Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIOACTIVE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

MuSIC@Indiana: An effective tool for accurate measurement of fusion with low-intensity radioactive beams

The design, construction, and characterization of the Multi-Sampling Ionization Chamber, MuSIC@Indiana, are described. This detector provides efficient and accurate measurement of the fusion cross-section at near-barrier energies. The response of the detector to low-intensity beams of 17,18 O, 19 F, 23 Na, 24,26 Mg, 27 Al, and 28 Si at E lab 50–60MeV was examined. MuSIC@Indiana was commissioned by measuring the 18 O+ 12 C fusion excitation function for 11 < E cm < 20 MeV using CH 4 gas. Here, a simple, effective analysis cleanly distinguishes proton capture and two-body scattering events from fusion on carbon. With MuSIC@Indiana, measurement of 15 points on the excitation function for a single incident beam energy is achieved. The resulting excitation function is shown to be in good agreement with literature data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-MeV ultra-compact linac for radioactive isotope sources replacement, non-destructive testing, security and medical applications

RadiaBeam Technologies, LLC has developed an inexpensive, hand-portable 180 keV electron accelerator to replace 57 Co radionuclide sources in Cascade Header Enrichment Monitor detectors. We used two innovative technologies in our design: a Ku-band (1 cm wavelength) magnetron, and a split accelerating structure design to reduce manufacturing costs. In this paper, we will discuss the accelerator, including X-ray convertor and accelerating structure design. The results of RF measurements of a Ku-band split structure prototype will also be reviewed. Other applications of Ku-band linacs include compact backscatter and transmission X-ray security inspection systems, as well as computed tomography (CT) systems for luggage and parcel screening. The main requirement for luggage inspection systems is that the X-ray source must be extremely compact. Further, the required energies should cover the range from 180 keV to 1 MeV. In this paper, we will discuss the linac’s energy scalability and other modifications that will enable our technology to address these applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First on-line detection of radioactive fission isotopes produced by laser-accelerated protons

Abstract The on-going developments in laser acceleration of protons and light ions, as well as the production of strong bursts of neutrons and multi- $$\hbox {MeV}$$ MeV photons by secondary processes now provide a basis for novel high-flux nuclear physics experiments. While the maximum energy of protons resulting from Target Normal Sheath Acceleration is presently still limited to around $$100 \, \hbox {MeV}$$ 100 MeV , the generated proton peak flux within the short laser-accelerated bunches can already today exceed the values achievable at the most advanced conventional accelerators by orders of magnitude. This paper consists of two parts covering the scientific motivation and relevance of such experiments and a first proof-of-principle demonstration. In the presented experiment pulses of $$200 \, \hbox {J}$$ 200 J at $$\approx \, 500 \, \hbox {fs}$$ ≈ 500 fs duration from the PHELIX laser produced more than $$10^{12}$$ 10 12 protons with energies above $$15 \, \hbox {MeV}$$ 15 MeV in a bunch of sub-nanosecond duration. They were used to induce fission in foil targets made of natural uranium. To make use of the nonpareil flux, these targets have to be very close to the laser acceleration source, since the particle density within the bunch is strongly affected by Coulomb explosion and the velocity differences between ions of different energy. The main challenge for nuclear detection with high-purity germanium detectors is given by the strong electromagnetic pulse caused by the laser-matter interaction close to the laser acceleration source. This was mitigated by utilizing fast transport of the fission products by a gas flow to a carbon filter, where the $$\upgamma$$ γ -rays were registered. The identified nuclides include those that have half-lives down to $$39 \, \hbox {s}$$ 39 s . These results demonstrate the capability to produce, extract, and detect short-lived reaction products under the demanding experimental condition imposed by the high-power laser interaction. The approach promotes research towards relevant nuclear astrophysical studies at conditions currently only accessible at nuclear high energy density laser facilities.

07 ISOTOPE AND RADIATION SOURCES↗

Fluorescent, phosphorescent, magnetic resonance contrast and radioactive tracer labelling of extracellular vesicles

This review focusses on the significance of fluorescent, phosphorescent labelling and tracking of extracellular vesicles (EVs) for unravelling their biology, pathophysiology, and potential diagnostic and therapeutic uses. Various labeling strategies, such as lipid membrane, surface protein, luminal, nucleic acid, radionuclide, quantum dot labels, and metal complex-based stains, are evaluated for visualizing and characterizing EVs. Direct labelling with fluorescent lipophilic dyes is simple but generally lacks specificity, while surface protein labelling offers selectivity but may affect EV-cell interactions. Luminal and nucleic acid labelling strategies have their own advantages and challenges. Here, each labelling approach has strengths and weaknesses, which require a suitable probe and technique based on research goals, but new tetranuclear polypyridylruthenium(II) complexes as phosphorescent probes have strong phosphorescence, selective staining, and stability. Future research should prioritize the design of novel fluorescent probes and labelling platforms that can significantly enhance the efficiency, accuracy, and specificity of EV labeling, while preserving their composition and functionality. It is crucial to reduce false positive signals and explore the potential of multimodal imaging techniques to gain comprehensive insights into EVs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A technique for studying (n,p) reactions of astrophysical interest using radioactive beams with SECAR

The formation of nuclei in slightly proton-rich regions of the neutrino-driven wind of core-collapse supernovae could be attributed to the neutrino-p process (νp-process). As it proceeds via a sequence of (p,γ) and (n,p) reactions, it may produce elements in the range of Ni and Sn, considering adequate conditions. Recent studies identify a number of decisive (n,p) reactions that control the efficiency of the νp-process. The study of one such (n,p) reaction via the measurement of the reverse (p,n) in inverse kinematics was performed with SECAR at NSCL/FRIB. Proton-induced reaction measurements, especially at the mass region of interest, are notably difficult since the recoils have nearly identical masses as the unreacted projectiles. Such measurements are feasible with the adequate separation level achieved with SECAR, and the in-coincidence neutron detection. Adjustments of the SECAR system for the first (p,n) reaction measurement included the development of new ion beam optics, and the installation of the neutron detection system. The aforementioned developments along with a discussion on the preliminary results of the p(58Fe,n)58Co reaction measurement are presented.

Tsintari, P↗