Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Protection & Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Monticello Mill Tailings Site, Operable Unit lll, Annual Groundwater Report, May 2015 Through April 2016

This report provides the annual analysis of water quality restoration progress, cumulative through April 2016, for Operable Unit (OU) III, surface water and groundwater, of the U.S. Department of Energy (DOE) Office of Legacy Management (LM) Monticello Mill Tailings Site (MMTS). The MMTS is a Comprehensive Environmental Response, Compensation, and Liability Act National Priorities List site located in and near the city of Monticello, San Juan County, Utah. MMTS comprises the 110-acre site of a former uranium- and vanadium-ore-processing mill (mill site) and 1700 acres of surrounding private and municipal property. Milling operations generated 2.5 million cubic yards of waste (tailings) from 1942 to 1960. The tailings were impounded at four locations on the mill site. Inorganic constituents in the tailings drained from the impoundments to contaminate local surface water (Montezuma Creek) and groundwater in the underlying alluvial aquifer. Mill tailings dispersed by wind and water also contaminated properties surrounding and downstream of the mill site. Remedial actions to remove and isolate radiologically contaminated soil, sediment, and debris from the former mill site, Operable Unit I (OU I), and surrounding properties (OU II) were completed in 1999 with the encapsulation of the wastes in an engineered repository located on DOE property 1 mile south of the former mill site. This effectively removed the primary source of groundwater contamination; however, contamination of groundwater and surface water remains within OU III at levels that exceed water quality protection standards. Uranium is the primary contaminant of concern (COC). LM implemented monitored natural attenuation with institutional controls as the OU III remedy in 2004. Because groundwater restoration proceeded more slowly than expected and did not meet performance criteria established in the OU III Record of Decision (June 2004), LM implemented a contingency action in 2009 by an Explanation of Significant Difference to include a pump-and­ treat system using a single extraction well and treatment by zero-valent iron (ex situ treatment system). The contingency action was optimized in 2015 with the installation of8 extraction wells and 16 monitoring wells in a focused area of the aquifer, the area of attainment (AOA). Contaminated water is treated by solar evaporation at an existing facility at the LM repository.

54 ENVIRONMENTAL SCIENCES↗

Scaled Wind Farm Technology (SWiFT) Facility (Safety Assessment, Rev. 0)

This Safety Assessment (SA) documents the hazard analysis conducted for the Scaled Wind Farm Technology (SWiFT) Facility. The Sandia National Laboratories (SNL) Authorization Basis process requires Safety Assessment documents for all moderate-hazard industrial facilities. Together with the Primary Hazard Screening (PHS) Document [SNL11A00204), the SA documents the SWiFT safety basis, which is defined as the safety analysis and hazard controls that provide reasonable assurance that a DOE facility can be operated in a manner that adequately protects the workers, collocated/onsite workers, the public, and the environment. The SA specifically addresses the potential impact of hazards on the worker, collocated worker, and public.

17 WIND ENERGY↗

The Single Event Error (SEE) test and analysis of the CMS Endcap Timing Layer readout chip

The ETROC2, the first full size and full functionality prototype chip for the CMS Endcap Timing Layer readout, is strategically designed to meet the SEE immunity requirements of detector operation with the low power constraint. The triplicated periphery and pixel I2C configuration registers are designed with self-correction feature. The pixel readout control is centralized in the global readout and fully triplicated. The pixel readout is not triplicated, instead protected with power-efficient one-bit correction Hamming code. The TMR protection of the on-pixel threshold calibration can be turned off allowing the detection of the beam spot during the beam test by checking the bit-flips of the internal memory cells. In the initial proton beam test in January 2024, the chip readout process did not hang throughout the tests. The Hamming code correction strategy works because the error corrected TDC data were observed in the data frames. The error-injection simulation is performed to analy ze the small number of bit-flips in the configuration registers. We also performed SEE testing with a heavy ion beam in April and the data analysis is ongoing. The detailed design on the SEE immunity and the testing as well as simulation results will be presented, including follow-up SEE testing results in May and June 2024.

Gong, Datao↗

Quantum Key Distribution for Critical Infrastructures: Towards Cyber-Physical Security for Hydropower and Dams

Hydropower facilities are often remotely monitored or controlled from a centralized remote control room. Additionally, major component manufacturers monitor the performance of installed components, increasingly via public communication infrastructures. While these communications enable efficiencies and increased reliability, they also expand the cyber-attack surface. Communications may use the internet to remote control a facility’s control systems, or it may involve sending control commands over a network from a control room to a machine. The content could be encrypted and decrypted using a public key to protect the communicated information. These cryptographic encoding and decoding schemes become vulnerable as more advances are made in computer technologies, such as quantum computing. In contrast, quantum key distribution (QKD) and other quantum cryptographic protocols are not based upon a computational problem, and offer an alternative to symmetric cryptography in some scenarios. Although the underlying mechanism of quantum cryptogrpahic protocols such as QKD ensure that any attempt by an adversary to observe the quantum part of the protocol will result in a detectable signature as an increased error rate, potentially even preventing key generation, it serves as a warning for further investigation. In QKD, when the error rate is low enough and enough photons have been detected, a shared private key can be generated known only to the sender and receiver. We describe how this novel technology and its several modalities could benefit the critical infrastructures of dams or hydropower facilities. The presented discussions may be viewed as a precursor to a quantum cybersecurity roadmap for the identification of relevant threats and mitigation.

97 MATHEMATICS AND COMPUTING↗

Integration of Utility Distributed Energy Resource Management System and Aggregators for Evolving Distribution System Operators

With the rapid integration of distributed energy resources (DERs), distribution utilities are faced with new and unprecedented issues. New challenges introduced by high penetration of DERs range from poor observability to overload and reverse power flow problems, under-over-voltages, maloperation of legacy protection systems, and requirements for new planning procedures. Distribution utility personnel are not adequately trained, and legacy control centers are not properly equipped to cope with these issues. Fortunately, distribution energy resource management systems (DERMSs) are emerging software technologies aimed to provide distribution system operators (DSOs) with a specialized set of tools to enable them to overcome the issues caused by DERs and to maximize the benefits of the presence of high penetration of these novel resources. However, as DERMS technology is still emerging, its definition is vague and can refer to very different levels of software hierarchies, spanning from decentralized virtual power plants to DER aggregators and fully centralized enterprise systems (called utility DERMS). Although they are all frequently simply called DERMS, these software technologies have different sets of tools and aim to provide different services to different stakeholders. This paper explores how these different software technologies can complement each other, and how they can provide significant benefits to DSOs in enabling them to successfully manage evolving distribution networks with high penetration of DERs when they are integrated together into the control centers of distribution utilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

WEST actively cooled load resilient ion cyclotron resonance heating system results

Three identical new WEST ion cyclotron resonance heating (ICRH) antennas have been designed, assembled then commissioned on plasma from 2013 to 2019. The WEST ICRH system is both load-resilient and compatible with long-pulse operations. The three antennas have been successfully operated together on plasma in 2019 and 2020, with up to 5.8 MW of coupled power. The load resilience capability has been demonstrated and the antenna feedback controls for phase and matching have been developed. The breakdown detection systems have been validated and successfully protected the antennas. The use of ICRH in combination with lower hybrid has triggered the first high confinement mode transitions identified on WEST.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Practical issues and applications for vacuum and hermetic microsystems packaging.

Microsystems packaging involves physically placing and electrically interconnecting a microelectronic device in a package that protects it from and interfaces it with the outside world. When the device requires a hermetic or controlled microenvironment, it is typically sealed within a cavity in the package. Sealing involves placing and attaching a lid, typically by welding, brazing, or soldering. Materials selection (e.g., the epoxy die attach), and process control (e.g., the epoxy curing temperature and time) are critical for reproducible and reliable microsystems packaging. This paper will review some hermetic and controlled microenvironment packaging at Sandia Labs, and will discuss materials, processes, and equipment used to package environmentally sensitive microelectronics (e.g., MEMS and sensors).

36 MATERIALS SCIENCE↗

Practical issues and applications for vacuum and hermetic microsystems packaging.

Microsystems packaging involves physically placing and electrically interconnecting a microelectronic device in a package that protects it from and interfaces it with the outside world. When the device requires a hermetic or controlled microenvironment, it is typically sealed within a cavity in the package. Sealing involves placing and attaching a lid, typically by welding, brazing, or soldering. Materials selection (e.g., the epoxy die attach), and process control (e.g., the epoxy curing temperature and time) are critical for reproducible and reliable microsystems packaging. This paper will review some hermetic and controlled microenvironment packaging at Sandia Labs, and will discuss materials, processes, and equipment used to package environmentally sensitive microelectronics (e.g., MEMS and sensors).

36 MATERIALS SCIENCE↗

Novel Authentication of Monitoring Data Through the use of Secret and Public Cryptographic Keys

The Office of Nuclear Verification (ONV) is supporting the development of a piece of equipment to provide data authentication and protection for a suite of monitoring sensors as part of a larger effort to create an arms control technology toolkit. This device, currently called the Red Box, leverages the strengths of both secret and public cryptographic keys to authenticate, digitally sign, and pass along monitoring data to allow for host review, and redaction if necessary, without the loss of confidence in the authenticity of the data by the monitoring party. The design of the Red Box will allow for the addition and removal of monitoring equipment and can also verify that the data was collected by authentic monitoring equipment prior to signing the data and sending it to the host and for review. The host will then forward the data to the monitor for review and inspection. This paper will highlight the progress to date of the Red Box development, and will explain the novel method of leveraging both symmetric and asymmetric (secret and public key) cryptography to authenticate data within a warhead monitoring regime.

Benz, Jacob M.↗

Consequence-driven cyber-informed engineering and related systems and methods

Embodiments of the disclosure relate to a computer-implemented consequence-driven cyber-informed engineering tool for performing and reporting consequence-based prioritization, system-of-systems breakdown, consequence-based targeting, and mitigations and protections. Embodiments of a CCE tool may perform one or more steps of defining a target industrial control system (ICS), wherein the target ICS includes operational goals, critical functions, and critical services; determining one or more scored high consequence events (HCE) associated with the defined target ICS; prioritizing the scored HCEs according to an HCE severity index; and updating a dashboard with one or more representations of the prioritized HCEs, wherein the updated dashboard is associated with the CCE tool and presented at a display.

Assante, Michael↗

Design and Construction of a Loess-Cement Cushion as an Integral Component of an SL-LILW Repository - 16077

The Bulgarian State Enterprise for Radioactive Waste Management (SERAW) is planning the construction of a near-surface repository for short-lived low and intermediate level radioactive waste, the National Disposal Facility (NDF), adjacent to the Kozloduy Nuclear Power Plant (KNPP). The NDF will be constructed as a reinforced concrete vault-type repository system, where prefabricated cubic waste packages (2 m on a side) will be emplaced in large reinforced concrete disposal cells. Waste emplacement operations will be conducted in three phases over a total of 60 years of operations. After the last waste packages have been disposed, an engineered multilayer cover will be installed over the site to further isolate the waste from the accessible environment. The Radiana Site where the NDF will be constructed is a sloping area located between the second and sixth loess terraces above the River Danube with elevations ranging from approximately +40 m to elevation +95 m. The unsaturated zone at the location selected for waste disposal ranges from 13 m to 16 m in thickness. After construction, the unsaturated zone will consist of a 5 m thick, engineered loess-cement cushion installed over naturally occurring Pliocene clays and sandy clayey sediments of the Brusarci Formation with a thickness above the top of groundwater ranging from 8 m to 11 m. The loess-cement cushion is a key component of the 'engineered fill' barrier as identified in the Intermediate Safety Assessment Report (ISAR) for the NDF. This barrier consists of engineered fill both below the disposal cells, i.e., the loess-cement cushion, and above the disposal cells, i.e. the final multilayer cover to be installed at closure of the facility. The loess-cement cushion component of this barrier will act to provide a geo-technically stable foundation for the disposal system. In addition, the barrier will raise the base of the disposal cells and increases the unsaturated zone thickness above the top of the groundwater table, as well as to serve as a chemical barrier that will act to sorb radionuclides thereby retarding their migration to the underlying groundwater. In addition to its assigned barrier functions the loess cement cushion also houses key embedded components required as part of the overall NDF safety concept, including systems necessary for operational and post-closure performance monitoring as well as the support foundation structures required for the mobile roofs, which are designed to handle and protect the waste during emplacement operations. The post-closure monitoring period, i.e., the period of institutional control, is given by as 300 years. While similar although less massive cushions have been previously constructed as foundations for various structures at the KNPP, the loess-cement cushion planned for construction at the NDF including the embedded structures will represent a first of its kind construction in terms of both its physical dimensioning as well as its requirements for long-term performance. This paper describes the design of the cushion, its functions and its construction as planned for the NDF as an integral component of the site safety concept. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Comparison of Two Alternative Types of Unmanned Aerial Vehicles for Indoor Spaces - 18502

This paper examines two lesser known, but technological mature, unmanned aerial vehicle (UAVs) approaches to working in indoor spaces. Tethered UAVs reduce safety concerns by physically limiting the range of the UAV. The tether can provide other advantages including supplying long-term power, carrying heavier payloads, enabling uninterrupted communications, better performance in high winds, and providing more flexibility in viewpoints than an aerial mast. Caged UAVs reduce safety concerns by protecting the UAV, and its environment, form damage due to collisions or contact. The protective cage can offer other advantages including bracing or rolling the UAV over a surface to simply control or reduce energy, lessen wind resistance, and allow the UAV to inspect a structure at close, repeatable distances. The paper established the problems associated with flying UAVs in indoor spaces. It reviews the state of the practice for both tethered and caged UAVs, then compares the two approaches to traditional multi-rotor UAVs. The paper concludes that commercially available tethered and caged UAVs are useful and ready for immediate adoption. (authors)

42 ENGINEERING↗

FRMAC Assessment Manual Volume 1: Overview and Methods

This Federal Radiological Monitoring and Assessment Center (FRMAC) Assessment Manual has been prepared by representatives of those Federal and State agencies that can be expected to play the major roles during a radiological emergency. Federal Agencies include: the National Nuclear Security Administration (NNSA), the Nuclear Regulatory Commission (NRC), the Environmental Protection Agency (EPA), the Department of Agriculture (USDA), the Food and Drug Administration (FDA), and the Centers for Disease Control (CDC). This final manual was reviewed by experts from across the community and their input has been incorporated.

61 RADIATION PROTECTION AND DOSIMETRY↗

Solid State Transformer Controls for Mitigation of E3a High-Altitude Electromagnetic Pulse Insults

This paper explores the use of a solid state transformer (SST) to mitigate the 𝐸 3𝐴 component of a high-altitude electromagnetic pulse (HEMP) insult using external energy storage optimal control techniques. In lieu of conventional passive blocking devices or feedback-controlled energy storage devices, a novel implementation of Hamiltonian error tracking is utilized to develop a feedback control law for the variable converter ratio in an SST. The findings of the simulations performed in this paper suggest that additional energy storage is not necessary to protect an individual load from a HEMP insult. The simulations performed examine the response of a single-phase SST connected to a single voltage source on a long transmission line on the one side and a single linear resistor on the other. The control law is specifically developed for the late-time, low-frequency portion of a HEMP insult, namely the 𝐸 3𝐴 components. The Hamiltonian error-based converter ratio control law is compared with nonlinear optimal feedforward controls to show that the HSSPFC is an external energy storage optimal controller.

HEMP mitigation↗

SU-F-P-64: The Impact of Plan Complexity Parameters On the Plan Quality and Deliverability of Volumetric Modulated Arc Therapy with Canonical Correlation Analysis

Purpose: To evaluate the impact of complexity indices on the plan quality and deliverability of volumetric modulated arc therapy (VMAT), and to determine the most significant parameters in the generation of an ideal VMAT plan. Methods: A multi-dimensional exploratory statistical method, canonical correlation analysis (CCA) was adopted to study the correlations between VMAT parameters of complexity, quality and deliverability, as well as their contribution weights with 32 two-arc VMAT nasopharyngeal cancer (NPC) patients and 31 one-arc VMAT prostate cancer patients. Results: The MU per arc (MU/Arc) and MU per control point (MU/CP) of NPC were 337.8±25.2 and 3.7±0.3, respectively, which were significantly lower than those of prostate cancer patients (MU/Arc : 506.9±95.4, MU/CP : 5.6±1.1). The plan complexity indices indicated that two-arc VMAT plans were more complex than one-arc VMAT plans. Plan quality comparison confirmed that one-arc VMAT plans had a high quality than two-arc VMAT plans. CCA results implied that plan complexity parameters were highly correlated with plan quality with the first two canonical correlations of 0.96, 0.88 (both p<0.001) and significantly correlated with deliverability with the first canonical correlation of 0.79 (p<0.001), plan quality and deliverability was also correlated with the first canonical correlation of 0.71 (p=0.02). Complexity parameters of MU/CP, segment area (SA) per CP, percent of MU/CP less 3 and planning target volume (PTV) were weighted heavily in correlation with plan quality and deliveability . Similar results obtained from individual NPC and prostate CCA analysis. Conclusion: Relationship between complexity, quality, and deliverability parameters were investigated with CCA. MU, SA related parameters and PTV volume were found to have strong effect on the plan quality and deliverability. The presented correlation among different quantified parameters could be used to improve the plan quality and the efficiency of the radiotherapy process when creating a complex VMAT plan.

60 APPLIED LIFE SCIENCES↗

A Real-Time ANPC Inverter Digital Twin with Integrated Design-For-Trust

The demand for renewable energy has increased over the last few years, and so has the demand for greater expectations within the energy market. This increasing trend has been accompanied by more significant usage of internet-connected devices (IoT), leading to critical electrical infrastructure being connected to the internet. Implementing internet connectivity with such devices and systems provides benefits such as improving the system's performance, facilitating irregularity and anomaly mitigation, and providing additional situational awareness for enhanced decision-making. However, enhancing the connected system with IoT introduces a drawback – a greater vulnerability to cyber-attacks. Cyber-attacks targeting critical infrastructure in the electrical sector have occurred in the United States and Ukraine. These cyber-attacks highlight and expose vulnerabilities that a system inherits when connecting to the internet. These attacks left thousands of customers without electricity for hours until operators could regain control of the electric utility grid. Therefore, to address the vulnerabilities of an internet-connected power electronic device, this work focused on the hardware layer of the system. Implementing a cyber-control system inside the hardware layer can significantly reduce the possibility of an attacker patching malicious controller firmware into a photovoltaic grid-connected inverter, thus mitigating the likelihood that the inverter becomes inactive a cyber-attack scenario. With this mitigation technique, if a cyberattack is successful and an attacker gains control of the network, a cyber-defense technique is in place to mitigate the impact of the cyber-attack. This additional protection layer was developed based on an innovative concept known as Digital Twin (DT). A DT, in this case, replicates an Active-Neutral Point Clamped (ANPC) inverter and was designed using a hardware language known as VHDL (Very High-Speed Integrated Circuit Hardware Description Language) and applied to Field-Programmable-GateArray (FPGA). The DT is embedded within the FPGA and contained in a controller board, the UCB (Unified Controller Board), developed by the University of Arkansas electrical engineering team. This UCB also contains two Digital Signal Processors (DSPs) responsible for generating associated signals to control an authentic physical inverter. These DSP signals are received and processed by the FPGA that implements the DT of an ANPC; in other words, it simulates in realtime the expected output of an actual ANPC inverter using the signals from the DSP. When a new firmware is ready to be patched, the DT provides output signals simulating behavior that a real ANPC inverter would generate with the new firmware. The new firmware is tested to check if it meets all the operational requirements established using a Design-For-Trust technique (DFTr). If the new firmware fails in at least one of the DFT tests, it is considered malicious and must be rejected. This work is divided into sections, such as Background, which explains the pieces that were used and the strategy behind this work; Process and Procedure, which explains the methodology that was adopted to prove the reliability and effectiveness of this work; Results and Discussion, where the simulations and results are described and explained; followed by Conclusion and Future work section, which concludes this work and adds possible future projects to continue this work further.

do Amaral Custodio, Paulo Vitor↗

Real-Time Testbed for Smart Grid Recloser Controller

The growing need for a low voltage recloser has become apparent due to the rise in requirements for a smart grid. This includes more detailed management of power flow forward (towards load) and backward (towards generation), source synchronization in real time, more indepth fault responses, and the use of green energy. The SEL-651R-2 relay is a device that can manage these needs, especially in fault response and synchronization, and is commonly used in systems called microgrids. Microgrids are distribution level systems that are able to operate separated from the main grid, are typically installed much closer to the load(s), and are fed by distributed energy resources (DERs), such as wind, solar or diesel generators. The SEL-651R-2 is normally used in the field with presets operative settings, but the Western Michigan University (WMU) Center for Interdisciplinary Research on Secure, Efficient and Sustainable Energy Technology (WMU InterEnergy Center) wished to test this device in its range of capabilities for microgrid application. A Hardware-In-the-Loop (HIL) testbed was implemented and used through the Real Time Digital Simulator (RTDS) using the RSCAD software to test the SEL-651R-2's use cases and functions. The testbed includes a microgrid with interconnection to a larger main grid, and the relay is meant to control the recloser at the point of common coupling (PCC) between the main grid and microgrid. The testbed shows how basic protections, reclosing, and synchronization checks function when handling faults that affect both the microgrid and the main grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MO-AB-210-03: Workshop [ Advancements in high intensity focused ultrasound ]

The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.

60 APPLIED LIFE SCIENCES↗