Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Quantitative x-ray scattering of free molecules

Advances in x-ray free electron lasers have made ultrafast scattering a powerful method for investigating molecular reaction kinetics and dynamics. Accurate measurement of the ground-state, static scattering signals of the reacting molecules is pivotal for these pump-probe x-ray scattering experiments as they are the cornerstone for interpreting the observed structural dynamics. Here, this article presents a data calibration procedure, designed for gas-phase x-ray scattering experiments conducted at the Linac Coherent Light Source x-ray Free-Electron Laser at SLAC National Accelerator Laboratory, that makes it possible to derive a quantitative dependence of the scattering signal on the scattering vector. A self-calibration algorithm that optimizes the detector position without reference to a computed pattern is introduced. Angle-of-scattering corrections that account for several small experimental non-idealities are reported. Their implementation leads to near quantitative agreement with theoretical scattering patterns calculated with ab-initio methods as illustrated for two x-ray photon energies and several molecular test systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

Multi-probe microstructure tracking during heat treatment without an in-situ setup: Case studies on martensitic steel, dual phase steel and β-Ti alloy

In-situ scanning electron microscopy observations of the microstructure evolution during heat treatments are increasingly demanded due to the growing number of alloys with complex microstructures. Post-mortem characterization of the as-processed microstructures rarely provides sufficient insight on the exact route of the microstructure formation. On the other hand, in-situ SEM approaches are often limited due to the arising challenges upon using an in-situ heating setup, e.g. in (i) employing different detectors, (ii) preventing specimen surface degradation, or (iii) controlling and measuring the temperature precisely. Here, we explore and expand the capabilities of the “mid-way” solution by step-wise microstructure tracking, ex-situ, at selected steps of heat treatment. This approach circumvents the limitations above, as it involves an atmosphere and temperature well-controlled dilatometer, and high resolution microstructure characterization (using electron channeling contrast imaging, electron backscatter diffraction, atom probe tomography, etc.). We demonstrate the capabilities of this approach by focusing on three cases: (i) nano-scale carbide precipitation during low-temperature tempering of martensitic steels, (ii) formation of transformation-induced geometrically necessary dislocations in a dual-phase steel during intercritical annealing, and (iii) the partial recrystallization of a metastable β-Ti alloy. - Highlights: • A multi-probe method to track microstructures during heat treatment is developed. • It enables the analysis of various complex phenomena, even those at atomistic scale. • It circumvents some of the free surface effects of classical in-situ experiments.

36 MATERIALS SCIENCE↗

SU-D-17A-07: Development and Evaluation of a Prototype Ultrasonography Respiratory Monitoring System for 4DCT Reconstruction

Purpose: Respiratory motion artifacts are commonly seen in the abdominal and thoracic CT images. A Real-time Position Management (RPM) system is integrated with CT simulator using abdominal surface as a surrogate for tracking the patient respiratory motion. The respiratory-correlated four-dimensional computed tomography (4DCT) is then reconstructed by GE advantage software. However, there are still artifacts due to inaccurate respiratory motion detecting and sorting methods. We developed an Ultrasonography Respiration Monitoring (URM) system which can directly monitor diaphragm motion to detect respiratory cycles. We also developed a new 4DCT sorting and motion estimation method to reduce the respiratory motion artifacts. The new 4DCT system was compared with RPM and the GE 4DCT system. Methods: Imaging from a GE CT scanner was simultaneously correlated with both the RPM and URM to detect respiratory motion. A radiation detector, Blackcat GM-10, recorded the X-ray on/off and synchronized with URM. The diaphragm images were acquired with Ultrasonix RP system. The respiratory wave was derived from diaphragm images and synchronized with CT scanner. A more precise peaks and valleys detection tool was developed and compared with RPM. The motion is estimated for the slices which are not in the predefined respiratory phases by using block matching and optical flow method. The CT slices were then sorted into different phases and reconstructed, compared with the images reconstructed from GE Advantage software using respiratory wave produced from RPM system. Results: The 4DCT images were reconstructed for eight patients. The discontinuity at the diaphragm level due to an inaccurate identification of phases by the RPM was significantly improved by URM system. Conclusion: Our URM 4DCT system was evaluated and compared with RPM and GE 4DCT system. The new system is user friendly and able to reduce motion artifacts. It also has the potential to monitor organ motion during therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of the Production Cross Section for Pairs of Isolated Photons in pp collisions at sqrt(s) = 7 TeV

The integrated and differential cross sections for the production of pairs of isolated photons is measured in proton-proton collisions at a centre-of-mass energy of 7 TeV with the CMS detector at the LHC. A data sample corresponding to an integrated luminosity of 36 inverse picobarns is analysed. A next-to-leading-order perturbative QCD calculation is compared to the measurements. A discrepancy is observed for regions of the phase space where the two photons have an azimuthal angle difference, $\Delta(\phi)$, less than approximately 2.8.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling the response of a fast ion loss detector using orbit tracing techniques in a neutral beam prompt-loss study on the DIII-D tokamak

A numerical model describing the expected measurements of neutral beam prompt-losses by a newly commissioned fast ion loss detector (FILD) in DIII-D is presented. This model incorporates the well understood neutral beam deposition profiles from all eight DIII-D beamlines to construct a prompt-loss source distribution. The full range of detectable ion orbit phase space available to the FILD is used to calculate ion trajectories that overlap with neutral beam injection footprints. Weight functions are applied to account for the level of overlap between these detectable orbits and the spatial and velocity (pitch) properties of ionized beam neutrals. An experimental comparison is performed by firing each neutral beam individually in the presence of a ramping plasma current. Fast ion losses determined from the model are in agreement with measured losses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DESIGN OF A THERMOSIPHON FOR COOLING LOW-BACKGROUND HPGE ARRAYS

ABSTRACT A two-phase nitrogen thermosiphon was developed for the new generation of low-background high-purity germanium (HPGe) arrays. The cooling system for these arrays has to be able to handle the heat load (>20 W) presented by a large detector mass while meeting stringent requirements necessary for low-background systems. The HPGe detector modules should operate as close to liquid nitrogen temperature (<80K) as possible to provide adequate operating conditions for a full range of HPGe impurity concentrations. In addition, exceptional temperature stability (<1 K) is needed to reduce electronic gain shifts due to changes in the front-end electronics operating temperature. In order to meet the background requirements of state-of-the-art systems these arrays are enclosed in passive lead and copper shielding up to 1 m thick. In this paper we present a cooling system for low-background experiments that complies with these stringent geometrical restrictions. Active cooling was integrated via a horizontal thermosiphon that can be fabricated using ultra-pure electroformed copper. It was charged with nitrogen to 434 kPa (63 PSIA) at 292 K, which provided a fill ratio of 10%. The results showed that the thermosiphon can effectively remove in excess of 25 W of heat load.

low-background, thermal conductivity, radiation de↗

Direct search for dark matter with DarkSide

Here, the DarkSide experiment is designed for the direct detection of Dark Matter with a double phase liquid Argon TPC operating underground at Laboratori Nazionali del Gran Sasso. The TPC is placed inside a 30 tons liquid organic scintillator sphere, acting as a neutron veto, which is in turn installed inside a 1 kt water Cherenkov detector. The current detector is running since November 2013 with a 50 kg atmospheric Argon fill and we report here the first null results of a Dark Matter search for a (1422 ± 67) kg.d exposure. This result correspond to a 90% CL upper limit on the WIMP-nucleon cross section of 6.1 × 10 -44 cm 2 (for a WIMP mass of 100 GeV/c 2 ) and it's currently the most sensitive limit obtained with an Argon target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Discriminating strange star mergers from neutron star mergers by gravitational-wave measurements

We perform three-dimensional relativistic hydrodynamical simulations of the coalescence of strange stars and explore the possibility to decide on the strange matter hypothesis by means of gravitational-wave measurements. Self-binding of strange quark matter and the generally more compact stars yield features that clearly distinguish strange star from neutron star mergers, e.g. hampering tidal disruption during the plunge of quark stars. Furthermore, instead of forming dilute halo structures around the remnant as in the case of neutron star mergers, the coalescence of strange stars results in a differentially rotating hypermassive object with a sharp surface layer surrounded by a geometrically thin, clumpy high-density strange quark matter disk. We also investigate the importance of including nonzero temperature equations of state in neutron star and strange star merger simulations. In both cases we find a crucial sensitivity of the dynamics and outcome of the coalescence to thermal effects, e.g. the outer remnant structure and the delay time of the dense remnant core to black hole collapse depend on the inclusion of nonzero temperature effects. For comparing and classifying the gravitational-wave signals, we use a number of characteristic quantities like the maximum frequency during inspiral or the dominant frequency of oscillations of the postmerger remnant. In general, these frequencies are higher for strange star mergers. Only for particular choices of the equation of state the frequencies of neutron star and strange star mergers are similar. In such cases additional features of the gravitational-wave luminosity spectrum like the ratio of energy emitted during the inspiral phase to the energy radiated away in the postmerger stage may help to discriminate coalescence events of the different types. If such characteristic quantities could be extracted from gravitational-wave signals, for instance with the upcoming gravitational-wave detectors, a decision on the strange matter hypothesis and the existence of strange stars should be possible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detection of regional infrasound signals using array data: Testing, tuning, and physical interpretation

This work quantifies the physical characteristics of infrasound signal and noise, assesses their temporal variations, and determines the degree to which these effects can be predicted by time-varying atmospheric models to estimate array and network performance. An automated detector that accounts for both correlated and uncorrelated noise is applied to infrasound data from three seismo-acoustic arrays in South Korea (BRDAR, CHNAR, and KSGAR), cooperatively operated by Korea Institute of Geoscience and Mineral Resources (KIGAM) and Southern Methodist University (SMU). Arrays located on an island and near the coast have higher noise power, consistent with both higher wind speeds and seasonably variable ocean wave contributions. On the basis of the adaptive F-detector quantification of time variable environmental effects, the time-dependent scaling variable is shown to be dependent on both weather conditions and local site effects. Significant seasonal variations in infrasound detections including daily time of occurrence, detection numbers, and phase velocity/azimuth estimates are documented. These time-dependent effects are strongly correlated with atmospheric winds and temperatures and are predicted by available atmospheric specifications. As a result, this suggests that commonly available atmospheric specifications can be used to predict both station and network detection performance, and an appropriate forward model improves location capabilities as a function of time.

47 OTHER INSTRUMENTATION↗

Kinetic instabilities and turbulence in photonic plasma

The purpose of this proposal was to study the statistical dynamics of plasma and demonstrate it experimentally in all-optical systems. That this was possible followed from (1) a direct mapping between the equations of plasma kinetics and the nonlinear propagation of statistical light and (2) advances in photonic technology, which enabled versatile control of the input conditions and direct imaging of the output fields. At the start of the proposal, theory exploiting the optics plasma relationship was minimal, and few experiments had been performed. By the end, the field of photonic plasma had been firmly established. There were two main themes in the proposal. The first was optical confirmation of existing plasma theory, particularly where competing theories or numerical codes needed to be distinguished. The second was the genesis of new research directions for plasma, both fundamentally and for applications. These arose naturally from the proposed projects, as experiment raises different questions than theory, while optics gives a much different perspective than material science. The photonic analogues also provide a unified language for many issues that are difficult (and expensive) to study directly, such as high-energy laser-plasma interactions. Moreover, basic imaging techniques enable measurements that are difficult, if not impossible, in material plasma. For example, Debye shielding hides internal dynamics from outside detectors while nonlinear interactions must often be inferred by deviations from linear expectations. In contrast, optics allows the creation of a wide range of spatial and spectral distributions, along with high-resolution measurements in the full position-momentum phase space.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High speed, multi-channel, user programmable digital data acquisition system.

As applications for radiation detection become more demanding, and in turn improvements are made in the technology of radiation detection, there is a need for high speed digital detector readout electronics matching these improvements. Specifically, full control over the on-line processing resources of modern digital electronics is desirable so that researchers can develop custom algorithms for special applications.In the proposed effort, the 500 MHz digital readout electronics previously developed by our company will be redesigned to allow user access to the on-line processing resources. In Phase I, the division of online processing into vendor and user firmware sections has been studied on existing hardware. In Phase II, the hardware will be upgraded to better facilitate the division, and the firmware will be restructured into a robust vendor logic block (providing standard functions such as host I/O, on-board memory I/O, energy computation, MCA spectra, timestamps, waveform capture, run statistics, and triggering and timing) and a user logic block for custom algorithms (with templates and examples for frequently used functions). Investigating several options to divide online processing, it was determined that the most promising approach is to “partition” a single FPGA integrated circuit into a vendor and user section, which is supported in newer devices. The analog front end of the existing electronics proved suitable for most applications, in particular high rate measurements with germanium detectors. The design architecture for new electronics was developed, combining one of the new FPGA device with the analog front end.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of the angular orientation for a fast ion loss detector in a tokamak

A scintillator type fast ion loss detector measures the gyroradius and pitch angle distribution of superthermal ions escaping from a magnetically confined fusion plasma at a single location. Described here is a technique for optimizing the angular orientation of such a detector in an axisymmetric tokamak geometry in order to intercept losses over a useful and interesting ranges of pitch angle. The method consists of evaluating the detector acceptance as a function of the fast ion constants of motion, i.e. energy, canonical toroidal momentum, and magnetic moment. The detector acceptance can then be plotted in a plane of constant energy and compared with the relevant orbit class boundaries and fast ion source distributions. Knowledge of expected or interesting mechanisms of loss can further guide selection of the detector orientation. The example of a fast ion loss detector for the National Spherical Torus Experiment-Upgrade (NSTX-U) is considered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physical Properties of Candidate X-ray Detector Material Rb 4 Ag 2 BiBr 9

Recently, metal halide perovskites have emerged as promising semiconductor candidates for sensitive X-ray photon detection due to their suitable band gap energies, excellent charge transport properties, and low material cost afforded by their low-temperature solution-processing preparation. Furthermore, we report an improved methodology for single crystal growth and thermal and electrical properties of a two-dimensional (2D) layered halide material Rb 4 Ag 2 BiBr 9 , which has been identified as a potential candidate for X-ray radiation detection applications. The measured heat capacity for Rb 4 Ag 2 BiBr 9 implies that there are no structural phase transitions upon cooling. Temperature dependence of thermal transport measurements further suggests remarkably low thermal conductivities of Rb 4 Ag 2 BiBr 9 that are comparable to the lowest reported in literature. The bulk crystal resistivity is determined to be 2.59 × 10 9 Ω·cm from the current–voltage (I–V) curve. Density of trap states is estimated to be ~10 10 cm –3 using the space-charge-limited-current measurements. The fabricated Rb 4 Ag 2 BiBr 9 -based X-ray detector shows good operational stability with no apparent current drift, which may be ascribed to the 2D crystal structure of Rb 4 Ag 2 BiBr 9 . Finally, by varying the X-ray tube current to change the corresponding dose rate, the Rb4Ag2BiBr9 X-ray detector sensitivity is determined to be 222.03 μC Gy –1 cm –2 (at an electric field of E = 24 V/mm).

36 MATERIALS SCIENCE↗

Proton Scattering in NOvA Test Beam

The NuMI Off-axis $\nu_e$ Appearance (NOvA) experiment is a two-detector, long baseline, neutrino oscillation experiment, which aims to make a determination of the neutrino mass ordering, the octant of $\theta_{23}$, and measure possible charge-parity (CP) violation. Determining these parameters is a step towards answering some of the fundamental questions about neutrinos. Are neutrinos their own antiparticle? Could neutrinos be responsible for the matter-antimatter asymmetry of the universe? How do neutrinos get their mass? Answering these questions requires precise measurements of the parameters that govern how neutrinos behave, namely the mass squared splittings, mixing angles, and possible CP-violating phase factor in the PNMS matrix. Reaching high precision requires minimizing both statistical and systematic errors. As NOvA continues to accumulate data, the sizes of our statistical errors continue to shrink such that in a couple of years they will be comparable to our systematic errors. NOvA's current systematic errors are dominated by energy and calibration uncertainties. The Test Beam program was initiated to address these uncertainties by assessing the detector response in an environment where more parameters of the incoming particles are known. One of the main goals of the Test Beam program is to garner a better understanding of our systematic errors, particularly in energy measurement and detector response, so that the modeling of these parameters can be improved. I studied protons in the Test Beam Detector with momenta around \unit[1]{GeV/c}, the high end of the momentum range relevant to quasielastic neutrino interactions in NOvA. One question this sample can help to answer is if we correctly simulate the fraction of protons that have an inelastic scattering interaction versus ranging out. If protons inelastically scatter at different rates in our simulation and data, the correction applied to the hadronic system when reconstructing neutrino energy could be inaccurate, since events with inelastic scattering will have less visible energy in the detector. This is particularly important for quasielastic $\nu_\mu$ events, which have the lowest hadronic energy resolution, and therefore give us our best measurements of $\Delta m_{32}^2$ and $\theta_{23}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exotic quarkonium states in CMS

The studies of the production of the X(3872), either prompt or from B-hadron decays, and of the J/ψϕ mass spectrum in B-hadron decays have been carried out by using pp collisions at √s = 7 TeV collected with the CMS detector at the LHC. The cross-section ratio of the X(3872) with respect to the ψ(2S) in the J/ψπ{sup +}π{sup −} decay channel and the fraction of X(3872) coming from B-hadron decays are measured as a function of transverse momentum (p{sub T}), covering unprecedentedly high values of p{sub T}. For the first time, the prompt X(3872) cross section times branching fraction is extracted differentially in p{sub T} and compared with NRQCD predictions. The dipion invariant-mass spectrum of the J/ψπ{sup +}π{sup −} system in the X(3872) decay is also investigated. A peaking structure in the J/ψϕ mass spectrum near threshold is observed in B{sup ±} → J/ψϕK{sup ±} decays. The data sample, selected on the basis of the dimuon decay mode of the J/ψ, corresponds to an integrated luminosity of 5.2 fb{sup −1}. Fitting the structure to an S-wave relativistic Breit–Wigner lineshape above a three-body phase-space nonresonant component gives a signal statistical significance exceeding five standard deviations. The fitted mass and width values are m = 4148.0 ± 2.4(stat.) ± 6.3(syst.) MeV and Γ = 28+15 − 11(stat.) ± 19(syst.) MeV, respectively. Evidence for an additional peaking structure at higher J/ψϕ mass is also reported.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

KM3NeT

KM3NeT is a large research infrastructure, that will consist of a network of deep-sea neutrino telescopes in the Mediterranean Sea. The main objective of KM3NeT is the discovery and subsequent observation of high-energy neutrino sources in the Universe. A further physics perspective is the measurement of the mass hierarchy of neutrinos. A corresponding study, ORCA, is ongoing within KM3NeT. A cost effective technology for (very) large water Cherenkov detectors has been developed based on a new generation of low price 3-inch photo-multiplier tubes. Following the successful deployment and operation of two prototypes, the construction of the KM3NeT research infrastructure has started. The prospects of the different phases of the implementation of KM3NeT are summarised.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved motional Stark effect signal processing using fast Fourier transform spectral analysis

A Fast Fourier Transform (FFT) based method has been developed, which improves the frequency response of the Motional Stark Effect (MSE) system by about a factor of 10 over the conventional analog lock-in method. The method uses fits to rigorously derived analytic expressions for the FFT spectral components of the MSE signal to accurately obtain the amplitudes and phases of the 2f1 and 2f2 photo-elastic modulator (PEM) frequencies that encode the polarization angle. Since no frequency filtering is used in the FFT method, the frequency response is limited by fundamental measurement properties: the frequency response of the detector, photon statistics, sample rate, and the ability to resolve the spectral components. In contrast, the frequency response of the analog lock-in is limited by a low pass filter with a cutoff of around 500 Hz. In the case of the DIII-D MSE system, the output of the photo-multiplier tube detector was sampled at 500 kHz and FFTs with as few as 100 points were used to obtain the amplitudes of the 2f1 and 2f2 PEM frequency components. This corresponds to a frequency response of 5 kHz, about ten times faster than the analog lock-in amplifier system. Details of the FFT method will be presented and compared to those of the analog lock-in system.

Makowski, M. A.↗

Exoplanet transit spectroscopy using WFC3: WASP-12 b, WASP-17 b, and WASP-19 b

We report an analysis of transit spectroscopy of the extrasolar planets WASP-12 b, WASP-17 b, and WASP-19 b using the Wide Field Camera 3 (WFC3) on the Hubble Space Telescope (HST). We analyze the data for a single transit for each planet using a strategy similar, in certain aspects, to the techniques used by Berta et al., but we extend their methodology to allow us to correct for channel- or wavelength-dependent instrumental effects by utilizing the band-integrated time series and measurements of the drift of the spectrum on the detector over time. We achieve almost photon-limited results for individual spectral bins, but the uncertainties in the transit depth for the band-integrated data are exacerbated by the uneven sampling of the light curve imposed by the orbital phasing of HST's observations. Our final transit spectra for all three objects are consistent with the presence of a broad absorption feature at 1.4 μm most likely due to water. However, the amplitude of the absorption is less than that expected based on previous observations with Spitzer, possibly due to hazes absorbing in the NIR or non-solar compositions. The degeneracy of models with different compositions and temperature structures combined with the low amplitude of any features in the data preclude our ability to place unambiguous constraints on the atmospheric composition without additional observations with WFC3 to improve the signal-to-noise ratio and/or a comprehensive multi-wavelength analysis.

79 ASTRONOMY AND ASTROPHYSICS↗