Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Occupant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Domestic Hot Water Temperature Maintenance Technology Review

Domestic hot water temperature maintenance (HWTM) is an important topic in facility management, and there are often opportunities to optimize systems to achieve energy, water, and maintenance savings. The main purpose of an HWTM system is to provide reliable hot water temperature at all fixtures with minimal wait time. This is done by replacing the standby heat losses from hot water sitting idle in pipes during periods of low demand. Traditionally, most commercial buildings do this by having water recirculate back to the water heater to be reheated. Other currently available HWTM systems are also discussed in this resource. HWTM systems can help maintain water at appropriate temperatures, minimize heat loss, and minimize delivery times to fixtures to improve the function of a building. This webpage includes a summary of HWTM options along with important considerations regarding occupant safety and comfort, and maintenance strategies for optimal and efficient operations. Domestic hot water (DHW) generation systems are referred to but are not the focus of this resource.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A System Approach to Deep Heating Savings Through Measurement, Management, and Motivation

Across multi-tenant commercial office and multifamily buildings, centrally metered fuel use represents a substantial fraction of whole-building energy use. Energy audit practitioners understand that improving heating distribution efficiency is typically more of an opportunity than combustion efficiency and that differing thermal comfort preferences between tenants are the bane of operators across these building typologies. There is an unmet market need for retrofit technologies that allow for the delivery of the right amount of heat to the right spaces, at the right time. The Energy Management and Information System (EMIS) package fills this gap through enhanced controls and metering, incorporating low-cost sensors and wireless communication infrastructure to provide a platform for ongoing commissioning and tenant feedback, including heat cost allocation. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Sentient Buildings, E Source, building owners, and utility and policy stakeholders, to demonstrate a market viable EMIS that achieves a reduction in space heating energy use by reducing heating load, improving control, and positively impacting behavior while providing an acceptable financial return. In this study, EMIS packages were implemented in two New York City multifamily rental buildings. Both buildings conducted basic mechanical work (e.g., repairing steam traps) to ensure the heating system was operating well before any tenant feedback was layered in. Heating Energy Use Reports (HEUR) were created to provide tenants with social comparisons and energy savings tips to influence their behavior; these were provided monthly to all tenants in both buildings. Additionally, one building allocated heating costs to a portion of the tenants. Heat cost allocation (HCA) has a long history in the European Union (EU), although it is not common in the US or in steam-heated buildings. SWA leveraged existing EU best practices and stakeholder feedback to develop a Heat Cost Allocation algorithm that was considered equitable and intuitive. Energy use and tenant behavior impacts were tracked throughout the study. The basic mechanical repair work saved between 11-20% of heating energy. Those savings rose to 17-24% with the addition of tenant feedback. While it may not be possible to precisely determine the impact of COVID-19 on research studies like this, there may have been additional savings realized had the study taken place in a period of normal occupancy patterns. These types of central heating systems have been a blind spot for utilities, who have traditionally had little visibility into detailed behind-the-meter gas usage. Heating energy savings stayed consistent during the coldest months, indicating the potential for utilities to utilize EMIS packages for peak gas demand reductions or demand response programs. Tenant comfort was also improved. Post installation, room temperatures more closely matched thermostat set points. Perhaps due to this greater level of control, the vast majority of tenants being billed for heating were accepting of the allocation costs. And tenants receiving heat cost allocations were more likely to reduce their thermostat setpoints than tenants receiving behavioral feedback without financial impacts were. Variation in building specifics makes it difficult to provide precise energy and financial savings estimates. But within the range of expected conditions, the study identified a few key variables that can have the greatest impact on financial returns: the cost of fuel, the ability and willingness to allocate heating costs to tenants, and a well-functioning heating system as a starting point. This study focused on two multifamily buildings, but additional use cases, such as commercial buildings and affordable housing, should be explored to better understand the full market potential. While this type of upgrade has the potential for deep energy reductions and cost savings, future projects should take into account the balance of costs and benefits between owners and tenants, especially in the affordable, regulated, or other low-to-moderate income (LMI) segments of the market. Rent credits, utility allowances, or a shared savings program are possible options to accelerate adoption of this strategy in these market segments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Systematic Enterprise Risk Management by Integrating the RISMC Toolkit and Cost-Benefit Analysis (Final Report)

The goal of this research is to theorize and quantify the relationships between safety and the financial performance of nuclear power plants (NPPs). The Socio-Technical Risk Analysis (SoTeRiA) theoretical framework, which connects the social aspects (e.g., safety culture) and structural features (e.g., safety practices) of an organization with organizational safety and financial risks, is used to theorize the direct and indirect relationships between safety and the financial performance of NPPs. An Integrated Enterprise Risk Management (I-ERM) methodological framework is developed to operationalize SoTeRiA to quantify NPP safety and financial performance in a unified platform where their underlying physical degradation mechanisms, coupled with maintenance performance (considering human and organizational factors), are explicitly incorporated to depict the interconnections and dependencies between safety and financial performance. In this study, NPP safety refers to both occupational safety and system safety (estimated from Probabilistic Risk Assessment, PRA), and financial performance refers to the monetary values associated with NPP operation and maintenance (O&M) strategies. This report covers a case study demonstrating the feasibility of the I-ERM methodological framework. More detailed development of one of the I-ERM modules, i.e., Probabilistic Physics-of-Failure (PPoF) analysis, and its connection with other I-ERM modules is demonstrated in a second case study. The outcome of this research will help NPP decision-makers create cost-saving maintenance strategies while maintaining safety by providing cost- and risk-informed recommendations regarding maintenance work processes and operational strategies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Leveraging Spin-Orbit Coupling in Ge/SiGe Heterostructures for Quantum Information Transfer

Hole spin qubits confined to lithographically - defined lateral quantum dots in Ge/SiGe heterostructures show great promise. On reason for this is the intrinsic spin - orbit coupling that allows all - electric control of the qubit. That same feature can be exploited as a coupling mechanism to coherently link spin qubits to a photon field in a superconducting resonator, which could, in principle, be used as a quantum bus to distribute quantum information. The work reported here advances the knowledge and technology required for such a demonstration. We discuss the device fabrication and characterization of different quantum dot designs and the demonstration of single hole occupation in multiple devices. Superconductor resonators fabricated using an outside vendor were found to have adequate performance and a path toward flip-chip integration with quantum devices is discussed. The results of an optical study exploring aspects of using implanted Ga as quantum memory in a Ge system are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Opaque Envelopes: Pathway to Building Energy Efficiency and Demand Flexibility: Key to a Low-Carbon, Sustainable Future

The opaque envelope - the barrier that helps maintain comfortable indoor conditions regardless of prevailing outdoor conditions - is the single largest contributor to primary energy use in residential and commercial buildings. Residential and commercial buildings comprise 39% of total U.S. primary energy use [1]. The opaque envelope affects 25% of building energy use, or 10% of total U.S. primary energy use [2]. High-performance opaque envelope technologies, therefore, have substantial potential to reduce energy use in both new construction and existing buildings. Retrofits are particularly crucial to realizing the energy savings potential of the opaque envelope because nearly 85% of residential and 55% of commercial buildings that exist today will still exist in 2050 [1]. Building envelope performance is also important for occupant comfort, productivity, health, and well-being. Improving the energy performance of the opaque envelope in U.S. buildings is critical to achieving aggressive cli- mate goals that support a clean energy economy and an equitable energy future for all Americans. By reducing total building energy use and improving energy efficiency, envelope research and development (R&D) will have a significant impact on how low-carbon buildings can mitigate climate change.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Fast-Cycle Charge Noise Measurement for Better Qubits

Defects in materials are an ongoing challenge for quantum bits, so called qubits. Solid state qubits—both spins in semiconductors and superconducting qubits—suffer from losses and noise caused by two-level-system (TLS) defects thought to reside on surfaces and in amorphous materials. Understanding and reducing the number of such defects is an ongoing challenge to the field. Superconducting resonators couple to TLS defects and provide a handle that can be used to better understand TLS. We develop noise measurements of superconducting resonators at very low temperatures (20 mK) compared to the resonant frequency, and low powers, down to single photon occupation.

36 MATERIALS SCIENCE↗

Historic Significance and Current Condition Assessment of Building 06-CP-170, the Yucca Flat Weather Station, Area 6, Nevada National Security Site, Nye County, Nevada

This report was produced in partial fulfillment of the mitigation of adverse effects to Building 06-CP-170, the Yucca Flat Weather Station on the Nevada National Security Site (NNSS), and is intended to comply with the 2021 Memorandum of Agreement DE-GM58-21NA25543 Between the U.S. Department of Energy and the Nevada State Historic Preservation Officer Regarding Demolition of Fourteen Buildings and Structures in Area 6 of the Nevada National Security Site, Nye County, Nevada (hereafter referred to as the MOA). This MOA was executed to resolve adverse effects from the U.S. Department of Energy (DOE) plan to demolish 14 architectural resources at the Control Point and in the vicinity in Area 6 of the NNSS. The management and operations contractor for the NNSS identified these 14 architectural resources as environmental hazards unsafe for human occupation due to deterioration and rodent infestation. Building 06-CP-170 is scheduled for demolition as part of this undertaking. Building 06-CP-170 was originally recorded in 2018 during a Section 106 cultural resources inventory for a proposed installation of a 138-kilovolt transmission line on the NNSS. The building was determined individually eligible by the DOE, in consultation with the Nevada State Historic Preservation Office, for inclusion in the National Register of Historic Places under the Secretary of the Interior’s Significance Criterion A because of its association with nuclear testing. Pursuant to Stipulation III.D.3 of the MOA, this report provides a summary of the historic significance of Building 06-CP-170 and a description of its current condition and accessory resources. In addition, an updated Architectural Resource Assessment (ARA) form with new information and photographs is included in the appendix in fulfillment of Stipulation III.D.2.

54 ENVIRONMENTAL SCIENCES↗

Historic Significance and Current Condition Assessment of Building 06-CP-10, Device Assembly Building, Area 6, Nevada National Security Site, Nye County, Nevada

This report was produced in partial fulfillment of the mitigation of adverse effects to Building 06-CP-10, the first device assembly building on the Nevada National Security Site (NNSS), and is intended to comply with the 2021 Memorandum of Agreement DE-GM58-21NA25543 Between the U.S. Department of Energy and the Nevada State Historic Preservation Officer Regarding Demolition of Fourteen Buildings and Structures in Area 6 of the Nevada National Security Site, Nye County (hereafter referred to as the MOA). This MOA was executed to resolve adverse effects from the U.S. Department of Energy (DOE) plan to demolish 14 architectural resources at the Control Point and in the vicinity in Area 6 of the NNSS. The management and operations contractor for the NNSS identified these 14 architectural resources as environmental hazards unsafe for human occupation due to deterioration and rodent infestation. Building 06-CP-10 and two small magazine bunkers (06-CP-10A and 06-CP-805) associated with Building 06-CP-10 are scheduled for demolition as part of this undertaking. Building 06-CP-10 was originally recorded in 2003 during a historical evaluation of four buildings in Area 6. In consultation with the Nevada State Historic Preservation Office, the building was determined individually eligible for inclusion in the NRHP under the Secretary of the Interior’s Significance Criterion A because of its association with nuclear testing and under Significance Criterion C as a distinct type of construction associated with the nuclear industry. Building 06-CP-10A, a munitions magazine, and 06- CP-805, a cap-and-fuse bunker, have been recorded as contributing accessory resources to 06-CP-10. Pursuant to Stipulation III.C.3 of the MOA, this report provides a summary of the historic significance of Building 06-CP-10 and a description of its current condition and accessory resources. In addition, an updated Architectural Resource Assessment (ARA) form with new information and photographs is included in the appendix in fulfillment of Stipulation III.C.2.

54 ENVIRONMENTAL SCIENCES↗

Basic Radiation Theory and Protection [Slides]

Topics for this presentation include isotopes, alpha and beta radiation, x-rays and gamma-rays, neutrons, ionizing radiation, occupational exposure to radiation (CFR limit), radiation exposure amounts, the half-life, radiation protection, inverse square law (1/r 2 ), fission, fusion, and criticality.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental Plan for the Vermiculite Study

Homes in which vermiculite, which can contain asbestos, is present are often deferred under the DOE Weatherization Assistance Program (WAP) because of uncertainty in how to safely weatherize such homes from a client and worker perspective and the potential costs associated with alternative approaches. Recognizing this situation, the Department of Energy (DOE) tasked the Oak Ridge National Laboratory (ORNL) to perform a research project that scientifically identifies the asbestos exposure risks in weatherizing homes with existing vermiculite insulation. Current approaches being used by Grantees and Subgrantees to weatherize homes with existing vermiculite insulation were identified as part of the development of this experimental plan based on a review of Grantee Health and Safety Plans and communications with weatherization program staff from seven states. Other than deferral, these approaches include the following:1.) Abating (i.e., removing) the existing vermiculite using funding sources other than WAP (e.g., state funds, utility funds, the Zonolite Attic Insulation Trust Fund, and possibly homeowner contributions) because abatement is not allowed using WAP funds per Weatherization Program Notice (WPN) 17-7. 2.) Weatherizing the house as normal after testing reveals that the vermiculite contains less than 1% asbestos. 3.) Avoiding areas of the house where vermiculite is installed and weatherizing the remaining areas of the house as normal. 4.) Encapsulating the existing vermiculite insulation in an attic by blowing cellulose or other insulation over it. 5.) Weatherizing the areas of the house where vermiculite is installed using unique/alternative approaches developed specifically for that house. Blower door testing is also impacted by the presence of vermiculite due to the concern of bringing asbestos fibers into the space. Some states address this by performing pressurized blower door tests, whereas other states prohibit blower door testing entirely when vermiculite is present. This research project will focus on gathering data on home occupant and weatherization worker exposures to asbestos before, during, and/or after the weatherization of the homes containing vermiculite insulation using five of the six approaches identified above. Abatement of the existing vermiculite insulation will not be studied because it is not allowed using WAP funding per WPN 17-7 and, thus, is not a sustainable approach for WAP.

36 MATERIALS SCIENCE↗

Less-Than-Lethal Quick Deploy Inflatable Hall/Door Barrier: VISTA Feasibility Study

Physical protection of public buildings has long been a concern of police and security services where a balance of facility security and personnel safety is vital. Due to the nature of public spaces, the use of permanently installed and deploy-on-demand physical barrier systems must be safe for the legitimate occupants and visitors of that space. Such systems must seek to mitigate the personal and organizational consequences of unintentionally seriously injuring or killing an innocent bystander by slamming a heavy, rigid, and quick-deploying barrier into place. Consideration and implementation of less-than-lethal technologies is necessary to reduce risk to visitors and building personnel. One potential barrier solution is a fast-acting, high-strength, composite airbag barrier system for doorways and hallways to quickly deploy a less-than-lethal barrier at entry points as well as isolate intruders who have already gained access. This system is envisioned to be stored within an architecturally attractive selectively frangible shell that could be permanently installed at a facility or installed in remote or temporary locations as dictated by risk. The system would be designed to be activated remotely (hardwired or wireless) from a Central Alarm Station (CAS) or other secure location.

42 ENGINEERING↗

Technology Integration to Gain Commercial Efficiency for the Urban Goods Delivery System, Meet Future Demand for City Passenger and Delivery Load/Unload Spaces, and Reduce Energy Consumption

This three-year project supported by the U.S. Department of Energy Vehicle Technologies Office has the potential to radically improve the urban freight system in ways that help both the public and private sectors. Working from 2018-2021, project researchers at the University of Washington’s Urban Freight Lab and collaborators at the Pacific Northwest National Laboratory have produced key data, tested technologies in complex urban settings, developed a prototype parking availability app, and helped close major knowledge gaps. All the fruits of this project can be harnessed to help cities better understand, support and actively manage truck load/unload operations and their urban freight transport infrastructure. Project learnings and tools can be used to help make goods delivery firms more efficient by reducing miles traveled and the time it takes to complete deliveries, benefitting businesses and residents who rely on the urban freight system for supplies of goods. And, ultimately, these project learnings and tools can be used to make cities more livable by minimizing wasted travel, which, in turn, contributes to reductions in fuel consumption and emissions. Cities today are challenged to effectively and efficiently manage their infrastructure to absorb the impacts of ever-increasing e-commerce-fueled delivery demand. All delivery trucks need to park somewhere to unload and load. Yet today’s delivery drivers have no visibility on available parking until they arrive at a site, which may be full. That means they can wind up cruising for parking, which wastes time and fuel and contributes to congestion. Once drivers do find parking, the faster they can unload at the spot, the faster they free up space for other drivers, helping others avoid circling for parking. This makes the parking space—and thus the greater load/unload network—more productive. To this end, the research team successfully met the project’s three goals, developing and piloting strategies and technologies to: 1. Reduce parking-seeking behavior in the study area by 20%; 2. Reduce parcel truck dwell time (the time a truck spends in a spot to load/unload) in the study area by 30%; 3. Increase curb space, alley space and private loading bay occupancy rates in the study area. The research team met these goals by creating and piloting on Seattle streets OpenPark, a first-of-its-kind real-time and forecasting curb parking app customized for commercial delivery drivers—giving drivers the “missing link” in their commonly used routing tools that tell them how best to get to delivery locations, but not what parking is available to use when they get there. Installing in-ground sensors on commercial vehicle load zones (CVLZs) and passenger load zones (PLZs) in the 10-block study area in Seattle’s downtown neighbourhood of Belltown let researchers glean real-time curb parking data. The research team also met project goals by piloting three parcel lockers in public and private spaces open to any delivery carrier, creating a consolidated delivery hub that lets drivers complete deliveries faster and spend less time parked. Researchers collected and analysed data to produce the first empirical, robust, statistically significant results as to the impact of the lockers, and app, on on-the-ground operations. In addition to collecting and analyzing sensor and other real-time and historical data, researchers rode along with delivery drivers to confirm real-world routing and parking behavior. Researchers also surveyed building managers on their private loading bay operations to understand how to boost usage.

97 MATHEMATICS AND COMPUTING↗

Electronic Structure Theory and Novel Materials

This grant supported research on electronic structure and materials theory, with focus on three main issues: (i) novel techniques to deal with correlation in the electronic ground-state, (ii) topological materials, (iii) the phase diagram of lattice spin models. Regarding (i), we applied to the homogeneous electron liquid an approach that we previously developed in the context of molecular systems. In this scheme the electronic occupation probabilities and the natural spin orbitals are used to construct an approximate two-body density matrix for the electronic ground-state. Regarding (ii) we used standard electronic structure methods based on density functional theory to model topological materials and interpret experimental observations. Finally, regarding (iii) we further developed a numerical approach to compute the renormalized couplings within real space renormalization group theory in the context of lattice spin models. The main findings were the following. (i) We found that with our approximate two-body density matrix, which works well for small molecules, is not sufficiently accurate for condensed phase systems. Missing a systematic way of improving on the adopted approximations, we decided not to pursue this approach. (ii) We performed two studies. In one, we investigated the influence of Te defects on the topological properties of a WTe2 monolayer, finding that while Te vacancies, even in modest concentration, destroy the topological character, Te adatoms do not, consistent with a recent experiment. In another study, we predicted Weyl semimetal character and strong anomalous Hall effect in the Heusler compensated ferrimagnet Ti2MnAl. (iii) We developed a new Monte Carlo method to do real space renormalization group calculations for lattice spin models. We subsequently extended the scheme to deal with lattice spin models in presence of quenched disorder, finding that the approach can distinguish systems with finite and strong disorder. In the finite disorder case, the method allows one to find with good approximation the critical coupling distribution and the critical exponents.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hydrogen Plus Other Alternative Fuels Risk Assessment Models (HyRAM+) Version 4.1 Technical Reference Manual

The HyRAM+ software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen, methane, and propane systems. HyRAM+ is designed to facilitate the use of state-of-the-art models to conduct robust, repeatable assessments of safety, hazards, and risk. HyRAM+ integrates deterministic and probabilistic models for quantifying accident scenarios, predicting physical effects, characterizing hazards (thermal effects from jet fires, overpressure effects from delayed ignition), and assessing impacts on people. HyRAM+ is developed at Sandia National Laboratories to support the development and revision of national and international codes and standards, and to provide developed models in a publicly-accessible toolkit usable by all stakeholders. This document provides a description of the methodology and models contained in HyRAM+ version 4.1. The two most significant changes for HyRAM+ version 4.1 from HyRAM+ version 4.0 are direct incorporation of unconfined overpressure into the QRA calculations and modification of the models for cryogenic liquid flow through an orifice. In QRA mode, the user no longer needs to input peak overpressure and impulse values that were calculated separately; rather, the unconfined overpressure is estimated for the given system inputs, leak size, and occupant location. The orifice flow model now solves for the maximum mass flux through the orifice at constant entropy while conserving energy, which does not require a direct speed of sound calculation. This does not affect the mass flow for all-gaseous releases; the method results in the same speed of sound for choked flow. However, this method does result in a higher (and more realistic) mass flow rate for a given leak size for liquid releases than was previously calculated.

08 HYDROGEN↗

Pathway to Zero Energy Windows: Advancing Technologies and Market Adoption

As of 2021, buildings account for 39.1% of total U.S. primary energy use and 75% of total U.S. electricity use. Much of this energy is used to maintain a comfortable indoor environment. The building envelope consists of transparent and opaque elements that serve as a controllable barrier to help maintain the indoor environment regardless of external conditions. The envelope also allows the exchange of light and air, as well as other transfers with the external environment when it is beneficial for the building occupants. By leveraging desirable external environmental conditions (e.g., fresh air and natural light) and mitigating the influence of undesirable conditions (e.g., moisture, hot or cold temperatures, wind), the building envelope can reduce the need for space conditioning and electric light, and thus reduce energy use associated with lighting and heating, cooling, and ventilation equipment. In turn, high-performance building envelopes can reduce the substantial CO 2 emissions associated with energy use to satisfy heating, cooling, and lighting needs in buildings. The U.S. Department of Energy (DOE) Building Technologies Office's (BTO's) Emerging Technologies program supports R&D for technologies, systems, and software tools that can contribute to reductions in building energy use. Emerging Technologies funding is distributed competitively through solicitations (e.g., Funding Opportunity Announcements and National Lab Calls, which in general are open to applications from industry, academia, national laboratories, and other entities) and other mechanisms. This document focuses on R&D for windows and window system technologies and will provide guidance for BTO's investments in developing the next generation of high-performance, affordable, cost competitive windows, as well as integrated daylighting and shading technologies in partnership with industry and researchers. This document also addresses areas where DOE invests in software and design tools that translate sophisticated and complex physics into easy-to-use energy performance and optimization methods used by industry and other stakeholders for implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation-Based Analysis of Impacts of Reduced Envelope and Duct Air Leakage on Indoor Air Pollutant Concentrations in Occupied Manufactured Homes

This report presents a simulation-based analysis that estimates the magnitude of indoor air pollutant concentration changes that could result from the proposed energy conservation standards. The analysis was conducted for a 1568 ft 2 , double-wide MH with variations in heating and cooling equipment (either furnace + air conditioner or heat pump) and various types of whole-house mechanical ventilation (continuous exhaust fan or central fan integrated supply), in three locations with varying climate conditions: Chicago IL, Fresno, CA; and Houston TX. The simulations tracked four air pollutants that can reach levels exceeding established safe target levels in homes: acrolein, formaldehyde, fine particulate matter (PM 2.5 ), and nitrogen dioxide (NO 2 ). The simulations considered acrolein and formaldehyde emitted from continuous indoor sources; acrolein, NO 2 and PM 2.5 from cooking; PM 2.5 from dispersed occupant activities; and NO 2 and PM 2.5 from outdoors, using historical data to identify typical levels. The impacts in homes operating or not operating whole-house mechanical ventilation equipment, kitchen and bath exhaust fans, and window opening as ventilation approaches were examined.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

U.S. Building Stock Characterization Study: A National Typology for Decarbonizing U.S. Buildings

To support the U.S. Department of Energy's (DOE's) Advanced Building Construction (ABC) Collaborative, the National Renewable Energy Laboratory (NREL) has been tasked with characterizing the U.S. building stock and developing a national typology of buildings. The potential use cases of such a typology are flexible and evolving, but in this initial phase, the primary intention is to help identify technology requirements and engineering solutions for moving the U.S. building stock toward a zero-carbon future by mid-century. This typology will also support the development of appropriate ABC research goals for existing buildings, such as cost targets for new technology development, and in a later phase, the typology can be used to support the implementation of ABC solutions by informing market aggregation and business model development. The ABC Initiative invests in new technologies that enable high building performance, can be deployed quickly with minimal onsite construction time, and are affordable and appealing to building owners, investors, and occupants. Funding awardees use many innovations, including new building materials, 3D printing, offsite manufacturing, robotics, and digital art-to-part. Although the goals of ABC cover a broad range of objectives around energy, comfort, and health, the primary ABC-related application of this national building characterization study is the development of retrofit packages that can be applied to reduce thermal loads in buildings. Retrofit packages will be determined collaboratively by the DOE and the ABC Collaborative. We anticipate a range of upgrade measures covering envelope-, HVAC-, and water-heating-related loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prototype College Building Energy Model: Building Characteristics and Energy Simulation Results

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities and the development of commercial building energy codes and standards, continuous efforts have been made to convert 16 prototype building models, which cover 80% of US commercial building floor space, to OpenStudio prototype buildings. Additionally, the suite of prototype building models was expanded to include the addition of new building prototype models (e.g., courthouse, college building). Multiple sources, including databases, documented projects, and personal communications, were used to define the prototype college building, and a 4-story with 69,063 ft 2 building was considered as the prototype college building to represent an average-sized college building in the United States. To represent realistic occupancy schedules and increase the granularity of information, actual class reservation schedules were collected and used. This report documents the building and system characteristics of the prototype college building model combined with climate-specific and construction vintage–specific requirements for the building envelope and systems from ASHRAE Standard 90.1. The energy simulation results are presented for 4 construction vintages (2004, 2007, 2010, and 2013) and 15 ASHRAE climate zones. The site energy use intensity of the college building was compared with 2012 Commercial Building Energy Consumption Survey (CBECS) and ENERGY STAR data to verify the simulation results. The site energy use intensity of the college building ranged from 60 to 202.4 kBtu/ft 2 , and compared with the energy use intensities of Commercial Building Energy Consumption Survey (122.9 kBtu/ft 2 ) and ENERGY STAR (84.3 kBtu/ft 2 ) data, the prototype college building results are in a reasonable range.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗