20 patients who underwent trimodality therapy (CRT + surgery) and underwent {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) both before and after CRT. Four groups of tumor features were examined: (1) conventional PET/CT response measures (eg, standardized uptake value [SUV]{sub max}, tumor diameter); (2) clinical parameters (eg, TNM stage, histology) and demographics; (3) spatial-temporal PET features, which characterize tumor SUV intensity distribution, spatial patterns, geometry, and associated changes resulting from CRT; and (4) all features combined. An optimal feature set was identified with recursive feature selection and cross-validations. Support vector machine (SVM) and logistic regression (LR) models were constructed for prediction of pathologic tumor response to CRT, cross-validations being used to avoid model overfitting. Prediction accuracy was assessed by area under the receiver operating characteristic curve (AUC), and precision was evaluated by confidence intervals (CIs) of AUC. Results: When applied to the 4 groups of tumor features, the LR model achieved AUCs (95% CI) of 0.57 (0.10), 0.73 (0.07), 0.90 (0.06), and 0.90 (0.06). The SVM model achieved AUCs (95% CI) of 0.56 (0.07), 0.60 (0.06), 0.94 (0.02), and 1.00 (no misclassifications). With the use of spatial-temporal PET features combined with conventional PET/CT measures and clinical parameters, the SVM model achieved very high accuracy (AUC 1.00) and precision (no misclassifications)—results that were significantly better than when conventional PET/CT measures or clinical parameters and demographics alone were used. For groups with many tumor features (groups 3 and 4), the SVM model achieved significantly higher accuracy than did the LR model. Conclusions: The SVM model that used all features including spatial-temporal PET features accurately and precisely predicted pathologic tumor response to CRT in esophageal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined Ventilation and Perfusion Imaging Correlates With the Dosimetric Parameters of Radiation Pneumonitis in Radiation Therapy Planning for Lung Cancer

Purpose: The purpose of this study was to prospectively investigate clinical correlations between dosimetric parameters associated with radiation pneumonitis (RP) and functional lung imaging. Methods and Materials: Functional lung imaging was performed using four-dimensional computed tomography (4D-CT) for ventilation imaging, single-photon emission computed tomography (SPECT) for perfusion imaging, or both (V/Q-matched region). Using 4D-CT, ventilation imaging was derived from a low attenuation area according to CT numbers below different thresholds (vent-860 and -910). Perfusion imaging at the 10th, 30th, 50th, and 70th percentile perfusion levels (F10-F70) were defined as the top 10%, 30%, 50%, and 70% hyperperfused normal lung, respectively. All imaging data were incorporated into a 3D planning system to evaluate correlations between RP dosimetric parameters (where fV20 is the percentage of functional lung volume irradiated with >20 Gy, or fMLD, the mean dose administered to functional lung) and the percentage of functional lung volume. Radiation pneumonitis was evaluated using Common Terminology Criteria for Adverse Events version 4.0. Statistical significance was defined as a P value of <.05. Results: Sixty patients who underwent curative radiation therapy were enrolled (48 patients for non-small cell lung cancer, and 12 patients for small cell lung cancer). Grades 1, 2, and ≥3 RP were observed in 16, 44, and 6 patients, respectively. Significant correlations were observed between the percentage of functional lung volume and fV20 (r=0.4475 in vent-860 and 0.3508 in F30) or fMLD (r=0.4701 in vent-860 and 0.3128 in F30) in patients with grade ≥2 RP. F30∩vent-860 results exhibited stronger correlations with fV20 and fMLD in patients with grade ≥2 (r=0.5509 in fV20 and 0.5320 in fMLD) and grade ≥3 RP (r=0.8770 in fV20 and 0.8518 in fMLD). Conclusions: RP dosimetric parameters correlated significantly with functional lung imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Towards operational atmospheric correction of airborne hyperspectral imaging spectroscopy: Algorithm evaluation, key parameter analysis, and machine learning emulators

Atmospheric correction of airborne hyperspectral imaging spectroscopy (AHIS) to obtain high-quality surface reflectance is the prerequisite for remote sensing applications. Over the last decades, different atmospheric correction methods have been developed based on radiative transfer models (RTMs), however, the relative performances of different algorithms are unclear. Automated operational atmospheric correction methods to process large-volume AHIS data in a high-accurate and high-throughput manner are still lacking. Therefore, this study proposed an operational atmospheric correction pipeline for deriving surface reflectance from AHIS data. To ensure the accuracy and efficiency of the pipeline, we focused on three specific aspects: (1) selecting a suitable RTM for the development of atmospheric lookup tables (LUTs) by comparing the commercial MODerate resolution atmospheric TRANsmission (MODTRAN) and open-sourced Library for Radiative TRANsfer (LibRadTRAN) models, where the widely-used software, Atmospheric/Topographic Correction for Airborne Imagery (ATCOR), was used as benchmarks; (2) identifying key atmospheric correction parameters and determining suitable sources for parameter retrievals including AHIS, Moderate Resolution Imaging Spectroradiometer (MODIS), and AErosol RObotic NETwork (AERONET); and (3) testing the performance of using machine learning emulators to speed up the RTM-based atmospheric correction. Results indicate that (1) atmospheric correction based on MODTRAN LUTs can produce surface reflectance accurately with mean absolute errors < 0.05 and cosine similarities > 0.98 compared to field measurements, which is comparable to the software ATCOR and slightly outperforms the LibRadTRAN LUTs; (2) sobol global sensitivity analysis demonstrates that in the atmospheric correction, visibility and water vapor are two key parameters that can be accurately derived from AHIS in contrast to MODIS or AERONET data; and (3) Random Forest emulators can produce accurate estimations of surface reflectance with mean absolute errors < 0.03 and cosine similarities > 0.98 for higher processing efficiency and determine a suitable set of wavelengths for retrieving atmospheric visibility and water vapor. In conclusion, the proposed atmospheric correction pipeline also improved the four-stream radiative transfer theory for airborne applications by considering adjacent effects from airborne surrounding pixels and can also be applied for atmospheric correction of hyperspectral data from spaceborne missions.

47 OTHER INSTRUMENTATION↗

Consequences of product inhibition in the quantification of kinetic parameters

While the potential for product inhibition in catalytic reactions is well known, the impact of neglected inhibition on measured kinetic parameters is often overlooked. The presence of product inhibition, most often caused by the competitive adsorption of products with reactants on catalytic active sites, is difficult to determine a priori for an arbitrary catalytic system. The significance of product inhibition relies on the concentration of the products, their adsorption thermodynamics on catalytically relevant sites, and process parameters such as temperature and pressure. When inhibition is significant, however, apparent activation energies and reaction orders vary from the differential-reactor apparent activation energy by a factor of 1/(1 - δ), where δ is the total inhibition order (e.g., the factor (1 - δ) = 1.6 for a system with product inhibition of -0.6 order). This is illustrated here with the kinetics of NO oxidation over Cu ion clusters (Cu x O y ) in Cu-SSZ-13, for which the product NO 2 inhibits the forward reaction. Furthermore, in the presence of inhibition, when only reactants are fed to a flow reactor or placed in a batch reactor, there is often no practical conversion that is low enough to guarantee differential behavior. Inclusion of products in the feed solves this problem, allowing accurate determination of kinetic parameters such as apparent reaction orders and activation energies. We also demonstrate that evaluation of the necessity of co-feeding products to assure measurement of differential-reactor data in a given catalytic system is straightforward from a plot of the log of the rate (or conversion) versus the log of the space time in a flow reactor or elapsed time in a batch reactor. We encourage inclusion of this test in all kinetic analyses that are reasonably approximated by power law rate expressions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An iterative stochastic ensemble method for parameter estimation of subsurface flow models

Parameter estimation for subsurface flow models is an essential step for maximizing the value of numerical simulations for future prediction and the development of effective control strategies. We propose the iterative stochastic ensemble method (ISEM) as a general method for parameter estimation based on stochastic estimation of gradients using an ensemble of directional derivatives. ISEM eliminates the need for adjoint coding and deals with the numerical simulator as a blackbox. The proposed method employs directional derivatives within a Gauss–Newton iteration. The update equation in ISEM resembles the update step in ensemble Kalman filter, however the inverse of the output covariance matrix in ISEM is regularized using standard truncated singular value decomposition or Tikhonov regularization. We also investigate the performance of a set of shrinkage based covariance estimators within ISEM. The proposed method is successfully applied on several nonlinear parameter estimation problems for subsurface flow models. The efficiency of the proposed algorithm is demonstrated by the small size of utilized ensembles and in terms of error convergence rates.

97 MATHEMATICS AND COMPUTING↗

Computation of probabilistic hazard maps and source parameter estimation for volcanic ash transport and dispersion

Volcanic ash advisory centers are charged with forecasting the movement of volcanic ash plumes, for aviation, health and safety preparation. Deterministic mathematical equations model the advection and dispersion of these plumes. However initial plume conditions – height, profile of particle location, volcanic vent parameters – are known only approximately at best, and other features of the governing system such as the windfield are stochastic. These uncertainties make forecasting plume motion difficult. As a result of these uncertainties, ash advisories based on a deterministic approach tend to be conservative, and many times over/under estimate the extent of a plume. This paper presents an end-to-end framework for generating a probabilistic approach to ash plume forecasting. This framework uses an ensemble of solutions, guided by Conjugate Unscented Transform (CUT) method for evaluating expectation integrals. This ensemble is used to construct a polynomial chaos expansion that can be sampled cheaply, to provide a probabilistic model forecast. The CUT method is then combined with a minimum variance condition, to provide a full posterior pdf of the uncertain source parameters, based on observed satellite imagery. The April 2010 eruption of the Eyjafjallajökull volcano in Iceland is employed as a test example. The puff advection/dispersion model is used to hindcast the motion of the ash plume through time, concentrating on the period 14–16 April 2010. Variability in the height and particle loading of that eruption is introduced through a volcano column model called bent. Output uncertainty due to the assumed uncertain input parameter probability distributions, and a probabilistic spatial-temporal estimate of ash presence are computed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The dependence of aluminum lattice orientation on semiconductor lattice parameter in planar InAs/Al hybrid heterostructures

We present a detailed study of 7-nm thick Al layers epitaxially grown on In x Al 1-x As or Al 1-x Ga x Sb y As 1-y (0 0 1) semiconductors using high-resolution transmission electron microscopy (HRTEM) and synchrotron X-ray diffraction (XRD). These techniques provide high spatial and high reciprocal space resolution information about Al lattice orientations and interfacial structure, highlighting the existence of a strong correlation between the surface lattice parameter of the semiconductor and the normal orientation of the aluminum film. The normal orientation of Al layers is found to be [1 1 1] when the in-plane semiconductor surface lattice parameter, a S , is smaller than 5.98 Å, and is [1 1 0] when aS is larger than this value. In the transition between these lattice parameters where one orientation is preferred, both orientations may be observed. Concomitant with the change in normal orientation is an inversion in the strain state of the aluminum film. When the normal orientation is [1 1 1], the Al film is compressively strained; while for [1 1 0] normal orientations, the Al in-plane strain is tensile. An energy balance model, accounting for surface, interfacial, side-face, and strain energy, and the registry of lattice planes across the semiconductor/aluminum interface provide explanations for the observed normal orientation and strain inversion.

36 MATERIALS SCIENCE↗

Explicitly integrating parameter, input, and structure uncertainties into Bayesian Neural Networks for probabilistic hydrologic forecasting

Estimating uncertainty of hydrologic forecasting is valuable to water resources and other relevant decision making processes. Recently, Bayesian Neural Networks (BNNs) have been proved powerful tools for quantifying uncertainty of streamflow forecasting. In this study, we propose a Markov Chain Monte Carlo (MCMC) framework to incorporate the uncertainties associated with input, model structure, and parameter into BNNs. This framework allows the structure of the neural networks to change by removing or adding connections between neurons and enables scaling of input data by using rainfall multipliers. The results show that the new BNNs outperform the BNNs that only consider uncertainties associated with parameter and model structure. Critical evaluation of posterior distribution of neural network weights, number of effective connections, rainfall multipliers, and hyper-parameters show that the assumptions held in our BNNs are not well supported. Further understanding of characteristics of different uncertainty sources and including output error into the MCMC framework are expected to enhance the application of neural networks for uncertainty analysis of hydrologic forecasting.

58 GEOSCIENCES↗

Stability boundary and optimal operating parameter identification in milling using Bayesian learning

Here, this paper describes a novel Bayesian learning approach for stability boundary and optimal parameter identification in milling without the knowledge of the underlying tool dynamics or material cutting force coefficients. The paper is divided into two parts. First, a Bayesian learning method for stability lobe identification using test results is described. Each axial depth and spindle speed combination is characterized by a probability of stability which is updated using Bayes’ rule when a test result (stable or unstable) is made available. A novel likelihood function is defined which incorporates knowledge of the stability behavior. Numerical results show convergence to the analytical stability lobe diagram. Second, an adaptive experimental strategy to identify optimal operating parameters that maximize material removal rate is described. Numerical evaluation shows convergence to the optimal operating point with error less than 15 % within ten tests on average. The approach is validated using experimental results. Results show that the proposed method is an efficient and robust learning method to identify the stability lobe diagram and optimal operating parameters with a limited number of tests/data points.

Bayesian machine learning↗

Effect of printing parameters on 3D-printed carbon fiber-reinforced polymer composites under magnetic field control

Magnetic field controlled (MFC) 3D printing is a promising method for realizing the intelligent control of the structural performance of carbon fiber-reinforced plastic (CFRP) composites by adjusting the fiber orientation during the printing process. However, few studies have focused on the influence of the printing parameters on the magnetic control of the fiber direction. Therefore, in this study, the mechanical properties and internal fiber distributions of MFC 3D-printed samples of CFRP composites with 10 wt% fiber content, which were printed at different speeds and layer thicknesses, were investigated. Subsequently, the effects of the fiber content on the mechanical properties and fiber distribution of the MFC 3D-printed samples were studied. Furthermore, the origin of fiber fracture was evaluated through observation and analysis of the fracture section using scanning electron microscopy. The fiber orientation could be well adjusted under the action of a magnetic field and adjustment of printing parameters, thereby improving the tensile strength, young's modulus significantly with slightly decrease of fracture elongation. The recommended parameter combinations (printing speed and layer thickness) were 40 mm/s and 0.2 mm for 10 wt% fiber content CFRP composites.

36 MATERIALS SCIENCE↗

Effect of threshold parameters on infrared segmentation methods for porosity detection in electron beam powder bed fusion

In-situ process monitoring has seen significant interest in additive manufacturing to address qualification and certification goals. This is especially prevalent in metal powder bed fusion processes such as electron beam powder bed fusion (PBF-EB), with layer-wise infrared imaging being commonly used to detect defects. Here, this work compares two different segmentation methods (static thresholding and statistical thresholding) used for detecting porosity from in-situ infrared imaging data for PBF-EB. Samples were manufactured at a variety of focus offset values to induce porosity. Then, the segmented infrared images were compared to ex-situ X-ray computed tomography scans, which served as a ground-truth reference for objective evaluation. Through this analysis framework, the influential parameters, static threshold and N-value (number of standard deviations above the mean pixel value), respectively, for both image segmentation methods were analyzed and compared for their effects on porosity detection. With optimal parameter settings, the two methods had similar porosity detection performance, but the statistical method performed better under a larger variety of parameter settings.

Infrared imaging↗

Physics-guided logistic classification for tool life modeling and process parameter optimization in machining

This paper describes a physics-guided logistic classification method for tool life modeling and process parameter optimization in machining. Tool life is modeled using a classification method since the exact tool life cannot be measured in a typical production environment where tool wear can only be directly measured when the tool is replaced. Here, in this study, laboratory tool wear experiments are used to simulate tool wear data normally collected during part production. Two states are defined: tool not worn (class 0) and tool worn (class 1). The non-linear reduction in tool life with cutting speed is modeled by applying a logarithmic transformation to the inputs for the logistic classification model. A method for interpretability of the logistic model coefficients is provided by comparison with the empirical Taylor tool life model. The method is validated using tool wear experiments for milling. Results show that the physics-guided logistic classification method can predict tool life using limited datasets. A method for pre-process optimization of machining parameters using a probabilistic machining cost model is presented. The proposed method offers a robust and practical approach to tool life modeling and process parameter optimization in a production environment.

Machine learning↗