Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Studying Short-Range Correlations with the 12 C(e,e'pn) Reaction

We investigated electron-induced two-nucleon emission from carbon with the goal of being sensitive to and studying short-range correlations using the 12 C(e,e'pN) reaction in a triple-coincidence measurement. Two existing high-resolution spectrometers in Hall A at Jefferson Laboratory were used to detect coincident scattered electrons and struck nucleons. A large neutron detector designed and constructed specially for this experiment was used to detect the recoiling neutrons. We performed analysis of the 12 C(e,e'pn) reaction, and made direct observation of short-range correlated n-p pairs. From our analysis we conclude that there are 17.9±4.5 times more n-p short-range correlated pairs than p-p short-range correlated pairs.

43 PARTICLE ACCELERATORS↗

Fission foil detector calibrations with high energy protons

Fission foil detectors (FFD's) are passive devices composed of heavy metal foils in contact with muscovite mica films. The heavy metal nuclei have significant cross sections for fission when irradiated with neutrons and protons. Each isotope is characterized by threshold energies for the fission reactions and particular energy-dependent cross sections. In the FFD's, fission fragments produced by the reactions are emitted from the foils and create latent particle tracks in the adjacent mica films. When the films are processed surface tracks are formed which can be optically counted. The track densities are indications of the fluences and spectra of neutrons and/or protons. In the past, detection efficiencies have been calculated using the low energy neutron calibrated dosimeters and published fission cross sections for neutrons and protons. The problem is that the addition of a large kinetic energy to the (n,nucleus) or (p,nucleus) reaction could increase the energies and ranges of emitted fission fragments and increase the detector sensitivity as compared with lower energy neutron calibrations. High energy calibrations are the only method of resolving the uncertainties in detector efficiencies. At high energies, either proton or neutron calibrations are sufficient since the cross section data show that the proton and neutron fission cross sections are approximately equal. High energy proton beams have been utilized (1.8 and 4.9 GeV, 80 and 140 MeV) for measuring the tracks of fission fragments emitted backward and forward.

Benton, E. V.↗

Planetary Systems Around Neutron Stars

This project was initiated in 1993, about one year after the announcement of two planets around PSR B1257+12. Its goal was to investigate planetary systems around neutron stars using high precision timing of radio pulsars as a tool. A microsecond precision of the pulse timing analysis, which is equivalent to a millimeter-per-second radial velocity resolution, makes it possible to detect asteroid-mass bodies in orbit around pulsars and to study the dynamics of pulsar planetary systems. The project originally consisted of two longterm efforts: (i) routine observations and timing analysis of the millisecond pulsar PSR B1257+12 which was found to be orbited by at least two earth-mass bodies (Wolszczan and Frail, Nature, 355, 145) and (ii) a sensitive all-sky search for millisecond pulsars to detect further examples of neutron stars with planetary systems. In the third year of the project, it was expanded to include long-term timing observations of slow pulsars in search for planetary systems around these younger neutron stars. The instrumentation used to conduct these investigations included the 305-m Arecibo antenna with the Penn State Pulsar Machine (PSPM-1), the 100-m Effelsberg telescope with the local pulse timing hardware, and the 32-m paraboloid of the Torun Centre for Astronomy in Torun, Poland (TCFA) with the PSPM-2, the second pulsar machine built at Penn State. The PI's collaborators included pulsar groups led by D. Backer (Berkeley), R. Foster (NRL), S. Kulkarni (Caltech), J. Taylor (Princeton) and R. Wielebinski (Bonn). One postdoc (Stuart Anderson), one graduate student (Brian Cadwell) and several undergraduates have been engaged in various aspects of research related to this project.

Wolszczan, Alexander↗

Measuring the scintillation decay time for different energy deposited by γ-rays and neutrons in a Cs 2 LiYCl 6 :Ce 3+ detector

In nuclear safeguards and homeland security applications, it is greatly beneficial to simultaneously detect γ-rays, thermal neutrons, and fast neutrons using a single detector with reasonable pulse shape discrimination capability, energy resolution comparable with or even better than NaI(Tl) detectors, and high detection efficiency. Cs 2 LiYCl 6 :Ce 3+ detector (CLYC) scintillation detectors have been proven to be one promising candidate to meet these requirements. In this work, the decay time and fraction of each scintillation component for different energy deposition and incident particle type (γ-ray, thermal neutron, and fast neutron) were investigated based on fitting the PMT anode output with exponential functions. For γ-rays, four components were determined with ultrafast decay time of less than one nanosecond and slow time in the order of magnitude of microsecond. It was found that the dependence on the energy deposited by γ-rays of the fraction as well as the decay time of the three slow components was small. However, significant dependence was observed for the ultrafast component. Two or three components were determined for thermal neutrons and fast neutrons without observing a component with fast decay time. To verify the approach used it was first applied to scintillation pulses induced by γ-rays in a NaI(Tl) detector. We found the results were consistent with well-known data already published in the literature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detection With Rhessi of High Frequency X-ray Oscillations in the Tail of the 2004 Hyperflare From SGR 1806-20

The recent discovery of high frequency oscillations in giant flares from SGR 1806-20 and SGR 1900+14 may be the first direct detection of vibrations in a neutron star crust. If this interpretation is correct it offers a novel means of testing the neutron star equation of state, crustal breaking strain, and magnetic field configuration. Using timing data from RHESSI, we have confirmed the detection of a 92.5 Hz Quasi-Periodic Oscillation (QPO) in the tail of the SGR 1806-20 giant flare. We also find another, stronger, QPO at higher energies, at 626.5 Hz. Both QPOs are visible only at particular (but different) rotational phases, implying an association with a specific area of the neutron star surface or magnetosphere. At lower frequencies we confirm the detection of an 18 Hz QPO, at the same rotational phase as the 92.5 Hz QPO, and report the additional presence of a broad 26 Hz QPO. We are however unable to make a robust confirmation of the presence of a 30 Hz QPO, despite higher count rates. We discuss our results in the light of neutron star vibration models.

Watts, Anna L.↗

Solar neutrons from the impulsive flare on 1982 June 3 at 1143 UT

A transient flux of high energy solar neutrons from 50 MeV to about 1 GeV has been detected by the Gamma Ray Spectrometer (GRS) on the Solar Maximum Mission (SMM) satellite following an intense burst of high energy photons (less than 100 MeV) peaking at 1143:29 UT. The neutrons were also detected by the IGY neutron monitor on Jungfraujoch (Switzerland). In this paper the SMM GRS observations are summarized and compared with the Jungfraujoch neutron monitor data, and both the time dependent neutron flux at the earth and the neutron emission spectrum at the sun are estimated.

Chupp, E. L.↗

MULTI-EPOCH ANALYSIS OF PULSE SHAPES FROM THE NEUTRON STAR SAX J1808.4-3658

The pulse shapes detected during multiple outbursts of SAX J1808.4-3658 are analyzed in order to constrain the neutron star's mass and radius. We use a hot-spot model with a small scattered-light component to jointly fit data from two different epochs, under the restriction that the star's mass and radius and the binary's inclination do not change from epoch to epoch. All other parameters describing the spot location, emissivity, and relative fractions of blackbody to Comptonized radiation are allowed to vary with time. The joint fit of data from the 1998 'slow decay' and the 2002 'end of outburst maximum' epochs using the constraint i < 90 deg. leads to the 3{sigma} confidence constraint on the neutron star mass 0.8 M{sub sun} < M < 1.7 M{sub sun} and equatorial radius 5 km < R < 13 km. Inclinations as low as 41 deg. are allowed. The best-fit models with M>1.0 M{sub sun} from joint fits of the 1998 data with data from other epochs of the 2002 and 2005 outbursts also fall within the same 3{sigma} confidence region. This 3{sigma} confidence region allows a wide variety of hadronic equations of state, in contrast with an earlier analysis by Leahy et al. of only the 1998 outburst data that only allowed for extremely small stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Solution-Grown Rubrene Crystals as Radiation Detecting Devices

There has been increased interest in organic semiconductors over the last decade because of their unique properties. Of these, 5, 6, 11, 12-tetraphenylnaphthacene (rubrene) has generated the most interest because of its high charge carrier mobility. In this paper, large single crystals with a volume of ~1 cm 3 were grown from solution by a temperature reduction technique. The faceted crystals had flat surfaces and cm-scale, visually defect-free areas suitable for physical characterization. X-ray diffraction analysis indicates that solvent does not incorporate into the crystals and photoluminescence spectra are consistent with pristine, high-crystallinity rubrene. Furthermore, the response curve to pulsed optical illumination indicates that the solution grown crystals are of similar quality to those grown by physical vapor transport, albeit larger. The good quality of these crystals in combination with the improvement of electrical contacts by application of conductive polymer on the graphite electrodes have led to the clear observation of alpha particles with these rubrene detectors. Finally, preliminary results with a 252 Cf source generate a small signal with the rubrene detector and may demonstrate that rubrene can also be used for detecting high-energy neutrons.

36 MATERIALS SCIENCE↗

Energy-resolved neutron imaging and diffraction including grain orientation mapping using event camera technology

Time-of-flight neutron diffraction and energy-resolved imaging each provide unique perspectives into material properties. Neutron diffraction is useful for assessing microstructural parameters such as phase composition, texture, and dislocation densities, though it typically provides averaged data over the sampled volume. Energy-resolved imaging, on the other hand, offers both spatial and spectral information by detecting Bragg edges and neutron absorption resonances, which enables detailed mapping of microstructure and isotopic composition. When combined, these techniques have the potential to enrich our understanding of material behavior across different scales, enhancing our understanding of complex materials. Traditionally, these modalities are conducted on separate instruments, which is time-consuming and poses challenges for data integration. Here, we report the integration of the LumaCam, an event-mode energy-resolved neutron imaging camera with the HIPPO time-of-flight diffractometer at LANSCE. This integration enables simultaneous diffraction and imaging across the full spectrum, with analysis optimized for diffraction and Bragg-edge imaging in the thermal range (0.45–10 Å) and resonance imaging in the epithermal range (0.5–3000 eV), facilitating comprehensive multi-modal analysis. We demonstrate its capabilities through case studies, including spatial mapping of grain orientations in a steel sample and accurate thickness estimations for irregular samples including a depleted uranium cylinder and a natural silver-containing mineral specimen. The combined setup enhances real-time sample alignment and provides comprehensive data for crystal structure, texture, and isotopic composition analysis. This approach opens new possibilities for advanced applications in nuclear engineering, archaeology, and materials science.

36 MATERIALS SCIENCE↗

Covariance Spectroscopy for Fissile Material Detection

Nuclear fission produces multiple prompt neutrons and gammas at each fission event. The resulting daughter nuclei continue to emit delayed radiation as neutrons boil off, beta decay occurs, etc. All of the radiations are causally connected, and therefore correlated. The correlations are generally positive, but when different decay channels compete, so that some radiations tend to exclude others, negative correlations could also be observed. A similar problem of reduced complexity is that of cascades radiation, whereby a simple radioactive decay produces two or more correlated gamma rays at each decay. Covariance is the usual means for measuring correlation, and techniques of covariance mapping may be useful to produce distinct signatures of special nuclear materials (SNM). A covariance measurement can also be used to filter data streams because uncorrelated signals are largely rejected. The technique is generally more effective than a coincidence measurement. In this poster, we concentrate on cascades and the covariance filtering problem.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of {sup 6}LiF:ZnS(Ag) Scintillator Light Yield Using Geant4

Neutrons provide an effective tool to probe materials structure. Neutron diffraction is a method to determine the atomic and magnetic structure of a material based on neutron scattering. By this method a collimated incident beam of thermal neutrons heat the examined sample and based on the obtained diffraction pattern information on the structure of the material is provided. Research for developing a novel cold neutron detector for Chromatic Analysis Neutron Diffractometer Or Reflectometer (CANDOR) is underway at the NIST center for neutron research. The system unique design is aimed to provide over ten times fold faster analysis of materials than conventional system. In order to achieve the fast analysis a large number of neutron detectors is required. A key design constraint for this detector is the thickness of the neutron sensitive element. This is met using {sup 6}LiF:ZnS(Ag) scintillation material with embedded wavelength shifting (WLS) fibers conducting scintillation light to silicon photomultiplier photo-sensors. The detector sensitivity is determined by both the neutron capture probability ({sup 6}Li density) and the detectable light output produced by the ZnS(Ag) ionization, the latter of which is hindered by the fluorescence absorption of the scintillation light by the ZnS. Tradeoffs between the neutron capture probability, stimulated light production and light attenuation for determining the optimal stoichiometry of the {sup 6}LiF and ZnS(Ag) as well as the volume ratio of scintillator and fiber. Simulations performed using the GEANT4 Monte Carlo package were made in order to optimize the detector design. GEANT4 enables the investigation of the neutron interaction with the detector, the ionization process and the light transfer process following the nuclear process. The series of conversions required for this detector were modelled: - A cold neutron enters the sensor and is captured by {sup 6}Li in the scintillator mixture ({sup 6}Li (n,α) {sup 3}H reaction). The study of investigating the capture process probability for neutron energy of 5.1 meV to 2.27 meV (4 - 6 A) is presented. - Alpha particles and tritons travel for a few microns in the scintillation material (α ∼0.007 mm, T ∼0.04 mm) losing energy and ionizing the ZnS. The mean free path of the two particles in each of the component materials and the complete compound was investigated. - The ionization of the ZnS(Ag) scintillation material produces blue light photons with luminescence wavelength of 450 nm. The amount of light output produced for different grain sizes of ZnS is discussed. - A large portion of the scintillation photons are reabsorbed during their passage through the scintillation material. - The blue photons that reach the WLS fibers are absorbed by fluorescent dye and are re-emitted as green photons, conducted by the fiber to the SiPM photo-sensor. This work presents the CANDOR unique design and its design constrains, the results measured by the ultra-thin {sup 6}LiF:ZnS(Ag)-based neutron detector versus the simulation results for several binder concentrations. The light measurement attenuation results along with the measured stopping power were utilized to predict the sensitivity results of configuration with different ZnS grain size, weight ratios and fibers geometry (number and location). The simulations enable to optimize the final sensor design. This design successfully achieved both the high gamma rejection with a sensitive and accurate neutron event detection of 80 percent. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative comparison between PGNAA measurements and MCNP calculations in view of the characterization of radioactive wastes in Germany and France

The Forschungszentrum Juelich GmbH (FZJ), together with the Aachen University Rheinisch-Westfaelische Technische Hochschule (RWTH) and the French Alternative Energies and Atomic Energy Commission (CEA Cadarache) are involved in a cooperation aiming at characterizing toxic and reactive elements in radioactive waste packages by means of Prompt Gamma Neutron Activation Analysis (PGNAA). The French and German waste management agencies have indeed defined acceptability limits concerning these elements in view of their projected geological repositories. A first measurement campaign was performed in the new Prompt Gamma Neutron Activation Analysis (PGNAA) facility called MEDINA, at FZJ, to assess the capture gamma-ray signatures of some elements of interest in large samples up to waste drums with a volume of 200 liter. MEDINA is the acronym for Multi Element Detection based on Instrumental Neutron Activation. This paper presents MCNP calculations of the MEDINA facility and quantitative comparison between measurement and simulation. Passive gamma-ray spectra acquired with a high purity germanium detector and calibration sources are used to qualify the numerical model of the crystal. Active PGNAA spectra of a sodium chloride sample measured with MEDINA then allow for qualifying the global numerical model of the measurement cell. Chlorine indeed constitutes a usual reference with reliable capture gamma-ray production data. The goal is to characterize the entire simulation protocol (geometrical model, nuclear data, and postprocessing tools) which will be used for current measurement interpretation, extrapolation of the performances to other types of waste packages or other applications, as well as for the study of future PGNAA facilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Large Searching for Higher Dimensional Gravity with Neutron Experiments

N-dimensional gravity is analized in the context of recent work on 'large' supplementary dimensions. A simple derivation of the compactification radii for additional dimensions in the universe is made, as a function of the Planck and the electro-weak scales. It is argued that the modified gravitational force would give rise to effects that might be within the detection range of dedicated neutron experiments. An analysis suggests that neutron scattering off atomic nuclei with null spin may provide an experimental test for these ideas.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision determination of absolute neutron flux

A technique for establishing the total neutron rate of a highly-collimated monochromatic cold neutron beam was demonstrated using an alpha–gamma counter. The method involves only the counting of measured rates and is independent of neutron cross sections, decay chain branching ratios, and neutron beam energy. For the measurement, a target of 10 B-enriched boron carbide totally absorbed the neutrons in a monochromatic beam, and the rate of absorbed neutrons was determined by counting 478 keV gamma rays from neutron capture on 10 B with calibrated high-purity germanium detectors. A second measurement based on Bragg diffraction from a perfect silicon crystal was performed to determine the mean de Broglie wavelength of the beam to a precision of 0.024%. With these measurements, the detection efficiency of a neutron monitor based on neutron absorption on 6 Li was determined to an overall uncertainty of 0.058%. We discuss the principle of the alpha–gamma method and present details of how the measurement was performed including the systematic effects. We further describe how this method may be used for applications in neutron dosimetry and metrology, fundamental neutron physics, and neutron cross section measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2011 U.S. National School on Neutron and X-ray Scattering

The 13th annual U.S. National School on Neutron and X-ray Scattering was held June 11 to 25, 2011, at both Oak Ridge and Argonne National Laboratories. This school brought together 65 early career graduate students from 56 different universities in the US and provided them with a broad introduction to the techniques available at the major large-scale neutron and synchrotron x-ray facilities. This school is focused primarily on techniques relevant to the physical sciences, but also touches on cross-disciplinary bio-related scattering measurements. During the school, students received lectures by over 30 researchers from academia, industry, and national laboratories and participated in a number of short demonstration experiments at Argonne's Advanced Photon Source (APS) and Oak Ridge's Spallation neutron Source (SNS) and High Flux Isotope Reactor (HFIR) facilities to get hands-on experience in using neutron and synchrotron sources. The first week of this year's school was held at Oak Ridge National Lab, where Lab director Thom Mason welcomed the students and provided a shitorical perspective of the neutron and x-ray facilities both at Oak Ridge and Argonne. The first few days of the school were dedicated to lectures laying out the basics of scattering theory and the differences and complementarity between the neutron and x-ray probes given by Sunil Sinha. Jack Carpenter provided an introduction into how neutrons are generated and detected. After this basic introduction, the students received lectures each morning on specific techniques and conducted demonstration experiments each afternoon on one of 15 different instruments at either the SNS or HFIR. Some of the topics covered during this week of the school included inelastic neutron scattering by Bruce Gaulin, x-ray and neutron reflectivity by Chuck Majkrazak, small-angle scattering by Volker Urban, powder diffraction by Ashfia Huq and diffuse scattering by Gene Ice.

43 PARTICLE ACCELERATORS↗

Special Nuclear Material Detection and Monitoring by Environmental Activation Products Detection

Through a series of measurements with a high purity germanium detector, we have established that the past presence of neutron emitting material can be detected by the decay of activation products in aluminum containers, tungsten shielding, and concrete floors even several days after last exposure. The time since last exposure can also be estimated by the gamma-ray detection rate. These findings may lead to interesting new CONOPS in the detection of illicit SNM or the verification of the absence (or presence) of SNM containing objects in facilities and/or transit even after the material has been removed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Photofission Validation Measurements for Active Interrogation Standards

Executive Summary PNNL has been developing technical standards for the detection of special nuclear material (SNM) in cargo containers using active interrogation approaches. Since the use of kilogram-scale quantities of SNM is impractical for standards testing, the work focused on designing surrogates that provided similar signature as the SNM. There are many active interrogation approaches to detect SNM; the standards development considered photofission, differential die-away and nuclear resonance fluorescence. Of these approaches, photofission currently carries the most interest. However, uncertainties in the photofission cross sections are as large as 50%, so that validation measurements are necessary to provide confidence that the surrogate will perform similarly to the SNM. This document describes approaches for conducting those validation measurements as well as provides a rough order-of-magnitude cost estimate for performing them. Photofission provides many observables for the detection of SNM. The standards development considered prompt neutrons, delayed neutrons and delayed gamma rays as possible detected particles. The surrogates, which consist primarily of depleted uranium (DU), were designed to reproduce the strength of these particles for a targeted quantity of 2 kg of HEU. Different surrogates are required for different measurement approaches because of the difference in cross section between 235 U and 238 U. For the standards validations, the relative strength of the detected particles for HEU and DU must be measured. To avoid measurements with kilogram-sized SNM, the validation approach is focused on two comparisons. In the first comparison, the relative rates for approximately 10 g samples of DU and HEU will be measured. This comparison will provide the basis for validating the relative strength of the detected particles for HEU and DU. In the second comparison, the relative rates for the approximately 10 g and 1 kg sample of DU will be measured. This comparison will enable the validation of secondary processes that occur after photofission that impact the measurement for kilogram-scale samples. For instance, for 2 kg of HEU, as much as 50% of the fission induced in the sample is induced from fission neutrons generated through photofission. There is a limited range of facilities in the U.S. that have both the necessary accelerator capability and the ability and willingness to handle SNM. Two such facilities, the Idaho Accelerator Center at Idaho State University and the Nuclear Engineering Program at the University of Michigan, have both expressed an interest in participating in such measurements. Both would need to amend their licensing to handle the 10 g of HEU proposed for these measurements. The rough order-of-magnitude cost estimate for all three validation measurements is $1.1M, spread over three years. Each of the three measurements could be performed separately, at approximately one-third of that cost. There are a number of critical assumptions in these cost estimate that will need to be confirmed before a more reliable cost estimate can be established. PNNL will manage the effort to ensure that the overall objective of the validation measurements can be achieved and will fabricate the 10 g samples of HEU and DU. Most the labor for the measurements will be provided by two collaborating universities as research opportunities for students. The successful completion of these validation measurements will reduce the uncertainties in the proposed standards from about 50% to 5%. The measurements would also provide some much-needed nuclear data on photofission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Maximum Likelihood Source Localization Using Elpasolite as a Dual Gamma Neutron Directional Detector

The problem of accurately detecting extremely low levels of nuclear radiation is rapidly increasing in importance in nuclear counter-proliferation, verification, and environmental and waste management. Because the 239Pu gamma signature may be weak, for instance, even when compared to the natural terrestrial background, coincidence counting with the 239Pu neutron signature may improve overall 239Pu detection sensitivity. However, systems with sufficient multiple-particle detectors require demonstration that the increased sensitivity be sufficiently high to overcome added cost and weight. We report the results of measurements and calculations to determine sensitivity that can be gained in detecting low levels of nuclear radiation from use of a relatively new detector technology based on elpasolite crystals. We have performed investigations exploring cerium (Ce3+)-doped elpasolites Cs2LiYCl6:Ce3+0.5% (CLYC) and Cs2LiLa(Br6)90%(Cl6)10%:Ce3+0.5% (CLLBC:Ce). These materials can provide energy resolution (r(E) = 2.35σ(E)/E) as good as 2.9% at 662 keV (FWHM). The crystals show an excellent neutron and gamma radiation response. The goals of the investigation were to set up the neutron/gamma pulse shape discrimination electronics for elpasolite detectors; perform limited static source benchmarking, testing, and evaluation to validate system performance; and explore application of a maximum likelihood algorithm for source location. Data were measured and processed through a maximum likelihood estimation algorithm, providing a direction to the radioactive source for each individual position. The estimated directions were good representations for the actual directions to the radioactive source. This paper summarizes the maximum likelihood results for our elpasolite system.

maximum likelihood, radiation detectors, neutron d↗