Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Broadband Characterization and Circuit Model Development of Transmission-Scale Transformers

This report describes broadband measurements of transmission-scale transformers typical in the electric power grid. This work was performed as part of the EMP Resilient Grid LDRD project at Sandia National Laboratories to generate circuit models that can be used for high-altitude electromagnetic pulse (HEMP) coupling simulations and response predictions. The objective of the work was to obtain characterization data of substation yard equipment across a frequency range relevant to HEMP. Vector network analyzer measurements up to 100 MHz were performed on two power transformers at ABB-Hitachi and a single ITEC potential transformer. Custom cable breakouts were designed to interface with the transformer terminals and provide ground connections to the chassis at the base of the transformer bushings. The three-phase terminals of the power transformers were measured as a common mode impedance using a parallel resistive splitter, and the single-phase terminals of the potential transformer were measured directly. A vector fitting algorithm was used to empirically fit circuit models to the resulting two-port networks and input impedances of the measured objects. Simplified circuit representations of the input impedances were also generated to assess the degree of precision needed for high-altitude electromagnetic pulse response predictions, which were performed in Sandia's XYCE circuit simulator platform. HEMP coupling simulations using the transformer models showed significant reduction in the voltage peak and broadening in the pulse width seen at the power transformer compared to the traveling wave voltage. This indicated the importance of the load condition when defining the coupled insult in an electric power substation. Simplified circuit models showed a similar voltage at the transformer with a smoothed waveform. The presence of potential transformers in the simulation did not significantly change the simulated voltage at the power transformer. Single-port input impedance models were also developed to define load conditions when transfer characteristics were not necessary.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Short-Term Frequency Response of a DFIG-Based Wind Turbine Generator for Rapid Frequency Stabilization

This paper proposes a short-term frequency-response scheme of a doubly-fed induction generator (DFIG)-based wind turbine generator (WTG) for improving rotor speed recovery and frequency nadir. In the energy-releasing period, to improve the frequency nadir and rotor speed convergence by releasing a large amount of kinetic energy stored in the rotating masses in a DFIG-based WTG, the power reference is increased up to the torque limit referred to the power and reduces along with it for a predefined period which is determined based on the occurrence time of the frequency nadir in a power grid. Then, the reference decreases so that the rotor speed is forced to be converged to the preset value in the stable operating region of the rotor speed. In the energy-absorbing period, to quickly recover the rotor speed, the reference smoothly decreases with the rotor speed and time during a predefined period until it intersects with the maximum power point tracking curve. The simulation results demonstrate that the proposed scheme successfully achieves rapid frequency stabilization with the improved frequency nadir under various wind conditions based on the IEEE 14-bus system.

17 WIND ENERGY↗

A Near-Real-Time Model for Predicting Electricity Disruptions in Texas During Winter Storms

There has been an increase in extreme weather events, posing a threat to power grid systems, potentially influenced by factors such as population growth, changes in ecosystems, land cover, and land use in the service area, as well as the growth of certain vegetation types. This research seeks to develop a predictive model to mitigate potential damages caused by future winter storms. This research utilizes the Light Gradient Boosting Machine (LightGBM), incorporating the number of power outages experienced at the county level, geographic details, weather information, and lagged outage and lagged weather data. The developed models were broadly divided into two groups, with six models in each group - one group without optimization and another with optimization, totaling 12 trained models. For model optimization, Bayesian optimization was employed using Root Mean Squared Error (RMSE) as the objective function. In results, when comparing Group 2 (the optimized group) with Group 1 (the non-optimized group), it was found that optimization did not always lead to a reduction in RMSE and Mean Absolute Error (MAE). However, in terms of Mean Directional Accuracy (MDA), while all results in Group 1 were below the baseline accuracy of 0.33, all results in Group 2 exceeded 0.33, with some cases showing an increase of more than three times the baseline. The results indicated that, in the optimized model group, Population and Pressure were the most influential factors when using current weather data and geographical information. When using lagged data, lagged recorded outages and lagged Pressure emerged as the most significant factors. Among the 12 developed models, the L-1-2-O model showed the lowest RMSE and MAE, as well as the highest accuracy, with values of 390.62 households and 168.13 households, respectively. To normalize the RMSE and MAE values, each metric was divided by the average number of households among the counties in Texas. For the L-1-2-O model, the scaled RMSE was 0.88% and the scaled MAE was 0.38%. In terms of MDA, which indicates the accuracy of the prediction direction, the L-1-O model achieved the highest score of 0.41. Although this study focused on Texas, which suffered the greatest impact from the winter storms in 2021, with additional validation, the methodology used in this research could be applied to other regions.

Lee, Jangjae [Texas A & M Univ., College Station, ↗

Time Synchronization Techniques in the Modern Smart Grid: A Comprehensive Survey

In modern smart grids, accurate and synchronized time signals are essential for effective monitoring, protection, and control. Various time synchronization methods exist, each tailored to specific application needs. Widely adopted solutions, such as GPS, however, are vulnerable to challenges such as signal loss and cyber-attacks, underscoring the need for reliable backup or supplementary solutions. This paper examines the timing requirements across different power grid applications and provides a comprehensive review of available time synchronization mechanisms. Through a comparative analysis of timing methods based on accuracy, flexibility, reliability, and security, this study offers insights to guide the selection of optimal solutions for seamless grid integration.

comparison↗

Energy Beam Highways Through the Skies

The emergence of Energy Beam Flight Transportation Systems could dramatically change the way we travel in the 21st Century. A framework for formulating 'Highways of Light' and the top level architectures that invoke radically new Space Power Grid infrastructure, are introduced. Basically, such flight systems, hereafter called Lightcraft, would employ off-board energy beam sources (either laser or microwave) to energize on-board dependent 'motors' -- instead of the traditional autonomous 'engines' with their on-board energy sources (e.g., chemical fuels). Extreme reductions in vehicle dry mass appear feasible with the use of off-board power and a high degree of on-board artificial intelligence. Such vehicles may no longer need airports for refueling (since they require no propellant), and could possibly pick up travelers at their homes -- before motoring over to one of many local boost stations, for the flight out. With off-board power, hyper-energetic acceleration performance and boost-glide trajectories become feasible. Hypersonic MS airbreathing propulsion can enable boosts up to twice escape velocity, which will cut trip times to the moon down to 5.5 hours. The predominant technological, environmental and social factors that will result from such transportation systems will be stressed. This presentation first introduces the remote source siting options for the space power system infrastructure, and then provides three representative laser/microwave Lightcraft options (derived from historical Case Studies): i.e., 'Acorn', 'Toy Top', and 'Disc.' Next the gamut of combined-cycle engine options developed for these Lightcraft are examined -- to illuminate the 'emerging technologies' that must be harnessed to produce flight hardware. Needed proof-of concept experiments are identified, along with the Macro-Level Issues that can springboard these revolutionary concepts into hardware reality.

Myrabo, Leik N.↗

Use of Traveling Wave Signatures in Medium-Voltage Distribution Systems for Fault Detection and Location

Protection systems are a critical feature for the proper operation of a power grid. Protection systems should be able to quickly detect, identify, locate, and isolate the faults within a time frame that prevents damage to grid components and reduces customer outages. As more inverter-based photovoltaics (PV) are integrated into the grid, phasor domain based protection schemes become more inaccurate due to low levels of fault current from inverters or respond too slowly to accurately identify fault conditions. This points to the need to identify and develop novel protection approaches for distribution systems with high penetration of inverter based PV. The main objective of the project is to develop new time domain-based protection schemes to enable more accurate and faster detection, identification and location of faults in distribution systems and/or microgrids with high penetration of inverter-based PV. Our approach aims to exploit the traveling waves that are generated during a fault or other disturbances in the grid.

14 SOLAR ENERGY↗

Scaled Implementation of Smart Charge Management for Electric Vehicles

Smart charge management (SCM) has become a critical strategy for mitigating potential grid impacts and reducing electricity costs for all customers. This study will evaluate the economics of implementing light-duty EV SCM at scale across the United States. This work will enhance distribution system analysis by estimating SCM implementation costs, exploring viable business cases, and developing a framework for national-level applications. The primary methodology involves leveraging detailed grid modeling from a specific service territory and using spatial extrapolation techniques to generalize findings to other regions. The analysis will develop key metrics to quantify the costs and benefits of SCM, including implementation costs relative to strategy and scale, the cost of distribution system upgrades with and without SCM, and the percentage of peak-load reduction. The objective is to produce a comprehensive report and a parameterized framework that enables utilities to self-assess the value of SCM in their own service territories. This will support the development of cost-effective charging strategies, accelerate the energization of new EV chargers, and facilitate the seamless integration of EVs into the nation's power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-economic analysis of the impact of dynamic electricity prices on solar penetration in a smart grid environment with distributed energy storage

This study investigates the technical and economic feasibility of using high levels of solar energy penetration up to 400 MW into a smart grid system of 60,000 smart houses. A novel non-cooperative Stackelberg game is introduced that incorporates the profitability of the supply-side and helps in solving problems related to overgeneration and photovoltaic curtailment. The non-cooperative game is intended to find the optimal dynamic prices that would leverage distributed storage through the demand-side to stabilize the power grid operation. Ten cases are studied with five photovoltaic plant sizes and two battery designs. Here, a novel quantitative analysis of high levels of solar penetration as a percentage of the total electricity demand is introduced to evaluate the technical feasibility of the studied cases. To evaluate the economic viability of the proposed smart grid system, four metrics were used: the levelized cost of energy, the levelized cost of storage, the payback period, and the net present value. Two out of ten studied cases were concluded to be the most promising cases, one with a solar photovoltaic plant size of 200 MW and the other with 300 MW. The case with 300 MW solar plant is preferred as it paves the way for more solar energy deployment with a solar penetration percentage up to 67.78%. This case had a payback period of 10.72 years and a net present value of $\$51.44$ M for the solar plant and a payback period of 12.06 years and a net present value of $\$40.75$ M for the demand-side.

14 SOLAR ENERGY↗

Overview of simulation and control tools for extended operability of nuclear reactors - 183

The increasing penetration of Renewable Energy Sources (RES) requires the current power grid to be suitably improved. Because of the unsteady nature of RES, as long as energy storage facilities are not deployed and commercialized, an increased effort for the frequency regulation in order to ensure high reliability and performance is necessary. In such a scenario, nuclear units (traditionally deployed as baseload generating units) will be required to cooperate with intermittent RES-based power plants. Therefore, new reactors will need larger operational flexibility with respect to the capabilities of the currently operated units. Over the last few years, a comprehensive research program oriented at developing a suite of simulation tools and control system development capabilities was pursued at Argonne National Laboratory. In addition to the study of advanced reactor concepts (e.g. metal-fueled Sodium-cooled Fast Reactors) and technological innovations (such as S-CO{sub 2} Energy Conversion Cycles), new control approaches were developed to improve the operability of nuclear power plants. In particular, Model-based Predictive Control algorithm for Multiple Input Multiple Output control strategies and set-point definition algorithm based on Reference Governor were studied and applied to specific scenarios, providing with a range of novel capabilities able to meet the expected greater sets of requirements mentioned above. In this work, an overview of such tools and case studies is presented with particular focus on their impact on operability and economic competitiveness of nuclear energy. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced Measurements for Resilient Integration of Inverter-Based Resources: PROGRESS MATRIX Year-1 Report

As nearly every aspect of the electric power grid undergoes rapid change, measurement technologies that support grid operation and planning must evolve as well. Recent large-scale deployments of inverter-based resources (IBRs) have brought to the forefront the critical need for new measurement technologies. Though these IBRs are vital to achieving the nation’s clean energy goals, their rapid deployment has in some cases led to negative impacts on the reliability and security of the bulk power system (BPS). Advanced power system measurements, including synchronized phasor and waveform measurements, are key to making IBR integration secure and reliable. To this end, the Department of Energy (DOE) initiated a project in 2022 to develop advanced measurement capabilities and analytics that will accelerate adoption of IBRs while improving the reliability and resilience of the BPS. This report discusses a portion of the findings from the project’s first year, which focused on surveying existing measurement capabilities of partner utilities and comparing these capabilities with the requirements of applications that support IBR integration. This report also discusses how these findings will guide the development and demonstration of a set of applications in the project’s second year.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A comparison study on trading behavior and profit distribution in local energy transaction games

With the increasing integration of distributed energy resources, localized peer-to-peer energy transactions are receiving more attention since they could absorb more distributed renewables locally and stabilize the power grid. To better study the trading behavior and provide guidance for a viable local market design, different game-theoretical frameworks including cooperative and non-cooperative games are established and compared here. For the cooperative grand coalition, the maximum social welfare is guaranteed, the Shapley value and bargaining based approaches are implemented for further profit redistribution. It is shown that the asymmetrical bargaining power can be critical in the final payment clearing and it is equivalent to the Shapley value allocation if prosumers bargain based on their marginal contributions. Non-cooperative trading is formulated by using a Stackelberg bilevel model in which the upper level has the privilege in internal price setting. However, system optimum is not obtained due to competition, and the selfish leader could take away 89% of the collective benefit by price-gap based arbitraging. Aiming for a long-lasting trading market, a virtual benevolent leader and a uniform price structure in which purchase price equals selling price are tested. Experimental results indicate that maximum social welfare and a fairer profit allocation can be achieved with a uniform price structure, regardless of the selfish or benevolent attitude.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Feasibility Analysis for the Use of Retrofitted Air-Conditioners Using Thermal Energy Storage (TES) for High Ambient Temperature (HAT) Countries

In high ambient temperature (HAT) countries, summer temperatures exceed 35℃, degrading the performance of air-conditioning systems and straining power grids. In this paper, a feasibility analysis was conducted to investigate potential savings during the peak using latent Thermal Energy Storage (TES) at near room phase-change temperatures, replacing condensers, thus, minimizing temperature lifts. Weather data, building loads, and baseline air-conditioning systems data were gathered for Dubai. A transient vapor-compression model in Modelica was used to compare the COP, total power input and cooling capacity of the air-conditioner at peak hours when ambient temperatures range between 35 – 45 ⁰C versus the TES-Phase-Change Material (PCM) melting temperatures from 22 – 28⁰C. The results indicate that the TES-PCM can enhance the system COP at the peak by a factor 1.4 and 2 for during for outdoor temperatures of 35 – 40⁰C, and 40 – 45⁰C, respectively. Lower melting temperature PCMs were able to reduce the required power input by 30-50%, with more savings occurring at higher temperature days. On the other hand, higher temperature PCMs enhancements were minimal especially at outdoor ambient temperatures ranging between 35 – 40⁰C. Improvements to the cooling capacity range from 8 – 18 % for the outdoor temperature range of 35 – 45 ⁰C. An economic analysis was conducted to find the potential saving in utility costs for 30%, 60%, and 90% of the space cooling demands of Dubai, and find the trade-off points between utility savings and cost of PCM-TES implementation. If the peak loads are to be shifted by 6 hours daily, the percentage utility savings for the city is 18%. Using estimated costs of the PCM-TES, ranging from $200-500/kWh, the daily load shifting hours were estimated to range from 4 hours at the lowest cost systems to 2.5 hours at the highest costs.

25 ENERGY STORAGE↗

The Final Proceedings of the DOE/NASA Solar Power Satellite Program Review

The solar power satellite (SPS) concept defined as 'placing gigantic satellites in geosynchronous orbit to capture sunlight, changing the energy into an appropriate form for transmission to Earth, and introducing the energy into the electric power grid' is evaluated in terms of costs and benefits. The concept development and evaluation program is reviewed in four general areas: systems definition; environmental; societal; and comparative assessments. Specific factors addressed include: transportation, construction in space, methods of conversion of sunlight into energy, transmission to Earth, maintenance in orbit and decommissioning of satellites; environmental, political, and economic effects; and comparison of SPS to other forms of power generation, both terrestrial and in space.

Source record↗

Assessment of the Phase-to-Ground Fault Apparent Admittance Method with Phase/Ground Boundaries to Detect Types of Electrical Faults for Protective Relays Using Signature Library and Simulated Events

Protective relays in electric power grids recognize the types of electrical faults in a few seconds. The most common detection method to detect the types of electrical faults is based on measuring the angle between the zero and negative sequence currents. However, it is not completely accurate because the phase to phase ground and phase to ground electrical faults could have the same detection conditions. Therefore, engineers need to plot the events after an electrical fault to observe the nature of the incidents in detail. In this study, the phase to ground fault apparent (PGFA) admittance method with phase/ground boundaries identified the types of electrical faults located in distribution power lines and feeders. This method was based on measuring the PGFA admittance magnitudes for the faulted and non-faulted phases, resulting in greater than zero and near zero, respectively. The PGFA admittance algorithm was built with MATLAB/ Simulink software and tested with signature library and grid simulation events. The PGFA method with phase/ground boundaries was evaluated with the confusion matrix. The measured and predicted values matched in more than 90% of the tests, and the PGFA admittance method with phase/ground boundaries presented an accuracy of 94.3% and a precision of 100%.

Piesciorovsky, Emilio↗

Robustness Against Disturbances in Power Systems Under Frequency Constraints

The wide deployment of renewable generation and the gradual decrease in the overall system inertia make modern power grids more vulnerable to transient instabilities and unacceptable frequency fluctuations. Time-domain simulation based assessment of the system robustness against uncertain and stochastic disturbances is extremely time-consuming. In this paper, we develop an alternative approach, which has its roots in the input-output stability analysis for Lur'e systems. Our approach consists of a mathematically rigorous characterization of the external disturbances that the power system is transiently stable and the frequency constraints are not violated. As a result, the derived certificate is efficiently constructed via convex optimization and is shown to be non-conservative for different IEEE test cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inertial Response of Wind Power Plants: A Comparison of Frequency-Based Inertial Control and Stepwise Inertial Control

The frequency regulation capability of a wind power plant plays an important role in enhancing frequency reliability especially in an isolated power system with high wind power penetration levels. A comparison of two types of inertial control methods, namely frequency-based inertial control (FBIC) and stepwise inertial control (SIC), is presented in this paper. Comprehensive case studies are carried out to reveal features of the different inertial control methods, simulated in a modified Western System Coordination Council (WSCC) nine-bus power grid using real-time digital simulator (RTDS) platform. The simulation results provide an insight into the inertial control methods under various scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Systems Approach to Analyzing Cyber-Physical Threats in the Smart Grid

This paper presents a systems analysis approach to characterizing the risk of a Smart Grid to a load-drop attack. A characterization of the risk is necessary for the design of detection and remediation strategies to address the consequences of such attacks. Using concepts from systems health management and system engineering, this work (a) first identifies metrics that can be used to generate constraints for security features, and (b) lays out an end-to-end integrated methodology using separate network and power simulations to assess system risk. We demonstrate our approach by performing a systems-style analysis of a load-drop attack implemented over the AMI subsystem and targeted at destabilizing the underlying power grid.

Almajali, Anas↗