Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC FIELD COIL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

A pulsed current-mode class-D low-voltage high-bandwidth power amplifier for portable NMR systems

Low-field NMR has seen growing interest in recent years, especially for portable applications. The lower homogeneity magnets used for portable applications require short RF pulses to ensure enough transmit bandwidth to excite the sample volume and also support short echo periods. Furthermore, the preferred use of a high-Q coil to improve signal-to-noise ratio (SNR) prolongs the pulse transients. Thus, at such low Larmor frequencies, the excitation pulse transients become comparable or longer than the pulse length, such that the transmit bandwidth begins to limit measurement SNR. This paper describes the design of a pulsed current-mode class-D power (PCMCD) transmitter that addresses this issue by generating high power in a tuned sample coil while maintaining short transients, thus resulting in high output bandwidth. The transmitter also uses a charge recycling mechanism to maximize power efficiency for RF train excitation, which also results in faster pulse repetition rate and reduces allowable echo time. In this work, experimental results from a small form-factor PCMCD transmitter are presented. This design generates a peak RF power of 240 W into a 9.16 µH coil at 4 MHz while operating off a single 12 V power supply. NMR measurement results using the transmitter are also described, showing minimum achievable echo time of 70 µs and 25 µs depending on the transmitter mode of operation.

47 OTHER INSTRUMENTATION↗

Assembly of a Mechanical Model of MQXFB, the 7.2-m-Long Low-$\beta$ Quadrupole for the High-Luminosity LHC Upgrade

The ${\rm Nb_{3}Sn}$low-$\beta$quadrupole MQXF is being developed as a part of the High-Luminosity large hadron collider (LHC) upgrade project. The magnet will be produced in two different configurations, sharing the same cross section but with different lengths. A 7.2-m mechanical model of MQXFB was recently assembled at european organization for nuclear research (CERN) with one copper coil, two low-grade coils, and one rejected coil. Coil dimensions were measured with a portable coordinate measurement machine. The coil pack shimming was designed in order to optimize the field quality and the contacts between the coils and the collars. The azimuthal preload target was defined using the short models experience. The mechanical behavior during loading was monitored by means of strain gauges. The results demonstrated that the structure can provide the required prestress to the coils.

43 PARTICLE ACCELERATORS↗

Control of Edge Transport Barrier relaxations using Resonant Magnetic Perturbations

In divertor tokamak plasmas, an Edge Transport Barrier forms during the L-H transition. A poloidal shear flow has been shown to play a crucial role in the barrier sustainement. The H regime, obtained for a critical value of the heating power, is promising for the next generation of tokamak experiments such as ITER. However, an instability known as Edge Localized Mode (ELM) develops as the power is increased further. ELMs are characterized by intermittent bursts in the radial heat flux, therefore causing the transport barrier to relax quasi-periodically. Over the last decade, the possibility of controlling ELMs has become more and more plausible, as recent experiments were carried out on DIII-D using I-coils, on JET using error field correction coils, and on TEXTOR using an ergodic divertor. These experimental studies demonstrate a qualitative control over the ELMs by imposing a magnetostatic perturbation at the plasma edge. However, in order to get any quantitative result, much work has to be done in the understanding of ELM dynamics. In this work, we present results from numerical simulations of Resistive Ballooning Mode (RBM) turbulence reproducing the stabilization of barrier relaxations by a static magnetic perturbation. We focus our study on the edge region around the resonant surface q = 3. We use the TEXTOR tokamak geometry, and plasma parameters close to those used in typical experiments on this machine.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal conductivity of RHIC superconducting magnet insulation materials at low temperatures

The Electron-Ion Collider (EIC) is planned to be built upon the Relativistic Heavy Ion Collider (RHIC), which vacuum chamber will need to be upgraded to host the EIC hadron beams. For the beam pipe section running through the RHIC superconducting (SC) magnets, the baseline is to insert a screen that will get cooled by thermal contact to the 4.55 K beam pipe of RHIC. Knowing the material properties of the cold mass is thus crucial to understand which is the final temperature that the screen and the superconducting coils in the magnets will reach during the passage of the EIC beams. The thermal conductivities of two insulation materials in the RHIC superconducting magnets and a reference material were measured at cryogenic temperatures at the Magnet Science and Technology division of the National High Magnetic Field Laboratory (NHMFL). The measurements were performed in a Quantum Design physical property measurement system. This report explains the motivation behind this work and summarizes the measurement method and results.

43 PARTICLE ACCELERATORS↗

Traveling-wave induction launchers

An analysis of traveling-wave induction launchers shows that induction is a feasible method of producing armature current and that efficient accelerators can be built without sliding contacts or arcs. In a traveling-wave induction launcher the armature current is induced by a slip speed between the armature and a traveling magnetic field. At 9 m/s slip speed a 9 kg projectile with an aluminum armature weighing 25 percent of the total mass can be accelerated to 3000 m/s in a 5 m-long barrel with a total ohmic loss in the barrel coils and armature of 4 percent of the launch kinetic energy and with an average armature temperature rise of 220 deg C, but a peak excitation frequency of 8600 Hz is required. With a 2 kg launch mass the ohmic loss is 7 percent. A launcher system optimized for rotating generators would have a peak frequency of 4850 Hz; with an aluminum armature weighing 33 percent of the launch mass and a slip speed of 30 m/s the total ohmic loss in the generators, cables, and accelerator would be 43 percent of the launch kinetic energy, and the average armature temperature rise would be 510 deg C.

Elliott, David G.↗

Magnetic bearings with zero bias

A magnetic bearing operating without a bias field has supported a shaft rotating at speeds up to 12,000 rpm with the usual four power supplies and with only two. A magnetic bearing is commonly operated with a bias current equal to half of the maximum current allowable in its coils. This linearizes the relation between net force and control current and improves the force slewing rate and hence the band width. The steady bias current dissipates power, even when no force is required from the bearing. The power wasted is equal to two-thirds of the power at maximum force output. Examined here is the zero bias idea. The advantages and disadvantages are noted.

Brown, Gerald V.↗

Experimental studies of helical solenoid model based on YBCO tape-bridge joints

Helical solenoids that provide solenoid, helical dipole and helical gradient field components are designed for a helical cooling channel (HCC) proposed for cooling of muon beams in a muon collider. The high temperature superconductor (HTS), 12 mm wide and 0.1 mm thick YBCO tape, is used as the conductor for the highest-field section of HCC due to certain advantages, such as its electrical and mechanical properties. To study and address the design, and technological and performance issues related to magnets based on YBCO tapes, a short helical solenoid model based on double-pancake coils was designed, fabricated and tested at Fermilab. Splicing joints were made with Sn-Pb solder as the power leads and the connection between coils, which is the most critical element in the magnet that can limit the performance significantly. This paper summarizes the test results of YBCO tape and double-pancake coils in liquid nitrogen and liquid helium, and then focuses on the study of YBCO splices, including the soldering temperatures and pressures, and splice bending test.

43 PARTICLE ACCELERATORS↗

Probe for operando in situ electrochemical nuclear magnetic resonance spectroscopy

Electrochemical devices with metal casings have been considered incompatible with nuclear magnetic resonance (NMR) spectroscopy because the oscillating magnetic fields (“rf fields”) responsible for excitation and detection of NMR active nuclei do not penetrate metals. According to the present invention, rf fields can still efficiently penetrate into nonmetallic layers of electrochemical cells (such as a coin cell battery configuration) provided the magnetic field is oriented tangentially to the electrochemical cell electrodes in a “skimming” orientation. As an example, noninvasive high field in situ 7Li and 19F NMR of an unmodified commercial off-the-shelf rechargeable coin cell was demonstrated using a traditional external NMR coil setup. The in operando NMR measurements revealed that irreversible physical changes accumulate at the anode during electrochemical cycling.

Sorte, Eric Glenn↗

Design Studies of Magnet Systems for Muon Helical Cooling Channels

Helical cooling channels with superimposed solenoid and helical dipole and quadrupole coils, and a pressurized gas absorber in the aperture offer high efficiency of 6D muon beam cooling. In this paper, we continue design studies and comparison of two basic concepts of magnet system proposed for a helical cooling channel focusing on the high field sections. The results of magnetic analysis and Lorentz force calculations as well as the superconductor choice are presented and discussed.

43 PARTICLE ACCELERATORS↗

Two-photon Lee-Goldburg nuclear magnetic resonance: Simultaneous homonuclear decoupling and signal acquisition

We present NMR signals from a strongly coupled homonuclear spin system, {sup 1}H nuclei in adamantane, acquired with simultaneous two-photon excitation under conditions of the Lee-Goldburg experiment. Small coils, having inside diameters of 0.36 mm, are used to achieve two-photon nutation frequencies of {approx}20 kHz. The very large rf field strengths required give rise to large Bloch-Siegert shifts that cannot be neglected. These experiments are found to be extremely sensitive to inhomogeneity of the applied rf field, and due to the Bloch-Siegert shift, exhibit a large asymmetry in response between the upper and lower Lee-Goldburg offsets. Two-photon excitation has the potential to enhance both the sensitivity and performance of homonuclear dipolar decoupling, but is made challenging by the high rf power required and the difficulties introduced by the inhomogeneous Bloch-Siegert shift. We briefly discuss a variation of the frequency-switched Lee-Goldburg technique, called four-quadrant Lee-Goldburg (4QLG) that produces net precession in the x-y plane, with a reduced chemical shift scaling factor of 1/3.

36 MATERIALS SCIENCE↗

A Computational Procedure for Assessing I$_{c}(\varepsilon$) in Nb$_{3}$Sn/Bi-2212 Hybrid Magnets

The critical current of superconductors is commonly measured by testing unloaded wires under an external magnetic field. While stressed by intense Lorentz forces, the existing HTS/LTS superconductors are prone to a reduction in critical current before reaching their structural mechanical limit. Here, in this work, the magnetic and mechanical analysis of the FNAL 4-layer Bi-2212/Nb$_{3}$Sn hybrid dipole magnet is reported, aimed at predicting the critical current degradation for both the superconductors during powering at 16T. All the Rutherford cables in the coils of the hybrid magnet were modeled at the strand level in Ansys APDL with the heterogeneous cable model. Utilizing this detailed geometry, it was possible to evaluate the effects of strain on the critical current degradation for both the Nb$_{3}$Sn and Bi-2212 superconductors under the intense Lorentz forces. The analysis presented in this paper integrates strain-dependent critical current laws, with parameters derived from experimental data, to simulate the hybrid magnet's performance for all possible current-powering configurations. The proposed methodology enables a detailed assessment of conductor integrity and I$_{C}(\varepsilon$) reduction in existing hybrid magnet designs, providing a versatile and rigorous framework for optimizing future high-field hybrid magnets.

D'Agliano, A. [Lawrence Berkeley National Laborato↗

Overview of recent progress in 3D field physics in KSTAR

Various 3D field physics challenges of magnetically confined plasmas arise when the driving source comes from either externally applied non-axisymmetric 3D magnetic perturbations or plasma instabilities inside the plasma. Recently, several key outstanding topics of 3D field physics have been extensively studied in the Korean Superconducting Tokamak Advanced Research (KSTAR), such as edge-localized-mode (ELM) control by resonant magnetic perturbation (RMP), error field (EF) control, 3D field effects on rotation and transport, and RMP-induced alteration of divertor heat flux and detachment. KSTAR has a few physically unique features (i.e., high rotation and long-pulse plasmas with a low intrinsic EF) and machine/diagnostic capabilities (i.e., 3-row in-vessel control coil and state-of-the-art 2D/3D imaging diagnostics), which have been taken advantage of until now to address critical 3D field physics issues relevant to ITER and K-DEMO. Among many remarkable achievements are the robust access to and control of n = 1 RMP ELM suppression, along with a development of its physics basis tools, parameter expansion, optimization, and long-pulse control techniques. Nonetheless, a series of unresolved 3D physics themes, as well as limited coverage of 3D field operating regimes, have also been identified as future works for the 3D field research in KSTAR. In this paper, we provide an overview about the recent progress of KSTAR 3D field physics and present future plans of KSTAR 3D research toward a future fusion reactor.

3D field physics↗

Small-angle neutron polarimetry apparatus (SANPA): Development at the NIST Center for Neutron Research

Spherical neutron polarimetry directly measures the rotation of the neutron polarization after scattering from materials with magnetic structure. It is an under utilized measurement technique that is capable of measuring all nine elements of the polarization tensor of a material. In this article, we describe our new cryogen-free small-angle neutron polarimetry apparatus and infrastructure at the NIST Center for Neutron Research. The resulting apparatus is capable of continuous operation and is designed for measurements at low temperatures (4–8 K) using niobium Meissner shielding and mu-metal shielding to produce a zero-field (≤1 μT) cooling sample environment.

47 OTHER INSTRUMENTATION↗

Radio-Frequency Rapid Thermal Processing Enabling Spatial Phase Transformation and Nanocrystallization of Soft Magnetic Amorphous Alloys

Thermal processing of soft magnetic amorphous and nanocrystalline alloys is explored under the influence of radio-frequency induction-heating techniques. Direct induction-heating concepts based on longitudinal and transverse flux heating are examined and the details of electromagnetic fields interaction with metallic strips are discussed by analytical calculations as well as finite element analysis. Initial experimental results confirming spatial control of phase transformations and nanocrystallization within a single strip of Finemet Fe-based amorphous ribbons are reported. Here, the degree to which primary and secondary crystallization temperature are achieved depends on the spacing between the ribbon relative to the induction coil as well as the coil design and configuration. For transverse coil configurations, the local temperature and therefore microstructural evolution is different across the lateral dimension of processed ribbons, with reduced gap sizes producing enhanced peak temperatures and larger temperature distributions with greater spatial variation in microstructure. In addition, indirect susceptor-based induction heating under tension is performed and the impact of microstructure is demonstrated. Herein, potential for exploiting spatially optimized phase transformations is illustrated through electromagnetic field–assisted processing in a scalable manufacturing process with amorphous and nanocrystalline soft magnetic alloys.

36 MATERIALS SCIENCE↗

Design and Evaluation of joint resistance in SSC Rutherford type cable splices for Torus magnet for the Jefferson Lab 12 GeV Upgrade

The Hall B 3.6-T superconducting torus magnet is being designed and built as part of the Jefferson Lab 12-GeV upgrade. The magnet consists of six trapezoidal coils connected in series, with an operating current of 3770 A. The magnet and the joints (or splices) connecting the coils are all conduction cooled by supercritical 4.6-K helium. This paper studies the design and manufacturing process of the splices made between two SSC Rutherford-type cables and discusses the tests performed to evaluate the performance of the splices under varying incident magnetic fields.

Ghoshal, Probir K.↗

Conceptual Design of a 17 T Nb$_3$Sn Accelerator Dipole Magnet

$Nb_3Sn$ dipole magnets with a nominal field of 16 T and sufficient operation margins are being considered for the LHC energy upgrade or a future Very High Energy Hadron Collider. This paper describes the conceptual design of a 17 T dipole magnet with 60 mm aperture, 4-layer cos-theta coil and stress management techniques.

43 PARTICLE ACCELERATORS↗

Cold Mass Issues in the MICE Coupling Magnet

I have identified two potential issues in the design of the attachments to the MICE coupling magnet cold mass. One of these attachment issues may extend into the cold mass. Both issues came to light during the analysis of what happened to the spectrometer solenoids. We must not make the same mistakes that were made on the spectrometer solenoids. The two questions that result from the identified issues are; 1) Are the superconducting low temperature superconducting leads between the coupling coil and the lower end of the high temperature superconducting (LTS) leads robust enough not quench and burn out? In the spectrometer solenoid one part of the LTS lead was not robust enough to prevent quenching and a burn out of the LTS lead and ; 2) Will there be problems with the quench protection resistors and diodes when the magnet quenches as a result of an HTS lead burning out or a disconnect of the magnet from its power supply? The second question is very important because the coupling coil has a large stored energy and inductance. As result, when current flows through the diodes and the resistors, both can be over heated. We observed resistor overheating in spectrometer magnet 2. This heating probably happened when the HTS lead the LTS lead burned out during the tests of magnet 2A and 2B respectively. (See MICE Note 324.) The answer to the first question is simple and straightforward. This is the issue that is primarily dealt with in MICE Note 324. If the resistance across the coil sub-divisions is high enough, the whole magnet will turn normal through quench-back. Making the resistance across a coil sub-division high enough is not simple.

43 PARTICLE ACCELERATORS↗

Ultra-low field nuclear magnetic resonance and magnetic resonance imaging to discriminate and identify materials

Method comprising obtaining an NMR measurement from a sample wherein an ultra-low field NMR system probes the sample and produces the NMR measurement and wherein a sampling temperature, prepolarizing field, and measurement field are known; detecting the NMR measurement by means of inductive coils; analyzing the NMR measurement to obtain at least one measurement feature wherein the measurement feature comprises T1, T2, T1.rho., or the frequency dependence thereof; and, searching for the at least one measurement feature within a database comprising NMR reference data for at least one material to determine if the sample comprises a material of interest.

36 MATERIALS SCIENCE↗