Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power consistency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Searching for anisotropic cosmic birefringence with polarization data from SPTpol

In this paper, we present a search for anisotropic cosmic birefringence in 500 deg 2 of southern sky observed at 150 GHz with the SPTpol camera on the South Pole Telescope. We reconstruct a map of cosmic polarization rotation anisotropies using higher-order correlations between the observed cosmic microwave background (CMB) E and B fields. We then measure the angular power spectrum of this map, which is found to be consistent with zero. The nondetection is translated into an upper limit on the amplitude of the scale-invariant cosmic rotation power spectrum, L ( L + 1 ) C L α α / 2 π < 0.10 × 10 – 4 rad 2 ( 0.033 deg 2 , 95% C.L.). This upper limit can be used to place constraints on the strength of primordial magnetic fields, B 1 Mpc < 17 nG (95% C.L.), and on the coupling constant of the Chern-Simons electromagnetic term g a γ < 4.0 × 10 – 2 / H I (95% C.L.), where H I is the inflationary Hubble scale. For the first time, we also cross-correlate the CMB temperature fluctuations with the reconstructed rotation angle map, a signal expected to be nonvanishing in certain theoretical scenarios, and find no detectable signal. We perform a suite of systematics and consistency checks and find no evidence for contamination.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Helicity methods for high multiplicity subleading soft and collinear limits

The factorization of multi-leg gauge theory amplitudes in the soft and collinear limits provides strong constraints on the structure of amplitudes, and enables efficient calculations of multi-jet observables at the LHC. There is significant interest in extending this understanding to include subleading powers in the soft and collinear limits. While this has been achieved for low point amplitudes, for higher point functions there is a proliferation of variables and more complicated phase space, making the analysis more challenging. By combining the subleading power expansion of spinor-helicity variables in collinear limits with consistency relations derived from the soft collinear effective theory, we show how to efficiently extract the subleading power leading logarithms of N-jet event shape observables directly from known spinor-helicity amplitudes. At subleading power, we observe the presence of power law singularities arising solely from the expansion of the amplitudes, which for hadron collider event shapes lead to the presence of derivatives of parton distributions. The techniques introduced here can be used to efficiently compute the power corrections for N-jettiness subtractions for processes involving jets at the LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of Temperature Compensation Tools for SPNDs Operating in High Temperature Environments

Two rhodium-based self-powered neutron detectors (Rh-SPNDs) were irradiated at the Massachusetts Institute of Technology Reactor as a follow-on experiment to the heated irradiation previously conducted at the Neutron Radiography facility at Idaho National Laboratory. The experiment was conducted over the temperature ranges of 600-850°C to further examine the effects of temperature on the Rh-SPNDs. Four tests of varying temperature and power were performed. The tests identified two types of temperature effects consistent with historical evaluations. One effect is a prompt proportionality to temperature at steady-state reactor power due to the decrease in Rh-SPND insulation resistance. The other effect is a delayed effect generated from displacement currents generated by changing the space charge within the insulator as a function of temperature. The result of this experiment demonstrates a characterizable responses to temperature that is feasible for developing a temperature compensation tool for SPND operating in high temperatures. The characteristics identified in this experiment will be integrated within the delayed-response compensation techniques for FY23 evaluation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A COMPACT GROUP OF GALAXIES AT Z = 2.48 HOSTING AN AGN-DRIVEN OUTFLOW

We present observations of a remarkable compact group of galaxies at z = 2.48. Four galaxies, all within 40 kpc of each other, surround a powerful high-redshift radio source. This group comprises two compact red passive galaxies and a pair of merging galaxies. One of the red galaxies, with an apparent stellar mass of 3.6 × 10{sup 11}M{sub ⊙} and an effective radius of 470 pc, is one of the most extreme examples of a massive quiescent compact galaxy found so far. One of the pair of merging galaxies hosts the active galactic nucleus (AGN) producing the large powerful radio structure. The merger is massive and enriched, consistent with the mass–metallicity relation expected at this redshift. Close to the merging nuclei, the emission lines exhibit broad and asymmetric profiles that suggest outflows powered either by a very young expanding radio jet or by AGN radiation. At ≳50 kpc from the system, we found a fainter extended-emission region that may be a part of a radio-jet-driven outflow.

79 ASTRONOMY AND ASTROPHYSICS↗

Topological Superconductivity in the Doped Chiral Spin Liquid on the Triangular Lattice

It has been established that the undoped, i.e., δ = 0 , system has a CSL ground state in the parameter region 0.32 ≤ J χ / J ≤ 0.56 . Upon light doping, we find that the ground state of the system is consistent with a Luther-Emery liquid with power-law superconducting and charge-density-wave correlations but short-range spin-spin correlations. In particular, the superconducting correlations, whose pairing symmetry is consistent with d ± i d wave, are dominant at all hole doping concentrations. Overall, our results provide direct evidences that doping the CSL on the triangular lattice can naturally give rise to topological superconductivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Changes in aerobic power of men, ages 25-70 yr

This study quantified and compared the cross-sectional and longitudinal influence of age, self-report physical activity (SR-PA), and body composition (%fat) on the decline of maximal aerobic power (VO2peak). The cross-sectional sample consisted of 1,499 healthy men ages 25-70 yr. The 156 men of the longitudinal sample were from the same population and examined twice, the mean time between tests was 4.1 (+/- 1.2) yr. Peak oxygen uptake was determined by indirect calorimetry during a maximal treadmill exercise test. The zero-order correlations between VO2peak and %fat (r = -0.62) and SR-PA (r = 0.58) were significantly (P < 0.05) higher that the age correlation (r = -0.45). Linear regression defined the cross-sectional age-related decline in VO2peak at 0.46 ml.kg-1.min-1.yr-1. Multiple regression analysis (R = 0.79) showed that nearly 50% of this cross-sectional decline was due to %fat and SR-PA, adding these lifestyle variables to the multiple regression model reduced the age regression weight to -0.26 ml.kg-1.min-1.yr-1. Statistically controlling for time differences between tests, general linear models analysis showed that longitudinal changes in aerobic power were due to independent changes in %fat and SR-PA, confirming the cross-sectional results.

Oxygen Consumption/physiology↗

Space station WP-04 power system. Volume 1: Executive summary

Major study activities and results of the phase B study contract for the preliminary design of the space station Electrical Power System (EPS) are summarized. The areas addressed include the general system design, man-tended option, automation and robotics, evolutionary growth, software development environment, advanced development, customer accommodations, operations planning, product assurance, and design and development phase planning. The EPS consists of a combination photovoltaic and solar dynamic power generation subsystem and a power management and distribution (PMAD) subsystem. System trade studies and costing activities are also summarized.

Hallinan, G. J.↗

Recent Advances in Power Conversion and Heat Rejection Technology for Fission Surface Power

Under the Exploration Technology Development Program, the National Aeronautics and Space Administration (NASA) and the Department of Energy (DOE) are jointly developing Fission Surface Power (FSP) technology for possible use in human missions to the Moon and Mars. A preliminary reference concept was generated to guide FSP technology development. The concept consists of a liquid-metal-cooled reactor, Stirling power conversion, and water heat rejection, with Brayton power conversion as a backup option. The FSP project has begun risk reduction activities on some key components with the eventual goal of conducting an end-to-end, non-nuclear, integrated system test. Several power conversion and heat rejection hardware prototypes have been built and tested. These include multi-kilowatt Stirling and Brayton power conversion units, titanium-water heat pipes, and composite radiator panels.

Mason, Lee↗

PG&E WaveConnect Program (Final Report)

The PG&E WaveConnect project was intended to demonstrate the technical and economic viability of wave power in the open ocean adjacent to PG&E's service territory. WaveConnect was conceived as a multi-stage development process leading to long-term megawatt-scale wave power production. The first-stage tasks consisted of site selection, permitting, pilot plant design, and assessment of technology and commercial readiness. The second stage would have included development of infrastructure, undersea cabling, and deployment of wave energy conversion devices (WECs). In the third stage, the most promising WEC devices would have been deployed in larger quantities and connected to the grid. This report documents the findings of Stage One. Site Selection: After studying the wave energy potential, grid interconnection and other project infrastructure along the California coast, PG&E selected two sites: one near Eureka, called the Humboldt WaveConnect (HWC) project, and another near Vandenberg Air Force Base, called the Central Coast WaveConnect project (CCWC).

16 TIDAL AND WAVE POWER↗

The Dark Energy Camera All Data Everywhere cosmic shear project V: Constraints on cosmology and astrophysics from 270 million galaxies across 13,000 deg$^2$ of the sky

We present constraints on models of cosmology and astrophysics using cosmic shear data vectors from three datasets: the northern and southern Galactic cap of the Dark Energy Camera All Data Everywhere (DECADE) project, and the Dark Energy Survey (DES) Year 3. These data vectors combined consist of 270 million galaxies spread across 13,000 ${\rm deg}^2$ of the sky. We first extract constraints for $Λ$CDM cosmology and find $S_8= 0.805^{+0.019}_{-0.019}$ and $Ω_{\rm m} = 0.262^{+0.023}_{-0.036}$, which is consistent within $1.9 σ$ of constraints from the Planck satellite. Extending our analysis to dynamical dark energy models shows that lensing provides some (but still minor) improvements to existing constraints from supernovae and baryon acoustic oscillations. Finally, we study six different models for the impact of baryons on the matter power spectrum. We show the different models provide consistent constraints on baryon suppression, and associated cosmology, once the astrophysical priors are sufficiently wide. Current scale-cut approaches for mitigating baryon contamination result in a residual bias of $\approx 0.3σ$ in the $S_8, Ω_{\rm m}$ posterior. Using all scales with dedicated baryon modeling leads to negligible improvement as the new information is used solely to self-calibrate the baryon model on small scales. Additional non-lensing datasets, and/or calibrations of the baryon model, will be required to access the full statistical power of the lensing measurements. The combined dataset in this work represents the largest lensing dataset to date (most galaxies, largest area) and provides an apt testing ground for analyses of upcoming datasets from Stage IV surveys. The DECADE shear catalogs, data vectors, and likelihoods are made publicly available.

Anbajagane, D. [Chicago U., Astron. Astrophys. Ctr↗

Analysis of combustion spectra containing organ pipe tone by cepstral techniques

Signal reinforcements and cancellations due to standing waves may distort constant bandwidth combustion spectra. Cepstral techniques previously applied to the ground reflection echo problem are used to obtain smooth broadband data and information on combustion noise propagation. Internal fluctuating pressure measurements made using a J47 combustor attached to a 6.44 m long duct are analyzed. Measurements made with Jet A and hydrogen fuels are compared. The acoustic power levels inferred from the measurements are presented for a range of low heat release rate operating conditions near atmospheric pressure. For these cases, the variation with operating condition of the overall acoustic broadband power level for both hydrogen and Jet A fuels is consistent with previous results showing it was proportional to the square of the heat release rate. However, the overall acoustic broadband power level generally is greater for hydrogen than for Jet A.

Miles, J. H.↗

Reliable Optical Pump Architecture for Highly Coherent Lasers Used in Space Metrology Applications

The design and initial demonstration of a laser pump module (LPM) incorporating single-mode, grating-stabilized 808-nm diode lasers and a low-loss, high-port-count optical combiner are completed. The purpose of the developed LPM is to reliably pump an Nd:YAG crystal in the laser head (LH), which serves as the optical metrology source for SIMLite mission. Using the narrow-linewidth, single-mode laser diodes enables placement of the pump power near Nd adsorption peak, which enhances pumping efficiency. Grating stabilization allows for stable pump spectra as diode operating temperature and bias current change. The low-loss, high-port-count optical combiner enables efficient combining of tens of pumps. Overall, the module supports 5+ years of continuous operation at 2 W of pump power with reliability approaching 100 percent. The LPM consists of a laser diode farm (LDF) and a pump beam combiner (PBC). An array of 807- to 808-nm fiber-pigtailed laser diodes makes up the LDF. A Bragg grating in each 5- m core single-mode (SM) fiber pigtail acts to stabilize the lasing spectra over a range of diode operating conditions. These commercially available single-mode laser diodes can deliver up to 150 mW of optical power. The outputs from the multiple pumps in the LDF are routed to the PBC, which is a 37-input by 1-output all-fiber device. The input ports consist of 5- m core SM fiber, while the output port consists of 105- m core, 0.15 NA (numerical aperture) multi-mode (MM) fiber. The combiner is fabricated by fusing the 37 input fibers while simultaneously tapering the fused region. At the completion of this process, the MM fiber is spliced to the end of the adiabatic taper, and, for protection, the combiner is sheathed by a capillary tube. A compact and robust metal housing was designed and fabricated to protect the PBC during space deployment.

Erlig, Herman↗

An 8-GW long-pulse generator based on Tesla transformer and pulse forming network

A long-pulse generator TPG700L based on a Tesla transformer and a series pulse forming network (PFN) is constructed to generate intense electron beams for the purpose of high power microwave (HPM) generation. The TPG700L mainly consists of a 12-stage PFN, a built-in Tesla transformer in a pulse forming line, a three-electrode gas switch, a transmission line with a trigger, and a load. The Tesla transformer and the compact PFN are the key technologies for the development of the TPG700L. This generator can output electrical pulses with a width as long as 200 ns at a level of 8 GW and a repetition rate of 50 Hz. When used to drive a relative backward wave oscillator for HPM generation, the electrical pulse width is about 100 ns on a voltage level of 520 kV. Factors affecting the pulse waveform of the TPG700L are also discussed. At present, the TPG700L performs well for long-pulse HPM generation in our laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

InGaAs/InP Monolithic Interconnected Modules (MIM) for Thermophotovoltaic Applications

There has been a traditional trade-off in thermophotovoltaic (TPV) energy conversion development between systems efficiency and power density. This trade-off originates from the use of front surface spectral controls such as selective emitters and various types of filters. A monolithic interconnected module (MIM) structure has been developed which allows for both high power densities and high system efficiencies. The MIM device consists of many individual indium gallium arsenide (InGaAs) devices series -connected on a single semi-insulating indium phosphide (InP) substrate. The MIMs are exposed to the entire emitter output, thereby maximizing output power density. An infrared (IR) reflector placed on the rear surface of the substrate returns the unused portion of the emitter output spectrum back to the emitter for recycling, thereby providing for high system efficiencies. Initial MIM development has focused on a 1 sq cm device consisting of eight series interconnected cells. MIM devices, produced from 0,74 eV InGAAs, have demonstrated V(sub infinity) = 3.23 volts, J(sub sc) = 70 mA/sq cm and a fill factor of 66% under flashlamp testing. Infrared (IR) reflectance measurement (less than 2 microns) of these devices indicate a reflectivity of less than 82%. MIM devices produced from 0.55 eV InGaAs have also been den=monstrated. In addition, conventional p/n InGaAs devices with record efficiencies (11.7% AM1) have been demonstrated.

Wilt, David M.↗

AOI-2, A Novel Access Control Blockchain Paradigm for Cybersecure Sensor Infrastructure in Fossil Power Generation Systems

Fossil power generation systems are increasingly vulnerable to attack from both cybercriminals as well as internal threats. These vulnerabilities demand that emerging technologies such as blockchains be utilized to secure the data involved in the information flows within the Supervisory Control and Data Acquisition (SCADA) systems of the fossil power generation plants. The publicly accessible blockchain protocols, although secure, are visible to everyone. Even private blockchains currently are unable to support different levels of access to different participants, which is a critical requirement for the existing SCADA systems running the power plants. In light of the above, novel blockchain protocols that are specifically adapted to fossil power generation environments need to be developed in order to achieve the goal of cybersecure sensor networks. In this work, we address this question by creating a novel blockchain technology, namely smart private ledger, for cybersecure communication within the fossil power generation systems. A lab-scale sensor network consisting of strain and temperature sensors is constructed to develop the ledger. The technology has hierarchical access control which is compatible with the existing SCADA systems in fossil power plants. The sensor data is used with cryptographic digital signatures and secret sharing protocols within the nodes of the blockchain technology. The research results will lead to cybersecurity for machine-to-machine interactions, infrastructure for secure data logging for sensors, decentralized data storage, and second-layer technologies for high volume machine-to-machine interactions in the power plants. The work aims to largely address the concerns for the security of distributed sensor networks in such systems that can be compromised by insider threats and by cybercriminals. The research has led to the training of the next generation of engineers and scientists in the important areas of sensor engineering and blockchain technology.

01 COAL, LIGNITE, AND PEAT↗

Design and performance of an actively collimated phoswich system for X-ray astronomy

The design and performance of a phoswich type scintillation detector system having 34 sq cm effective collecting area and a sensitivity of 3 x 10 to the -5th power photons/sq cm/s/keV for balloon-borne cosmic X-ray source observations are discussed. The various shield anticoincidence systems are evaluated for effectiveness in reduction of the system background. The total background of nominally 4 x 10 to the -4th power counts/sq cm/s/keV is analyzed and found to consist of aperture flux, K-escape X-rays from the shielding, leakage, and degradation of gamma-rays through the shielding, and several particle induced effects. The background analysis suggests an ultimate practical upper limit of about 8 x 10 to the -5th power counts/sq cm/s/keV might be attainable beyond which further sensitivity improvements will require increased collecting area or a basically differing design approach.

Matteson, J. L.↗