Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Management and Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

A Self-Sustained CPS Design for Reliable Wildfire Monitoring

Continuous monitoring of areas nearby the electric grid is critical for preventing and early detection of devastating wildfires. Existing wildfire monitoring systems are intermittent and oblivious to local ambient risk factors, resulting in poor wildfire awareness. Ambient sensor suites deployed near the gridlines can increase the monitoring granularity and detection accuracy. However, these sensors must address two challenging and competing objectives at the same time. First, they must remain powered for years without manual maintenance due to their remote locations. Second, they must provide and transmit reliable information if and when a wildfire starts. The first objective requires aggressive energy savings and ambient energy harvesting, while the second requires continuous operation of a range of sensors. To the best of our knowledge, this paper presents the first self-sustained cyber-physical system that dynamically co-optimizes the wildfire detection accuracy and active time of sensors. The proposed approach employs reinforcement learning to train a policy that controls the sensor operations as a function of the environment (i.e., current sensor readings), harvested energy, and battery level. Here, the proposed cyber-physical system is evaluated extensively using real-life temperature, wind, and solar energy harvesting datasets and an open-source wildfire simulator. In long-term (5 years) evaluations, the proposed framework achieves 89% uptime, which is 46% higher than a carefully tuned heuristic approach. At the same time, it averages a 2-minute initial response time, which is at least 2.5× faster than the same heuristic approach. Furthermore, the policy network consumes 0.6 mJ per day on the TI CC2652R microcontroller using TensorFlow Lite for Micro, which is negligible compared to the daily sensor suite energy consumption.

54 ENVIRONMENTAL SCIENCES↗

Prosumer-Based Distributed Autonomous Cyber-Physical Architecture for Ultra-reliable Green Electricity Internetworks

This project, the first of its kind, proposes a new architecture for decentralized management and control of future electricity grids with millions of decision-makers. These economically motivated decision-makers are called prosumers (producer-consumers). Prosumers can produce, consume, and/or store electricity and make strategic decisions enabled by communication networks. Prosumers can be as large as a utility or as small as an electric vehicle or a smart house with a home energy management system. The report first provides an impression of the functionality envisioned in prosumer-based smart grids and the philosophy behind their design. The architecture is intended to provide a platform for many possibilities in service definition and trading. The functionality of the architecture is identified by functional and non-functional requirements related to decentralized control and optimization. In this report, three key technologies are proposed for enabling distributed operation and control in prosumer-based smart grids. The first technology is a cyber-infrastructure model, which provides an underlying framework for distributed communication and computation in smart grids. The model is based on service-oriented computing paradigm and is compatible with the existing service-oriented technologies, used in enterprise computing, such as Web Services. However, it extends these technologies for handling the hard-to-predict real-time aspects of smart grids by introducing resource-aware service deployment and quality-of-service (QoS)-aware service monitoring phases. The second technology is a distributed frequency regulation (DFR) framework, which can ensure midterm frequency stability while avoiding inter-area oscillations and using a limited control effort. DFR can complement today’s Automatic Generation Control (AGC) systems by providing an advanced protocol for coordination between AGC systems of different prosumers. The main advantage of the DFR technology is that each frequency regulator only needs to communicate with its neighbors in the network. The efficacy of DFR is shown through simulations on real-world electric energy systems of different scale and complexity. The third technology introduced in this project is decentralized unit commitment (DUC) for heterogeneous prosumers. The DUC technology is a new scalable method for formulating and solving a distributed energy scheduling problem. The algorithm extends the alternating direction method of multipliers (ADMM) and includes several heuristics to mitigate oscillations and traps in local optimality that result from the nonconvexity of unit commitment. The main advantages of DUC is that it can solve the unit commitment problem for large-scale power systems of more than 3,000 nodes faster than the state-of-the-art, centralized methods, and that it is scalable to energy scheduling problems of prosumer systems of any size. In summary, this report illustrates that the distributed architecture for prosumer-based power grids is an enabler of transforming aging power grids into sustainable, resilient, reliable, and efficient smart grids with some desirable functionalities similar to the Internet.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Applications of data mining technology to enhance O and M: automatic planning of electrical isolation with deep learning - 255

Data mining technology is now readily available, thanks to high powered, low cost computing resource and useful coding tools. We study several applications of data mining to enhance operation and maintenance (O and M), such as abnormality prediction, efficiency diagnosis, document traceability, image recognition, etc. In field support, we try automatic planning of electrical isolation with deep learning. Currently, a skilled engineer plans electrical isolation procedure with hundreds of the circuit diagrams and the related documents, taking man-hours. If this task becomes automatic, it is very efficient. The automatic planning has two issues. One is much calculation time of electrical circuit simulator, searching billions of electrical conducting paths. The other is interpretation of human fuzzy information, such as ease of work. Deep learning is helpful to resolve them. We performed a model case study of the electrical isolation. We applied a deep neural network (DNN) for dropping in the calculation time. We trained the circuit diagrams and the responses of the circuit simulator to the DNN, constructing an efficient path search algorithm in the DNN. The calculation time of the DNN was shorter by a factor of 32 for the model case, compared with that of the electrical circuit simulator. We applied a deep Q-network (DQN) for the interpretation of fuzzy information. The DQN optimized isolation procedure from the viewpoint of the work load with the equipment layout, related doses, and values of wet bulb globe temperature (WBGT) to prevent heatstroke. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, Construction, and Assessment of Dry Coal Feeding in a High Pressure Oxy-coal System

Reaction Engineering International (REI) has managed a team of experts from the University of Utah, Southeast University (SEU) in Nanjing, China, Electric Power Research Institute (EPRI), Corrosion Management Ltd. (C-M), Praxair, and Brigham Young University (BYU) to investigate dry pulverized coal feeding for pressurized oxy-coal combustion. Dry feed firing systems for entrained flow, pressurized, oxy-coal combustors have not been well developed, although related technologies have been used in the Shell Gasification Process and for pressurized fluid bed combustion. DOE-funded research recently completed at REI and the University of Utah focused on characterizing impacts of high temperatures and pressures in oxy-coal combustion systems. For high pressure combustion, that research used a coal slurry feed into a 17 bar pressurized combustor. As a consequence of that research, it was identified that fuel feeding and firing system flexibility are challenges that require attention. Based on that experience, the approach of using a coal slurry feed system leads to challenges in producing consistent atomization of the slurry, which causes burnout problems, especially at high pressures. In addition, slurry atomization processes may be difficult to scale to sizes appropriate for practical commercial use. Dry pressurized coal burner systems, on the other hand, have the potential to yield efficiency gains, improve flexibility and facilitate applications at larger scales. Experimental work was conducted at the University of Utah Industrial Combustion and Gasification Research Facility as well as the 100 kW pressurized oxy-coal combustor (POC) facility at Brigham Young University. Mechanism development and CFD-based combustion and dense-phase flow modeling were performed at REI. Successful completion of the project objectives has resulted in the following key deliverables: 1) Design and prototype of a pressurized pulverized coal feeding and oxy-firing system 2) Data from a 100kW, pressurized (15 bar) entrained flow reactor with a dry feeding delivery and burner system that describes flame characteristics, radiative heat flux profiles, carbon burnout, along with characteristics of ash aerosols, fouling, and slagging. 3) Validated and transportable models that describe the relevant conditions in pressurized oxy-combustion systems and that can be used for scale-up and optimization. 4) Principles to guide design of high pressure, pilot-scale and full-scale coal oxy-firing systems. 5) Assessment of pressurized oxy-combustion impacts on key parameters relevant to oxy-coal fired utility boilers such as coal devolatilization, char oxidation, mineral matter transformation, deposition, and corrosion. The experimental data, pressurized oxy-firing system principles, and process mechanisms provided by this work can be used by electric utilities, boiler OEMs, equipment suppliers, design firms, software vendors, consultants and government agencies to assess the use of high temperature and high pressure oxy-combustion in current research and to guide development of new oxy-coal boiler designs.

pressurized oxy-coal combustion, sub-micron ash ae↗

Characterizing Impacts of Dry Coal Feeding in High Pressure Oxy-Coal Combustion Systems

Reaction Engineering International (REI) has managed a team of experts from the University of Utah, Southeast University (SEU) in Nanjing, China, Electric Power Research Institute (EPRI), Corrosion Management Ltd. (C-M), Praxair, and Brigham Young University (BYU) to investigate dry pulverized coal feeding for pressurized oxy-coal combustion. Dry feed firing systems for entrained flow, pressurized, oxy-coal combustors have not been well developed, although related technologies have been used in the Shell Gasification Process and for pressurized fluid bed combustion. DOE-funded research recently completed at REI and the University of Utah focused on characterizing impacts of high temperatures and pressures in oxy-coal combustion systems. For high pressure combustion, that research used a coal slurry feed into a 17 bar pressurized combustor. As a consequence of that research, it was identified that fuel feeding and firing system flexibility are challenges that require attention. Based on that experience, the approach of using a coal slurry feed system leads to challenges in producing consistent atomization of the slurry, which causes burnout problems, especially at high pressures. In addition, slurry atomization processes may be difficult to scale to sizes appropriate for practical commercial use. Dry pressurized coal burner systems, on the other hand, have the potential to yield efficiency gains, improve flexibility and facilitate applications at larger scales. Experimental work was conducted at the University of Utah Industrial Combustion and Gasification Research Facility as well as the 100 kW pressurized oxy-coal combustor (POC) facility at Brigham Young University. Mechanism development and CFD-based combustion and dense-phase flow modeling were performed at REI. Successful completion of the project objectives has resulted in the following key deliverables: 1) Design and prototype of a pressurized pulverized coal feeding and oxy-firing system 2) Data from a 100kW, pressurized (15 bar) entrained flow reactor with a dry feeding delivery and burner system that describes flame characteristics, radiative heat flux profiles, carbon burnout, along with characteristics of ash aerosols, fouling, and slagging. 3) Validated and transportable models that describe the relevant conditions in pressurized oxy-combustion systems and that can be used for scale-up and optimization. 4) Principles to guide design of high pressure, pilot-scale and full-scale coal oxy-firing systems. 5) Assessment of pressurized oxy-combustion impacts on key parameters relevant to oxy-coal fired utility boilers such as coal devolatilization, char oxidation, mineral matter transformation, deposition, and corrosion. The experimental data, pressurized oxy-firing system principles, and process mechanisms provided by this work can be used by electric utilities, boiler OEMs, equipment suppliers, design firms, software vendors, consultants and government agencies to assess the use of high temperature and high pressure oxy-combustion in current research and to guide development of new oxy-coal boiler designs.

pressurized oxy-coal combustion, sub-micron ash ae↗

Discussion on the merits of deep borehole disposal, especially with recycling - 15389

With the continued global expansion of the nuclear industry, disposal of spent nuclear fuel (SNF) and high level waste (HLW) continues to be a largely unimplemented (but extensively studied) activity throughout the world and can continue to do so due to the safe practices of 'interim' SNF/used nuclear fuel (UNF) and HLW storage. However as the industry continues to operate and expand in both existing and new countries, the accumulated SNF/UNF and HLW will continue to grow in both quantity and locations across the globe; hence, requiring more effort to control and monitor. Countries with nuclear power programs, or are considering starting nuclear power programs, must consider the potential financial and the engineering burden associated with both the interim storage and the disposal of SNF/UNF and HLW produced by these programs: can the cost of disposal be reasonably captured in the cost of electricity produced from nuclear programs and are there suitable sites for disposal in their country, such as a mined-geologic site, for the expected accumulated quantity of SNF and HLW? Answering these questions may be particularly vexing for countries with small nuclear programs where establishing viable disposal sites for SNF and HLW and funding of the development of these sites may be a challenge. In an effort to establish an alternative to traditional, expensive, mined-geologic disposal sites, the deep borehole option has been (re-)considered by multiple countries and entities to be a relatively simple solution to disposal of SNF and HLW. However, disposal of SNF in deep boreholes must overcome several issues including: (1) limiting-sized borehole diameters; (2) limited ability for retrieval; and (3) potential hang-up issues associated with lowering longer (e.g., > 180 inches) canisters down into a deep borehole. Since most SNF is a resource when recycled (i.e., UNF) and to dispose of it in an irretrievable manner would be wasteful, a more optimal alternative that could overcome these issues and maximize the benefits of the UNF is to recycle the UNF and dispose of the resulting HLW into deep boreholes. The multiple and mutual benefits of this approach are elucidated in this paper. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Controlling distributed energy resources via deep reinforcement learning for load flexibility and energy efficiency

Behind-the-meter distributed energy resources (DERs), including building solar photovoltaic (PV) technology and electric battery storage, are increasingly being considered as solutions to support carbon reduction goals and increase grid reliability and resiliency. However, dynamic control of these resources in concert with traditional building loads, to effect efficiency and demand flexibility, is not yet commonplace in commercial control products. Traditional rule-based control algorithms do not offer integrated closed-loop control to optimize across systems, and most often, PV and battery systems are operated for energy arbitrage and demand charge management, and not for the provision of grid services. More advanced control approaches, such as MPC control have not been widely adopted in industry because they require significant expertise to develop and deploy. Recent advances in deep reinforcement learning (DRL) offer a promising option to optimize the operation of DER systems and building loads with reduced setup effort. However, there are limited studies that evaluate the efficacy of these methods to control multiple building subsystems simultaneously. Additionally, most of the research has been conducted in simulated environments as opposed to real buildings. This paper proposes a DRL approach that uses a deep deterministic policy gradient algorithm for integrated control of HVAC and electric battery storage systems in the presence of on-site PV generation. The DRL algorithm, trained on synthetic data, was deployed in a physical test building and evaluated against a baseline that uses the current best-in-class rule-based control strategies. Performance in delivering energy efficiency, load shift, and load shed was tested using price-based signals. The results showed that the DRL-based controller can produce cost savings of up to 39.6% as compared to the baseline controller, while maintaining similar thermal comfort in the building. The project team has also integrated the simulation components developed during this work as an OpenAIGym environment and made it publicly available so that prospective DRL researchers can leverage this environment to evaluate alternate DRL algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fit for Purpose Remote Technology Decommissioning Solutions - 18630

The Magnox Decommissioning Project is actively progressing clean-up and decommissioning of 12 reactor sites across England, Scotland and Wales. Funded and directed by the United Kingdom's Nuclear Decommissioning Authority (NDA) and managed by the Cavendish Fluor Partnership (CFP), the Magnox Decommissioning Project introduces a wide range of radiological and industrial hazards warranting deployment of remote technologies to safely de-inventory, decontaminate and decommission a vast array of nuclear facilities. The Magnox Decommissioning Project encompasses 22 former Magnox nuclear power production reactors across 10 reactor sites and five research/test reactors at two former research sites. Decommissioning activities have been underway at some sites for nearly 20 years with early focus on retrieving and stabilising wastes and draining and stabilising spent fuel ponds. The Magnox decommissioning strategy invokes a programme perspective to drive consistency in tackling similar decommissioning and waste challenges across multiple sites. Programme central teams have worked with technology suppliers to foster learning from industry experience to develop and deploy tooling and robotics. The programme approach has also facilitated learning from one site to the next. In many cases, this central programme approach has promoted an evolution of technologies resulting in optimisation of simple remote tooling. In other instances, collaboration with suppliers is producing state-of-the-art technologies to tackle more unique challenges including, most recently, early demonstration of laser cutting for reactor vessel dismantling. This paper will outline the programme management approach and the scalable optioneering process Magnox employs to select the engineered controls and technologies used in decommissioning and waste management activities. It will provide an overview of the broad range of remote tooling and robotics deployed across the 12 Magnox sites by exploring some specific examples. Lastly, the paper will summarise key lessons learned in the now extensive history of selecting and using remote technologies to decommission Magnox nuclear facilities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Brush/Fin Thermal Interfaces

Brush/fin thermal interfaces are being developed to increase heat-transfer efficiency and thereby enhance the thermal management of orbital replaceable units (ORUs) of electronic and other equipment aboard the International Space Station. Brush/fin thermal interfaces could also be used to increase heat-transfer efficiency in terrestrial electronic and power systems. In a typical application according to conventional practice, a replaceable heat-generating unit includes a mounting surface with black-anodized metal fins that mesh with the matching fins of a heat sink or radiator on which the unit is mounted. The fins do not contact each other, but transfer heat via radiation exchange. A brush/fin interface also includes intermeshing fins, the difference being that the gaps between the fins are filled with brushes made of carbon or other fibers. The fibers span the gap between intermeshed fins, allowing heat transfer by conduction through the fibers. The fibers are attached to the metal surfaces as velvet-like coats in the manner of the carbon fiber brush heat exchangers described in the preceding article. The fiber brushes provide both mechanical compliance and thermal contact, thereby ensuring low contact thermal resistance. A certain amount of force is required to intermesh the fins due to sliding friction of the brush s fiber tips against the fins. This force increases linearly with penetration distance, reaching ~1 psi (~6.9 kPa) for full 2-in. (5.1 cm) penetration for the conventional radiant fin interface. Removal forces can be greater due to fiber buckling upon reversing the sliding direction. This buckling force can be greatly reduced by biasing the fibers at an angle perpendicularly to the sliding direction. Means of containing potentially harmful carbon fiber debris, which is electrically conductive, have been developed. Small prototype brush/fin thermal interfaces have been tested and found to exhibit temperature drops about onesixth of that of conventional meshing-fin thermal interface, when fabricated as a retrofit. In this case, conduction through the long, thin metal fins themselves becomes a thermal bottleneck. Further improvement could be made by prescribing aluminum fins to be shorter and thicker than those of the conventional meshing-fin thermal interfaces; the choice of height and thickness would be optimized to obtain greater overall thermal conductance, lower weight, and lower cost.

Knowles, Timothy R.↗

GPS-Based Gamma Survey for Characterizing and Decommissioning NORM Sites - 20389

Gamma survey techniques are an especially powerful decommissioning tool at naturally occurring radioactive material (NORM) sites due to both the low cost to obtain data over a large spatial scale and the abundance of gamma emitters in the uranium and thorium decay series. Gamma surveys are executed by coupling a detector - most often a sodium iodide crystal - to a global positioning system (GPS), then reporting a location and gross gamma reading coincidentally to a data logger. Systems may be carried by workers or mounted to a car, all-terrain vehicle, or unmanned aerial system (UAS). The resulting data set provides a high-resolution but low precision map of the gamma radiation field over the area surveyed. Frequently this map is also correlated to soil concentrations of NORM radionuclides (most often, Ra-226) and/or exposure rate. Gamma survey parameters such as movement speed, transect spacing, and data logging frequency define the spatial resolution of the resulting surface, and can be optimized depending on the desired survey sensitivity. This paper examines gamma survey as a tool for decommissioning NORM sites and provides an overview of current gamma survey technology designed to improve the efficiency and effectiveness of the decommissioning process. Topics to be discussed in the paper include: - An overview of gamma survey systems, and the utility of different delivery vehicles depending on desired cost, desired spatial resolution, and site topography. - The influence of physical detector characteristics on detection sensitivity and survey planning. - The tradeoff between high-resolution and large spatial extent, but inherently uncertain data, and low-resolution, low spatial extent, but highly certain data, as well as the specific utility of each of these types of data during NORM facility decommissioning. - Confounding variables that may limit the utility of gamma survey at some sites (e.g., radon gas and spatial heterogeneity / hot spots), and methods to plan for and control these conditions. Results show that the confounding variables, such as radon and data output can greatly influence the overall data quality associated with the decommissioning process. In addition, the use of real-time and aerial survey platforms provides a method for ensuring proper spatial extent of the data. When applied thoughtfully, gamma survey is a powerful tool for detecting NORM radionuclides in the environment and a cost-effective technique for identifying areas requiring remediation. However, entities performing or using gamma survey as a decommissioning tool must be aware of both its advantages and its limitations before basing remediation or regulatory action on gamma survey results. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

HTMT-class Latency Tolerant Parallel Architecture for Petaflops Scale Computation

Computational Aero Sciences and other numeric intensive computation disciplines demand computing throughputs substantially greater than the Teraflops scale systems only now becoming available. The related fields of fluids, structures, thermal, combustion, and dynamic controls are among the interdisciplinary areas that in combination with sufficient resolution and advanced adaptive techniques may force performance requirements towards Petaflops. This will be especially true for compute intensive models such as Navier-Stokes are or when such system models are only part of a larger design optimization computation involving many design points. Yet recent experience with conventional MPP configurations comprising commodity processing and memory components has shown that larger scale frequently results in higher programming difficulty and lower system efficiency. While important advances in system software and algorithms techniques have had some impact on efficiency and programmability for certain classes of problems, in general it is unlikely that software alone will resolve the challenges to higher scalability. As in the past, future generations of high-end computers may require a combination of hardware architecture and system software advances to enable efficient operation at a Petaflops level. The NASA led HTMT project has engaged the talents of a broad interdisciplinary team to develop a new strategy in high-end system architecture to deliver petaflops scale computing in the 2004/5 timeframe. The Hybrid-Technology, MultiThreaded parallel computer architecture incorporates several advanced technologies in combination with an innovative dynamic adaptive scheduling mechanism to provide unprecedented performance and efficiency within practical constraints of cost, complexity, and power consumption. The emerging superconductor Rapid Single Flux Quantum electronics can operate at 100 GHz (the record is 770 GHz) and one percent of the power required by convention semiconductor logic. Wave Division Multiplexing optical communications can approach a peak per fiber bandwidth of 1 Tbps and the new Data Vortex network topology employing this technology can connect tens of thousands of ports providing a bi-section bandwidth on the order of a Petabyte per second with latencies well below 100 nanoseconds, even under heavy loads. Processor-in-Memory (PIM) technology combines logic and memory on the same chip exposing the internal bandwidth of the memory row buffers at low latency. And holographic storage photorefractive storage technologies provide high-density memory with access a thousand times faster than conventional disk technologies. Together these technologies enable a new class of shared memory system architecture with a peak performance in the range of a Petaflops but size and power requirements comparable to today's largest Teraflops scale systems. To achieve high-sustained performance, HTMT combines an advanced multithreading processor architecture with a memory-driven coarse-grained latency management strategy called "percolation", yielding high efficiency while reducing the much of the parallel programming burden. This paper will present the basic system architecture characteristics made possible through this series of advanced technologies and then give a detailed description of the new percolation approach to runtime latency management.

Sterling, Thomas↗

Software development infrastructure for the HYBRID modeling and simulation project

One of the goals of the HYBRID modeling and simulation project is to assess the economic viability of hybrid systems in a market that contains renewable energy sources like wind. The idea is that it is possible for the nuclear plant to sell non-electric energy cushions, which absorb (at least partially) the volatility introduced by the renewable energy sources. This system is currently modeled in the Modelica programming language. To assess the economics of the system, an optimization procedure is trying to find the minimal cost of electricity production. The RAVEN code is used as a driver for the whole problem. It is assumed that at this stage, the HYBRID modeling and simulation framework can be classified as non-safety “research and development” software. The associated quality level is Quality Level 3 software. This imposes low requirements on quality control, testing and documentation. The quality level could change as the application development continues.Despite the low quality requirement level, a workflow for the HYBRID developers has been defined that include a coding standard and some documentation and testing requirements. The repository performs automated unit testing of contributed models. The automated testing is achieved via an open-source python script called BuildingsP from Lawrence Berkeley National Lab. BuildingsPy runs Modelica simulation tests using Dymola in an automated manner and generates and runs unit tests from Modelica scripts written by developers. In order to assure effective communication between the different national laboratories a biweekly videoconference has been set-up, where developers can report their progress and issues. In addition, periodic face-face meetings are organized intended to discuss high-level strategy decisions with management. A second means of communication is the developer email list. This is a list to which everybody can send emails that will be received by the collective of the developers and managers involved in the project. Thirdly, to exchange documents quickly, a SharePoint directory has been set-up. SharePoint allows teams and organizations to intelligently share, and collaborate on content from anywhere.

97 MATHEMATICS AND COMPUTING↗

The Effect of the Presence of Ozone on the Lower Flammability Limit (LFL) of Hydrogen in Vessels Containing Savannah River Site High Level Waste - 12387

The Enhanced Chemical Cleaning (ECC) process uses ozone to effect the oxidation of metal oxalates produced during the dissolution of sludge in the Savannah River Site (SRS) waste tanks. The ozone reacts with the metal oxalates to form metal oxide and hydroxide precipitants, and the CO{sub 2}, O{sub 2}, H{sub 2}O and any unreacted O{sub 3} gases are discharged into the vapor space. In addition to the non-radioactive metals in the waste, however, the SRS radioactive waste also contains a variety of radionuclides, hence, hydrogen gas is also present in the vapor space of the ECC system. Because hydrogen is flammable, the impact of this resultant gas stream on the Lower Flammability Limit (LFL) of hydrogen must be understood for all possible operating scenarios of both normal and off-normal situations, with particular emphasis at the elevated temperatures and pressures of the typical ECC operating conditions. Oxygen is a known accelerant in combustion reactions, but while there are data associated with the behavior of hydrogen/oxygen environments, recent, relevant studies addressing the effect of ozone on the flammability limit of hydrogen proved scarce. Further, discussions with industry experts verified the absence of data in this area and indicated that laboratory testing, specific to defined operating parameters, was needed to comprehensively address the issue. Testing was thus designed and commissioned to provide the data necessary to support safety related considerations for the ECC process. A test matrix was developed to envelope the bounding conditions considered credible during ECC processing. Each test consists of combining a gas stream of high purity hydrogen with a gas stream comprised of a specified mixture of ozone and oxygen in a temperature and pressure regulated chamber such that the relative compositions of the two streams are controlled. The gases are then stirred to obtain a homogeneous mixture and ignition attempted by applying 10J of energy to a fuse wire. A gas combination is considered flammable when a pressure rise of 7% of the initial absolute pressure is observed. The specified testing methodology is consistent with guidelines established in ASTM E-918-83 (2005) 'Standard Practices for Determining Limits of Flammability of Chemicals at Elevated Temperature and Pressure'. The LFL of hydrogen in air was determined and is in good agreement with the literature data. Ozone-oxygen mixtures were found to be flammable at concentrations above 8.3 vol.% based on the ASTM E918 7% pressure rise criteria for flame propagation. This result is lower than previously reported values which can be explained through the variations in the test setup and procedure. It is believed that the lower values obtained in this work are a result of improvements of the test methodology. Tests performed with hydrogen in various concentrations of ozone in oxygen have shown that the LFL of hydrogen decreases as the concentration of ozone in the mixture increases. This testing was designed to provide data under the conditions considered most optimal to produce deflagration. The geometry and materials of construction of the testing vessel; the location of the fuse wire; the magnitude of the supplied energy; the careful minimization of diluents and other contaminants; and meticulous procedural detail to maintain integrity of the ozone to the maximum extent practical, result in data that reflect not the expected process conditions, but those that enhance the possibility of flame propagation. For this reason, there is believed to be considerable conservatism in the indicated results. Per the vendor, the maximum possible ozone concentration producible by the planned ECC Ozone generator is 8 volume percent (the typical maximum operating setpoint concentration is 6.8 vol%), less than the 8.3 minimum volume % concentration shown to be flammable in a 99.999% pure O{sub 2} environment at the optimally conservative conditions established in this testing. Further, the feed to the ECC ozone generator is only 87% oxygen, the remainder, water vapor and nitrogen, both powerful diluents. It is, thus, believed not credible that deflagration can occur at this maximum feed concentration condition. In addition, once the ozone stream contacts the waste stream, the many simultaneous oxidizing reactions will rapidly decompose available ozone to well below flammable levels. Further, because the radiolytically generated hydrogen quantity is negligible compared to the supplied ozone/oxygen stream (0.0004 moles per minute H{sub 2} vs 76 moles per minute ozone/oxygen), even the total H{sub 2}/O{sub 3} mixture, without crediting decomposition reactions, does not approach flammable concentrations. Finally, even at the 'end' of the ECC batch cycle, when most of the metal oxalates have been decomposed, testing has indicated that the ozone concentration in the vapor space of the ECC process vessel reaches a concentration of no more than 3 vol%, remaining well below concentrations of concern. The major issue for the ECC operation established by this testing is the impact of the data when applied to off normal conditions. While it is possible to discontinue ozone addition to the reaction vessel at any time, the radiolytic hydrogen generation rate continues, varying slightly as ambient pressures and temperatures change. Relative to the data generated and analyzed in this testing, the ECC hazards analysis team will re-evaluate off normal conditions (e.g. those during which process exhaust ventilation is lost) such that issues involving mixtures of hydrogen and ozone in the vapor space can be appropriately controlled. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CONTROL TESTING OF THE UK NATIONAL NUCLEAR LABORATORY'S RADBALL TECHNOLOGY AT SAVANNAH RIVER NATIONAL LABORATORY

The UK National Nuclear Laboratory (NNL) has developed a remote, non-electrical, radiation-mapping device known as RadBall (patent pending), which offers a means to locate and quantify radiation hazards and sources within contaminated areas of the nuclear industry. To date, the RadBall has been deployed in a number of technology trials in nuclear waste reprocessing plants at Sellafield in the UK. The trials have demonstrated the successful ability of the RadBall technology to be deployed and retrieved from active areas. The positive results from these initial deployment trials and the anticipated future potential of RadBall have led to the NNL partnering with the Savannah River National Laboratory (SRNL) to further underpin and strengthen the technical performance of the technology. RadBall consists of a colander-like outer shell that houses a radiation-sensitive polymer sphere. It has no power requirements and can be positioned in tight or hard-to reach places. The outer shell works to collimate radiation sources and those areas of the polymer sphere that are exposed react, becoming increasingly less transparent, in proportion to the absorbed dose. The polymer sphere is imaged in an optical-CT scanner which produces a high resolution 3D map of optical attenuation coefficients. Subsequent analysis of the optical attenuation maps provides information on the spatial distribution and strength of the sources in a given area forming a 3D characterization of the area of interest. This study completed at SRNL addresses key aspects of the testing of the RadBall technology. The first set of tests was performed at Savannah River Nuclear Solutions Health Physics Instrument Calibration Laboratory (HPICL) using various gamma-ray sources and an x-ray machine with known radiological characteristics. The objective of these preliminary tests was to identify the optimal dose and collimator thickness. The second set of tests involved a highly contaminated hot cell. The objective of this part of the testing was to characterize a hot cell with unknown radiation sources. The RadBall calibration experiments and hot cell deployment completed at SRNL were successful in that for each trial, the technology was able to locate the radiation sources. The NNL believe that the ability of RadBall to be remotely deployed with no electrical supplies into difficult to access areas of plant and locate and quantify radiation hazards is a unique radiation mapping service. The NNL consider there to be significant business potential associated with this innovative technology.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reducing Cost of Chlorinated Volatile Organic Compound Remediation by Transitioning from Active to Passive Soil Vapor Extraction - 20157

Areas of high chlorinated volatile organic compound (cVOC) contamination at the Savannah River Site (SRS) have been undergoing remediation via soil vapor extraction, sometimes coupled with thermal treatments to enhance extraction rates. These active systems are effective in removing large amounts of contaminant mass from the subsurface and mitigating the impacts to groundwater. However, as extraction rates decline, costs must be evaluated with respect to the benefit of continued active operation. A decision framework for identifying conditions when a transition to a more passive remediation is appropriate has been developed with state and federal regulatory agencies. Two remediation areas have recently been transitioned from active soil vapor extraction (ASVE) to passive soil vapor extraction (PSVE) at the SRS. Performance evaluation goals including plume stabilization, overall mass removal trends, environmental sustainability and costs were considered in transitioning from active remediation to passive technologies at both sites. At the Dynamic Underground Stripping (DUS) project at the M-Area Settling Basin, ASVE was combined with steam injection to extract cVOCs during active operations. Steam injection occurred from September 2005 to September 2009. DUS utilized 63 steam injection wells, 34 active vapor extraction wells, and 3 active soil vapor extraction units (SVEUs). Two active SVEUs had 60 horsepower blowers; the third had a 25-horsepower blower. Mass removal was closely tracked during DUS operations; over 181,437 kilograms (400,000 pounds) of cVOCs were removed while active steam injection occurred. After steaming was stopped, ASVE continued. The 34 active wells were evaluated in 2012. The ASVE wells were grouped into categories of high, medium, and low extraction rates. High producing wells remained connected to a single active SVEU. Low producing wells were abandoned, and the medium producing wells were transitioned to PSVE (Microblowers{sup TM}). Microblowers{sup TM} utilize a dedicated blower per well and are solar powered. This passive technology provides energy, maintenance, and operation costs savings while still providing an efficient reduction in cVOC migration to groundwater. In 2018, the remaining ASVE wells were evaluated again. The purpose of this testing was to identify which wells removed the most mass. An optimal well configuration was determined. The criteria to discontinue ASVE was removal of less than 18 kilograms (40 pounds) per week of cVOCs. After 3 months of shutdown (rebound conditions), 2.7 kilograms (5.9 pounds) of cVOCs per week were being removed. Data from the rebound test justified ending ASVE and transitioning wells with higher extraction rates to PSVE. Wells that had depleted the cVOC mass within their zone of influence were abandoned. Performance data from existing PSVE wells justified ending PSVE at wells with depleted extraction rates. Currently the system has 16 PSVE wells operating. Another ASVE system was being used to treat cVOC contaminated soil at the A-Area Miscellaneous Rubble Pile (AMRP) at SRS. System operation began in 2004, with 7 ASVE wells connected to a 60- horsepower blower. Mass removal rates and contaminant concentrations remained consistently low over the ASVE lifespan at AMRP. This indicated that mass removal was diffusion limited. With this data, the 7 ASVE wells were transitioned to PSVE in 2017. Twelve pressure monitoring points were also transitioned to PSVE wells. AMRP currently has 19 PSVE wells operating. Both transitions from active to passive remediation had concurrence from the United States Environmental Protection Agency and the South Carolina Department of Health and Environmental Control. These transitions ensure that only the necessary amount of energy is being exerted to remediate the environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Compact Linac for Proton Therapy Based on a Dielectric Wall Accelerator

A novel compact CT-guided intensity modulated proton radiotherapy (IMPT) system is described. The system is being designed to deliver fast IMPT so that larger target volumes and motion management can be accomplished. The system will be ideal for large and complex target volumes in young patients. The basis of the design is the dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL). The DWA uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system will produce individual pulses that can be varied in intensity, energy and spot width. The IMPT planning system will optimize delivery characteristics. The system will be capable of being sited in a conventional linac vault and provide intensity modulated rotational therapy. Feasibility tests of an optimization system for selecting the position, energy, intensity and spot size for a collection of spots comprising the treatment are underway. A prototype is being designed and concept designs of the envelope and environmental needs of the unit are beginning. The status of the developmental new technologies that make the compact system possible will be reviewed. These include, high gradient vacuum insulators, solid dielectric materials, SiC photoconductive switches and compact proton sources.

43 PARTICLE ACCELERATORS↗

Study on Gaseous and Liquid Radioactive Effluents in AP1000 Plants

During normal operation, the gaseous and liquid radioactive effluents will be released in nuclear plants. It is the base of effluents management and environment influence evaluation to analyze the anticipated annual activity releases. In China, both the annual release of radioactive liquid and gaseous effluents limit value (for single plant and whole-site) and the liquid concentration of discharge canal are introduced in GB6249-2011. This standard is mandatory and the limit values must be met. Because the limit values are very strict, it is meaningful to determine a suitable and logical method of liquid and gaseous effluents in China. In this paper, according to the operation actuality and related rules of law in China, the analysis method of nuclides except H-3 and C-14 in the gaseous and liquid effluents of AP1000 plant is introduced. The method and results can be reference for effluents analysis for AP1000 plants. According to the revised method, the gaseous and liquid radioactive effluents for Sanmen 1 and 2 plants are calculated. The results and the comparison with the limit value in GB6249-2011 are given. The liquid concentration of discharge canal is 868.4 Bq/l, which is less than the limit value 1000 Bq/L in GB6249-2011. It can be seen that according to the revised method, the gaseous and liquid radioactive effluents for Sanmen 1 and 2 plants can meet the limit value in GB6249-2011. This revised method considers all the source, the detailed purification process and release pathways for gaseous and liquid radioactive effluents. The effluents calculation in the revised method can be a possible reference to the analysis of the gaseous and liquid radioactive effluents in China, though there may be some detailed optimization and improvement in future. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Agent-Based Coordination Scheme for PV Integration (ABC4PV)

Renewables and especially photovoltaics (PV) have benefitted significantly from a host of incentives and policies targeted toward enhanced integration and adoption of specific energy technologies. However, with the push to move forward into a subsidy-free market framework, behind-the-meter residential PV applications have generally struggled to retain their value (unlike utility scale and commercial projects) [1]. This project focused on developing control-theoretic solutions aimed at improving the integration and interaction of behind-the-meter residential PV with other distribution system assets (controllable and non-controllable) to enhance the integrated value of residential PV. To this end, a suite of decentralized control methodologies have been developed to enable effective coordination and control of behind-the-meter residential load customers’ PV, battery storage systems (BSS), controllable loads and other similar assets within a distribution feeder. This interaction aims at procuring energy savings and, thus, energy bill savings. The main source of savings is drawn from reducing the effect of demand charge pricing and is realized at the feeder level, assuming community level interaction and management among the aforementioned assets. Optimal control of the assets is implemented with a distributed optimization methodology, leveraging consensus-based algorithms. The results gathered from the optimal control simulations demonstrates that the savings can be duly achieved and the algorithm decision times (to dynamically control asset set points, for example) are fast. As for the overall efficiency of PV+BSS systems, to procure energy savings from curtailment of the demand charge pricing effects, the optimal control is set up so as to minimize the variance of the load for all customers, throughout a feeder and throughout time in a rolling horizon scheduling with model predictive control. The control takes into account inter-temporal electrochemical storage (battery) degradation costs: specifically, we have developed a long-term lifetime model for the BSS that weighs in the effect of the degradation factor in the dispatch formulations, thus, a considerable operating cost that affects energy decision making. The levelized cost of energy (LCOE – redefined for the purpose of quantifying asset integration effectiveness through the customers’ energy cost) is shown to be below the threshold set for the combined PV+BSS topology of $ 0.14/kWh for multiple cases of PV penetration all the way up to 50%, provided that a policy of shared ownership of and savings is in place. Further, the LCOE calculated for the case before the deployment PV+BSS systems is also achievable, i.e. the deployment of PV+BSS, if planned and scheduled optimally. will have no effect on customers’ energy costs. From the control methodology viewpoint, the developed consensus-based algorithms are shown to converge for a wide range of problem cases (spanning normal operating scenarios and contingencies), guaranteeing dispatch solutions under forecasting errors, communication break-downs and cyber-security attacks. The proposed control solutions are scalable and real-time implementable, with dispatch computations and device set-point updates converging in less than 2s in most practical instances of the above events.

14 SOLAR ENERGY↗