Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ion Engine”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Structural Basis of Substrate Specificity and Regiochemistry in the MycF/TylF Family of Sugar O -Methyltransferases.

Sugar moieties in natural products are frequently modified by O-methylation. In the biosynthesis of the macrolide antibiotic mycinamicin, methylation of a 6'-deoxyallose substituent occurs in a stepwise manner first at the 2'- and then the 3'-hydroxyl groups to produce the mycinose moiety in the final product. The timing and placement of the O-methylations impact final stage C-H functionalization reactions mediated by the P450 monooxygenase MycG. The structural basis of pathway ordering and substrate specificity is unknown. A series of crystal structures of MycF, the 3'-O-methyltransferase, including the free enzyme and complexes with S-adenosyl homocysteine (SAH), substrate, product, and unnatural substrates, show that SAM binding induces substantial ordering that creates the binding site for the natural substrate, and a bound metal ion positions the substrate for catalysis. A single amino acid substitution relaxed the 2'-methoxy specificity but retained regiospecificity. The engineered variant produced a new mycinamicin analog, demonstrating the utility of structural information to facilitate bioengineering approaches for the chemoenzymatic synthesis of complex small molecules containing modified sugars. Using the MycF substrate complex and the modeled substrate complex of a 4'-specific homolog, active site residues were identified that correlate with the 3'- or 4'- specificity of MycF family members and define the protein and substrate features that direct the regiochemistry of methyltransfer. Lastly, this classification scheme will be useful in the annotation of new secondary metabolite pathways that utilize this family of enzymes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three-dimensional Zn-based alloys for dendrite-free aqueous Zn battery in dual-cation electrolytes

Aqueous zinc-ion batteries, in terms of integration with high safety, environmental benignity, and low cost, have attracted much attention for powering electronic devices and storage systems. However, the interface instability issues at the Zn anode caused by detrimental side reactions such as dendrite growth, hydrogen evolution, and metal corrosion at the solid (anode)/liquid (electrolyte) interface impede their practical applications in the fields requiring long-term performance persistence. Despite the rapid progress in suppressing the side reactions at the materials interface, the mechanism of ion storage and dendrite formation in practical aqueous zinc-ion batteries with dual-cation aqueous electrolytes is still unclear. Herein, we design an interface material consisting of forest-like three-dimensional zinc-copper alloy with engineered surfaces to explore the Zn plating/stripping mode in dual-cation electrolytes. The three-dimensional nanostructured surface of zinc-copper alloy is demonstrated to be in favor of effectively regulating the reaction kinetics of Zn plating/stripping processes. The developed interface materials suppress the dendrite growth on the anode surface towards high-performance persistent aqueous zinc-ion batteries in the aqueous electrolytes containing single and dual cations. This work remarkably enhances the fundamental understanding of dual-cation intercalation chemistry in aqueous electrochemical systems and provides a guide for exploring high-performance aqueous zinc-ion batteries and beyond.

25 ENERGY STORAGE↗

Data and Code for Atomic Scale Etching of Diamond: Insights from Molecular Dynamics Simulations

This work investigates the effects of argon ions, hydrogen atoms, and hydrogen ions on the diamond (100) surface using classical molecular dynamics simulations. The purpose of this investigation was to asses plasma processing techniques for applications in quantum device manufacturing. The simulations suggest that combining argon ion smoothing with selective, near threshold energy H removal of amorphous C could be an effective strategy for diamond surface engineering, leading to more reliable and sensitive diamond color center devices. Results were found to differ significantly with interatomic potential, and an analysis of these differences was also carried out. Included in this repository are LAMMPS source files, input scripts, and plotting scripts required to reproduce the data. Also included are the output data required to make all the plots included in the associated publication.

Brenner↗

Sample Preparation and Experimental Design for In Situ Multi-Beam Transmission Electron Microscopy Irradiation Experiments

We discuss the need to understand materials exposed to overlapping extreme environments such as high temperature, radiation, or mechanical stress. When these stressors are combined there may be synergistic effects that enable unique microstructural evolution mechanisms to activate. Understanding of these mechanisms is necessary for the input and refinement of predictive models and critical for engineering of next generation materials. The basic physics and underlying mechanisms require advanced tools to be investigated. The in situ ion irradiation transmission electron microscope (I 3 TEM) is designed to explore these principles. To quantitatively probe the complex dynamic interactions in materials, careful preparation of samples and consideration of experimental design is required. Particular handling or preparation of samples can easily introduce damage or features that obfuscate the measurements. There is no one correct way to prepare a sample; however, many mistakes can be made. The most common errors and things to consider are highlighted within. The I 3 TEM has many adjustable variables and a large potential experimental space, therefore it is best to design experiments with a specific scientific question or questions in mind. Experiments have been performed on large number of sample geometries, material classes, and with many irradiation conditions. The following are a subset of examples that demonstrate unique in situ capabilities utilizing the I 3 TEM. Au nanoparticles prepared by drop casting have been used to investigate the effects of single ion strikes. Au thin films have been used in studies on the effects of multibeam irradiation on microstructure evolution. Zr films have been exposed to irradiation and mechanical tension to examine creep. Ag nanopillars were subjected to simultaneous high temperature, mechanical compression, and ion irradiation to study irradiation induced creep as well. These results impact fields including: structural materials, nuclear energy, energy storage, catalysis, and microelectronics in space environments.

47 OTHER INSTRUMENTATION↗

Shuttle Tethered Aerothermodynamics Research Facility (STARFAC) Instrumentation Requirements

The instrumentation requirements for the Shuttle Tethered Aerothermodynamic Research Facility (STARFAC) are presented. The typical physical properties of the terrestrial atmosphere are given along with representative atmospheric daytime ion concentrations and the equilibrium and nonequilibrium gas property comparison from a point away from a wall. STARFAC science and engineering measurements are given as are the TSS free stream gas analysis. The potential nonintrusive measurement techniques for hypersonic boundary layer research are outlined along with the quantitative physical measurement methods for aerothermodynamic studies.

Wood, George M.↗

Electric propulsion options for 10 kW class earth space missions

Five and 10 kW ion and arcjet propulsion system options for a near-term space demonstration experiment have been evaluated. Analyses were conducted to determine first-order propulsion system performance and system component mass estimates. Overall mission performance of the electric propulsion systems was quantified in terms of the maximum thrusting time, total impulse, and velocity increment capability available when integrated onto a generic spacecraft under fixed mission model assumptions. Maximum available thrusting times for the ion-propelled spacecraft options, launched on a DELTA II 6920 vehicle, range from approximately 8,600 hours for a 4-engine 10 kW system to more than 29,600 hours for a single-engine 5 kW system. Maximum total impulse values and maximum delta-v's range from 1.2x10(7) to 2.1x10(7) N-s, and 3550 to 6200 m/s, respectively. Maximum available thrusting times for the arcjet propelled spacecraft launched on the DELTA II 6920 vehicle range from approximately 528 hours for the 6-engine 10 kW hydrazine system to 2328 hours for the single-engine 5 kW system. Maximum total impulse values and maximum delta-v's range from 2.2x10(6) to 3.6x10(6) N-s, and approximately 662 to 1072 m/s, respectively.

Patterson, M. J.↗

Electric Propulsion Options for 10 kW Class Earth-Space Missions

Five and 10 kW ion and arcjet propulsion system options for a near-term space demonstration experiment were evaluated. Analyses were conducted to determine first-order propulsion system performance and system component mass estimates. Overall mission performance of the electric propulsion systems was quantified in terms of the maximum thrusting time, total impulse, and velocity increment capability available when integrated onto a generic spacecraft under fixed mission model assumptions. Maximum available thrusting times for the ion-propelled spacecraft options, launched on a DELTA 2 6920 vehicle, range from approximately 8,600 hours for a 4-engine 10 kW system to more than 29,600 hours for a single-engine 5 kW system. Maximum total impulse values and maximum delta-v's range from 1.2x10 (exp 7) to 2.1x10 (exp 7) N-s, and 3550 to 6200 m/s, respectively. Maximum available thrusting times for the arcjet propelled spacecraft launched on the DELTA 2 6920 vehicle range from approximately 528 hours for the 6-engine 10 kW hydrazine system to 2328 hours for the single-engine 5 kW system. Maximum total impulse values and maximum delta-v's range from 2.2x10 (exp 6) to 3.6x10 (exp 6) N-s, and approximately 662 to 1072 m/s, respectively.

Patterson, M. J.↗

NASA Tech Briefs, January 2006

Topics covered include: Semiautonomous Avionics-and-Sensors System for a UAV; Biomimetic/Optical Sensors for Detecting Bacterial Species; System Would Detect Foreign-Object Damage in Turbofan Engine; Detection of Water Hazards for Autonomous Robotic Vehicles; Fuel Cells Utilizing Oxygen From Air at Low Pressures; Hybrid Ion-Detector/Data-Acquisition System for a TOF-MS; Spontaneous-Desorption Ionizer for a TOF-MS; Equipment for On-Wafer Testing From 220 to 325 GHz; Computing Isentropic Flow Properties of Air/R-134a Mixtures; Java Mission Evaluation Workstation System; Using a Quadtree Algorithm To Assess Line of Sight; Software for Automated Generation of Cartesian Meshes; Optics Program Modified for Multithreaded Parallel Computing; Programs for Testing Processor-in-Memory Computing Systems; PVM Enhancement for Beowulf Multiple-Processor Nodes; Ion-Exclusion Chromatography for Analyzing Organics in Water; Selective Plasma Deposition of Fluorocarbon Films on SAMs; Water-Based Pressure-Sensitive Paints; System Finds Horizontal Location of Center of Gravity; Predicting Tail Buffet Loads of a Fighter Airplane; Water Containment Systems for Testing High-Speed Flywheels; Vapor-Compression Heat Pumps for Operation Aboard Spacecraft; Multistage Electrophoretic Separators; Recovering Residual Xenon Propellant for an Ion Propulsion System; Automated Solvent Seaming of Large Polyimide Membranes; Manufacturing Precise, Lightweight Paraboloidal Mirrors; Analysis of Membrane Lipids of Airborne Micro-Organisms; Noninvasive Diagnosis of Coronary Artery Disease Using 12-Lead High-Frequency Electrocardiograms; Dual-Laser-Pulse Ignition; Enhanced-Contrast Viewing of White-Hot Objects in Furnaces; Electrically Tunable Terahertz Quantum-Cascade Lasers; Few-Mode Whispering-Gallery-Mode Resonators; Conflict-Aware Scheduling Algorithm; and Real-Time Diagnosis of Faults Using a Bank of Kalman Filters.

Source record↗

Small Column Ion Exchange Design and Safety Strategy

Small Column Ion Exchange (SCIX) is a transformational technology originally developed by the Department of Energy (DOE) Environmental Management (EM-30) office and is now being deployed at the Savannah River Site (SRS) to significantly increase overall salt processing capacity and accelerate the Liquid Waste System life-cycle. The process combines strontium and actinide removal using Monosodium Titanate (MST), Rotary Microfiltration, and cesium removal using Crystalline Silicotitanate (CST, specifically UOP IONSIV{reg_sign}IE-911 ion exchanger) to create a low level waste stream to be disposed in grout and a high level waste stream to be vitrified. The process also includes preparation of the streams for disposal, e.g., grinding of the loaded CST material. These waste processing components are technically mature and flowsheet integration studies are being performed including glass formulations studies, application specific thermal modeling, and mixing studies. The deployment program includes design and fabrication of the Rotary Microfilter (RMF) assembly, ion-exchange columns (IXCs), and grinder module, utilizing an integrated system safety design approach. The design concept is to install the process inside an existing waste tank, Tank 41H. The process consists of a feed pump with a set of four RMFs, two IXCs, a media grinder, three Submersible Mixer Pumps (SMPs), and all supporting infrastructure including media receipt and preparation facilities. The design addresses MST mixing to achieve the required strontium and actinide removal and to prevent future retrieval problems. CST achieves very high cesium loadings (up to 1,100 curies per gallon (Ci/gal) bed volume). The design addresses the hazards associated with this material including heat management (in column and in-tank), as detailed in the thermal modeling. The CST must be size reduced for compatibility with downstream processes. The design addresses material transport into and out of the grinder and includes provisions for equipment maintenance including remote handling. The design includes a robust set of nuclear safety controls compliant with DOE Standard (STD)-1189, Integration of Safety into the Design Process. The controls cover explosions, spills, boiling, aerosolization, and criticality. Natural Phenomena Hazards (NPH) including seismic event, tornado/high wind, and wildland fire are considered. In addition, the SCIX process equipment was evaluated for impact to existing facility safety equipment including the waste tank itself. SCIX is an innovative program which leverages DOE's technology development capabilities to provide a basis for a successful field deployment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fast and low-cost method to fabricate large-area superhydrophobic surface on steel substrate with anticorrosion and anti-icing properties

A facile and quick fabrication method was proposed to prepare superhydrophobic surfaces on iron substrate by chemical immersion and subsequent stearic acid modification. The association between wettability and surface morphology was studied through altering the copper ion concentration and immersion time. Surface tension instrument, scanning electron microscopy, x-ray diffraction, x-ray photoelectron spectroscopy, and electrochemical workstation were used to characterize the wettability, physical morphology, chemical composition, and corrosion resistance ability of the prepared film. Results showed that both the rough micro/nanostructures and low surface energy material play critical roles in surface wettability. The superhydrophobic film achieved a better anticorrosion property compared to barrier iron by analysis of open circuit potential, potentiodynamic polarization curves, and Nyquist plots. In addition, the superhydrophobic surface showed excellent performance of acid and alkali resistance, anti-icing, and self-cleaning through a series of environmental tests. This study provides a valid method for quick-preparation of the stable superhydrophobic surfaces, which has a promising application in steel buildings and facilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chimera Spectrum Diagnostics for Peptides Using Two-Dimensional Partial Covariance Mass Spectrometry

The rate of successful identification of peptide sequences by tandem mass spectrometry (MS/MS) is adversely affected by the common occurrence of co-isolation and co-fragmentation of two or more isobaric or isomeric parent ions. This results in so-called `chimera spectra’, which feature peaks of the fragment ions from more than a single precursor ion. The totality of the fragment ion peaks in chimera spectra cannot be assigned to a single peptide sequence, which contradicts a fundamental assumption of the standard automated MS/MS spectra analysis tools, such as protein database search engines. This calls for a diagnostic method able to identify chimera spectra to single out the cases where this assumption is not valid. Here, we demonstrate that, within the recently developed two-dimensional partial covariance mass spectrometry (2D-PC-MS), it is possible to reliably identify chimera spectra directly from the two-dimensional fragment ion spectrum, irrespective of whether the co-isolated peptide ions are isobaric up to a finite mass accuracy or isomeric. We introduce ‘3-57 chimera tag’ technique for chimera spectrum diagnostics based on 2D-PC-MS and perform numerical simulations to examine its efficiency. We experimentally demonstrate the detection of a mixture of two isomeric parent ions, even under conditions when one isomeric peptide is at one five-hundredth of the molar concentration of the second isomer.

47 OTHER INSTRUMENTATION↗

Application of nitrogen plasma immersion ion implantation to titanium nasal implants with nanonetwork surface structure

In nasal reconstruction, the response of cells to titanium (Ti) implants is mainly determined by surface features of the implant. In a pilot study, the authors applied electrochemical anodization to Ti surfaces in an alkaline solution to create a network of nanoscale surface structures. This nanonetwork was intended to enhance the responses of primary human nasal epithelial cell (HNEpC) to the Ti surface. In this study, the authors then treated the anodized, nanonetwork-structured Ti surface using nitrogen plasma immersion ion implantation (NPIII) in order to further improve the HNEpC response to the Ti surface. Subsequently, surface characterization was performed to elucidate morphology, roughness, wettability, and chemistry of specimens. Cytotoxicity, blood, and HNEpC responses were also evaluated. Our results demonstrate that NPIII treatment led to the formation of a noncytotoxic TiN-containing thin film (thickness <100 nm) on the electrochemically anodized Ti surface with a nanonetwork-structure. NPIII treatment was shown to improve blood clotting and the adhesion of platelets to the anodized Ti surface as well as the adhesion and proliferation of hNEpC. This research spreads our understanding of the fact that a TiN-containing thin film, produced using NPIII treatment, could be used to improve blood and HNEpC responses to anodized, nanonetwork-structured Ti surfaces in nasal implant applications.

42 ENGINEERING↗

Investigating PID Shunting in Polycrystalline CIGS Devices via Multi-Scale, Multi-Technique Characterization

We investigated potential-induced degradation (PID) in CuIn 1-x Ga x Se 2 (CIGS) mini-modules stressed in the laboratory. Small cores were removed from the modules and were subjected to analysis. We completed a proof-of-concept correlative study relating cathodoluminescence to sodium content via time-of-flight secondary-ion mass spectrometry imaging. By comparing one-dimensional depth profile results and three-dimensional tomography results on stressed and unstressed CIGS mini-modules, we can see that PID in CIGS results from sodium migration through absorber, most likely via grain boundaries. Potassium concentration distributions show little change when adding a voltage bias to a temperature and humidity stress. This suggests doping with other large alkali ions, such as cesium and rubidium, rather than sodium can increase the PID resistance of CIGS modules.

14 SOLAR ENERGY↗

Determination of the characteristic magnetic pre-sheath length at divertor surfaces using micro-engineered targets on DiMES at DIII-D

The magnetic pre-sheath (MPS) width, L MPS , is a critical parameter to define the sheath potential, which controls the ion trajectory of low-Z species (D, T, He, and C), as well as the prompt re-deposition of high-Z species. In this work, to determine L MPS , we fabricated micro-trenches (30×30×4 µm) via focused ion beam (FIB) milling on a silicon surface and exposed them to L-mode deuterium plasmas in DIII-D via the Divertor Material Evaluation System (DiMES) removable sample exposure probe. The areal distribution of impurity depositions, mainly consisting of carbon, was measured by energy-dispersive X-ray spectroscopy (EDS) to reveal the deuterium ion shadowing effect on the trench floors. The carbon deposition profiles showed that the erosion was maximized for the azimuthal direction of φ = -40° (referenced to the toroidal magnetic field direction) as well as the polar angle of θ = 80°. A Monte Carlo equation-of-motion model, based on a collisionless MPS, was used to calculate the azimuthal and polar deuterium ion angle distributions (IADs) for a range of L MPS = k × ρ i , where ρ i is the ion gyro radius and k = 0.5-4. Then, gross erosion profiles were calculated by a Monte Carlo micro-patterning and roughness (MPR) code for ion sputtering using as input the calculated azimuthal and polar IADs for each value of k . Good agreement with the experimental C deposition profiles was obtained for the case k = 2.5-3.5. This result is consistent with a previous kinetic modeling prediction of k ~ 3, as well as previous analytical investigations that predicted the L MPS to be several ion gyro radii. A validation of theoretical sheath models supports its applicability to ITER and pilot plant divertors to successfully predict plasma-materials interactions.

Erosion↗

Model-Based Design and Integration of Large Li-ion Battery Systems

This presentation introduces physics-based models of batteries and software toolsets, including those developed by the U.S. Department of Energy's (DOE) Computer-Aided Engineering for Electric-Drive Vehicle Batteries Program (CAEBAT). The presentation highlights achievements and gaps in model-based tools for materials-to-systems design, lifetime prediction and control.

33 ADVANCED PROPULSION SYSTEMS↗