Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION INTENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

SU-E-T-572: Normal Lung Tissue Sparing in Radiation Therapy for Locally Advanced Non-Small Cell Lung Cancer

Purpose: To compare normal lung-sparing capabilities of three advanced radiation therapy techniques for locally advanced non-small cell lung cancer (LA-NSCLC). Methods: Four-dimensional computed tomography (4DCT) was performed in 10 patients with stage IIIb LA-NSCLC. The internal target volume (ITV); planning target volume (PTV); and organs at risks (OARs) such as spinal cord, total normal lung, heart, and esophagus were delineated for each CT data set. Intensity-modulated radiation therapy (IMRT), Tomohelical-IMRT (TH-IMRT), and TomoDirect-IMRT (TD-IMRT) plans were generated (total prescribed dose, 66 Gy in 33 fractions to the PTV) for each patient. To reduce the normal lung dose, complete and directional block function was applied outside the normal lung far from the target for both TH-IMRT and TD-IMRT, while pseudo- OAR was set in the same region for IMRT. Dosimetric characteristics of the three plans were compared in terms of target coverage, the sparing capability for the OAR, and the normal tissue complication probability (NTCP). Beam delivery efficiency was also compared. Results: TH-IMRT and TD-IMRT provided better target coverage than IMRT plans. Lung volume receiving ≥–30 Gy, mean dose, and NTCP were significant with TH-IMRT than with IMRT (p=0.006), and volume receiving ≥20–30 Gy was lower in TD-IMRT than in IMRT (p<0.05). Compared with IMRT, TH-IMRT had better sparing effect on the spinal cord (Dmax, NTCP) and heart (V45) (p<0.05). NTCP for the spinal cord, V45 and V60 for the heart, and Dmax for the esophagus were significantly lower in TD-IMRT than in IMRT. The monitor units per fraction were clearly smaller for IMRT than for TH-IMRT and TD-IMRT (p=0.006). Conclusion: In LA-NSCLC, TH-IMRT gave superior PTV coverage and OAR sparing compared to IMRT. TH-IMRT provided better control of the lung volume receiving ≥5–30 Gy. The delivery time and monitor units were lower in TD-IMRT than in TH-IMRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

FHR Process Instruments

Fluoride salt-cooled High temperature Reactors (FHRs) are entering into early phase engineering development. Initial candidate technologies have been identified to measure all of the required process variables. The purpose of this paper is to describe the proposed measurement techniques in sufficient detail to enable assessment of the proposed instrumentation suite and to support development of the component technologies. This paper builds upon the instrumentation chapter of the recently published FHR technology development roadmap. Locating instruments outside of the intense core radiation and high-temperature fluoride salt environment significantly decreases their environmental tolerance requirements. Under operating conditions, FHR primary coolant salt is a transparent, low-vapor-pressure liquid. Consequently, FHRs can employ standoff optical measurements from above the salt pool to assess in-vessel conditions. For example, the core outlet temperature can be measured by observing the fuel s blackbody emission. Similarly, the intensity of the core s Cerenkov glow indicates the fission power level. Short-lived activation of the primary coolant provides another means for standoff measurements of process variables. The primary coolant flow and neutron flux can be measured using gamma spectroscopy along the primary coolant piping. FHR operation entails a number of process measurements. Reactor thermal power and core reactivity are the most significant variables for process control. Thermal power can be determined by measuring the primary coolant mass flow rate and temperature rise across the core. The leading candidate technologies for primary coolant temperature measurement are Au-Pt thermocouples and Johnson noise thermometry. Clamp-on ultrasonic flow measurement, that includes high-temperature tolerant standoffs, is a potential coolant flow measurement technique. Also, the salt redox condition will be monitored as an indicator of its corrosiveness. Both electrochemical techniques and optical spectroscopy are candidate fluoride salt redox measurement methods. Coolant level measurement can be performed using radar-level gauges located in standpipes above the reactor vessel. While substantial technical development remains for most of the instruments, industrially compatible instruments based upon proven technology can be reasonably extrapolated from the current state of the art.

FHR↗

Decision Regret in Men Undergoing Dose-Escalated Radiation Therapy for Prostate Cancer

Purpose: Decision regret (DR) is a negative emotion associated with medical treatment decisions, and it is an important patient-centered outcome after therapy for localized prostate cancer. DR has been found to occur in up to 53% of patients treated for localized prostate cancer, and it may vary depending on treatment modality. DR after modern dose-escalated radiation therapy (DE-RT) has not been investigated previously, to our knowledge. Our primary aim was to evaluate DR in a cohort of patients treated with DE-RT. Methods and Materials: We surveyed 257 consecutive patients with localized prostate cancer who had previously received DE-RT, by means of a validated questionnaire. Results: There were 220 responses (85.6% response rate). Image-guided intensity modulated radiation therapy was given in 85.0% of patients and 3-dimensional conformal radiation therapy in 15.0%. Doses received included 73.8 Gy (34.5% patients), 74 Gy (53.6%), and 76 Gy (10.9%). Neoadjuvant androgen deprivation (AD) was given in 51.8% of patients and both neoadjuvant and adjuvant AD in 34.5%. The median follow-up time was 23 months (range, 12-67 months). In all, 3.8% of patients expressed DR for their choice of treatment. When asked whether they would choose DE-RT or AD again, only 0.5% probably or definitely would not choose DE-RT again, compared with 8.4% for AD (P<.01). Conclusion: Few patients treated with modern DE-RT express DR, with regret appearing to be lower than in previously published reports of patients treated with radical prostatectomy or older radiation therapy techniques. Patients experienced more regret with the AD component of treatment than with the radiation therapy component, with implications for informed consent. Further research should investigate regret associated with individual components of modern therapy, including AD, radiation therapy and surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Variations in the Contouring of Organs at Risk: Test Case From a Patient With Oropharyngeal Cancer

Purpose: Anatomy contouring is critical in radiation therapy. Inaccuracy and variation in defining critical volumes will affect everything downstream: treatment planning, dose-volume histogram analysis, and contour-based visual guidance used in image-guided radiation therapy. This study quantified: (1) variation in the contouring of organs at risk (OAR) in a clinical test case and (2) corresponding effects on dosimetric metrics of highly conformal plans. Methods and Materials: A common CT data set with predefined targets from a patient with oropharyngeal cancer was provided to a population of clinics, which were asked to (1) contour OARs and (2) design an intensity-modulated radiation therapy plan. Thirty-two acceptable plans were submitted as DICOM RT data sets, each generated by a different clinical team. Using those data sets, we quantified: (1) the OAR contouring variation and (2) the impact this variation has on dosimetric metrics. New technologies were employed, including a software tool to quantify three-dimensional structure comparisons. Results: There was significant interclinician variation in OAR contouring. The degree of variation is organ-dependent. We found substantial dose differences resulting strictly from contouring variation (differences ranging from -289% to 56% for mean OAR dose; -22% to 35% for maximum dose). However, there appears to be a threshold in the OAR comparison metric beyond which the dose differences stabilize. Conclusions: The effects of interclinician variation in contouring organs-at-risk in the head and neck can be large and are organ-specific. Physicians need to be aware of the effect that variation in OAR contouring can play on the final treatment plan and not restrict their focus only to the target volumes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-605: Performance Evaluation of MLC Leaf-Sequencing Algorithms in Head-And-Neck IMRT

Purpose: To investigate the efficiency of three multileaf collimator (MLC) leaf-sequencing algorithms proposed by Galvin et al, Chen et al and Siochi et al using external beam treatment plans for head-and-neck intensity modulated radiation therapy (IMRT). Methods: IMRT plans for head-and-neck were created using the CORVUS treatment planning system. The plans were optimized and the fluence maps for all photon beams determined. Three different MLC leaf-sequencing algorithms based on Galvin et al, Chen et al and Siochi et al were used to calculate the final photon segmental fields and their monitor units in delivery. For comparison purpose, the maximum intensity of fluence map was kept constant in different plans. The number of beam segments and total number of monitor units were calculated for the three algorithms. Results: From results of number of beam segments and total number of monitor units, we found that algorithm of Galvin et al had the largest number of monitor unit which was about 70% larger than the other two algorithms. Moreover, both algorithms of Galvin et al and Siochi et al have relatively lower number of beam segment compared to Chen et al. Although values of number of beam segment and total number of monitor unit calculated by different algorithms varied with the head-and-neck plans, it can be seen that algorithms of Galvin et al and Siochi et al performed well with a lower number of beam segment, though algorithm of Galvin et al had a larger total number of monitor units than Siochi et al. Conclusion: Although performance of the leaf-sequencing algorithm varied with different IMRT plans having different fluence maps, an evaluation is possible based on the calculated number of beam segment and monitor unit. In this study, algorithm by Siochi et al was found to be more efficient in the head-and-neck IMRT. The Project Sponsored by the Fundamental Research Funds for the Central Universities (J2014HGXJ0094) and the Scientific Research Foundation for the Returned Overseas Chinese Scholars, State Education Ministry.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Extraordinary March 2022 East Antarctica “Heat” Wave. Part II: Impacts on the Antarctic Ice Sheet

Abstract Between 15 and 19 March 2022, East Antarctica experienced an exceptional heat wave with widespread 30°–40°C temperature anomalies across the ice sheet. In Part I, we assessed the meteorological drivers that generated an intense atmospheric river (AR) that caused these record-shattering temperature anomalies. Here, we continue our large collaborative study by analyzing the widespread and diverse impacts driven by the AR landfall. These impacts included widespread rain and surface melt that was recorded along coastal areas, but this was outweighed by widespread high snowfall accumulations resulting in a largely positive surface mass balance contribution to the East Antarctic region. An analysis of the surface energy budget indicated that widespread downward longwave radiation anomalies caused by large cloud-liquid water contents along with some scattered solar radiation produced intense surface warming. Isotope measurements of the moisture were highly elevated, likely imprinting a strong signal for past climate reconstructions. The AR event attenuated cosmic ray measurements at Concordia, something previously never observed. Last, an extratropical cyclone west of the AR landfall likely triggered the final collapse of the critically unstable Conger Ice Shelf while further reducing an already record low sea ice extent. Significance Statement Using our diverse collective expertise, we explored the impacts from the March 2022 heat wave and atmospheric river across East Antarctica. One key takeaway is that the Antarctic cryosphere is highly sensitive to meteorological extremes originating from the midlatitudes and subtropics. Despite the large positive temperature anomalies driven from strong downward longwave radiation, this event led to huge amounts of snowfall across the Antarctic interior desert. The isotopes in this snow of warm airmass origin will likely be detectable in future ice cores and potentially distort past climate reconstructions. Even measurements of space activity were affected. Also, the swells generated from this storm helped to trigger the final collapse of an already critically unstable Conger Ice Shelf while further degrading sea ice coverage.

Wille, Jonathan D.↗

Mechanical properties of Skylab thermal shield materials after prolonged ultraviolet irradiation

In response to an emergency request, the mechanical properties of two complex laminate materials, used as thermal shields on the Skylab spacecraft, were investigated. Concern over the prolonged use of these materials in the space environment prompted this investigation. Shields made of both of these materials, popularly called the parasol and the sail types, were taken to the Skylab spacecraft by the original Skylab astronauts. Both were used to restore thermal control after the original control surfaces were damaged during launch. During the tests the tensile properties were measured at anticipated service temperature and after prolonged exposure to increasing degrees of ultraviolet radiation at intensities approaching two solar constants. Some samples received exposures equivalent to 2,350 hours. The performance and degradation of the two materials are presented in terms of orientation, vacuum, and degree of irradiation. In general, the 75-micron (3-mil) parasol laminate showed a decrease in tensile properties as a function of exposure time, while the 200-micron (8-mil) sail laminate was little affected by exposure to the ultraviolet radiation.

Haehner, C. L.↗

On charged particle equilibrium violation in external photon fields

Purpose: In a recent paper by Bouchard et al.[Med. Phys. 36(10), 4654-4663 (2009)], a theoretical model of quality correction factors for idealistic so-called plan-class specific reference (PCSR) fields was proposed. The reasoning was founded on the definition of PCSR fields made earlier by Alfonso et al.[Med. Phys. 35(11), 5179-5186 (2008)], requiring the beam to achieve charged particle equilibrium (CPE), in a time-averaged sense, in the reference medium. The relation obtained by Bouchard et al. was derived using Fano's theorem (1954) which states that if CPE is established in a given medium, the dose is independent of point-to-point density variations. A potential misconception on the achievability of the condition required by Fano (1954) might be responsible for false practical conclusions, both in the definition of PCSR fields as well as the theoretical model of quality correction factor. Methods: In this paper, the practical achievability of CPE in external beams is treated in detail. The fact that this condition is not achievable in single or composite deliveries is illustrated by an intuitive method and is also formally demonstrated. Conclusions: Fano's theorem is not applicable in external beam radiation dosimetry without (virtually) removing attenuation effects, and therefore, the relation conditionally defined by Bouchard et al. (2009) cannot be valid in practice. A definition of PCSR fields in the recent formalism for nonstandard beams proposed by Alfonso et al. (2008) should be modified, revising the criterion of CPE condition. The authors propose reconsidering the terminology used to describe standard and nonstandard beams. The authors argue that quality correction factors of intensity modulated radiation therapy PCSR fields (i.e., k{sub Q{sub p{sub c{sub s{sub r,Q}{sup f{sub p}{sub c}{sub s}{sub r},f{sub r}{sub e}{sub f}}}}}}) could be unity under ideal conditions, but it is concluded that further investigation is necessary to confirm that hypothesis.

61 RADIATION PROTECTION AND DOSIMETRY↗

Longitudinal Investigation of Adaptive Functioning Following Conformal Irradiation for Pediatric Craniopharyngioma and Low-Grade Glioma

Purpose: Children treated for brain tumors with conformal radiation therapy experience preserved cognitive outcomes. Early evidence suggests that adaptive functions or independent-living skills may be spared. This longitudinal investigation prospectively examined intellectual and adaptive functioning during the first 5 years following irradiation for childhood craniopharyngioma and low-grade glioma (LGG). The effect of visual impairment on adaptive outcomes was investigated. Methods and Materials: Children with craniopharyngioma (n=62) and LGG (n=77) were treated using conformal or intensity modulated radiation therapy. The median age was 8.05 years (3.21-17.64 years) and 8.09 years (2.20-19.27 years), respectively. Serial cognitive evaluations including measures of intelligence quotient (IQ) and the Vineland Adaptive Behavior Scales (VABS) were conducted at preirradiation baseline, 6 months after treatment, and annually through 5 years. Five hundred eighty-eight evaluations were completed during the follow-up period. Results: Baseline assessment revealed no deficits in IQ and VABS indices for children with craniopharyngioma, with significant (P<.05) longitudinal decline in VABS Communication and Socialization indices. Clinical factors associated with more rapid decline included females and preirradiation chemotherapy (interferon). The only change in VABS Daily Living Skills correlated with IQ change (r=0.34; P=.01) in children with craniopharyngioma. Children with LGG performed below population norms (P<.05) at baseline on VABS Communication, Daily Living Indices, and the Adaptive Behavior Composite, with significant (P<.05) longitudinal decline limited to VABS Communication. Older age at irradiation was a protective factor against longitudinal decline. Severe visual impairment did not independently correlate with poorer adaptive outcomes for either tumor group. Conclusions: There was relative sparing of postirradiation functional outcomes over time in this sample. Baseline differences in functional abilities before the initiation of irradiation suggested that other factors influence functional outcomes above and beyond the effects of irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

National Cancer Data Base Analysis of Radiation Therapy Consolidation Modality for Cervical Cancer: The Impact of New Technological Advancements

Purpose: To utilize the National Cancer Data Base to evaluate trends in brachytherapy and alternative radiation therapy utilization in the treatment of cervical cancer, to identify associations with outcomes between the various radiation therapy modalities. Methods and Materials: Patients with International Federation of Gynecology and Obstetrics stage IIB-IVA cervical cancer in the National Cancer Data Base who received treatment from January 2004 to December 2011 were analyzed. Overall survival was estimated by the Kaplan-Meier method. Univariate and multivariable analyses were performed to identify factors associated with type of boost radiation modality used and its impact on survival. Results: A total of 7654 patients had information regarding boost modality. A predominant proportion of patients were Caucasian (76.2%), had stage IIIB (48.9%) disease with squamous (82.0%) histology, were treated at academic/research centers (47.7%) in the South (34.8%), and lived 0 to 5 miles (27.9%) from the treating facility. A majority received brachytherapy (90.3%). From 2004 to 2011, brachytherapy use decreased from 96.7% to 86.1%, whereas intensity modulated radiation therapy (IMRT) and stereotactic body radiation therapy (SBRT) use increased from 3.3% to 13.9% in the same period (P<.01). Factors associated with decreased brachytherapy utilization included older age, stage IVA disease, smaller tumor size, later year of diagnosis, lower-volume treatment centers, and facility type. After controlling for significant factors from survival analyses, IMRT or SBRT boost resulted in inferior overall survival (hazard ratio, 1.86; 95% confidence interval, 1.35-2.55; P<.01) as compared with brachytherapy. In fact, the survival detriment associated with IMRT or SBRT boost was stronger than that associated with excluding chemotherapy (hazard ratio, 1.61′ 95% confidence interval, 1.27-2.04′ P<.01). Conclusions: Consolidation brachytherapy is a critical treatment component for locally advanced cervical cancer; however, there has been declining utilization of brachytherapy. Increased use of IMRT and SBRT boost coupled with increased mortality risk should raise concerns about utilizing these approaches over brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Silicon Carbide Solar Cells Investigated

The semiconductor silicon carbide (SiC) has long been known for its outstanding resistance to harsh environments (e.g., thermal stability, radiation resistance, and dielectric strength). However, the ability to produce device-quality material is severely limited by the inherent crystalline defects associated with this material and their associated electronic effects. Much progress has been made recently in the understanding and control of these defects and in the improved processing of this material. Because of this work, it may be possible to produce SiC-based solar cells for environments with high temperatures, light intensities, and radiation, such as those experienced by solar probes. Electronics and sensors based on SiC can operate in hostile environments where conventional silicon-based electronics (limited to 350 C) cannot function. Development of this material will enable large performance enhancements and size reductions for a wide variety of systems--such as high-frequency devices, high-power devices, microwave switching devices, and high-temperature electronics. These applications would supply more energy-efficient public electric power distribution and electric vehicles, more powerful microwave electronics for radar and communications, and better sensors and controls for cleaner-burning, more fuel-efficient jet aircraft and automobile engines. The 6H-SiC polytype is a promising wide-bandgap (Eg = 3.0 eV) semiconductor for photovoltaic applications in harsh solar environments that involve high-temperature and high-radiation conditions. The advantages of this material for this application lie in its extremely large breakdown field strength, high thermal conductivity, good electron saturation drift velocity, and stable electrical performance at temperatures as high as 600 C. This behavior makes it an attractive photovoltaic solar cell material for devices that can operate within three solar radii of the Sun.

Bailey, Sheila G.↗

Intensity-Modulated Radiotherapy for Head-and-Neck Cancer in the Community Setting

Purpose: To review outcomes with intensity-modulated radiation therapy (IMRT) in the community setting for the treatment of nasopharyngeal and oropharyngeal cancer. Methods and Materials: Between April 2003 and April 2007, 69 patients with histologically confirmed cancer of the nasopharynx and oropharynx underwent IMRT in our practice. The primary sites included nasopharynx (11), base of tongue (18), and tonsil (40). The disease stage distribution was as follows: 2 Stage I, 11 Stage II, 16 Stage III, and 40 Stage IV. All were treated with a simultaneous integrated boost IMRT technique. The median prescribed doses were 70 Gy to the planning target volume, 59.4 Gy to the high-risk subclinical volume, and 54 Gy to the low-risk subclinical volume. Forty-five patients (65%) received concurrent chemotherapy. Toxicity was graded according to the Radiation Therapy Oncology Group toxicity criteria. Progression-free and overall survival rates were estimated with the Kaplan-Meier product-limit method. Results: Median duration of follow-up was 18 months. The estimated 2-year local control, regional control, distant control, and overall survival rates were 98%, 100%, 98%, and 90%, respectively. The most common acute toxicities were dermatitis (32 Grade 1, 32 Grade 2, 5 Grade 3), mucositis (8 Grade 1, 33 Grade 2, 28 Grade 3), and xerostomia (0 Grade 1, 29 Grade 2, 40 Grade 3). Conclusions: Intensity-modulated radiotherapy in the community setting can be accomplished safely and effectively. Systematic internal review systems are recommended for quality control until sufficient experience develops.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric evaluation of a dedicated stereotactic linear accelerator using measurement and Monte Carlo simulation

Dosimetric parameters of a dedicated stereotactic linear accelerator have been investigated using measurements and Monte Carlo simulations. This linac has a unique built in multileaf collimation (MLC) system with the maximum opening of 16x21 cm{sup 2} and 4 mm leaf width at the isocenter and has successfully been modeled for the first time using the Monte Carlo simulation. The high resolution MLC, combined with its relatively large maximum field size, opens up a new opportunity for expanding stereotactic radiation treatment techniques from traditionally treating smaller targets to larger ones for both cranial and extracranial lesions. Dosimetric parameters of this linac such as accuracy of leaf positioning and field shaping, leakage and transmission, percentage depth doses, off-axes dose profiles, and dose penumbras were measured and calculated for different field sizes, depths, and source to surface distances. In addition, the ability of the linac in accurate dose delivery of several treatment plans, including intensity modulated radiation therapy (IMRT), performed on phantom and patients was determined. Ionization chamber, photon diode detector, films, several solid water phantoms, and a water tank were used for the measurements. The MLC leaf positioning to any particular point in the maximum aperture was accurate with a standard deviation of 0.29 mm. Maximum and average leakages were 1.7% and 1.1% for the reference field of 10.4x9.6 cm{sup 2}. Measured penumbra widths (80%-20%) for this field at source axis distance (SAD) of 100 cm at a depth of 1.5 cm (d{sub max}) were 3.2 and 4 mm for the leaf-sides and leaf-ends, respectively. The corresponding results at 10 cm depth and SAD=100 cm were 5.4 and 6.3 mm. Monte Carlo results generally agreed with the measurements to within 1% and or 1 mm, with respective uncertainties of 0.5% and 0.2 mm. The linac accuracy in delivering non-IMRT treatment plans was better than 1%. Ionization chamber dosimetry results for a phantom IMRT plan in the high dose and low dose regions were -0.5% and +3.6%, respectively. Dosimetry results at isocenter for three patients' IMRT plans were measured to be within 3% of their corresponding treatment plans. Film dosimetry was also used to compare dose distributions of IMRT treatment plans and delivered cumulative doses at different cross sectional planes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation-induced second cancers: the impact of 3D-CRT and IMRT

Information concerning radiation-induced malignancies comes from the A-bomb survivors and from medically exposed individuals, including second cancers in radiation therapy patients. The A-bomb survivors show an excess incidence of carcinomas in tissues such as the gastrointestinal tract, breast, thyroid, and bladder, which is linear with dose up to about 2.5 Sv. There is great uncertainty concerning the dose-response relationship for radiation-induced carcinogenesis at higher doses. Some animal and human data suggest a decrease at higher doses, usually attributed to cell killing; other data suggest a plateau in dose. Radiotherapy patients also show an excess incidence of carcinomas, often in sites remote from the treatment fields; in addition there is an excess incidence of sarcomas in the heavily irradiated in-field tissues. The transition from conventional radiotherapy to three-dimensional conformal radiation therapy (3D-CRT) involves a reduction in the volume of normal tissues receiving a high dose, with an increase in dose to the target volume that includes the tumor and a limited amount of normal tissue. One might expect a decrease in the number of sarcomas induced and also (less certain) a small decrease in the number of carcinomas. All around, a good thing. By contrast, the move from 3D-CRT to intensity-modulated radiation therapy (IMRT) involves more fields, and the dose-volume histograms show that, as a consequence, a larger volume of normal tissue is exposed to lower doses. In addition, the number of monitor units is increased by a factor of 2 to 3, increasing the total body exposure, due to leakage radiation. Both factors will tend to increase the risk of second cancers. Altogether, IMRT is likely to almost double the incidence of second malignancies compared with conventional radiotherapy from about 1% to 1.75% for patients surviving 10 years. The numbers may be larger for longer survival (or for younger patients), but the ratio should remain the same.

Review, Tutorial↗

Outcomes and Prognostic Variables in Adenoid Cystic Carcinoma of the Head and Neck: A Recent Experience

Purpose: To analyze the recent experience of patients with adenoid cystic carcinoma treated with radiation therapy at Memorial Sloan-Kettering Cancer Center. Methods and Materials: From 1990 to 2004, a total of 59 patients with a diagnosis of primary adenoid cystic carcinoma of the head and neck received radiation therapy at our institution. The subsite distribution was oral cavity, 28% (n = 17); paranasal sinuses, 22% (n = 13); parotid, 14% (n = 8); submandibular, 14% (n = 8); oropharynx, 10% (n = 6); sublingual, 3% (n = 2); nasopharynx, 3% (n = 2); and other, 5% (n = 3). T Stage distribution was T1, 34% (n = 20); T2, 19% (n = 11); T3, 14% (n = 8); and T4, 34% (n = 20). Twenty-nine percent of patients (n = 17) were treated with intensity-modulated radiation therapy; 25% (n =15), with three-dimensional conformal therapy, and the remainder, with conventional techniques. Ninety percent (n = 53) of patients received treatment including the base of skull. Results: Median follow-up for surviving patients was 5.9 years. Five-year and 10-year rates of local control and distant metastases-free survival were 91%/81% and 81%/49%, respectively. Five-year and 10-year rates of disease-free and overall survival were 76%/40% and 87%/65%, respectively. On univariate analysis, stage T4 (p = 0.004) and gross/clinical nerve involvement (p = 0.002) were associated with decreased progression free survival, whereas stage T4 and lymph node involvement were associated with decreased overall survival (p = 0.046 and p < 0.001, respectively). Conclusions: Radiation therapy in combination with surgery produces excellent rates of local control, although distant metastases account for a high proportion of failures. Routine treatment to the base of skull reduces the significance of histologic perineural invasion, but major nerve involvement remains an adverse prognostic factor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PARETO: A novel evolutionary optimization approach to multiobjective IMRT planning

Purpose: In radiation therapy treatment planning, the clinical objectives of uniform high dose to the planning target volume (PTV) and low dose to the organs-at-risk (OARs) are invariably in conflict, often requiring compromises to be made between them when selecting the best treatment plan for a particular patient. In this work, the authors introduce Pareto-Aware Radiotherapy Evolutionary Treatment Optimization (pareto), a multiobjective optimization tool to solve for beam angles and fluence patterns in intensity-modulated radiation therapy (IMRT) treatment planning. Methods: pareto is built around a powerful multiobjective genetic algorithm (GA), which allows us to treat the problem of IMRT treatment plan optimization as a combined monolithic problem, where all beam fluence and angle parameters are treated equally during the optimization. We have employed a simple parameterized beam fluence representation with a realistic dose calculation approach, incorporating patient scatter effects, to demonstrate feasibility of the proposed approach on two phantoms. The first phantom is a simple cylindrical phantom containing a target surrounded by three OARs, while the second phantom is more complex and represents a paraspinal patient. Results: pareto results in a large database of Pareto nondominated solutions that represent the necessary trade-offs between objectives. The solution quality was examined for several PTV and OAR fitness functions. The combination of a conformity-based PTV fitness function and a dose-volume histogram (DVH) or equivalent uniform dose (EUD) -based fitness function for the OAR produced relatively uniform and conformal PTV doses, with well-spaced beams. A penalty function added to the fitness functions eliminates hotspots. Comparison of resulting DVHs to those from treatment plans developed with a single-objective fluence optimizer (from a commercial treatment planning system) showed good correlation. Results also indicated that pareto shows promise in optimizing the number of beams. Conclusions: This initial evaluation of the evolutionary optimization software tool pareto for IMRT treatment planning demonstrates feasibility and provides motivation for continued development. Advantages of this approach over current commercial methods for treatment planning are many, including: (1) fully automated optimization that avoids human controlled iterative optimization and potentially improves overall process efficiency, (2) formulation of the problem as a true multiobjective one, which provides an optimized set of Pareto nondominated solutions refined over hundreds of generations and compiled from thousands of parameter sets explored during the run, and (3) rapid exploration of the final nondominated set accomplished by a graphical interface used to select the best treatment option for the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Trends in the Quality of Treatment for Patients With Intact Cervical Cancer in the United States, 1999 Through 2011

Purpose: High-quality treatment for intact cervical cancer requires external radiation therapy, brachytherapy, and chemotherapy, carefully sequenced and completed without delays. We sought to determine how frequently current treatment meets quality benchmarks and whether new technologies have influenced patterns of care. Methods and Materials: By searching diagnosis and procedure claims in MarketScan, an employment-based health care claims database, we identified 1508 patients with nonmetastatic, intact cervical cancer treated from 1999 to 2011, who were <65 years of age and received >10 fractions of radiation. Treatments received were identified using procedure codes and compared with 3 quality benchmarks: receipt of brachytherapy, receipt of chemotherapy, and radiation treatment duration not exceeding 63 days. The Cochran-Armitage test was used to evaluate temporal trends. Results: Seventy-eight percent of patients (n=1182) received brachytherapy, with brachytherapy receipt stable over time (Cochran-Armitage P{sub trend}=.15). Among patients who received brachytherapy, 66% had high–dose rate and 34% had low–dose rate treatment, although use of high–dose rate brachytherapy steadily increased to 75% by 2011 (P{sub trend}<.001). Eighteen percent of patients (n=278) received intensity modulated radiation therapy (IMRT), and IMRT receipt increased to 37% by 2011 (P{sub trend}<.001). Only 2.5% of patients (n=38) received IMRT in the setting of brachytherapy omission. Overall, 79% of patients (n=1185) received chemotherapy, and chemotherapy receipt increased to 84% by 2011 (P{sub trend}<.001). Median radiation treatment duration was 56 days (interquartile range, 47-65 days); however, duration exceeded 63 days in 36% of patients (n=543). Although 98% of patients received at least 1 benchmark treatment, only 44% received treatment that met all 3 benchmarks. With more stringent indicators (brachytherapy, ≥4 chemotherapy cycles, and duration not exceeding 56 days), only 25% of patients received treatment that met all benchmarks. Conclusion: In this cohort, most cervical cancer patients received treatment that did not comply with all 3 benchmarks for quality treatment. In contrast to increasing receipt of newer radiation technologies, there was little improvement in receipt of essential treatment benchmarks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-magnification Faraday rotation imaging and analysis of X-pinch implosion dynamics

An X-pinch load driven by an intense current pulse (>100 kA in ~100 ns) can result in the formation of a small radius, runaway compressional micro-pinch. A micro-pinch is characterized by a hot (>1 keV), current-driven (>100 kA), high-density plasma column (near solid density) with a small neck diameter (1–10 µm), a short axial extent (<1 mm), and a short duration (≲1 ns). With material pressures often well into the multi-Mbar regime, a micro-pinch plasma often radiates an intense, sub-ns burst of sub-keV to multi-keV x rays. A low-density coronal plasma immediately surrounding the dense plasma neck could potentially shunt current away from the neck and thus reduce the magnetic drive pressure applied to the neck. Here, to study the current distribution in the coronal plasma, a Faraday rotation imaging diagnostic (1064 nm) capable of producing simultaneous high-magnification polarimetric and interferometric images has been developed for the MAIZE facility at the University of Michigan. Designed with a variable magnification (1–10×), this diagnostic achieves a spatial resolution of ~35 µm, which is useful for resolving the ~100-μm-scale coronal plasma immediately surrounding the dense core. This system has now been used on a reduced-output MAIZE (100–200 kA, 150 ns) to assess the radial distribution of drive current immediately surrounding the dense micro-pinch neck. The total current enclosed was found to increase as a function of radius, r, from a value of ≈ 50 ± 25 kA at r ≈ 140 µm (at the edge of the dense neck) to a maximal value of ≈150 ± 75 kA for r ≥ 225 µm. This corresponds to a peak magnetic drive pressure of ≈75 ± 50 kbar at r ≈ 225 µm. The limitations of these measurements are discussed in the paper.

47 OTHER INSTRUMENTATION↗