Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MIRRORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Observation of Electromagnetic Transients in a Nb3Sn 4-layer Dipole Mirror Magnet

During testing of the Stress Managed Cosine-Theta dipole mirror magnet SMCTM1, magnet quenches were observed following large voltage spikes in the half-coil voltage taps which preceded normal quench initiation. Following some recent work at CERN measuring power current converter transients in relation to flux jumps, an additional differential current probe was added to the magnet instrumentation. Measurements of this probe, as well as the half coil voltage taps show a fast and substantial current change preceding the quench, hinting at coil motion. A simple model based on relative shift of the inner and outer layer coils was developed which suggests the magnitude of coil shift events is on the estimated relative coil shift from the magnet constraint conditions. The behavior is shown to be reversible and characteristic of stick-slip.

Krave, Steven [Fermilab] (ORCID:0000000217521457)↗

High-accuracy Aspheric X-ray Mirror Metrology Using Software Configurable Optical Test System/deflectometry

The Software Configurable Optical Test System (SCOTS) uses deflectometry to measure surface slopes of general optical shapes without the need for additional null optics. Careful alignment of test geometry and calibration of inherent system error improve the accuracy of SCOTS to a level where it competes with interferometry. We report a SCOTS surface measurement of an off-axis superpolished elliptical x-ray mirror that achieves <1 nm<1 nm root-mean-square accuracy for the surface measurement with low-order term included.

42 ENGINEERING↗

Transfer of autocollimator calibration for use with scanning gantry profilometers for accurate determination of surface slope and curvature of state-of-the-art x-ray mirrors

X-ray optics, desired for beamlines at free-electron-laser and diffraction-limited-storage-ring x-ray light sources, must have almost perfect surfaces, capable of delivering light to experiments without significant degradation of brightness and coherence. To accurately characterize such optics at an optical metrology lab, two basic types of surface slope profilometers are used: The long trace profilers (LTPs) and nanometer optical measuring (NOM) like angular deflectometers, based on electronic autocollimator (AC) ELCOMAT-3000. The inherent systematic errors of the instrument's optical sensors set the principle limit to their measuring performance. Where autocollimator of a NOM-like profiler may be calibrated at a unique dedicated facility, this is for a particular configuration of distance, aperture size, and angular range that does not always match the exact use in a scanning measurement with the profiler. Here we discuss the developed methodology, experimental set-up, and numerical methods of transferring the calibration of one reference AC to the scanning AC of the Optical Surface Measuring System (OSMS), recently brought to operation at the ALS Xray Optics Laboratory. We show that precision calibration of the OSMS performed in three steps, allows us to provide high confidence and accuracy low-spatial-frequency metrology and not â€print into' measurements the inherent systematic error of tool in use. Here, with the examples of the OSMS measurements with a state-of-The-Art x-ray aspherical mirror, available from one of the most advanced vendors of X-ray optics, we demonstrate the high efficacy of the developed calibration procedure. The results of our work are important for obtaining high reliability data, needed for sophisticated numerical simulations of beamline performance and optimization of beamline usage of the optics. This work was supported by the U. S. Department of Energy under contract number DE-AC02-05CH11231.

47 OTHER INSTRUMENTATION↗

Broadband, 920-nm mirror thin film damage competition

This year’s competition proposed to survey the state-of-the-art broadband, near-IR multilayer dielectric (MLD) mirrors designed for ultra-short, pulsed laser applications. The requirements for the coatings were a minimum reflection of 99.5% at 45-degree incidence angle for S-polarization from 830 nm to 1010 nm and group delay dispersion (GDD) < ± 50 fs 2 . The participants in this effort selected the coating materials, coating design, and deposition method. Samples were damage tested at a single testing facility to enable direct comparison among the participants using a 25 ± 5 fs OPCPA laser system operating at 5 Hz. A double blind test assured sample and submitter anonymity. The damage performance results, sample rankings, details of the deposition processes, coating materials and substrate cleaning methods are shared here. We found that multilayer coatings using tantala and/or hafnia as high index materials were top performers within several coating deposition groups. Specifically, dense coatings by ion-beam sputtering (IBS), magnetron sputtering (MS), and electron-beam ion assisted deposition (e-beam IAD) exhibited highest damage initiation onset (LIDT) while e-beam coatings were low performers. In addition, damage growth onset (LDGT) was also examined and the results are reported here for all samples as this performance metric plays an important role in establishing the safe operational conditions for larger aperture, ultrashort pulsed lasers. As a result, not all coating samples in the survey met the GDD requirements stated above and associated measurements are discussed in the context of the present and past competitions focused on similar broadband, near-IR MLD coatings.

42 ENGINEERING↗

SU-E-T-774: Use of a Scintillator-Mirror-Camera System for the Measurement of MLC Leakage Radiation with the CyberKnife M6 System

Purpose: A technique using a scintillator-mirror-camera system to measure MLC leakage was developed to provide an efficient alternative to film dosimetry while maintaining high spatial resolution. This work describes the technique together with measurement uncertainties. Methods: Leakage measurements were made for the InCise™ MLC using the Logos XRV-2020A device. For each measurement approximately 170 leakage and background images were acquired using optimized camera settings. Average background was subtracted from each leakage frame before filtering the integrated leakage image to replace anomalous pixels. Pixel value to dose conversion was performed using a calibration image. Mean leakage was calculated within an ROI corresponding to the primary beam, and maximum leakage was determined by binning the image into overlapping 1mm x 1mm ROIs. 48 measurements were performed using 3 cameras and multiple MLC-linac combinations in varying beam orientations, with each compared to film dosimetry. Optical and environmental influences were also investigated. Results: Measurement time with the XRV-2020A was 8 minutes vs. 50 minutes using radiochromic film, and results were available immediately. Camera radiation exposure degraded measurement accuracy. With a relatively undamaged camera, mean leakage agreed with film measurement to ≤0.02% in 92% cases, ≤0.03% in 100% (for maximum leakage the values were 88% and 96%) relative to reference open field dose. The estimated camera lifetime over which this agreement is maintained is at least 150 measurements, and can be monitored using reference field exposures. A dependency on camera temperature was identified and a reduction in sensitivity with distance from image center due to optical distortion was characterized. Conclusion: With periodic monitoring of the degree of camera radiation damage, the XRV-2020A system can be used to measure MLC leakage. This represents a significant time saving when compared to the traditional film-based approach without any substantial reduction in accuracy.

60 APPLIED LIFE SCIENCES↗

Ultrafast manipulation of mirror domain walls in a charge density wave

Domain walls (DWs) are singularities in an ordered medium that often host exotic phenomena such as charge ordering, insulator-metal transition, or superconductivity. The ability to locally write and erase DWs is highly desirable, as it allows one to design material functionality by patterning DWs in specific configurations. We demonstrate such capability at room temperature in a charge density wave (CDW), a macroscopic condensate of electrons and phonons, in ultrathin 1T-TaS 2 . A single femtosecond light pulse is shown to locally inject or remove mirror DWs in the CDW condensate, with probabilities tunable by pulse energy and temperature. Using time-resolved electron diffraction, we are able to simultaneously track anti-synchronized CDW amplitude oscillations from both the lattice and the condensate, where photoinjected DWs lead to a red-shifted frequency. Our demonstration of reversible DW manipulation may pave new ways for engineering correlated material systems with light.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of the development of relativistic plasma bunches in a long mirror trap by optical and X-ray imaging and numerical simulations

The work presents experimental results demonstrating the feasibility of autoresonance acceleration of electrons in a long mirror trap with a reverse magnetic field. It is shown that gyromagnetic autoresonance results in the formation of a plasma bunch with average electron energy of several hundred keV, which is confined for a long time in the trap. The results of computer simulations of the regime of reverse gyromagnetic autoresonance agree well with the experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of the Plasma Parameters in a Mirror Trap by Means of Laser-Induced Fluorescence

Results of measurements of the absolute density of ArII ions in a mirror trap with a toroidal divertor are presented. The ion density was measured by the method of laser-induced fluorescence with the use of ArII metastable states. A technique is proposed to estimate the plasma electron temperature from the ratio of the fluorescence signals obtained by comparing the intensities of different optical transitions of ArII.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron-mirror duality and thermality

Classical electromagnetic radiation from moving point charges is foundational, but the thermal dynamics responsible for classical acceleration temperature are poorly understood. We investigate the thermal properties of classical electromagnetic radiation in the context of the correspondence between accelerated electrons and moving mirrors, focusing on three trajectories with asymptotically infinite (Davies–Fulling), asymptotically zero (Walker–Davies), and eternally uniform acceleration. The latter two are argued not to be thermal, while the former is found to emit thermal photons with a temperature that depends on the electron’s speed. Thermal radiation occurs in the absence of jerk.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A mechanism for weak itinerant antiferromagnetism: Mirrored van Hove singularities

Unlike the other prominent macroscopic spin-paired quantum state, superconductivity, where the focus is on the strongest coupling within a class, untuned weak magnetism presents an intellectual frontier where electronic structure, magnetic coupling, and (quantum and thermal) fluctuations provide a platform for unconventional phenomena. With a strong van Hove singularity (vHs) at the Fermi energy, TiAu (with no magnetic element) is highly unstable toward ferromagnetism, yet orders antiferromagnetically at a wave vector unrelated to Fermi surface nesting. We show that mirrored vHs provide the long-wavelength, low-frequency fluctuations characteristic of a wFM rather than that of a conventional wAFM, whereby wAFM competes on equal terms with wFM for the broken symmetry ordered state. Peierls-like energy gain from cell doubling can help promote wAFM, which is evident in TiAu.

Goh, Wen Fong↗

Broadband astigmatism-free Czerny-Turner imaging spectrometer using spherical mirrors

We describe the elimination of the astigmatism of a Czerny-Turner imaging spectrometer, built using spherical optics and a plane grating, over a broad spectral region. Starting with the principle of divergent illumination of the grating, which removes astigmatism at one chosen wavelength, we obtain design equations for the distance from the grating to the focusing mirror and the detector angle that remove the astigmatism to first order in wavelength. Experimentally, we demonstrate near diffraction-limited performance from 740 to 860 nm and over a 5 mm transverse spatial extent, while ray-tracing calculations show that barring finite-aperture and detector size limitations, this range extends from 640 to 900 nm and over 10 mm transversely. Our technique requires no additional optics and uses standard off-the-shelf components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sidelobe modeling and mitigation for a three mirror anastigmat cosmic microwave background telescope

Telescopes measuring cosmic microwave background (CMB) polarization on large angular scales require exquisite control of systematic errors to ensure the fidelity of the cosmological results. In particular, far-sidelobe contamination from wide angle scattering is a potentially prominent source of systematic error for large aperture microwave telescopes. Here we describe and demonstrate a ray-tracing-based modeling technique to predict far sidelobes for a three mirror anastigmat telescope designed to observe the CMB from the South Pole. Those sidelobes are produced by light scattered in the receiver optics subsequently interacting with the walls of the surrounding telescope enclosure. After comparing simulated sidelobe maps and angular power spectra for different enclosure wall treatments, we propose a highly scattering surface that would provide more than an order of magnitude reduction in the degree-scale far-sidelobe contrast compared to a typical reflective surface. Finally, we conclude by discussing the fabrication of a prototype scattering wall panel and presenting measurements of its angular scattering profile.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electric-field enhancement caused by subwavelength-sized particles located on the surface of multilayer dielectric mirrors

A laser pulse impinging on the surface of an optical component can interact with particles, such as contamination debris, to produce a scattered electric field, which, either by itself or combined with the incident laser field, coherently can significantly increase the local field intensity. This effect can be of critical importance as it can reduce the laser-induced–damage threshold of the affected component. In this work, we use a field-propagation code to improve understanding regarding the factors that determine the magnitude and location of the electric-field enhancement for the case of subwavelength-sized particles located on the surface of multilayer dielectric mirrors.

47 OTHER INSTRUMENTATION↗

Pulse duration dependent effects of ultrafast laser induced damage on a 1030 nm multi-layer dielectric mirror for high repetition rate, high average power laser systems

High repetition rate, high peak, and average power laser systems are crucial for next-generation particle accelerators, inertial confinement fusion, and secondary particle sources. These applications demand durable laser optics, particularly interference coatings on optics lasting millions of shots at high fluence. This study focuses on designing, testing, and simulating multi-layer dielectric (MLD) mirrors for pulse durations of 260 fs, 77 fs, and 25 fs at 1030 nm wavelength and 45-degree incidence angle with p -polarization. S-on-1 laser-induced damage thresholds (LIDT) for varying pulse numbers were determined, with single-shot LIDT values of 0.98 Jcm -2 , 1.63 Jcm -2 , and 2.3 Jcm -2 for 25 fs, 77 fs, and 260 fs respectively. A strong correlation between blister shape and local fluence was observed, implying that the layer expansion in a blister depends on local fluence. We have also examined mechanisms responsible for laser-induced stress generation and energy release rates in blister formation. Damage mechanisms are further explored by finite-difference time-domain (FDTD) simulations, incorporating Keldysh strong field ionization, whose predictions were in excellent agreement with the onset of damage determined experimentally. These findings offer insights for enhancing MLD coating technology, promising more efficient and resilient laser systems for diverse scientific and industrial applications.

Noor, Mohamed Yaseen (ORCID:000000021036644X)↗

Improved Advanced Actuated Hybrid Mirrors

This was a collaborative effort to develop and demonstrate an improved Advanced Actuated Hybrid Mirrors (AAHM) for commercial or Government purposes. The AAHM consists of a nanolaminate film replicating a precision optical surface bonded to a Silicon Carbide (SiC) substrate with active figure control capability. The goal of this project was to further the development of specific AAHM technologies. The intent of the CRADA was to combine the expertise of LLNL and NG Xinetics in the manufacture and test of a very high quality AAHM, incorporating lessons learned from earlier joint efforts.

Barbee Jr., Troy W.↗

Alpha Channeling in Mirror Machines

This Final Report for DE-FG02-06ER54851, Alpha Channeling in Mirror Machines, was in fact submitted on April 9, 2010. Some confusion arose because it was submitted as an initial progress report on a related grant, Alpha Channeling in Open- System Magnetic Devices. The original text is reproduced below, except that the publication record is undated. Note that the articles published in 2009 and 2010 reflect work in fact done under DE-FG02-06ER54851.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Metrology for Industry for use in the Manufacture of Grazing Incidence Beam Line Mirrors

The goal of this SBIR was to determine the slope sensitivity of Specular Reflection Deflectometry (SRD) and whether shearing methods had the sensitivity to be able to separate errors in the test equipment from slope error in the unit under test (UUT), or mirror. After many variations of test parameters it does not appear that SRD yields results much better than 1 μ radian RMS independent of how much averaging is done. Of course, a single number slope sensitivity over the full range of spatial scales is not a very insightful number in the same sense as a single number phase or height RMS value in interferometry does not tell the full story. However, the 1 μ radian RMS number is meaningful when contrasted with a sensitivity goal of better than 0.1 μ radian RMS. Shearing is a time proven method of separating the errors in a measurement from the actual shape of a UUT. It is accomplished by taking multiple measurements while moving the UUT relative to the test instrument. This process makes it possible to separate the two errors sources but only to a sensitivity of about 1 μ radian RMS. Another aspect of our conclusions is that this limit probably holds largely independent of the spatial scale of the test equipment. In the proposal for this work it was suggested that a test screen the full size of the UUT could be used to determine the slopes on scales of maybe 0.01 to full scale of the UUT while smaller screens and shorter focal length lenses could be used to measure shorter, or smaller, patches of slope. What we failed to take into consideration was that as the scale of the test equipment got smaller so too did the optical lever arm on which the slope was calculated. Although we did not do a test with a shorter focal length lens over a smaller sample area it is hard to argue with the logic that the slope sensitivity will be about the same independent of the spatial scale of the measurement assuming the test equipment is similarly scaled. On a more positive note, SRD does appear to be a highly flexible, easy to implement, rather inexpensive test for free form optics that require a dynamic range that exceeds that of interferometry. These optics are quite often specified to have more relaxed slope errors, on the order of 1 μ radian RMS or greater. It would be shortsighted to not recognize the value of this test method in the bigger picture.

47 OTHER INSTRUMENTATION↗

Improved Advanced Actuated Hybrid Mirrors Final Report CRADA No. TC02130.0

This was a collaborative effort to develop and demonstrate an improved Advanced Actuated Hybrid Mirrors (AAHM) for commercial or Government purposes. The AAHM consists of a nanolaminate film replicating a precision optical surface bonded to a Silicon Carbide (SiC) substrate with active figure control capability. The goal of this project was to further the development of specific AAHM technologies. The intent of the CRADA was to combine the expertise of LLNL and NG Xinetics in the manufacture and test of a very high quality AAHM, incorporating lessons learned from earlier joint efforts.

47 OTHER INSTRUMENTATION↗