Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHOTODETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Space Telescope Digicon

The Digicon, chosen by NASA as the detector for the High Resolution Spectrograph (HRS) and the Faint Object Spectrograph (FOS) is a 512 parallel output channel vacuum photodetector. There are two HRS Digicons with spectral sensitivity ranges from 1050 A to 1800 A and 1150 A to 3000 A respectively, and two FOS Digicons, which have spectral ranges extending to 7000 A. The significant requirements for these devices are 0.01 counts per second background count rate per diode, state-of-the-art Digicon pulse height resolution (typical 15%) and a high degree of imaging precision and stability. The results of a manufacturing and test program to develop the Digicons coupled with extensive prior work has shown that these requirements can be met. The Digicon because of its inherent ruggedness is particularly well suited to space applications.

Alting-Mees, H. R.↗

Interferometer Accurately Measures Rotation Angle

Interference fringes from superimposed beams move across a photodetector, creating electrical pulses. Frequency of pulses is direct measure of angular velocity of rotating body. If separation of the sources changes, it affects separation of all fringes equally and does not affect angular velocity measurement.

Minott, P. O.↗

Acousto-optic spectrometer for radio astronomy

Recent developments in acousto-optic techniques and in photodetector arrays have made feasible a new type of RF spectrometer, offering the advantages of wide bandwidth, high resolution, large number of channels in compact, lightweight, energy efficient, and relatively low cost systems. Such a system employs an acousto-optic diffraction cell which serves the key role of converting RF signals to ultrasonic traveling-waves modulating the optical index of the cell. The cell is illuminated across its aperture by a monochromatic laser beam. A fraction of the light is diffracted by the acoustic waves. A focusing lens follows the cell and essentially performs a Fourier transform of the RF signal into a far-field intensity pattern. CSIRO in Australia and the Tokyo Astronomical Observatory in Japan have taken the lead in using acousto-optic techniques in astronomical applications. The first practical device was successfully made at CSIRO for obtaining dynamical spectrographs of solar radio emission.

Chin, G.↗

A description of the UK Meteorological Office CCN counter

The chamber is a thermal gradient diffusion type with the upper plate at room temperature and the lower plate thermoelectrically cooled. The light from a 25W projector bulb is focused in a beam of approximations 1x3 mm in the central part of the chamber. The light scattered by drops is viewed in the forward direction (40 deg) by a microscope and a sensitive photodetector. Experiments were performed to relate the peak output from the photocell with the maximum number of drops in the beam recorded photographically. The microscope is used to check the calibration at low concentrations of CCN. The results of the experiments and the performance of the counter are reported.

Kitchen, M.↗

Bulk and integrated acousto-optic spectrometers for radio astronomy

The development of sensitive heterodyne receivers (front end) in the centimeter and millimeter range, and the construction of sensitive RF spectrometers (back end) enable the spectral lines of interstellar molecules to be detected and identified. A technique was developed which combines acoustic bending of a collimated coherent light beam by a Bragg cell followed by detection by a sensitive array of photodetectors (thus forming an RF acousto-optic spectrometer (AOS). An AOS has wide bandwidth, large number of channels, and high resolution, and is compact, lightweight, and energy efficient. The thrust of receiver development is towards high frequency heterodyne systems, particularly in the millimeter, submillimeter, far infrared, and 10 micron spectral ranges.

Chin, G.↗

Interferometric surface-wave acousto-optic time-integrating correlators

A structure for a coherent-interferometric acousto-optic (AO) time-integrating correlator was implemented by using a single surface acoustic wave (SAW) device with tilted transducers to reduce intermodulation terms. The SAW device was fabricated on Y-Z LiNbO3 with a center frequency of 175 MHz, a bandwidth of 60 MHz, and a time aperture of about 10 micros. The density of the photodetector array, with a potential of 120 MHz. Typical integration times are 30 to 40 ms, providing processing gains in excess of 10 to the 6th power. Such a device is useful in providing fast synchronization of communication links and in demodulating to base band and simultaneously acting as a synchronization lock monitor for moderate data rates. Where processing may be limited by Doppler shifts, a two dimensional architecture was implemented to allow full processing gain. Two one-dimensional, SAW AO time-integrating correlators and a two dimensional correlator are evaluated.

Berg, N. J.↗

Error probabilities in optical PPM receivers with Gaussian mixture densities

A Gaussian mixture density arises when a discrete variable (e.g., a photodetector count variable) is added to a continuous Gaussian variable (e.g., thermal noise). Making use of some properties of photomultiplier Gaussian mixture distributions, some approximate error probability formulas can be derived. These appear as averages of M-ary orthogonal Gaussian error probabilities. The use of a pure Gaussian assumption is considered, and when properly defined, appears as an accurate upper bound to performance.

Gagliardi, R. M.↗

Evaluation of an electro-optic remote displacement measuring system

An instrumentation system to provide a noncontact method for measurement of target positions was evaluated. The system employs two electro-optic camera units which give stereo information for use in determining three dimensional target locations. Specially developed, infrared sensitive photodetectors are used in the cameras to sense radiation from light emitting diode targets. Up to 30 of these targets can be monitored with a sampling rate of 312 Hz per target. An important part of the system is a minicomputer which is used to collect the camera data, sort it, make corrections for distortions in the electro-optic system, and perform the necesssary coordinate transformations. If target motions are restricted to locations in a plane which is perpendicular to a camera's optical axis, the system can be used with just one camera. Calibrations performed in this mode characterize accuracies in single camera operation. This information is also useful in determination of single camera contributions to total system errors. For this reason the system was tested in both the single camera and two camera (stereo) modes of operation.

Monteith, J. H.↗

A comparison of lidar and balloon-borne particle counter measurements of the stratospheric aerosol 1974-1980

The optical radar measurements considered in the present investigation are those which have been obtained routinely at Hampton, VA (37.1 deg N, 76.3 deg W) since 1974. The dustsonde measurements are those made monthly at Laramie, WY (41.2 deg N, 105 deg W). The extensive data sets acquired with these two instruments during the time period 1974-80 permit a long-term comparison of the two different measurement techniques. The balloon-borne dustsonde pumps ambient air in a well-defined stream through an illuminated chamber where individual aerosol particles scatter light into photodetectors. The optical radar system used in the studies has a ruby laser with a 48-inch Cassegrainian configured telescope mounted on a mobile platform to collect the backscattered laser light. The investigation shows that optical radar measurements, dustsonde measurements, and realistic optical models together give a very consistent picture of stratospheric aerosol behavior.

Swissler, T. J.↗

Bolometer and photosensitive detector systems for IR

In order to achieve the full sensitivity required for future space astronomy applications, IR detector systems will have to be cooled to 0.1 K or less. The feasibility of such cryocooling has been demonstrated for the established laboratory technique of adiabatic demagnetization, and it has been shown that bolometers made from compensated silicon, with ion-implanted contacts, come close to calculated ultimate performance limits. Unlike bolometers, silicon and germanium photoconductors are highly wavelength-dependent. Useful wavelengths are presented for the most promising photodetectors based on these materials. It is noted that, as the relevant microelectronic technology advances, array detectors in the near-IR may be expected to approach the size and performance of large, intrinsic silicon CCD arrays now available for optical wavelengths.

Low, F. J.↗

Measuring Excess Noise in SDL's

New instrument gives quantitive information on "excess noise" in semiconductor-diode laser (SDL's). By proper selection of detector, instrument tests any SDL from visible wavelengths through thermal infrared. Lasers determine excess noise in SKL source by measuring photocurrent generated in photodetector exposed first to reference laser then to SKL under test.

Katzberg, S. J.↗

Ultrasonics and Optics Would Control Shot Size

Feedback system assures production of silicon shot of uniform size. Breakup of silicon stream into drops is controlled, in part, by varying frequency of vibrations imparted to stream by ultrasonic transducer. Drop size monitored by photodetector. Control method particularly advantageous in that constant size is maintained even while other process variables are changed deliberately or inadvertently. Applicable to materials other than silicon.

Morrison, A. D.↗

Self-Modulated Laser Rangefinder

Longitudinal resonance modes exploited. Self-modulated-laser ranging system exploits presence of signals differing in frequency by longitudinalmode separation frequency fm. Two square-law photodetectors have outputs modulated by fm, and phase difference between two outputs is related to target distance. Laser transmitter/receiver measures distances as well as displacements of distant objects (such as vibrating buildings).

Abshire, J. B.↗

Optical Turbopump Speed Sensor

Optical tachometer measures shaft rotation from outside turbopump housing. Laser-diode beam passes through quartz lens into shaft nut with alternating reflective and nonreflective surfaces. Reflected pulses collected by lens and transmitted to photodetector.

Swain, D.↗

The relationship of sensor parameters to applications data analysis

A stochastic model for the data acquisition system in a multispectral scanner system, like the one utilized by the LANDSAT satellites, is presented. A list of noise sources which are known or presumed to have a significant effect in the information extraction process was constructed. Since the shot noise introduced by the photodetectors in the sensor system is signal level dependent, an atmospheric model was adopted which could adequately describe the amount of radiation that gets into the sensors based on the atmospheric transmittance. An analysis was carried out to find the output spectral statistics in terms of the input signal statistics and the system parameters. This was integrated into a set of FORTRAN programs that when supplied with, the class statistics, the noise levels introduced by the sensor system, the atmospheric transmittance, and the atmospheric path radiance, can be used to estimate the classification performance. In order to show the beneficts of this model a series of runs were performed in which the Thematic Mapper multispectral scanner was the system under consideration.

Landgrebe, D. A.↗

Laser system for natural gas detection. Phase 1: Laboratory feasibility studies

This project demonstrated the feasibility of using laser remote sensing technology as a tool for leak survey work in natural gas distribution systems. A laboratory device was assembled using a pair of helium neon (HeNe) lasers to measure methane. One HeNe laser emits radiation at a wavelength of 3.3922 micrometers, which corresponds to a strong absorption feature of methane, while the other emits radiation at a wavelength of 3.3911 micrometers, which corresponds to a weak absorption by methane. As a particular area is scanned for leaks, the laser is pointed at convenient topographic targets within its operating range, about 25 m. A portion of the backscattered radiation is collected by a receiver and focused onto an indium antimonide (InSb) photodetector, cooled to 77K. Methane concentrations were determined from the differential absorption at the two wavelengths for the backscattered radiation.

Grant, W. B.↗

Interferometric angle monitor

Two mutually coherent light beams formed from a single monochromatic light source were directed to a reflecting surface of a rotatable object. They were reflected into an imaging optical lens having a focal plane optically at infinity. A series of interference fringes were formed in the focal plane which were translated linearly in response to angular rotation of the object. Photodetectors were located adjacent the focal plane to detect the fringe translation and output a signal in response to the translation. The signal was fed to a signal processor which was adapted to count the number of fringes detected and develop a measure of the angular rotation and direction of the object.

Minott, P. O.↗