Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLUGGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

RF-driven ion source with a back-streaming electron dump

A novel ion source is described having an improved lifetime. The ion source, in one embodiment, is a proton source, including an external RF antenna mounted to an RF window. To prevent backstreaming electrons formed in the beam column from striking the RF window, a back streaming electron dump is provided, which in one embodiment is formed of a cylindrical tube, open at one end to the ion source chamber and capped at its other end by a metal plug. The plug, maintained at the same electrical potential as the source, captures these backstreaming electrons, and thus prevents localized heating of the window, which due to said heating, might otherwise cause window damage.

47 OTHER INSTRUMENTATION↗

Actual Versus Estimated Utility Factor of a Large Set of Privately Owned Chevrolet Volts

In order to determine the overall fuel economy of a plug-in hybrid electric vehicle (PHEV), the amount of operation in charge depleting (CD) versus charge sustaining modes must be determined. Mode of operation is predominantly dependent on customer usage of the vehicle and is therefore highly variable. The utility factor (UF) concept was developed to quantify the distance a group of vehicles has traveled or may travel in CD mode. SAE J2841 presents a UF calculation method based on data collected from travel surveys of conventional vehicles. UF estimates have been used in a variety of areas, including the calculation of window sticker fuel economy, policy decisions, and vehicle design determination. The EV Project, a plug-in electric vehicle charging infrastructure demonstration being conducted across the United States, provides the opportunity to determine the real-world UF of a large group of privately owned Chevrolet Volt extended range electric vehicles. Using data collected from Volts enrolled in The EV Project, this paper compares the real-world UF of two groups of Chevrolet Volts to estimated UF's based on J2841. The actual observed fleet utility factors (FUF) for the MY2011/2012 and MY2013 Volt groups studied were observed to be 72% and 74%, respectively. Using the EPA CD ranges, the method prescribed by J2841 estimates a FUF of 65% and 68% for the MY2011/2012 and MY2013 Volt groups, respectively. Volt drivers achieved higher percentages of distance traveled in EV mode for two reasons. First, they had fewer long-distance travel days than drivers in the national travel survey referenced by J2841. Second, they charged more frequently than the J2841 assumption of once per day - drivers of Volts in this study averaged over 1.4 charging events per day. Although actual CD range varied widely as driving conditions varied, the average CD ranges for the two Volt groups studied matched the EPA CD range estimates, so CD range variation did not affect FUF results.

33 ADVANCED PROPULSION SYSTEMS↗

We Need to Talk... Developing Communicating Power Supplies to Monitor & Control Miscellaneous Electric Loads

Plug loads represent 30percent of total electricity use in residential buildings. Significant energy savings would result from an accurate understanding of which miscellaneous electric devices are using energy, at what time, and in what quantity. Commercially available plug load monitoring and control solutions replace or limit the attached device's native controls - forcing the user to adapt to a separate set of controls associated with the monitoring and control hardware. A better solution is integration of these capabilities at the power supply level. In this paper, we demonstrate a method achieving this integration. Our solution allows unobtrusive power monitoring and control while retaining native device control features. Further, our prototype enables intelligent behaviors by allowing devices to respond to the state of one another automatically. The CPS enables energy savings while demonstrating an added level of functionality to the user. If CPS technology became widespread in devices, a combination of automated and human interactive solutions would enable high levels of energy savings in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Interchangeable breech lock for glove boxes

A breech lock for a glove box is provided that may be used to transfer one or more items into the glove box. The breech lock can be interchangeably installed in place of a plug, glove, or other device in a port or opening of a glove box. Features are provided to aid the removal of items from the breech lock by a gloved operator. The breech lock can be reused or, if needed, can be replaced with a plug, glove, or other device at the port or opening of the glove box.

42 ENGINEERING↗

Saturated Monoglyceride Polymorphism and Gel Formation of Biodiesel Blends

Crystallization or gel formation of normal paraffins in diesel fuel under cold weather conditions leading to fuel filter clogging is a common problem. Cold weather operability of biodiesel (B100) and blends with diesel fuel presents additional complexity because of the presence of saturated monoglycerides (SMGs) and other relatively polar species. Currently, the cloud point measurement (a measure of when the first component crystallizes out of solution) is used to define the lowest temperature at which the fuel can be used without causing cold weather issues. While filter plugging issues have declined, there still remain intermittent unexpected problems above the cloud point for biodiesel blends. Development of a fundamental understanding of how minor components in biodiesel crystallize, gel, and transform is needed in order to prevent these unexpected issues. We have found that SMGs, a low level impurity present in B100 from the production process, can crystallize out of solution and undergo a solvent-mediated polymorphic phase transformation to a more stable, less soluble form. This causes them to persist at temperatures above the cloud point once they have some out of solution. Additionally, we have found that SMGs can cause other more soluble, lower melting point minor components in the B100 to co-crystallize and come out of solution. Monoolein, another minor component from the production process is an unsaturated monoglyceride with a much lower melting point and higher solubility than SMGs. It is able to form a co-crystal with the SMGs and is found together with the SMGs on plugged filters we have analyzed in our laboratory. An observation of isolated crystals in the lab led us to believe that the SMGs may also be forming a gel-like network with components of the B100 and diesel fuel. During filtration experiments, we have noted that in some cases a solid layer of crystals forms and blocks the filter completely, while in other cases this does not occur. Because SMGs are polar and can form layered networks once a sufficient amount of crystals have come out of solution, we recently began investigating the ability of SMGs to form a gel network with fuel components as well as with other minor polar components in the fuel in order to obtain a fundamental understanding of the mechanism of formation. It has been well established that this type of phenomena occurs in sub-sea pipelines where a chief crystallizing component begins to crystallize out of solution. Once a sufficient amount of crystals exists, a volume spanning network of solid crystals can trap liquid crude oil and form a solid-like gel network. We are investigating whether this type of phenomena can occur with SMGs and both fatty acid methyl esters from the B100 and normal paraffins from diesel fuel. Additionally, SMGs are well known to incorporate water into their layered crystal structure. Water is often used to stabilize less stable polymorphic forms of SMGs, therefore water was another minor component of interest. Also of interest is glycerin which has been found on clogged filters in our laboratory.

30 DIRECT ENERGY CONVERSION↗

Sustainable Federal Fleets: Deploying Electric Vehicles and Electric Vehicle Supply Equipment

The U.S. Department of Energy (DOE) Federal Energy Management Program (FEMP) helps federal agencies reduce petroleum consumption and increase alternative fuel use through its resources for Sustainable Federal Fleets. To assist agencies with the transition to plug-in electric vehicles (PEVs), including battery electric vehicles (BEVs) and plug-in hybrid electric vehicles (PHEVs), FEMP offers technical guidance on electric vehicle supply equipment (EVSE) installations and site-specific planning through partnerships with the National Renewable Energy Laboratory's (NREL's) EVSE Tiger Teams.

30 DIRECT ENERGY CONVERSION↗

Deploying Electric Vehicles and Electric Vehicle Supply Equipment: Tiger Teams Offer Project Assistance for Federal Fleets

To assist federal agencies with the transition to plug-in electric vehicles (PEVs), including battery electric vehicles (BEVs) and plug-in hybrid electric vehicles (PHEVs), FEMP offers technical guidance on electric vehicle supply equipment (EVSE) installations and site-specific planning through partnerships with the National Renewable Energy Laboratory’s EVSE Tiger Teams.

electric vehicle↗

SimApp 1.8.x

System for converting DESIRE (Direct Executing Simulation in Real Time) simulation models to executable code models (C# / C++). These converted models are used as the basis for 2 products, one of which is the focus of this review: an engineering design interface for Fissile Solution Systems. ModelConverter.exe (C#) converts DESIRE model inputs to a C++ plug-in subclass. SimApp.exe (C# / C++) has a C++ dll that is a numerical integration engine that the Converted models plug into. The engineering design interface is a C# GUI that calls on the C++ dll to execute a particular converted model. The GUI allows the user to specify the length of a simulation, run the simulation, view data plots and data tables. Stability plots may also be produced and manipulated. The engineering design interface will be released as source code and executable; the model converter source is also intended for release.

Determan, John C.↗

Building Energy Management Open Source Software

This is the repository for Building Energy Management Open Source Software (BEMOSS), which is an open source operating system that is engineered to improve sensing and control of equipment in small- and medium-sized commercial buildings. BEMOSS offers the following key features: (1) Open source, open architecture – BEMOSS is an open source operating system that is built upon VOLTTRON – a distributed agent platform developed by Pacific Northwest National Laboratory (PNNL). BEMOSS was designed to make it easy for hardware manufacturers to seamlessly interface their devices with BEMOSS. Software developers can also contribute to adding additional BEMOSS functionalities and applications. (2) Plug & play – BEMOSS was designed to automatically discover supported load controllers (including smart thermostats, VAV/RTUs, lighting load controllers and plug load controllers) in commercial buildings. (3) Interoperability – BEMOSS was designed to work with load control devices form different manufacturers that operate on different communication technologies and data exchange protocols. (4) Cost effectiveness – Implementation of BEMOSS deemed to be cost-effective as it was built upon a robust open source platform that can operate on a low-cost single-board computer, such as Odroid. This feature could contribute to its rapid deployment in small- or medium-sized commercial buildings. (5) Scalability and ease of deployment – With its multi-node architecture, BEMOSS provides a distributed architecture where load controllers in a multi-floor and high occupancy building could be monitored and controlled by multiple single-board computers hosting BEMOSS. This makes it possible for a building engineer to deploy BEMOSS in one zone of a building, be comfortable with its operation, and later on expand the deployment to the entire building to make it more energy efficient. (6) Ability to provide local and remote monitoring – BEMOSS provides both local and remote monitoring ability with role-based access control. (7) Security – In addition to built-in security features provided by VOLTTRON, BEMOSS provides enhanced security features, including BEMOSS discovery approval process, encrypted core-to-node communication, thermostat anti-tampering feature and many more. (8) Support from the Advisory Committee – BEMOSS was developed in consultation with an advisory committee from the beginning of the project. BEMOSS advisory committee comprises representatives from 22 organizations from government and industry.

Source record↗

Method for Hot Real-Time Sampling of Pyrolysis Vapors

Biomass Pyrolysis has been an increasing topic of research, in particular as a replacement for crude oil. This process utilizes moderate temperatures to thermally deconstruct the biomass which is then condensed into a mixture of liquid oxygenates to be used as fuel precursors. Pyrolysis oils contain more than 400 compounds, up to 60 percent of which do not re-volatilize for subsequent chemical analysis. Vapor chemical composition is also complicated as additional condensation reactions occur during the condensation and collection of the product. Due to the complexity of the pyrolysis oil, and a desire to catalytically upgrade the vapor composition before condensation, online real-time analytical techniques such as Molecular Beam Mass Spectrometry (MBMS) are of great use. However, in order to properly sample hot pyrolysis vapors, many challenges must be overcome. Sampling must occur within a narrow range of temperatures to reduce product composition changes from overheating or partial condensation or plugging of lines from condensed products. Residence times must be kept at a minimum to reduce further reaction chemistries. Pyrolysis vapors also form aerosols that are carried far downstream and can pass through filters resulting in build-up in downstream locations. The co-produced bio-char and ash from the pyrolysis process can lead to plugging of the sample lines, and must be filtered out at temperature, even with the use of cyclonic separators. A practical approach for considerations and sampling system design, as well as lessons learned are integrated into the hot analytical sampling system of the National Renewable Energy Laboratory's (NREL) Thermochemical Process Development Unit (TCPDU) to provide industrially relevant demonstrations of thermochemical transformations of biomass feedstocks at the pilot scale.

09 BIOMASS FUELS↗

Laser igniter with integral optimal geometry prechamber

A laser igniter that avoids autoignition and soot formation within the prechamber and will minimize the formation of Nitrogen Oxides (NO.sub.x). The laser igniter has a laser spark plug with a microlaser and a prechamber integrally formed with the laser spark plug. The prechamber has six nozzle holes with three of the nozzle holes having a large diameter and three of the nozzle holes having a small diameter. The large and small nozzle holes are in a staggered arrangement.

42 ENGINEERING↗

Transforming Wind Turbine Blade Mold Manufacturing with 3D Printing

Innovation in the design and manufacturing of wind power generation components continues to be critical. As a result of this challenge, DOE’s Wind Energy Technologies Office (WETO) and Advanced Manufacturing Office (AMO), both within EERE, are partnering with public and private organizations to apply additive manufacturing, commonly known as 3D printing, to the production of wind turbine blade molds. The traditional method of blade design requires the creation of a plug, or a full-size representation of the final blade, which is then used to make the mold. Creating the plug is one of the most time-intensive and labor-intensive processes in wind blade construction, saving time and money.

3D printing↗

Method and system to distribute high-energy pulses to multiple channels

A method and system to distribute high-power laser pulses to create sparks in individual cylinders of a multi-cylinder engine are provided. A laser provides laser output pulses. A distributor includes a linear array of mirrors with a respective mirror associated with one of the laser plugs. Each mirror is operatively controlled to move into a laser beam path to direct individual laser output pulses the associated laser plug for providing spark generation. The system enables correct cylinder firing order for predefined multi-cylinder firing sequences and allows for individual cylinder timing variation.

03 NATURAL GAS↗

Frequency based electric vehicle charge controller system and method for implementing demand response and regulation services to power grid using frequency detection

Frequency responsive charging for plug-in hybrid electric vehicles (PHEV) and battery electric vehicles (BEV), a frequency sensing charging system and a method are provided for implementing demand response and regulation services to power grid using frequency detection for a frequency-based charge controller for plug-in hybrid electric vehicles (PHEV) and battery electric vehicles (BEV). A frequency of the power grid is continuously monitored and compared to a predefined tolerance band by a frequency sensor. Responsive to the frequency being outside the predefined tolerance band, the frequency is applied to a programmable logic controller. The programmable logic controller uses the applied frequency to identify a control action. A charge controller and a switch coupled to a battery charger receive respective identified control actions for controlling the battery charger.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pilot-Scale CFP Commissioning: Creative Problem Solving and Lessons Learned

We have commissioned a pilot-scale, ex-situ catalytic fast pyrolysis (CFP) reactor system in the Thermal and Catalytic Process Development Unit (TCPDU) at the National Renewable Energy Laboratory. The FCC-style CFP system, including a riser and continuous regeneration, was added to the existing half-ton-per-day biomass fast pyrolysis unit and was designed to run a zeolite-type catalyst. The system is unique due to its scale and catalyst flow control scheme. As the design of this system was informed by early data from a bench-scale reactor, several technical scale-up challenges had to be overcome. Additionally, physical constraints and the complexities of biomass vapors required and inspired creative solutions. This talk will discuss the specific challenges we found and addressed, including an oxygen deficiency in the regenerator and plugging in the exit streams. We explored several options for increasing oxygen availability and selected a cyclone-catalyst return design on the exit line so we could increase air flow through the regenerator. We found that hot gas filtration is essential in any exit streams containing water vapor and trace amounts of catalyst; any combination of catalyst and condensate quickly makes mud that plugs equipment and severely limits run time. Duplicate filters are also required to extend run time. Most of the equipment and solutions were designed and installed by our team of engineers and technicians, working closely together in an iterative process to design, install, operate, then redesign. Collaborations with other national laboratories with computational fluid dynamics expertise helped inform designs and identify creative solutions to these scale-up challenges. Ultimately, data from the reactor system will be used to validate a comprehensive kinetic model of CFP that can be used to better design and inform new systems at various scales.

09 BIOMASS FUELS↗

Market Segmentation Analysis of Medium and Heavy Duty Trucks with a Fuel Cell Emphasis

The medium- and heavy-duty transportation sector is experiencing rapid changes in powertrain technology innovation with recent announcements of battery electric and fuel cell electric trucks being offered. However, the economics of these alternative powertrain vehicles are uncertain and difficult to compare directly. This analysis seeks to bridge the gap of techno-economic analyses for these alternative powertrain vehicles by comparing all of them within the same analytic framework. Specifically, this report evaluates the total cost of ownership (TCO) of six different truck powertrain technologies (diesel, diesel hybrid-electric, plug-in hybrid electric, compressed natural gas, battery electric, and fuel cell electric) for three different truck vocations (Class 8 long haul [750 mile range], Class 8 short haul [300 mile range], and Class 4 parcel delivery), for different Department of Energy technology statuses (2018, 2025, and Ultimate). The TCO framework includes direct costs (purchase price, fuel, operating and maintenance), indirect costs (dwell time costs due to refueling/recharging and payload opportunity costs from forgone revenue due to the truck being weight-limited), but excludes general operation costs (driver wages and benefits, insurance, tire replacements, permits, tolls) that are assumed to be the same across powertrains. The TCO was evaluated for four scenarios that reflect typical business operating conditions. The TCO analysis results highlight that each powertrain technology may have an economic advantage on a TCO basis in certain business operating conditions and depending on fuel price realized. For Class 8 long haul trucks when payload opportunity costs are not incurred, battery electric and fuel cell electric powertrains could be cost competitive with diesel if the 2025 targets are achieved and fuel prices are low. If payload opportunity costs are incurred, battery electric powertrains are not estimated to reach TCO parity with diesel even if Ultimate targets and low electricity prices are realized, indicating a need for significant vehicle lightweighting. In Class 8 short haul commercial applications when payload opportunity costs are not incurred, battery electric, fuel cell electric, and compressed natural gas vehicle powertrains have very competitive TCOs with diesel if the 2025 targets are achieved. In Class 8 short haul commercial applications when payload opportunity costs are incurred, the battery electric vehicle powertrains can achieve TCO parity with diesel only if the Ultimate battery prices are met ($80/kWh). In Class 4 parcel delivery truck operating scenarios where there are no dwell time costs incurred, the plug-in hybrid electric vehicle, battery electric vehicle, and fuel cell electric vehicle could be cost-competitive with diesel and compressed natural gas with current (2018) technology performance and costs. In general, the payload opportunity costs can be a significant driver to TCO for the Class 8 long and short haul commercial vehicle applications while the dwell time costs could be a major TCO cost driver for the Class 4 parcel delivery vehicle if the business scenario realizes those costs.

advanced powertrains↗

Optimal Efficiency and Operational Cost Savings: A Framework for Automated Rooftop PV Placement

Residential energy consumers are charged based on a utility rate structure, such as net metering or feed-in tariff. To lower consumers' electricity bills, expensive batteries are deployed to reduce the electricity fed from the grid during peak hours. However, strategic photovoltaic (PV) panel placement enables the reduction of operational energy cost while considering the spatial feasibility and efficiency for hosting rooftop PV. In this paper, we present a framework to automatically identify the optimal location of rooftop PV panels on residential buildings. Our framework integrates multiple workflows, including energy and environmental simulation, parametric modeling, and optimization to identify the ideal location of PV panels to balance the demand and supply at a building and community scale. These workflows are linked using the Grasshopper plug-in for Rhinoceros CAD software. The framework includes two different workflows, each satisfying a target for optimal PV placement: (a) maximizing PV panel efficiency, where users aim to maximize energy generation, and (b) minimizing operational energy cost, where "best'' panels are selected considering utility rates for operational energy cost. Our framework is demonstrated in a residential community in Fort Collins, Colorado, to generate the optimal PV placement for each of the two aforementioned targets. Results from the two workflows are compared to illustrate the effect of PV location and orientation on solar energy production efficiency and operational energy cost. The developed workflows are introduced as tools within the Grasshopper plug-in to investigate the solar potential of rooftop PV panels while taking into account factors such as contextual shading, utility rate structures, and buildings' energy demand profiles.

30 DIRECT ENERGY CONVERSION↗

High temperature synthesis for power production and storage

A reservoir for containing a fluid includes a cylindrical wall sized to engage a shaft bored into ground, a bottom end cap fixed to a lower end of the cylindrical wall and a top end cap fixed to an upper end of the cylindrical wall. The top end cap is concave such that the top end cap extends below a top end of the cylindrical wall. The bottom end cap, the top end cap, and the cylindrical wall define a subterranean chamber. A plug made of a composite material is on the top end cap, with a lower face disposed on the concave top end cap and a peripheral face engaging the shaft. At least one pressure port extends downwardly into the shaft and through the plug and the top end cap, defining a fluid path to the subterranean chamber.

Lovegrove, Keith↗