Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Characterization of melted fuel by neutron resonance spectroscopy

Neutrons can be used as a tool to study properties of materials and objects. An evolving activity in this field focusses on neutron induced reaction cross sections. The probability that a neutron interacts with nuclei strongly depends on the energy of the neutron. The cross sections reveal the presence of resonance structures, the energy and width of which are isotope specific. As such, these resonance structures can be used as fingerprints to determine the elemental and isotopic composition of materials and objects. They are the basis of two analytical methods which have been developed at Institute for Reference Materials and Measurements of the European Commission's Joint Research Centre (EC-JRC-IRMM): Neutron Resonance Capture Analysis (NRCA) and Neutron Resonance Transmission Analysis (NRTA). The first technique is based on the detection of gamma rays emitted during a neutron capture reaction in the sample being studied; the latter determines the fraction of neutrons transmitted through a sample positioned in a neutron beam. In the past both techniques have been applied to determine the composition of archaeological objects and to characterize nuclear reference materials. More recently a combination of NRTA and NRCA is being studied as a non-destructive method to determine the heavy metal content of particle-like debris of melted fuel that is formed in severe nuclear accidents such as the one which occurred at the Fukushima Daiichi nuclear power plant in Japan. This study is part of a collaboration between the Japan Atomic Energy Agency (JAEA) and ECJRC- IRMM and is a spin-off from the core activity of IRMM, i.e. the production of nuclear data for nuclear technology applications. This contribution focusses on a newly developed NRTA measurement station that has been set up recently at one of the flight paths of the neutron time-of-flight facility GELINA at the EC-JRC-IRMM. The basic principles of NRTA and first results of measurements at the new set up will be discussed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring the Density of Different Materials by Using the Collimated Fast Neutron Beam

It was demonstrated in the previous work that various threat materials could be detected inside the sea going cargo container by measuring the three variables, carbon and oxygen concentration and density of investigated material. Density was determined by measuring transmitted neutrons, which is not always practical in terms of setting up the instrument geometry. In order to enable more geometry flexibility, we have investigated the possibility of using the scattered neutrons in cargo material identification. For that purpose, the densities of different materials were measured depending on the position of neutron detectors and neutron generator with respect to the target position. One neutron detector was put above the target, one behind and one in front of the target, above the neutron generator. It was shown that all three positions of neutron detectors can be successfully used to measure the target density, but only if the detected neutrons are successfully discriminated from the gamma rays. Although the associated alpha particle technique/associate particle imaging (API) was used to discriminate the neutrons from the gamma rays, it is believed that the same results would be obtained by using the pulse shape discrimination method. In that way API technique can be avoided and the neutron generator which produces much higher beam intensity than 10{sup 8} n/s can be used. (authors)

36 MATERIALS SCIENCE↗

Calibration of ITER Instant Power Neutron Monitors: Recommended Scenario of Experiments at the Reactor

Instant power is a key parameter of the ITER. Its monitoring with an accuracy of a few percent is an urgent and challenging aspect of neutron diagnostics. In a series of works published in Problems of Atomic Science and Technology, Series: Thermonuclear Fusion under a common title, the step-by-step neutronics analysis was given to substantiate a calibration technique for the DT and DD modes of the ITER. A Gauss quadrature scheme, optimal for processing “expensive” experiments, is used for numerical integration of {sup 235}U and {sup 238}U detector responses to the point sources of 14-MeV neutrons. This approach allows controlling the integration accuracy in relation to the number of coordinate mesh points and thus minimizing the number of irradiations at the given uncertainty of the full monitor response. In the previous works, responses of the divertor and blanket monitors to the isotropic point sources of DT and DD neutrons in the plasma profile and to the models of real sources were calculated within the ITER model using the MCNP code. The neutronics analyses have allowed formulating the basic principles of calibration that are optimal for having the maximum accuracy at the minimum duration of in situ experiments at the reactor. In this work, scenarios of the preliminary and basic experimental ITER runs are suggested on the basis of those principles. It is proposed to calibrate the monitors only with DT neutrons and use correction factors to the DT mode calibration for the DD mode. It is reasonable to perform full calibration only with {sup 235}U chambers and calibrate {sup 238}U chambers by responses of the {sup 235}U chambers during reactor operation (cross-calibration). The divertor monitor can be calibrated using both direct measurement of responses at the Gauss positions of a point source and simplified techniques based on the concepts of equivalent ring sources and inverse response distributions, which will considerably reduce the amount of measurements. It is shown that the monitor based on the average responses of the horizontal and vertical neutron chambers remains spatially stable as the source moves and can be used in addition to the staff monitor at neutron fluxes in the detectors four orders of magnitude lower than on the first wall, where staff detectors are located. Owing to low background, detectors of neutron chambers do not need calibration in the reactor because it is actually determination of the absolute detector efficiency for 14-MeV neutrons, which is a routine out-of-reactor procedure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Basics of Neutrons for First Responders

These are slides from a presentation on the basics of neutrons. A few topics covered are: common origins of terrestrial neutron radiation, neutron sources, neutron energy, interactions, detecting neutrons, gammas from neutron interactions, neutron signatures in gamma-ray spectra, neutrons and NaI, neutron fluence to dose (msV), instruments' response to neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural Aspects of Neutron Survival Probabilities

The neutron survival probability (and related quantities including probabilities of extinction and initiation) is a central element of the broader stochastic theory of neutron populations and finds application in fields including reactor start-up, analysis of reactor power bursts and criticality accidents, and safeguards. In a full neutron transport formulation, the equation governing the single-neutron survival probability is a backward or adjoint-like integro-partial differential equation with the added complexity of being highly nonlinear. Analogous formulations of this equation exist in the context of many approximate theories of neutron transport, with the point kinetics formulation having received significant theoretical attention since the 1940s. This work continues this tradition by providing a novel analysis of the single-neutron survival probability equation using the tools of boundary layer theory. The analysis reveals that the “fully dynamic” solution of the single-neutron survival probability equation—and some key probability distributions derived from it—may be cast as a singular perturbation around the underlying quasi-static single-neutron probability of initiation. In this perturbation solution, the expansion parameter is the ratio of the neutron generation time to a macroscopic time scale characterizing the overall system evolution; this interpretation illuminates some of the fundamental structural aspects of neutron survival phenomena.

97 MATHEMATICS AND COMPUTING↗

An Analysis Technique for Active Neutron Multiplicity Measurements Based on First Principles

Passive neutron multiplicity counting is commonly used to quantify the total mass of plutonium in a sample, without prior knowledge of the sample geometry. However, passive neutron counting is less applicable to uranium measurements due to the low spontaneous fission rates of uranium. Active neutron multiplicity measurements are therefore used to determine the {sup 235}U mass in a sample. Unfortunately, there are still additional challenges to overcome for uranium measurements, such as the coupling of the active source and the uranium sample. Techniques, such as the coupling method, have been developed to help reduce the dependence of calibration curves for active measurements on uranium samples; although, they still require similar geometry known standards. An advanced active neutron multiplicity measurement method is being developed by Texas A&M University, in collaboration with Los Alamos National Laboratory (LANL) in an attempt to overcome the calibration curve requirements. This method can be used to quantify the {sup 235}U mass in a sample containing uranium without using calibration curves. Furthermore, this method is based on existing detectors and nondestructive assay (NDA) systems, such as the LANL Epithermal Neutron Multiplicity Counter (ENMC). This method uses an inexpensive boron carbide liner to shield the uranium sample from thermal and epithermal neutrons while allowing fast neutrons to reach the sample. Due to the relatively low and constant fission and absorption energy dependent cross-sections at high neutron energies for uranium isotopes, fast neutrons can penetrate the sample without significant attenuation. Fast neutron interrogation therefore creates a homogeneous fission rate in the sample, allowing for first principle methods to be used to determine the {sup 235}U mass in the sample. This paper discusses the measurement method concept and development, including measurements and simulations performed to date, as well as the potential limitations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nodal weighting factor method for ex-core fast neutron fluence evaluation

The nodal weighting factor method is developed for evaluating ex-core fast neutron flux in a nuclear reactor by utilizing adjoint neutron flux, a fictitious unit detector cross section for neutron energy above 1 or 0.1 MeV, the unit fission source, and relative assembly nodal powers. The method determines each nodal weighting factor for ex-core neutron fast flux evaluation by solving the steady-state adjoint neutron transport equation with a fictitious unit detector cross section for neutron energy above 1 or 0.1 MeV as the adjoint source, by integrating the unit fission source with a typical fission spectrum to the solved adjoint flux over all energies, all angles and given nodal volume, and by dividing it with the sum of all nodal weighting factors, which is a normalization factor. Then, the fast neutron flux can be obtained by summing the various relative nodal powers times the corresponding nodal weighting factors of the adjacent significantly contributed peripheral assembly nodes and times a proper fast neutron attenuation coefficient over an operating period. A generic set of nodal weighting factors can be used to evaluate neutron fluence at the same location for similar core design and fuel cycles, but the set of nodal weighting factors needs to be re-calibrated for a transition-fuel-cycle. This newly developed nodal weighting factor method should be a useful and simplified tool for evaluating fast neutron fluence at selected locations of interest in ex-core components of contemporary nuclear power reactors. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Accelerator shield design of KIPT neutron source facility

Argonne National Laboratory (ANL) of the United States and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have been collaborating on the design development of a neutron source facility at KIPT utilizing an electron-accelerator-driven subcritical assembly. Electron beam power is 100 kW, using 100 MeV electrons. The facility is designed to perform basic and applied nuclear research, produce medical isotopes, and train young nuclear specialists. The biological shield of the accelerator building is designed to reduce the biological dose to less than 0.5-mrem/hr during operation. The main source of the biological dose is the photons and the neutrons generated by interactions of leaked electrons from the electron gun and accelerator sections with the surrounding concrete and accelerator materials. The Monte Carlo code MCNPX serves as the calculation tool for the shield design, due to its capability to transport electrons, photons, and neutrons coupled problems. The direct photon dose can be tallied by MCNPX calculation, starting with the leaked electrons. However, it is difficult to accurately tally the neutron dose directly from the leaked electrons. The neutron yield per electron from the interactions with the surrounding components is less than 0.01 neutron per electron. This causes difficulties for Monte Carlo analyses and consumes tremendous computation time for tallying with acceptable statistics the neutron dose outside the shield boundary. To avoid these difficulties, the SOURCE and TALLYX user subroutines of MCNPX were developed for the study. The generated neutrons are banked, together with all related parameters, for a subsequent MCNPX calculation to obtain the neutron and secondary photon doses. The weight windows variance reduction technique is utilized for both neutron and photon dose calculations. Two shielding materials, i.e., heavy concrete and ordinary concrete, were considered for the shield design. The main goal is to maintain the total dose outside the shield boundary at less than 0.5-mrem/hr. The shield configuration and parameters of the accelerator building have been determined and are presented in this paper. (authors)

43 PARTICLE ACCELERATORS↗

Comparison of MCNP6 and experimental results for neutron counts, Rossi-{alpha}, and Feynman-{alpha} distributions

MCNP6, the general-purpose Monte Carlo N-Particle code, has the capability to perform time-dependent calculations by tracking the time interval between successive events of the neutron random walk. In fixed-source calculations for a subcritical assembly, the zero time value is assigned at the moment the neutron is emitted by the external neutron source. The PTRAC and F8 cards of MCNP allow to tally the time when a neutron is captured by {sup 3}He(n, p) reactions in the neutron detector. From this information, it is possible to build three different time distributions: neutron counts, Rossi-{alpha}, and Feynman-{alpha}. The neutron counts time distribution represents the number of neutrons captured as a function of time. The Rossi-a distribution represents the number of neutron pairs captured as a function of the time interval between two capture events. The Feynman-a distribution represents the variance-to-mean ratio, minus one, of the neutron counts array as a function of a fixed time interval. The MCNP6 results for these three time distributions have been compared with the experimental data of the YALINA Thermal facility and have been found to be in quite good agreement. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Neutron Fluence and Energy Reconstruction with the LNE-IRSN/MIMAC Recoil Detector MicroTPC at 27 keV

The French Institute for Radiation protection and Nuclear Safety (IRSN), designated by the French Metrology Institute (LNE) for neutron metrology, is developing a time projection chamber using a Micromegas anode: microTPC. This work is carried out in collaboration with the Laboratory of Subatomic Physics and Cosmology (LPSC). The aim is to characterize the energy distribution of neutron fluence in the energy range 8 keV - 5 MeV with a primary procedure. The time projection chambers are gaseous detectors able to measure charged particles energy and to reconstruct their track if a pixelated anode is used. In our case, the gas is used as a (n, p) converter in order to detect neutrons down to few keV. Coming from elastic collisions with neutrons, recoil protons lose a part of their kinetic energy by ionizing the gas. The ionization electrons are drifted toward a pixelated anode (2D projection), read at 50 MHz by a self-triggered electronic system to obtain the third track dimension. The neutron energy is reconstructed event by event thanks to proton scattering angle and proton energy measurements. The scattering angle is deduced from the 3D track. The proton energy is obtained by charge collection measurements, knowing the ionization quenching factor (i.e. the part of proton kinetic energy lost by ionizing the gas). The fluence is calculated thanks to the detected events number and the simulation of the detector response. The μTPC is a new reliable detector able to measure energy distribution of the neutron fluence without unfolding procedure or prior neutron calibration contrary to usual gaseous counters. The microTPC is still being developed and measurements have been carried out at the AMANDE facility, with neutrons energies going from 8 keV to 565 keV. After the context and the μ-TPC working principle presentation, measurements of the neutron energy and fluence at 27 keV and 144 keV are shown and compared to the complete detector response simulation. This work shows the first direct reconstruction of neutron energy and fluence, simultaneously, at 27.2 keV in a continuous irradiation mode. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of Neutron Importance Distribution in {sup 235}U Fast Critical Reactor

The reactor physics related integral experiments are significant to criticality safety analysis and the design of the next generation nuclear system. Measurements of parameters such as prompt neutron decay constant α, prompt neutron generation time Λ, effective delayed neutron fraction β{sub eff}, neutron importance distribution, etc., can provide data for the verification of calculation methods, computer codes and cross-section data in criticality safety analysis and test the design of new reactors. Among these parameters, neutron importance distribution has its unique value. Beside verification and validation of nuclear data, computer codes, and simulation methods, the experimental results of neutron importance distribution are also useful to the correcting of the spatial effects in Rossi-α measurement, which is based on point-reactor neutron kinetics. The relative neutron importance distribution experiments were performed on the {sup 235}U fast critical reactor of China Academy of Engineering Physics (CAEP). The key experimental objective was to obtain the importance distribution data for nuclear data validation and criticality safety analysis. We demonstrate in this paper the experiment and the data analysis. {sup 252}Cf neutron importance spatial distributions in the diametral hole of a depleted uranium reflected {sup 235}U fast critical reactor were measured. The evaluated uncertainties of the experiment data were varying with the source location but within 1.5% ranges in all. The experiment results can provide useful data for applications like nuclear data validation and the determination of rectification factor R of Rossi-a measurements. However, the experimental uncertainties are not satisfying and can be further reduced by using a {sup 252}Cf source with much higher intensity, recording more precisely the absolute position of the neutron source, and carrying out the experiment in more shallow subcritical states in which the system multiplication is larger. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characterization Techniques for LiInSe{sub 2} Semiconducting Neutron Detector - Paper 55

As the world supply of helium continues to dwindle, alternatives to neutron detection have been a key focus area of radiation detection research. Solid-state neutron detectors are one possible alternative to the {sup 3}He detectors currently used for neutron detection when large detector areas are not required. Although {sup 6}Li and {sup 10}B are both also commonly used for neutron detection, neither has as high of a thermal cross section as {sup 3}He. The thermal cross sections for {sup 6}Li, {sup 10}B, and {sup 3}He are, respectively, 940 barns, 3840 barns, and 5330 barns. Both boron and helium are used in a gaseous form for neutron detection; however, there is no suitable gaseous form of lithium for neutron detection. Lithium is instead utilized in solid or liquid compounds for neutron detection. In this context, one area of interest is in the development of ternary A{sup I}B{sup III}C{sup IV} semiconductors comprised of isotopically-enriched lithium. Single crystal samples are being prepared through collaboration with the Y12 National Security Complex. This research focuses on the characterization of {sup 6}LiInSe{sub 2} (LISe) crystals, as well as on the development of prototype systems to assess the viability of using LISe crystals as a thermal neutron detector. Data to be obtained will provide previously untested physical parameters to facilitate growth optimization. Eventually, the refined crystals will be developed into solid-state, position-sensitive pixel detectors used for neutron imaging, among a wide array of possible applications including nuclear forensics. For the most part, the research team has been focused on mastering the detector fabrication processes, response tests on the first two batches of crystal samples, and the design of the first iteration detection system (Fig. 2). Response tests using alphas and neutrons have shown sensitivity to both particles. The first iteration detection system developed utilizes a 3-stage filter ladder of resistors and capacitors, similar to an ORTEC 142PC Preamplifier. Ideally, this ladder will reduce the noise associated with the high voltage power supply. The preamplifier is AC coupled to improve its counting rate capability (saturation), and critical components are on insulated posts. The custom circuit is housed in an aluminum box, and initial testing of the circuit has shown expected results. Investigation into further noise reduction is underway and will be the focus of the presented results. Upon completion and successful testing of the final detection system design, further development in spatial resolution and gamma/neutron discrimination will continue. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Fast Measurement System of Neutron Emission Profile Using a Digital Signal Processing Technique in JT-60U

Neutron emission profiles are routinely measured in JT-60U Tokamak. Stinbene neuron detectors (SNDs), which combine a Stilbene organic crystal scintillation detector (Stilbene detector) with an analog neutron-gamma pulse shape discrimination (PSD) circuit, have been used to measure neutron flux efficiently. Although the SND has many advantages as a neutron detector, the maximum count rate is limited up to {approx}1x 10{sup 5} counts/s due to the dead time of the analog PSD circuit. To overcome this issue, a digital signal processing (DSP) system using a Flash-ADC has been developed. In this system, anode signals from the photomultiplier of the Stilbene detector are fed to the Flash ADC and digitized. Then, the PSD between neutrons and gamma-rays are performed using software. The photomultiplier tube is also modified to suppress and correct gain fluctuation of the photomultiplier. The DSP system has been installed in the center channel of the vertical neutron collimator system in JT-60U and applied to measurements of neutron flux in JT-60U experiments. Neutron flux are successfully measured with count rate up to {approx}1x 10{sup 6} counts/s without the effect of pile up of detected pulses. The performance of the DSP system as a neutron detector is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High Intensity, Pulsed, D-D Neutron Generator

Single ion-beam RF-plasma neutron generators are presented as a laboratory source of intense neutrons. The continuous and pulsed operations of such a neutron generator using the deuterium-deuterium fusion reaction are reported. The neutron beam can be pulsed by switching the RF plasma and/or a gate electrode. These generators are actively vacuum pumped so that a continuous supply of deuterium gas is present for the production of ions and neutrons. This contributes to the generator's long life. These single-beam generators are capable of producing up to 10{sup 10} n/s. Previously, Adelphi and LBNL have demonstrated these generators' applications in fast neutron radiography, Prompt Gamma Neutron Activation Analysis (PGNAA) and Neutron Activation Analysis (NAA). Together with an inexpensive compact moderator, these high-output neutron generators extend useful applications to home laboratory operations.

43 PARTICLE ACCELERATORS↗

Neutron flux reduction programs for reactor pressure vessel

The objective of this work is to implement various fast neutron flux reduction programs on the belt-line region of the reactor pressure vessel to reduce the increasing rate of reference temperature for pressurized thermal shock (RT PTS) for Korea Nuclear Unit 1. A pressurized thermal shock (PTS) event is an event or transient in pressurized water reactors (PWRs) causing severe overcooling (thermal shock) concurrent with or followed by significant pressure in the reactor vessel. A PTS concern arises if one of these transients acts in the belt-line region of a reactor vessel where a reduced fracture resistance exists because of neutron irradiation. Generally, the RT PTS value is continuously increasing according to the fast neutron irradiation during the reactor operation, and it can reach the screening criterion prior to the expiration of the operating license. To reduce the increasing rate of RT PTS, various neutron flux reduction programs can be implemented, which are focused on license renewal. In this paper, neutron flux reduction programs, such as low leakage loading pattern strategy, loading of neutron absorber rods, and dummy fuel assembly loading are considered for Korea Nuclear Unit 1, of which the RT PTS value of the leading material (circumferential weld) is going to reach the screening criterion in the near future. To evaluate the effects of the neutron flux reduction programs, plant and cycle specific forward neutron transport calculations for the various neutron flux reduction programs were carried out. For the analysis, all transport calculations were carried out by using the DORT 3.1 discrete ordinate code and BUGLE-96 cross-section library. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Response of Ferroelectric Polyvinylidene Fluoride under Pulsed Fast Neutron Irradiation

Because the spontaneous polarization of a ferroelectric material is a function of temperature, heating or cooling it slightly will cause bound charge to accumulate on faces normal to the polarization, and the phenomenon is called pyroelectric effect. The pyroelectric detectors can uses pulsed gamma rays or neutrons as the heat source, and they do not require external power supply units and have a high radiation stability. Pb(Zr, Ti)O{sub 3}-based ceramics are widely used ferroelectrics and have a relatively high density of about 7.8 g/cm{sup 3}, which is promising for gamma-ray detection. To develop a pyroelectric thermal neutron detector, E.A. de Souza and L.P. Geraldo et al. prepared a layer of neutron converter on the surface of Pb(Zr, Ti)O{sub 3} ceramic pellet, and the neutron converter can be uranium (with 20% enrichment in {sup 235}U) or boron (with natural isotopic abundance or with 92.41% enrichment in {sup 10}B). The proposed pyroelectric neutron detector is interesting, but not suitable for fast neutron detection accompanied with gamma rays. As the polyvinylidene fluoride (PVDF) is also a kind of ferroelectric material, but with a low density about 1.78 g/cm{sup 3}, indicating a low sensitivity to gamma radiation. This material contains about 3.35 x 10{sup 22}/cm{sup 3} of H, which has a relatively large cross section with fast neutrons. The PVDF possibly has the potential for fast neutron detection, and the response of ferroelectric polyvinylidene fluoride under pulsed fast neutron irradiation was reported. (authors)

36 MATERIALS SCIENCE↗

Requirements and sensitivity analysis for temporally- and spatially-resolved thermometry using neutron resonance spectroscopy

Neutron resonance spectroscopy (NRS) has been used extensively to make temperature measurements that are accurate, absolute, and nonperturbative within the interior of material samples under extreme conditions applied quasistatically. Yet NRS has seldom been used in dynamic experiments. There is a compelling incentive to do so because of the significant shortcomings of alternative techniques. An important barrier to adopting dynamic NRS thermometry is the difficulty in fielding it with conventional spallation neutron sources. To enable time-dependent and spatially resolved temperature measurements in dynamic environments, more compact neutron sources that can be used at user facilities in conjunction with other diagnostic probes (such as x-ray light sources) are required. Such sources may be available using ultrafast high-intensity optical lasers. We evaluate such possibilities by determining the sensitivities of the temperature estimate on neutron-beam and diagnostic parameters. Based on that evaluation, requirements are set on a pulsed neutron-source and diagnostics to make a meaningful dynamic temperature measurement. Dynamic thermometry measurements are examined in this context when driven by two alternative fast-neutron sources: the Los Alamos Neutron Scattering Center (LANSCE) proton accelerator driving isotropic spallation neutrons as a baseline and a laser-plasma ion accelerator driving a neutron beam from deuterium breakup. Strategies to close the gap between the required and demonstrated performance of laser-based fast-neutron sources are presented. A short-pulse high-intensity laser with state-of-the-art pulse contrast and an energy of a few hundred Joules would drive a compact neutron source suitable for NRS thermometry that could transform the dynamic study of materials.

47 OTHER INSTRUMENTATION↗

Statistical and systematic uncertainties in extracting the source properties of neutron star-black hole binaries with gravitational waves

Gravitational waves emitted by neutron star black hole mergers encode key properties of neutron stars - such as their size, maximum mass and spins - and black holes. However, the presence of matter and the high mass ratio makes generating long and accurate waveforms from these systems hard to do with numerical relativity, and not much is known about systematic uncertainties due to waveform modeling. In this work, we simulate gravitational waves from neutron star black hole mergers by hybridizing numerical relativity waveforms produced with the SpEC code with a recent numerical relativity surrogate NRHybSur3dq8Tidal. These signals are analyzed using a range of available waveform families, and statistical and systematic errors are reported. We find that at a network signal-to-noise ratio (SNR) of 30, statistical uncertainties are usually larger than systematic offsets, while at an SNR of 70 the two become comparable. The individual black hole and neutron star masses, as well as the mass ratios, are typically measured very precisely, though not always accurately at high SNR. At a SNR of 30 the neutron star tidal deformability can only be bound from above, while for louder sources it can be measured and constrained away from zero. All neutron stars in our simulations are non-spinning, but in no case we can constrain the neutron star spin to be smaller than ~0.4 (90% credible interval). Waveform families whose late inspiral has been tuned specifically for neutron star black hole signals typically yield the most accurate characterization of the source parameters. Their measurements are in tension with those obtained using waveform families tuned against binary neutron stars, even for mass ratios that could be relevant for both binary neutron stars and neutron star black holes mergers.

79 ASTRONOMY AND ASTROPHYSICS↗