Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monte Carlo Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Development of Heterogeneous Ice Nucleation Rate Coefficient Parameterizations From Ambient Measurements

Ice nucleating particles (INPs) are a rare subset of particles that can have an outsized impact relative to their prevalence. To simulate INP variability, models require parameterizations for the most important sources of INPs. Most parameterizations in the literature were developed from laboratory experiments that used proxies for ambient particles. Whether these laboratory models effectively represent ambient aerosol is still not well understood and parameterizations developed from field measurements may be more atmospherically relevant. Expanding on previous work in which we used an ice chamber and a single-particle mass spectrometer (SPMS) to characterize INP composition, we calculate heterogeneous ice nucleation rate coefficients for ambient particles. We find good agreement between our dust and previous measurements of airborne dust. We also use a Monte Carlo approach to assess the relative contribution of each measurement to the uncertainty and find that the biggest source is the sampling efficiency of the SPMS.

54 ENVIRONMENTAL SCIENCES↗

Damage and Microstructure Evolution in GaN under Au Ion Irradiation

Damage and microstructure evolution in gallium nitride (GaN) under Au+ ion irradiation has been investigated using complementary electron microscopy, secondary ion mass spectrometry and ion beam analysis techniques. Epitaxially-grown GaN layers (2-um-thick) have been irradiated by 2.0 MeV Au ions to 1.0 × 1015 and 1.4 × 1015 cm-2 at 155 K and 7.3 × 1015 cm-2 at 200 K. The irradiation-induced damage has been analyzed by Rutherford backscattering spectroscopy in a channeling direction (RBS/C). For a better determination of ion-induced disorder profile, an iterative procedure and a Monte Carlo code (McChasy) are combined to analyze the ion channeling spectra. With increasing irradiation dose, separated amorphous layers develop from the sample surface and near the damage peak region. Formation of large nitrogen bubbles with sizes up to 70 nm is observed in the buried amorphous layer, while the surface layer contains small bubbles with diameter of a few nanometers due to significant nitrogen loss from the surface. Volume expansion from 3% to 25% in the irradiated region is suggested by cross sectional transmission electron microscope and RBS/C measurement. The anomalous shape of the Au distributions under three irradiations indicates out-diffusion of Au toward sample surface. The results from the complementary techniques suggest that nitrogen is retained in the damaged GaN where the crystallinity is preserved. Once the amorphous state is reached in the surface region, GaN starts to decompose and nitrogen escapes from the surface. Furthermore, experimental results show considerable errors in both disorder profile and ion range predicted by the Stopping and Range of Ions in Matter code, indicating a significant overestimation of electronic stopping powers of Au ions in GaN.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Model Analysis ToolKit

MATK provides basic functionality to facilitate model analysis within the Python computational environment. Model analysis setup within MATK includes: - define parameters - define observations - define model (python function) - define samplesets (sets of parameter combinations) Currently supported functionality includes: - forward model runs - Latin-Hypercube sampling of parameters - multi-dimensional parameter studies - parallel execution of parameter samples - model calibration using internal Levenberg-Marquardt algorithm - model calibration using lmfit package - model calibration using levmar package - Markov Chain Monte Carlo using pymc package MATK facilitates model analysis using: - scipy - calibration (scipy.optimize) - rpy2 - Python interface to R

Harp, DylanR.↗

Simple strategy for the simulation of axially symmetric large-area metasurfaces

Metalenses are composed of nanostructures for focusing light and have been widely explored in many exciting applications. However, their expanding dimensions pose simulation challenges. We propose a method to simulate metalenses in a timely manner using vectorial wave and ray tracing models. We sample the metalens’s radial phase gradient and locally approximate the phase profile by a linear phase response. Each sampling point is modeled as a binary blazed grating, employing the chosen nanostructure, to build a transfer function set. The metalens transmission or reflection is then obtained by applying the corresponding transfer function to the incoming field on the regions surrounding each sampling point. Fourier optics is used to calculate the scattered fields under arbitrary illumination for the vectorial wave method, and a Monte Carlo algorithm is used in the ray tracing formalism. We validated our method against finite-difference time domain simulations at 632 nm, and we were able to simulate metalenses larger than 3000 wavelengths in diameter on a personal computer.

Martins, Augusto (ORCID:0000000295546481)↗

Simulation of turbulent wall pressure

A Monte Carlo procedure was developed to simulate turbulent boundary layer wall pressure fluctuations. The approach utilizes much of the newly available conditional sampling information to construct the required distribution functions. Various disturbance wave forms were examined, as well as the effect of frequency-dependent decay. Good agreement between the simulation and experimental data was achieved for root mean square pressure level, power spectrum, and space time correlation.

Ash, R. L.↗

Stress Rupture Life Reliability Measures for Composite Overwrapped Pressure Vessels

Composite Overwrapped Pressure Vessels (COPVs) are often used for storing pressurant gases onboard spacecraft. Kevlar (DuPont), glass, carbon and other more recent fibers have all been used as overwraps. Due to the fact that overwraps are subjected to sustained loads for an extended period during a mission, stress rupture failure is a major concern. It is therefore important to ascertain the reliability of these vessels by analysis, since the testing of each flight design cannot be completed on a practical time scale. The present paper examines specifically a Weibull statistics based stress rupture model and considers the various uncertainties associated with the model parameters. The paper also examines several reliability estimate measures that would be of use for the purpose of recertification and for qualifying flight worthiness of these vessels. Specifically, deterministic values for a point estimate, mean estimate and 90/95 percent confidence estimates of the reliability are all examined for a typical flight quality vessel under constant stress. The mean and the 90/95 percent confidence estimates are computed using Monte-Carlo simulation techniques by assuming distribution statistics of model parameters based also on simulation and on the available data, especially the sample sizes represented in the data. The data for the stress rupture model are obtained from the Lawrence Livermore National Laboratories (LLNL) stress rupture testing program, carried out for the past 35 years. Deterministic as well as probabilistic sensitivities are examined.

Murthy, Pappu L. N.↗

A Blueprint for Demonstrating Quantum Supremacy with Superconducting Qubits

Long coherence times and high fidelity control recently achieved in scalable superconducting circuits paved the way for the growing number of experimental studies of many-qubit quantum coherent phenomena in these devices. Albeit full implementation of quantum error correction and fault tolerant quantum computation remains a challenge the near term pre-error correction devices could allow new fundamental experiments despite inevitable accumulation of errors. One such open question foundational for quantum computing is achieving the so called quantum supremacy, an experimental demonstration of a computational task that takes polynomial time on the quantum computer whereas the best classical algorithm would require exponential time and/or resources. It is possible to formulate such a task for a quantum computer consisting of less than a 100 qubits. The computational task we consider is to provide approximate samples from a non-trivial quantum distribution. This is a generalization for the case of superconducting circuits of ideas behind boson sampling protocol for quantum optics introduced by Arkhipov and Aaronson. In this presentation we discuss a proof-of-principle demonstration of such a sampling task on a 9-qubit chain of superconducting gmon qubits developed by Google. We discuss theoretical analysis of the driven evolution of the device resulting in output approximating samples from a uniform distribution in the Hilbert space, a quantum chaotic state. We analyze quantum chaotic characteristics of the output of the circuit and the time required to generate a sufficiently complex quantum distribution. We demonstrate that the classical simulation of the sampling output requires exponential resources by connecting the task of calculating the output amplitudes to the sign problem of the Quantum Monte Carlo method. We also discuss the detailed theoretical modeling required to achieve high fidelity control and calibration of the multi-qubit unitary evolution in the device. We use a novel cross-entropy statistical metric as a figure of merit to verify the output and calibrate the device controls. Finally, we demonstrate the statistics of the wave function amplitudes generated on the 9-gmon chain and verify the quantum chaotic nature of the generated quantum distribution. This verifies the implementation of the quantum supremacy protocol.

Kechedzhi, Kostyantyn↗

Uncertainty in Heart Rate Complexity Metrics Caused by R-Peak Perturbations

Heart rate complexity (HRC) is a proven metric for gaining insight into human stress and physiological deterioration. To calculate HRC, the detection of the exact instance of when the heart beats, the R-peak, is necessary. Electrocardiogram (ECG) signals can often be corrupted by environmental noise (e.g., from electromagnetic interference, movement artifacts), which can potentially alter the HRC measurement, producing erroneous inputs which feed into decision support models. Current literature has only investigated how HRC is affected by noise when R-peak detection errors occur (false positives and false negatives). However, the numerical methods used to calculate HRC are also sensitive to the specific location of the fiducial point of the R-peak. This raises many questions regarding how this fiducial point is altered by noise, the resulting impact on the measured HRC, and how we can account for noisy HRC measures as inputs into our decision models. This work uses Monte Carlo simulations to systematically add white and pink noise at different permutations of signal-to-noise ratios (SNRs), time segments, sampling rates, and HRC measurements to characterize the influence of noise on the HRC measure by altering the fiducial point of the R-peak. Using the generated information from these simulations provides improved decision processes for system design which address key concerns such as permutation entropy being a more precise, reliable, less biased, and more sensitive measurement for HRC than sample and approximate entropy.

Napoli, Nicholas J.↗

Model Analysis ToolKit

MATK provides basic functionality to facilitate model analysis within the Python computational environment. Model analysis setup within MATK includes: - define parameters - define observations - define model (python function) - define samplesets (sets of parameter combinations) Currently supported functionality includes: - forward model runs - Latin-Hypercube sampling of parameters - multi-dimensional parameter studies - parallel execution of parameter samples - model calibration using internal Levenberg-Marquardt algorithm - model calibration using lmfit package - model calibration using levmar package - Markov Chain Monte Carlo using pymc package MATK facilitates model analysis using: - scipy - calibration (scipy.optimize) - rpy2 - Python interface to R

Harp, Dylan R.↗

Application of a Coincidence Ring Ratio Moderator Correction to the Assay of 235U Residues

Processing of irradiated UAl targets by NaOH dissolution for the extraction of 99Mo results in the creation of high-activity highly enriched uranium (HEU)–bearing residues that must be quantified. The HEU residues generated from this process are assayed using an Active Well Coincidence Counter (AWCC) that has been modified to accommodate >1 Sv/h gamma-ray exposure rates to provide a 235U mass value for each residues container. The HEU residues include a significant amount of residual moderator from the dissolution process. Fission product decay heat drives off much—but not all—of the hydrogen from the dissolution, leaving an unknown moderator content in the residues. The moderator content impacts the induced fission rate in the HEU, detection efficiency, and die-away time of the emitted neutrons and requires implementation of a moderator correction factor. Three moderator correction techniques have been implemented: an active coincidence ring ratio method, a conventional 252Cf Add-A-Source (AAS) measurement, and an AAS ring ratio measurement. The 252Cf AAS and the AAS ring ratio methods are potentially much faster, but they require additional sample handling and precise positioning of the residues container and the 252Cf source. This study was performed using a combination of Monte Carlo N-Particle (MCNP) [1] simulation and measurements. The impact of the moderator content on the AWCC measurement and the relative performance of the three moderator correction methods are presented.

Mcelroy Jr, Robert↗

Features added in new release of SRFYDO - February 2009

Version 2.0 of SRFYDO, released in February 2009, has a number of new features. This document describes these additions and is designed to complement the document 'Calculating System Reliability with SRFYDO: A User Guide' (Los Alamos National Laboratory Technical Report LA-UR 08-06161). The new features include: (1) Reliability Estimates for Combinations of Components - Users can now estimate the reliability of collections of components, such as a sections or sub-systems. This optional feature is activated via a new table, SectionDef, which is used to define names and component associations for the section or sub-system aggregate. If the SectionDef table is present, section plots and tabulated reliabilities will be created during the SRY3 phase. For more details see section 1. (2) Plots of System or Component Reliability Priors - SRFYDO now creates reliability plots for each system (if system priors were given) or each component (if component priors were given) during the SRY1 phase. These plots, written in the directory 'priorPDFs', are provided to help users visualize the impact of their estimates on the final reliability calculation. For more details see section 2. (3) Convenient Exclusion of Lifecycle Covariates - Both GUI and command-line interfaces to SRFYDO now allow the user to exclude one or both of the lifecycle covariates without requiring modification to the spreadsheet. With this capability users can readily explore the effect of adding or removing lifecycle measures on the resulting statistical analysis. Note that excluding a lifecycle covariate is not the same as setting its rate (-b or -c) to zero. For more details see section 3. (4) MCMC Diagnostic Plots - Diagnostic or 'trace' plots may optionally be created for each of the statistical parameters generated during the Monte Carlo phase (SRY2). These plots can help the user determine if (1) appropriate lifecycle variable choices have been made, (2) more sampling iterations, '-i', are required, and (3) suggest the number of samples to discard, '-x', for optimal results. For more details see section 4. (5) Sample Thinning - A sample thinning feature (-e) allows advanced users to address parameter correlation issues diagnosed by trace plots (section 4). For more details see section 5. (6) Version Compatibility - An incompatibility with the previous version of SRFYDO was introduced. If you use different SRFYDO versions for different phases of an analysis see section 6.

97 MATHEMATICS AND COMPUTING↗

Recent Progress on the Stochastic Objective Decision Aide (SODA) Application

Idaho State University, in collaboration with Idaho National Laboratory, is engaged in development of a simple to use software application that utilizes stochastic techniques for the calculation of radiation doses associated with hypothetical radioactive material releases. This work is being performed through a grant from the U.S. Department of Energy (DOE) Nuclear Safety Research and Development (NSR and D) Program. Initial progress on the application was reported previously. Recent additions to the application are reported here. The Stochastic Objective Decision Aide (SODA) provides an easy to use software application to help decision makers support their judgment about the need or lack of need for safety structures, systems, and components. SODA is not intended to replace traditional design basis accident dose calculation methodology, nor is it intended to replace existing software used to perform formal dose consequence calculations. Rather, SODA is intended to supplement information obtained from existing codes to give a decision maker more information about an accident scenario. SODA also provides a simple method to perform parametric or sensitivity studies on individual input parameters. Non-reactor nuclear facilities operated under the approval authority of the US DOE use unmitigated hazard evaluations to determine if potential radiological doses associated with design basis events challenge dose evaluation guidelines. Unmitigated events that sufficiently challenge dose evaluation guidelines merit the selection of safety structures, systems, or components (SSCs) to prevent or mitigate the hazard. Dose consequence calculations traditionally involve use of the 'five-factor' formula: ST = MAR.DR.ARF.RF.LPF where ST is the source term (Bq), MAR is the total available material-at-risk (Bq), DR is the damage ratio (no units), ARF is the airborne release fraction (no units), RF is the respirable fraction (no units), and LPF is the leak path factor (no units). Potential radiation doses are then calculated using: CED = χ/Q.BR.ST.DCF (2) where CED is the committed effective dose (Sv), χ/Q is the plume dispersion (s/m{sup 3}), BR is the breathing rate (m{sup 3}/s), ST is the source term (Bq), and DCF is the dose conversion factor (Sv/Bq). Conservative single value input parameters are typically used to represent ARF, RF, LPF and BR. The traditional methodology, while conservative, can lead to skewed conclusions in the balance between cost and risk reduction resulting in over engineered systems with greater design, construction and operating costs. Rather than using a bounding single point value for each parameter in the dose consequence calculation, SODA uses distributions for some or all of the parameters. Each input parameter distribution is stochastically sampled and the resulting dose consequence calculation is repeated many times to develop a dose consequence distribution. The resulting distribution provides more information for the decision maker to rely upon when determining the need for safety SSCs. The SODA application was developed using MATLAB and it incorporates the use of Monte Carlo techniques as well as a graphical user interface (GUI). The application includes user selection of the governing distribution for parameters such as the MAR, DR, ARF, RF, LPF,χ/Q, BR, and DCF. While MATLAB was used for the development work, the application is distributed as a self-contained executable program. Features of the application include pull down menus with available distributions for the various parameters. The user has the option to plot the input parameter distribution that results from the random sampling process. The resulting dose consequence distribution is automatically analyzed to determine its similarity to well know distributions. This was done using the Bayesian Information Criterion method. If the resulting distribution is sufficiently similar to a well-known distribution, the application provides information about the distributions such as the mean value and other parameters. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Uncertainty Underprediction in Monte Carlo Eigenvalue Calculations

It is well-known that statistical estimates obtained from Monte Carlo criticality simulations can be adversely affected by cycle-to-cycle correlations in the fission source, which can lead to estimates of statistical uncertainties that are lower than the true uncertainty by a factor of 5 or more. However, several other more fundamental issues such as adequate source sampling over the fissionable regions and source convergence can have a significant impact on the uncertainties for the calculated eigenvalue and localized tally means, and these issues may be mistaken for effects resulting from cycle-to-cycle correlations. In worst-case scenarios, the uncertainty may be underpredicted by a factor of 40 or more. Since Monte Carlo methods are widely used in criticality safety applications and are increasingly being used for benchmarking reactor analyses, an in-depth understanding of the effects of these issues must be developed in order to support the practical use of Monte Carlo software packages. A rigorous statistical analysis of eigenvalue and localized tally results in Monte Carlo criticality calculations is presented using the SCALE/KENO-VI (continuous-energy version) and MCNP codes. The purpose of this analysis is to investigate the underprediction of uncertainty and its sensitivity to problem characteristics and calculational parameters using two of the most widely used Monte Carlo criticality codes. For the problems considered here, which are fuel rod and fuel assembly problems with reflecting boundary conditions on all four horizontal sides, we show that adequate source convergence along with proper specification of Monte Carlo parameters can reduce the magnitude of uncertainty underprediction to reasonable levels, below a factor of 2 in most cases.

Mervin, Brenden T↗

THE GLOBULAR CLUSTER SYSTEM OF THE MILKY WAY: ACCRETION IN A COSMOLOGICAL CONTEXT

We examine the significance of a planar arrangement in the spatial distribution of the Milky Way (MW) globular clusters (GCs). We find that, when separated on the basis of horizontal branch morphology and metallicity, the outermost canonical young halo (YH) GC sample (at galactocentric radii in excess of 10 kpc) exhibits an anisotropic distribution that may be equated to a plane (24 {+-} 4) kpc thick (rms) and inclined at 8 Degree-Sign {+-} 5 Degree-Sign to the polar axis of the MW disk. To quantify the significance of this plane we determine the fraction of times that an isotropic distribution replicates the observed distribution in Monte Carlo trials. The plane is found to remain significant at the >95% level outside a galactocentric radius of 10 kpc, inside this radius the spatial distribution is apparently isotropic. In contrast, the spatial distribution of the old halo sample outside 10 kpc is well matched by an isotropic distribution. The plane described by the outer YH GCs is indistinguishable in orientation from that presented by the satellite galaxies of the MW. Simulations have shown that the planar arrangement of satellites can arise as filaments of the surrounding large-scale structure feed into the MW's potential. We therefore propose that our results are direct observational evidence for the accreted origin of the outer YH GC population. This conclusion confirms numerous lines of evidence that have similarly indicated an accreted origin for this set of clusters from the inferred cluster properties.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

An adaptive multi-level simulation algorithm for stochastic biological systems

Discrete-state, continuous-time Markov models are widely used in the modeling of biochemical reaction networks. Their complexity often precludes analytic solution, and we rely on stochastic simulation algorithms (SSA) to estimate system statistics. The Gillespie algorithm is exact, but computationally costly as it simulates every single reaction. As such, approximate stochastic simulation algorithms such as the tau-leap algorithm are often used. Potentially computationally more efficient, the system statistics generated suffer from significant bias unless tau is relatively small, in which case the computational time can be comparable to that of the Gillespie algorithm. The multi-level method [Anderson and Higham, “Multi-level Monte Carlo for continuous time Markov chains, with applications in biochemical kinetics,” SIAM Multiscale Model. Simul. 10(1), 146–179 (2012)] tackles this problem. A base estimator is computed using many (cheap) sample paths at low accuracy. The bias inherent in this estimator is then reduced using a number of corrections. Each correction term is estimated using a collection of paired sample paths where one path of each pair is generated at a higher accuracy compared to the other (and so more expensive). By sharing random variables between these paired paths, the variance of each correction estimator can be reduced. This renders the multi-level method very efficient as only a relatively small number of paired paths are required to calculate each correction term. In the original multi-level method, each sample path is simulated using the tau-leap algorithm with a fixed value of τ. This approach can result in poor performance when the reaction activity of a system changes substantially over the timescale of interest. By introducing a novel adaptive time-stepping approach where τ is chosen according to the stochastic behaviour of each sample path, we extend the applicability of the multi-level method to such cases. We demonstrate the efficiency of our method using a number of examples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗