Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PROFITS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Modeling charging infrastructure impact on the electric vehicle market in China

The plug-in electric vehicle (PEV) is deemed as a critical technological revolution, and the governments are imposing various vehicle policies to promote its development. Meanwhile, the market success of PEVs depends on many aspects. The study reported herein integrates one’s use of charging infrastructure at home, public place and workplace into the market dynamics analysis tool, New Energy and Oil Consumption Credits (NEOCC) model, to systematically assess the charging infrastructure (home parking ratio, public charging opportunity, and charging costs) impact on PEV ownership costs and analyze how the PEV market shares may be affected by the attributes of the charging infrastructure. Compared to the charging infrastructure, the impact of battery costs is incontrovertibly decisive on PEV market shares, the charging infrastructure is still non-negligible in the PEV market dynamics. The simulation results find that the public charging infrastructure has more effectiveness on promoting the PEV sales in the PEV emerging market than it does in the PEV mature market. However, the improvement of charging infrastructure does not necessarily lead to a larger PEV market if the charging infrastructure incentives do not coordinate well with other PEV policies. Besides, the increase of public charging opportunities has limited motivations on the growth of public PEV fleets, which are highly correlated to the number of public fast charging stations or outlets. It also finds that more home parking spaces can stimulate more sales of personal plug-in hybrid electric vehicles instead of personal battery electric vehicles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrodeposited Silver Nanoparticles Patterned Hexagonally for SERS

We have fabricated hexagonally patterned silver nanoparticles for surface-enhanced Raman scattering (SERS) by electrodepositing silver on the surface of an aluminum plate prepared by completely removing the oxide from anodic aluminum oxide (AAO) templates. Even after completely removing the oxide, well-ordered hexagonal patterns, similar to the shape of graphene, remained on the surface of the aluminum plate. The borders of the hexagonal pattern protruded up to form sorts of nano-mountains at both the sides and apexes of the hexagon, with the apexes protruding even more significantly than the sides. The aluminum plate prepared by completely removing the oxide has been used in the preparation of SERS substrates by sputter-coating of gold or silver on it. Instead of sputter-coating, here we have electro-deposited silver on the aluminum plate. When silver was electro-deposited on the plate, silver nanoparticles were made along the hexagonal margins.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Stomatal Parameters in a Changing Environment

Here, we recommend that stomatal slope parameters (g 1 ) be inferred by inversion so that variations in g 1 may be attributed to variations physiological and environmental conditions. Understanding g1 will advance predictions of plant gas exchange and performance under global climate.

Stomatal conductance modeling↗

Correlation and prediction uncertainties in the CyberKnife Synchrony respiratory tracking system

Purpose: The CyberKnife uses an online prediction model to improve radiation delivery when treating lung tumors. This study evaluates the prediction model used by the CyberKnife radiation therapy system in terms of treatment margins about the gross tumor volume (GTV). Methods: From the data log files produced by the CyberKnife synchrony model, the uncertainty in radiation delivery can be calculated. Modeler points indicate the tracked position of the tumor and Predictor points predict the position about 115 ms in the future. The discrepancy between Predictor points and their corresponding Modeler points was analyzed for 100 treatment model data sets from 23 de-identified lung patients. The treatment margins were determined in each anatomic direction to cover an arbitrary volume of the GTV, derived from the Modeler points, when the radiation is targeted at the Predictor points. Each treatment model had about 30 min of motion data, of which about 10 min constituted treatment time; only these 10 min were used in the analysis. The frequencies of margin sizes were analyzed and truncated Gaussian normal functions were fit to each direction's distribution. The standard deviation of each Gaussian distribution was then used to describe the necessary margin expansions in each signed dimension in order to achieve the desired coverage. In this study, 95% modeler point coverage was compared to 99% modeler coverage. Two other error sources were investigated: the correlation error and the targeting error. These were added to the prediction error to give an aggregate error for the CyberKnife during treatment of lung tumors. Results: Considering the magnitude of 2{sigma} from the mean of the Gaussian in each signed dimension, the margin expansions needed for 95% modeler point coverage were 1.2 mm in the lateral (LAT) direction and 1.7 mm in the anterior-posterior (AP) direction. For the superior-inferior (SI) direction, the fit was poor; but empirically, the expansions were 3.5 mm. For 99% modeler point coverage, the AP margin was 3.6 mm and the lateral margin was 2.9 mm. The SI margins for 99% modeler point coverage were highly variable. The aggregate error at 95% was 6.9 mm in the SI direction, 4.6 mm in the AP direction, and 3.5 in the lateral direction. Conclusions: The Predictor points follow the Modeler points closely. Margins were found in each clinical direction that would provide 95% modeler point coverage for 95% of the models reviewed in this study. Similar margins were found in two clinical directions for 99% modeler point coverage in 95% of models. These results can offer guidance in the selection of CTV margins for treatment with the CyberKnife.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-30: Benchmark Image-Based TCP Calculation for Evaluation of PTV Margins for Lung SBRT Patients

Purpose: Tumor control probability (TCP) calculated with accumulated radiation doses may help design appropriate treatment margins. Image registration errors, however, may compromise the calculated TCP. The purpose of this study is to develop benchmark CT images to quantify registration-induced errors in the accumulated doses and their corresponding TCP. Methods: 4DCT images were registered from end-inhale (EI) to end-exhale (EE) using a “demons” algorithm. The demons DVFs were corrected by an FEM model to get realistic deformation fields. The FEM DVFs were used to warp the EI images to create the FEM-simulated images. The two images combined with the FEM DVF formed a benchmark model. Maximum intensity projection (MIP) images, created from the EI and simulated images, were used to develop IMRT plans. Two plans with 3 and 5 mm margins were developed for each patient. With these plans, radiation doses were recalculated on the simulated images and warped back to the EI images using the FEM DVFs to get the accumulated doses. The Elastix software was used to register the FEM-simulated images to the EI images. TCPs calculated with the Elastix-accumulated doses were compared with those generated by the FEM to get the TCP error of the Elastix registrations. Results: For six lung patients, the mean Elastix registration error ranged from 0.93 to 1.98 mm. Their relative dose errors in PTV were between 0.28% and 6.8% for 3mm margin plans, and between 0.29% and 6.3% for 5mm-margin plans. As the PTV margin reduced from 5 to 3 mm, the mean TCP error of the Elastix-reconstructed doses increased from 2.0% to 2.9%, and the mean NTCP errors decreased from 1.2% to 1.1%. Conclusion: Patient-specific benchmark images can be used to evaluate the impact of registration errors on the computed TCPs, and may help select appropriate PTV margins for lung SBRT patients.

60 APPLIED LIFE SCIENCES↗

SU-E-J-39: Comparison of PTV Margins Determined by In-Room Stereoscopic Image Guidance and by On-Board Cone Beam Computed Tomography Technique for Brain Radiotherapy Patients

Purpose: Stereoscopic in room kV image guidance is a faster tool in daily monitoring of patient positioning. Our centre, for the first time in the world, has integrated such a solution from BrainLAB (ExacTrac) with Elekta's volumetric cone beam computed tomography (XVI). Using van Herk's formula, we compared the planning target volume (PTV) margins calculated by both these systems for patients treated with brain radiotherapy. Methods: For a total of 24 patients who received partial or whole brain radiotherapy, verification images were acquired for 524 treatment sessions by XVI and for 334 sessions by ExacTrac out of the total 547 sessions. Systematic and random errors were calculated in cranio-caudal, lateral and antero-posterior directions for both techniques. PTV margins were then determined using van Herk formula. Results: In the cranio-caudal direction, systematic error, random error and the calculated PTV margin were found to be 0.13 cm, 0.12 cm and 0.41 cm with XVI and 0.14 cm, 0.13 cm and 0.44 cm with ExacTrac. The corresponding values in lateral direction were 0.13 cm 0.1 cm and 0.4 cm with XVI and 0.13 cm, 0.12 cm and 0.42 cm with ExacTrac imaging. The same parameters for antero-posterior were for 0.1 cm, 0.11 cm and 0.34 cm with XVI and 0.13 cm, 0.16 cm and 0.43 cm with ExacTrac imaging. The margins estimated with the two imaging modalities were comparable within ± 1 mm limit. Conclusion: Verification of setup errors in the major axes by two independent imaging systems showed the results are comparable and within ± 1 mm. This implies that planar imaging based ExacTrac can yield equal accuracy in setup error determination as the time consuming volumetric imaging which is considered as the gold standard. Accordingly PTV margins estimated by this faster imaging technique can be confidently used in clinical setup.

60 APPLIED LIFE SCIENCES↗

SU-E-J-124: FDG PET Metrics Analysis in the Context of An Adaptive PET Protocol for Node Positive Gynecologic Cancer Patients

Purpose: To compare PET extracted metrics and investigate the role of a gradient-based PET segmentation tool, PET Edge (MIM Software Inc., Cleveland, OH), in the context of an adaptive PET protocol for node positive gynecologic cancer patients. Methods: An IRB approved protocol enrolled women with gynecological, PET visible malignancies. A PET-CT was obtained for treatment planning prescribed to 45–50.4Gy with a 55– 70Gy boost to the PET positive nodes. An intra-treatment PET-CT was obtained between 30–36Gy, and all volumes re-contoured. Standard uptake values (SUVmax, SUVmean, SUVmedian) and GTV volumes were extracted from the clinician contoured GTVs on the pre- and intra-treament PET-CT for primaries and nodes and compared with a two tailed Wilcoxon signed-rank test. The differences between primary and node GTV volumes contoured in the treatment planning system and those volumes generated using PET Edge were also investigated. Bland-Altman plots were used to describe significant differences between the two contouring methods. Results: Thirteen women were enrolled in this study. The median baseline/intra-treatment primary (SUVmax, mean, median) were (30.5, 9.09, 7.83)/( 16.6, 4.35, 3.74), and nodes were (20.1, 4.64, 3.93)/( 6.78, 3.13, 3.26). The p values were all < 0.001. The clinical contours were all larger than the PET Edge generated ones, with mean difference of +20.6 ml for primary, and +23.5 ml for nodes. The Bland-Altman revealed changes between clinician/PET Edge contours to be mostly within the margins of the coefficient of variability. However, there was a proportional trend, i.e. the larger the GTV, the larger the clinical contours as compared to PET Edge contours. Conclusion: Primary and node SUV values taken from the intratreament PET-CT can be used to assess the disease response and to design an adaptive plan. The PET Edge tool can streamline the contouring process and lead to smaller, less user-dependent contours.

60 APPLIED LIFE SCIENCES↗

SU-E-J-267: Weekly Volumetric and Dosimetric Changes in Adaptive Conformal Radiotherapy of Non-Small-Cell-Lung Cancer Using 4D CT and Gating

Purpose: This study was to evaluate the significance of weekly imageguided patient setup and to assess the volumetric and dosimetric changes in no-small-cell-lung cancer (NSCLC) patients treated with adaptive conformal radiotherapy (CRT). Methods: 9 NSCLC patients treated with 3D CRT underwent 4D CT-on-rail every five fractions. ITV was generated from three phases of the 4DCT (the end of exhalation, 25% before and after the end of exhalation). The margin of ITV to PTV is 5mm. 6 weekly CTs were acquired for each patient. The weekly CTs were fused with the planning CT by vertebrae. The couch shift was recorded for each weekly CT to evaluate the setup error. The gross tumor volumes (GTVs) were contoured on weekly CT images by a physician. Beams from the original plans were applied to weekly CTs to calculate the delivered doses. All patients underwent replanning after 20 fractions. Results: Among the total 54 CTs, the average setup error was 2.0± 1.7, 2.6± 2.1, 2.7± 2.2 mm in X, Y, and Z direction, respectively. The average volume of the primary GTV was reduced from 42.45 cc to 22.78 cc (47.04%) after 6 weeks. The maximal volume regression occurred between 15 and 20 fractions. Adaptive radiation therapy (ART) reduced the V20 and V5 of the lung by 33.5% and 16.89%, respectively. ART also reduced Dmean and D1/3 of the heart by 31.7% and 32.32%, respectively. Dmax of the spinal cord did not vary much during the treatment course. Conclusion: 5 mm margin is sufficient for 4D weekly CTguided radiotherapy in lung cancer. Tumor regression was observed in the majority of patients. ART significantly reduced the OARs dose. Our preliminary results indicated that an off-line ART approach is appropriate in clinical practice.

60 APPLIED LIFE SCIENCES↗

End-to-end test of spatial accuracy in Gamma Knife treatments for trigeminal neuralgia

Purpose: Spatial accuracy is most crucial when small targets like the trigeminal nerve are treated. Although current quality assurance procedures typically verify that individual apparatus, like the MRI scanner, CT scanner, Gamma Knife, etc., are meeting specifications, the cumulative error of all equipment and procedures combined may exceed safe margins. This study uses an end-to-end approach to assess the overall targeting errors that may have occurred in individual patients previously treated for trigeminal neuralgia. Methods: The trigeminal nerve is simulated by a 3 mm long, 3.175 mm (1/8 in.) diameter MRI-contrast filled cavity embedded within a PMMA plastic capsule. The capsule is positioned within the head frame such that the location of the cavity matches the Gamma Knife coordinates of an arbitrarily chosen, previously treated patient. Gafchromic EBT2 film is placed at the center of the cavity in coronal and sagittal orientations. The films are marked with a pinprick to identify the cavity center. Treatments are planned for radiation delivery with 4 mm collimators according to MRI and CT scans using the clinical localizer boxes and acquisition protocols. Shots are planned so that the 50% isodose surface encompasses the cavity. Following irradiation, the films are scanned and analyzed. Targeting errors are defined as the distance between the pinprick, which represents the intended target, and the centroid of the 50% isodose line, which is the center of the radiation field that was actually delivered. Results: Averaged over ten patient simulations, targeting errors along the x, y, and z coordinates (patient’s left-to-right, posterior-to-anterior, and head-to-foot) were, respectively, −0.060 ± 0.363, −0.350 ± 0.253, and 0.348 ± 0.204 mm when MRI was used for treatment planning. Planning according to CT exhibited generally smaller errors, namely, 0.109 ± 0.167, −0.191 ± 0.144, and 0.211 ± 0.094 mm. The largest errors along individual axes in MRI- and CT-planned treatments were, respectively, −0.761 mm in the y-direction and 0.428 mm in the x-direction, well within safe limits. Conclusions: The highly accurate dose delivery was possible because the Gamma Knife, MRI scanner, and other equipment performed within tight limits and scans were acquired using the thinnest slices and smallest pixel sizes available. Had the individual devices performed only near the limits of their specifications, the cumulative error could have left parts of the trigeminal nerve undertreated. The presented end-to-end test gives assurance that patients had received the expected high quality treatment. End-to-end tests should become part of clinical practice.

60 APPLIED LIFE SCIENCES↗

SU-F-T-497: Spatiotemporally Optimal, Personalized Prescription Scheme for Glioblastoma Patients Using the Proliferation and Invasion Glioma Model

Purpose: To investigate a spatiotemporally optimal radiotherapy prescription scheme and its potential benefit for glioblastoma (GBM) patients using the proliferation and invasion (PI) glioma model. Methods: Standard prescription for GBM was assumed to deliver 46Gy in 23 fractions to GTV1+2cm margin and additional 14Gy in 7 fractions to GTV2+2cm margin. We simulated the tumor proliferation and invasion in 2D according to the PI glioma model with a moving velocity of 0.029(slow-move), 0.079(average-move), and 0.13(fast-move) mm/day for GTV2 with a radius of 1 and 2cm. For each tumor, the margin around GTV1 and GTV2 was varied to 0–6 cm and 1–3 cm respectively. Total dose to GTV1 was constrained such that the equivalent uniform dose (EUD) to normal brain equals EUD with the standard prescription. A non-stationary dose policy, where the fractional dose varies, was investigated to estimate the temporal effect of the radiation dose. The efficacy of an optimal prescription scheme was evaluated by tumor cell-surviving fraction (SF), EUD, and the expected survival time. Results: Optimal prescription for the slow-move tumors was to use 3.0(small)-3.5(large) cm margins to GTV1, and 1.5cm margin to GTV2. For the average- and fast-move tumors, it was optimal to use 6.0cm margin for GTV1 suggesting that whole brain therapy is optimal, and then 1.5cm (average-move) and 1.5–3.0cm (fast-move, small-large) margins for GTV2. It was optimal to deliver the boost sequentially using a linearly decreasing fractional dose for all tumors. Optimal prescription led to 0.001–0.465% of the tumor SF resulted from using the standard prescription, and increased tumor EUD by 25.3–49.3% and the estimated survival time by 7.6–22.2 months. Conclusion: It is feasible to optimize a prescription scheme depending on the individual tumor characteristics. A personalized prescription scheme could potentially increase tumor EUD and the expected survival time significantly without increasing EUD to normal brain.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-TeP2-04: Optimizing for a Specified Target Coverage Probability

Purpose: The purpose of this work is to develop a method for inverse planning of radiation therapy margins. When using this method the user specifies a desired target coverage probability and the system optimizes to meet the demand without any explicit specification of margins to handle setup uncertainty. Methods: The method determines which voxels to include in an optimization function promoting target coverage in order to achieve a specified target coverage probability. Voxels are selected in a way that retains the correlation between them: The target is displaced according to the setup errors and the voxels to include are selected as the union of the displaced target regions under the x% best scenarios according to some quality measure. The quality measure could depend on the dose to the considered structure alone or could depend on the dose to multiple structures in order to take into account correlation between structures. Results: A target coverage function was applied to the CTV of a prostate case with prescription 78 Gy and compared to conventional planning using a DVH function on the PTV. Planning was performed to achieve 90% probability of CTV coverage. The plan optimized using the coverage probability function had P(D98 > 77.95 Gy) = 0.97 for the CTV. The PTV plan using a constraint on minimum DVH 78 Gy at 90% had P(D98 > 77.95) = 0.44 for the CTV. To match the coverage probability optimization, the DVH volume parameter had to be increased to 97% which resulted in 0.5 Gy higher average dose to the rectum. Conclusion: Optimizing a target coverage probability is an easily used method to find a margin that achieves the desired coverage probability. It can lead to reduced OAR doses at the same coverage probability compared to planning with margins and DVH functions.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-JeP2-04: Deriving Delivered Doses to Assess the Viability of 2.5 Mm Margins in Head and Neck SBRT

Purpose: To calculate the delivered dose for head and neck SBRT patients using pre-treatment images. This delivered dose was then used to determine the viability of 2.5 mm margins. Methods: Daily cone beam CTs (CBCTs) were collected for 20 patients along with a planning CT, planned dose, and planning structures. The day 1 CBCT was aligned to the planning CT using the treatment shifts (six degrees of freedom) and then the dose and contours were transferred to the CBCT. The day 1 CBCT becomes the reference image for days 2–5. The day 2–5 CBCTs were also aligned to the planning CT using the treatment shifts given and the dose transferred. The day 2–5 CBCTs were then deformably registered to the day 1 CBCT. The doses delivered on days 2–5 were then deformed to the day 1 CBCT where they could be accumulated. This was achieved with MIM 6.5.1 (MIM Software, Cleveland OH). The accumulated doses for the 20 patients were evaluated against the planned doses using the initial planning criteria as points of comparison. Results: The delivered CTV dose conformed to the planned 98.6% coverage, with an average decrease of 2.6% between planned and delivered coverage. This implies the 2.5 mm margin was sufficient. Larger CTVs correlated to smaller differences between planned and delivered coverage. Delivered dose to critical structures including the spinal cord, mandible, brain, brainstem, and larynx was acceptable, with differences between planned and delivered max dose <5% on average. Similarly for the parotid glands, globes, cochlear, optic nerve, lens, and submandibular glands, differences between planned and delivered doses were generally <5%. Conclusion: The 2.5 mm margin provided acceptable CTV coverage, adequately accounting for setup errors. Organ at risk sparing was also satisfactory. Small tumor volumes (<20 cc) may require a larger margin to treat effectively.

60 APPLIED LIFE SCIENCES↗

WE-AB-209-08: Novel Beam-Specific Adaptive Margins for Reducing Organ-At-Risk Doses

Purpose: Current practice of using 3D margins in radiotherapy with high-energy photon beams provides larger-than-required target coverage. According to the photon depth-dose curve, target displacements in beam direction result in minute changes in dose delivered. We exploit this behavior by generating margins on a per-beam basis which simultaneously account for the relative distance of the target and adjacent organs-at-risk (OARs). Methods: For each beam, we consider only geometrical uncertainties of the target location perpendicular to beam direction. By weighting voxels based on its proximity to an OAR, we generate adaptive margins that yield similar overall target coverage probability and reduced OAR dose-burden, at the expense of increased target volume. Three IMRT plans, using 3D margins and 2D per-beam margins with and without adaptation, were generated for five prostate patients with a prescription dose Dpres of 78Gy in 2Gy fractions using identical optimisation constraints. Systematic uncertainties of 1.1, 1.1, 1.5mm in the LR, SI, and AP directions, respectively, and 0.9, 1.1, 1.0mm for the random uncertainties, were assumed. A verification tool was employed to simulate the effects of systematic and random errors using a population size of 50,000. The fraction of the population that satisfies or violates a given DVH constraint was used for comparison. Results: We observe similar target coverage across all plans, with at least 97.5% of the population meeting the D98%>95%Dpres constraint. When looking at the probability of the population receiving D5<70Gy for the rectum, we observed median absolute increases of 23.61% (range, 2.15%–27.85%) and 6.97% (range, 0.65%–17.76%) using per-beam margins with and without adaptation, respectively, relative to using 3D margins. Conclusion: We observed sufficient and similar target coverage using per-beam margins. By adapting each per-beam margin away from an OAR, we can further reduce OAR dose without significantly lowering target coverage probability by irradiating more less-important tissues. This work is supported by Cancer Research UK under Programme C33589/A19908. Research at ICR is also supported by Cancer Research UK under Programme C33589/A19727 and NHS funding to the NIHR Biomedical Research Centre at RMH and ICR.

07 ISOTOPE AND RADIATION SOURCES↗

TH-CD-202-11: Implications for Online Adaptive and Non-Adaptive Radiotherapy of Gastic and Gastroesophageal Junction Cancers Using MRI-Guided Radiotherapy

Purpose: Radiotherapy for gastric and gastroesophageal junction (GEJ) tumors commonly requires large margins due to deformation, motion and variable changes of the stomach anatomy, at the risk of increased normal tissue toxicities. This work quantifies the interfraction variation of stomach deformation from daily MRI-guided radiotherapy to allow for a more targeted determination of margin expansion in the treatment of gastric and GEJ tumors. Methods: Five patients treated for gastric (n=3) and gastroesophageal junction (n=2) cancers with conventionally fractionated radiotherapy underwent daily MR imaging on a clinical MR-IGRT system. Treatment planning and contours were performed based on the MR simulation. The stomach was re-contoured on each daily volumetric setup MR. Dice similarity coefficients (DSC) of the daily stomach were computed to evaluate the stomach interfraction deformation. To evaluate the stomach margin, the maximum Hausdorff distance (HD) between the initial and fractional stomach surface was measured for each fraction. The margin expansion, needed to encompass all fractions, was evaluated from the union of all fractional stomachs. Results: In total, 94 fractions with daily stomach contours were evaluated. For the interfraction stomach differences, the average DSC was 0.67±0.1 for gastric and 0.62±0.1 for GEJ cases. The maximum HD of each fraction was 3.5±2.0cm (n=94) with mean HD of 0.8±0.4cm (across all surface voxels for all fractions). The margin expansion required to encompass all individual fractions (averaged across 5 patients) was 1.4 cm(superior), 2.3 cm(inferior), 2.5 cm(right), 3.2 cm(left), 3.7 cm(anterior), 3.4 cm(posterior). Maximum observed difference for margin expansion was 8.7cm(posterior) among one patient. Conclusion: We observed a notable interfractional change in daily stomach shape (i.e., mean DSC of 0.67, p<0.0001) in both gastric and GEJ patients, for which adaptive radiotherapy is indicated. A minimum PTV margin of 3 cm is indicated to account for interfraction stomach changes when adaptive radiotherapy is not available. M. Bassetti: Travel funding from ViewRay, Inc.

60 APPLIED LIFE SCIENCES↗

TH-CD-202-12: Online Inter-Beam Replanning Based On Real-Time Dose Reconstruction

Purpose: This work provides a proof-of-concept study for online replanning during treatment delivery for step-and-shoot prostate SBRT, based on real-time dose reconstruction. Online replanning is expected to improve the trade-off between target coverage and organ-at-risk dose in the presence of intra-fractional motion. Methods: We have implemented an online replanning workflow on top of our previously reported real-time dose reconstruction software which connects to an Elekta research linac. The treatment planning system DynaPlan was extended to (1) re-optimize and sequence treatment plans (in clockwise beam order) before each beam, based on actual delivered dose, in a timeframe limited by the gantry rotation between subsequent beams, and (2) send the respective segments to the delivery control software DynaTrack which starts/continues treatment immediately.To investigate the impact of a reduced safety margin, we have created and delivered (on a linac emulator) a conventional CTV+5/3mm (I) and a reduced CTV+1mm margin (II) treatment plan for a prostate patient. We have assessed CTV coverage with and without inter-beam replanning, all exposed to a gradual target shift of 0–5mm in posterior and inferior direction from start until the end of delivery. Results: For the reconstructed conventional plan (I), D98 for CTV was 100% of D98 of the planned dose. For the reconstructed margin-reduced plan (II), D98 for CTV was 95% of the planned D98 without replanning, but could be recovered to 99% by replanning for each beam. Plan (II) with replanning resulted in a decrease for bladder V90% by 88% and an increase to rectum V90% by 9% compared to the conventional plan (I). Dose calculation/accumulation was performed in <15ms per MLC aperture, replanning in <15s per beam. Conclusion: We have shown that online inter-beam replanning is technically feasible and potentially allows for a margin reduction. Future investigation considering motion-robust replanning optimization parameters is in progress. We acknowledge support of the MLC research from Elekta AB. This work is supported by Cancer Research UK under Programme C33589/A19908. Research at ICR is also supported by Cancer Research UK under Programme C33589/A19727 and NHS funding to the NIHR Biomedical Research Centre at RMH and ICR.

60 APPLIED LIFE SCIENCES↗

Data for Yield from Iowa’s first commercial miscanthus fields: implications of spatial variability for productivity and sustainability beyond research plots

This dataset contains biomass yield measurements and associated vegetation index data collected from commercial Miscanthus × giganteus fields in eastern Iowa during the 2022–2023 growing seasons. The data support the analyses presented in the article: “Yield From Iowa's First Commercial Miscanthus Fields: Implications of Spatial Variability for Productivity and Sustainability Beyond Research Plots.” We collected 105 ground-truth biomass samples from four mature commercial fields (>4 years old) covering 92.81 ha. Samples were taken from 3 m² quadrats that were hand-harvested in alignment with commercial harvest timing. Stem biomass (excluding leaves) was weighed, moisture-corrected, and converted to dry-matter yield expressed in Mg DM ha⁻¹. Sampling locations were selected to capture spatial variability visible in aerial imagery and were recorded using RTK GPS. Each biomass observation was paired with vegetation indices derived from high-resolution PlanetScope satellite imagery (3 m resolution). Images were acquired throughout the growing season, and indices were calculated to evaluate their ability to predict end-of-season biomass yield. Statistical and machine learning approaches were used to identify key predictors, and a linear regression model based on end-of-July Green Normalized Difference Vegetation Index (GNDVI) was developed and evaluated. This repository includes the data used in that modeling workflow. Management practices, economic data, full imagery time series, and additional methodological details are described in the associated publication and are not included here. The dataset consists of three comma-separated value (CSV) files: 1. Combine_Groundtruth_Yield_VI_22_23.csv This file contains ground-truth biomass yield measurements and associated key vegetation index values collected during the 2022 and 2023 growing seasons. Rows: 105 observations Columns: Year — Year of observation (2022 or 2023) Field — Field location identifier Sample_number — Unique sample identifier GNDVI_End_Jul — Green Normalized Difference Vegetation Index calculated at end of July GNDVI_End_Aug — Green Normalized Difference Vegetation Index calculated at end of August NDRE_End_Aug — Normalized Difference Red Edge index calculated at end of August Biomass_Stem_Yield_MgDM/ha — Measured stem biomass yield (megagrams dry matter per hectare) 2. trainData_GNDVI.csv This file contains the subset of observations used to train the predictive relationship between July GNDVI and biomass yield. Rows: 76 observations Columns: Unnamed: 0 — Row index retained from the original data processing workflow GNDVI_End_Jul — GNDVI at end of July Stem_Yield_MgDM/ha — Observed stem biomass yield (Mg DM ha⁻¹) 3. testData_GNDVI.csv This file contains the test dataset used to evaluate model performance. Rows: 29 observations Columns: Unnamed: 0 — Row index retained from the original data processing workflow GNDVI_End_Jul — GNDVI at end of July Predicted_Yield_MgDM/ha — Model-predicted stem biomass yield (Mg DM ha⁻¹) Observed_Yield_MgDM/ha — Measured stem biomass yield (Mg DM ha⁻¹)

Potential yield, yield gap, in-field management, y↗

Light Water Reactor Sustainability Program: Analysis of Pressurized Water Reactor Station Blackout Caused by External Flooding Using the RISMC Toolkit

The existing fleet of nuclear power plants is in the process of extending its lifetime and increasing the power generated from these plants via power uprates. In order to evaluate the impact of these factors on the safety of the plant, the Risk Informed Safety Margin Characterization (RISMC) project aims to provide insight to decision makers through a series of simulations of the plant dynamics for different initial conditions (e.g., probabilistic analysis and uncertainty quantification). This report focuses, in particular, on the application of a RISMC detailed demonstration case study for an emergent issue using the RAVEN and RELAP-7 tools. This case study looks at the impact of a couple of challenges to a hypothetical pressurized water reactor, including: (1) a power uprate, (2) a potential loss of off-site power followed by the possible loss of all diesel generators (i.e., a station black-out event), (3) and earthquake induces station-blackout, and (4) a potential earthquake induced tsunami flood. The analysis is performed by using a set of codes: a thermal-hydraulic code (RELAP-7), a flooding simulation tool (NEUTRINO) and a stochastic analysis tool (RAVEN) – these are currently under development at the Idaho National Laboratory.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗