RF Results of Nb Coated SRF Accelerator Cavities via HiPIMS

Bulk Niobium (Nb) SRF (superconducting radio frequency) cavities are currently the preferred method for acceleration of charged particles at accelerator facilities around the world. However, bulk Nb cavities have poor thermal conductance and impose material and design restrictions on other components of a particle accelerator. Since the SRF phenomena occurs within a shallow depth of 40 nm (for Nb), a proposed solution to this problem has been to deposit a superconducting Nb thin film on the interior of a cavity made of a suitable alternative material such as copper or aluminum. While this approach has been attempted in the past using DC magnetron sputtering (DCMS), such cavities have never performed at the bulk Nb level. However, new energetic condensation techniques for film deposition offer the opportunity to create suitably thick Nb films with improved density, microstructure and adhesion compared to traditional DCMS. One such technique that has been developed somewhat recently is ?High Power Impulse Magnetron Sputtering? (HiPIMS). Here we report early results from various thin film coatings carried out on 1.3 GHz Cu cavities, a 1.5 GHz Nb cavity, and small Cu coupon samples coated at Jefferson Lab using HiPIMS.

Burton, Matthew Creed↗

AN OVERVIEW OF PLASMA PROCESSING OF SRF CAVITIES AT JLAB

Plasma processing is a common technique where the free oxygen produced in a low-pressure RF plasma breaks down and removes hydrocarbons from surfaces. This increases the work function and reduces the secondary emission coefficient of the treated surfaces. Jefferson Lab has an ongoing R&D program in plasma processing. The experimental program investigated processing using argon/oxygen and helium/oxygen gas mixtures. The initial focus of the effort was processing C100 cavities by injecting RF power into the HOM coupler ports. We also developed the methods for establishing a plasma C75 cavities where the RF power is injected via the fundamental power-coupler. As part of the process development we processed, three C100 cryomodules in our off-line cryomodule test facility. In May 2023 we processed four C100 cryomodules in-situ in the CEBAF accelerator with the cryomodules returning to an operational status in Sept. 2023. The cumulative improvement in field emission free operation, as measured on a cavity by cavity basis, was 59 MeV or 24%. We recently started processing 7 cryomodules in the CEBAF accelerator in August 2024. Methods systems and results from processing cryomodules and individual cavities in the vertical test will be presented. Current status and future plans will also be presented.

Ganey, Tiffany↗

Simulation Study on JLEIC High Energy Bunched Electron Cooling

In the Jefferson Lab (JLab) Electron Ion Collider (JLEIC) project the traditional electron cooling technique is used to reduce the ion beam emittance at the booster ring, and to compensate the intrabeam scattering effect and maintain the ion beam emittance during the collision at the collider ring. Different with other electron coolers using DC electron beam, the proposed electron cooler at the JLEIC ion collider ring uses high energy bunched electron beam, provided by an ERL. In this paper, we report the new electron cooling simulation program developed at JLab to fulfil specific simulation requirements of JLEIC and some recent simulation study on how the electron cooling rate will be affected by the bunched electron beam properties, such as the correlation between the longitudinal position and momentum, the bunch size, and the Larmor emittance.

Zhang, He↗

The US Electron Ion Collider Accelerator Designs

With the completion of the National Academies of Sciences Assessment of a US Electron-Ion Collider, the prospects for construction of such a facility have taken a step forward. This paper provides an overview of the two site-specific EIC designs: JLEIC (Jefferson Lab) and eRHIC (BNL) as well as brief overview of ongoing EIC R&D.

43 PARTICLE ACCELERATORS↗

MAGNETIZED ELECTRON SOURCE FOR JLEIC COOLER

Magnetized bunched-beam electron cooling is a critical part of the Jefferson Lab Electron Ion Collider (JLEIC). Strong cooling of ion beams will be accomplished inside a cooling solenoid where the ions co-propagate with an electron beam generated from a source immersed in a magnetic field. This contribution describes the production and characterization of magnetized electron beam using a compact 300 kV DC high voltage photogun and bialkali-antimonide photocathodes. Beam magnetization was studied using a diagnostic beamline that includes viewer screens for measuring the shearing angle of the electron beamlet passing through a narrow upstream slit. Correlated beam emittance with magnetic field (0-1.5 kG)at the photocathode was measured for various laser spot sizes. Measurements of photocathode lifetime were carried out at different magnetized electron beam currents up to 28 mA and high bunch charge up to 0.7 nano-Coulomb was demonstrated.

Suleiman, R.↗

The Latest Code Development Progress of JSPEC

The JLab Simulation Package on Electron Cooling (JSPEC) is an open source software developed at Jefferson Lab for electron cooling and intrabeam scattering (IBS) simulations. IBS is an important factor that leads to the growth of the beam emittance and hence the reduction of the luminosity in a high density ion collider ring. Electron cooling is an effective measure to overcome the IBS effect. Although JSPEC is initiated to fulfill the simulation needs in JLab Electron Ion Collider project, it can be used as a general design tool for other accelerators. JSPEC provides various models of the ion beam and the electron beam and it calculates the expansion rate and simulates the evolution of the ion beam under the IBS and/or electron cooling effect. In this report, we will give a brief introduction of JSPEC and then present the latest code development progress of JSPEC, including new models, algorithms, and the user interface.

Zhang, Y.↗

Multipole effects on dynamic aperture in JLEIC ion collider ring

In a collider, stronger focusing at the interaction point (IP) for low beta-star and high luminosity produces large beams at final focusing quadrupoles (FFQs). To achieve the high luminosity requirement in the Jefferson Lab Electron-Ion Collider (JLEIC), the interaction region (IR) beta functions peak at ~4.2 km in downstream FFQs. These large beta functions and FFQ multipoles reduce the dynamic aperture (DA) of the ring. A study of the multipole effects on the DA was performed to determine limits on multipoles, and to include a multipole compensation scheme to increase the DA and beam lifetime.

Rajput-Ghoshal, Renuka↗

Simulation of Transparent Spin Experiment in RHIC

The transparent spin mode has been proposed as a new technique for preservation and control of the spin polarization of an ion beam in a synchrotron. The ion rings of the proposed Jefferson Lab Electron-Ion Collider adopted this technique in their figure-8 design. The transparent spin mode can also be setup in a racetrack with two identical Siberian snakes. There is a proposal to test the predicted features of the spin transparent mode in RHIC, which already has all of the necessary hardware capabilities. We have earlier analytically estimated the setup parameters and developed a preliminary experimental plan. In this paper we describe simulations of the proposed experiment using a Zgoubi model of RHIC. We present simulation of the polarization preservation during acceleration in the transparent spin mode. We also demonstrate polarization control by simulating an adiabatic polarization adjustment. A procedure to measure the strength of the spin transparent resonance is illustrated.

Morozov, Vasiliy↗

In Situ Plasma Processing of Superconducting Cavities at JLab

Jefferson Lab has an ongoing R&D program in plasma processing which is close to going into production pro-cessing in the CEBAF accelerator. Plasma processing is a common technique for removing hydrocarbons from surfaces, which increases the work function and reduces the secondary emission coefficient[1]. The initial focus of the effort is processing C100 cavities by injecting RF power into the HOM coupler ports. The goal will be to improve the operational gradients and the energy margin of the CEBAF linacs by processing cryomodules in situ. Results from processing cryomodule in the cryomodule test bunker as well as vertical test results will be present-ed. This work will describe the systems and methods used at JLAB for processing cavities using an argon oxygen gas mixture. Before and after plasma processing results will also be presented.

Powers, T.↗

A 500 KV INVERTED GEOEMTRY FEEDTHROUGH FOR A HIGH VOLT-AGE DC ELECTRON GUN

The Continuous Electron Beam Accelerator Facility injector at Jefferson Lab (JLab) utilizes an inverted-geometry ceramic insulator photogun operating at 130 kV direct current to generate spin-polarized electron beams for high-energy nuclear physics experiments. A second photogun delivers 180 keV beam for commissioning a SRF booster in a testbed accelerator, and a larger version delivers 300 keV magnetized beam in a test stand beam line. This contribution reports on the development of an unprecedented inverted-insulator with cable connector for reliably applying 500 kV DC to a future polarized beam photogun, to be designed for operating at 350 kV without field emission. Such a photogun design could then be used for generating a polarized electron beam to drive a spin-polarized positron source as a demonstrator for high energy nuclear physics at JLab. There are no commercial cable connectors that fit the large inverted insulators required for that voltage range. Our proposed concept is based on a modified epoxy receptacle with intervening SF6 layer and a test electrode in a vacuum vessel.

Hernandez-Garcia, C.↗

pyJSPEC - A Python Module for IBS and Electron Cooling Simulation

The intrabeam scattering is an important collective effect that can deteriorate the property of a high-intensity beam and electron cooling is a method to mitigate the IBS effect. JSPEC (JLab Simulation Package on Electron Cooling) is an open-source C++ program developed at Jefferson Lab, which simulates the evolution of the ion beam under the IBS and/or the electron cooling effect. The Python wrapper of the C++ code, pyJSPEC, for Python 3.x environment has been recently developed and released. It allows the users to run JSPEC simulations in a Python environment. It also makes it possible for JSPEC to collaborate with other accelerator and beam modeling programs as well as plentiful python tools in data visualization, optimization, machine learning, etc. In this paper, we will introduce the features of pyJSPEC and demonstrate how to use it with sample codes and numerical results.

Zhang, H.↗

MAGNETIC HYGIENE CONTROL ON LCLS-II CRYOMODULES FABRICATED AT JLAB

Jefferson Lab (JLab) is in collaboration with Fermi Na-tional Accelerator Laboratory (Fermilab) to build 18 cryomodules to install at the SLAC National Accelerator Laboratory?s tunnel as part of the Linac Coherent Light Source upgrade project (LCLS-II). Each LCLS-II cry-omodule hosts 8 superconducting niobium cavities that adopt the nitrogen doping technique, which aims to en-hance the cavity quality factor Qo to reduce the consumption of liquid helium used to cool down the cavities. It is known that the Qo of niobium cavities is affected by cavity surface magnetic field. Traditionally, magnetic shields made of high magnetic permeability mu-metals are employed as a passive shielding of the ambient magnetic fluxes. During the LCLS-II cryomodule development, magnetic hygiene control that includes magnetic shielding and demagnetization of parts and the whole-machine is implemented. JLab and Fermilab worked closely on developing magnetic hygiene control procedures, identifying relevant tools, investigating causes of magnetization, magnetic field monitoring, etc. This paper focuses on JLab?s experiences with LCLS-II cryomodule magnetic hygiene control during its fabrication.

Cheng, Guangfeng↗

JLab New Injector Cryomodule Design, Fabrication and Testing

A new Injector Cryomodule (INJ CM) aimed to replace the existing Quarter Cryomodule in the CEBAF tunnel has been developed at Jefferson Lab (JLab). It is scheduled to be first tested in the Cryomodule Test Facility (CMTF) for module performance then the Upgraded Injector Test Facility (UITF) with electron beam. This new cryomodule, hosting a 2-cell and 7-cell cavity, is designed to boost the electron energy from 200 keV to 5 MeV and permit 380 ?A ? 1.0 mA of beam current. The 2-cell cavity is a new design whereas the 7-cell cavity is refurbished from a low loss cavity from the retired JLab Renascence Cryomodule. The INJ CM adopts quite a few designs from the JLab 12 GeV Upgrade Cryomodule (C100). Examples of this include having the cold mass hung from a spaceframe structure by use of axial and transverse Nitronic rods, cavities to be tuned by scissor-jack style tuners and the end cans are actually modified from C100 style end cans. However, this new INJ CM is not a quarter of the C100 Cryomodule. This paper focuses on the major design features, fabrication and alignment process and testing of the module and its components.

Cheng, Guangfeng↗

Standardized beamline particulate characterization analysis: Initial application to CEBAF and LCLS-II cryomodule components

Despite continuously evolving efforts to minimize and manage the occurrence of particulates in operational SRF accelerator systems, the presence of electron field emission from contaminating particulates on SRF surfaces with high surface electric fields remains a consistent challenge. Jefferson Lab has recently initiated a standardized particulate sampling and characterization practice in order to gain more specific and systematic knowledge of the particulates actually present. It is expected that patterns emerging from such sampling will strengthen source attribution and guide improvement efforts. Initial samples were gathered from a cryomodule and adjoining warm girders that were removed from the CEBAF tunnel for reprocessing. The collection and analysis techniques were also used to characterize particulates on the inside of LCLS-II string components. Samples are transferred to clean industry-standard forensic GSR carbon tape spindles and examined via automated cleanroom SEM scanning for particle localization trends and sizing. The particulates are subsequently analyzed with EDS for elemental composition. A catalogue of found particle types is being accumulated. The methods used and results obtained from these initial applications will be presented.

Reece, Charles↗

UPGRADES TO CRYOGENIC CAPABILITIES FOR CRYOMODULE TESTING AT JLAB

The cryogenic facilities for cryomodule testing at Jefferson Lab (JLab) have been modified and to enable testing of Linear Coherent Light Source-II (LCLS-II) cryomodules. Temporary changes in u-tube connec-tions at the Cryogenic Test Facility (CTF) has enabled rates of cavity cooling that are a factor of 10 higher than previously achieved. Cryogenic connections at JLab?s Low Energy Recirculator Facility (LERF) have been repurposed to enable two LCLS-II cryomodules to be tested in series. This testing shares the helium space with the Central Helium Liquefier (CHL) that is also used by the Continuous Electron Beam Accelera-tor Facility (CEBAF). Cryomodule testing can occur while beam operation is ongoing at CEBAF. Improve-ments to these facilities have allowed the testing of the JLab?s highest ever performing cryomodules.

Huque, Naeem↗

MICROPHONICS TESTING OF LCLS II CRYOMODULES AT JLAB

Jefferson Lab is partnering with Fermilab to build 40 cryomodules for the LCLS II accelerator that will be installed at the Stanford Linear Accelerator (SLAC). The LCLS II cryomodule is an 8-seat CW cryomodule which operates at 1300 MHz and is based on the XFEL design. The cavities have design loaded-Q of 4×107, which means that it has a control bandwidth of 16 Hz. The JLab prototype cryomodule was instrumented with a series of 10 accelerometers, and impulse hammer response measurements were made while the cryomodule was being built and after it was installed in the JLAB cryomodule test facility. This was done so that we could better understand the shapes of the modes of the structure. These results were compared to impulse hammer testing from the outside of the cryomodule to individual cavity frequency shifts when the cryomodule was cold. Additionally, background microphonics and transfer function measurements were made on several other LCLS II cryomodules in the JLab cryomodule test facility (CMTF). The prototype cryomodule had excessive microphonics up to 100 Hz peak due to a thermo-acoustic oscillation in the cryogenic supply circuit. Design modifications were implemented and subsequently the cryomodules had microphonics on the order of 10 to 20 Hz.

Powers, Thomas↗

Improvements to LCLS-II Cryomodule Transportation

The Linear Coherent Light Source (LCLS-II) is currently being constructed at the SLAC National Laboratory. A total of 35 cryomodules will be fabricated at Jefferson Lab (JLab) in Virginia and Fermi National Laboratory (FNAL) in Illinois and transported via road to SLAC. A shipping frame with an inner bed isolated by springs was designed to protect the CMs from shocks and vibrations during shipments. Successful road testing of the JLab prototype paved the way for production CM shipments. The initial production shipments lead to several catastrophic failures in beamline vacuum in the cryomodules. The failures were determined to be due to fatigue in Fundamental Power Coupler (FPC) bellows due to excessive motion during shipment. A series of instrumented CM shipping tests and component tests were undertaken to develop a solution. A modified spring layout was tested and implemented, which reduced shocks on the CMs. FPC coupler bellows restraints were tested on a shaker table and on a CM during shipping; they were able to reduce bellows motion by a factor of three. The updated shipping system is currently in use and has successfully delivered six cryomodules to SLAC from JLab and FNAL.

43 PARTICLE ACCELERATORS↗

LCLS-II Cryomodules Production Experience and Lessons Learned at Fermilab

LCLS-II is a planned upgrade project for the linear co-herent light source (LCLS) at SLAC. The LCLS-II Linac will consist of thirty-five 1.3 GHz and two 3.9 GHz super-conducting RF continuous wave (CW) cryomodules that Fermilab and Jefferson Lab are currently producing in collaboration with SLAC. The LCLS-II 1.3 GHz cryomodule design is based on the European XFEL pulsed-mode cryomodule design with modifications needed for CW opera-tion. Two prototype cryomodules had been assembled and tested. After prototype cryomodule tests, both laboratories have increased their cryomodule production rate to meet the challenging LCLS-II project installation schedule requirements of approximately one cryomodule per month per laboratory. To date, Fermilab has completed the assembly and testing of eighteen 1.3GHz cryomodules. Fermilab has successfully shipped nine cryomodules to SLAC and will continue to ship approximately every two weeks. The first 3.9 GHz cryomodule assembly is scheduled to start in June 2019. Production readiness verifications are currently in process. This paper presents LCLS-II 1.3GHz cryomodule assembly and production experience, emphasizing the challenges, mitigations, and lessons learned.

43 PARTICLE ACCELERATORS↗