Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Computational 3D histological phenotyping of whole zebrafish by X-ray histotomography

Organismal phenotypes frequently involve multiple organ systems. Histology is a powerful way to detect cellular and tissue phenotypes, but is largely descriptive and subjective. To determine how synchrotron-based X-ray micro-tomography (micro-CT) can yield 3-dimensional whole-organism images suitable for quantitative histological phenotyping, we scanned whole zebrafish, a small vertebrate model with diverse tissues, at ~1 micron voxel resolutions. Micro-CT optimized for cellular characterization (histotomography) allows brain nuclei to be computationally segmented and assigned to brain regions, and cell shapes and volumes to be computed for motor neurons and red blood cells. Striking individual phenotypic variation was apparent from color maps of computed densities of brain nuclei. Unlike histology, the histotomography also allows the study of 3-dimensional structures of millimeter scale that cross multiple tissue planes. We expect the computational and visual insights into 3D cell and tissue architecture provided by histotomography to be useful for reference atlases, hypothesis generation, comprehensive organismal screens, and diagnostics.

59 BASIC BIOLOGICAL SCIENCES↗

Chemical Profiling of the Plant Cell Wall through Raman Microspectroscopy

This paper presents a computational framework for chemical pro.ling of the plant cell wall through the Raman spectroscopy. The system enables query of known spectral signatures and clustering of spectral data based on intrinsic properties. As a result, presence and relative concentration of speci.c chemical bonds can be quanti.ed. The primary contribution of this paper is in representation of raman pro.le in terms of .uorescence background and multiscale peak detection at each grid point (voxel). Such a representation allows ef.cient spatial segmentation based on the coupling between high-level salient properties and low-level symbolic representation at each voxel. The high-level salient properties refer to preferred peaks and their attributes for the entire image. The low-level symbolic representations are based on .uorescence background, spectral peak locations, and their attributes. We present results on a corn stover tissue section that is imaged through Raman microscopy, and the results are consistent with the literature. In addition, automatic clustering indicates several distinct layers of the cell walls with different spectral signatures.

09 BIOMASS FUELS↗

Capacitively Coupled LAPPDs with 2D Pixelated Readout Planes for Time of Flight and Ring Imaging Cherenkov Applications

Large Area Picosecond Photon Detectors (LAPPDs) are micro-channel plate based photosensors featuring hundreds of square centimeters of sensitive area in a single package and capable of providing timing resolution on the order of 50 ps for single photon detection. However, LAPPDs currently do not exist in finely pixelated 2D readout configurations which, in addition to ighresolution timing, would also provide high spatial resolution required for Ring Imaging CHerenkov (RICH) detectors. One of the recent LAPPD models (Gen II) provides the opportunity to overcome the lack of pixellation by coupling an external readout to the sealed detector itself. The readout plane in this case is a simple printed circuit board (PCB) that can be laid out in a custom application-specific way for 1D or 2D sensitive area pixellation. This allows for a much shorter readout-plane prototyping cycle and provides unprecedented flexibility in choosing an appropriate segmentation that can be optimized for any particular detector need in terms of pad size, orientation, and shape.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DLSIA: Deep Learning for Scientific Image Analysis

DLSIA (Deep Learning for Scientific Image Analysis) is a Python-based machine learning library that empowers scientists and researchers across diverse scientific domains with a range of customizable convolutional neural network (CNN) architectures for a wide variety of tasks in image analysis to be used in downstream data processing. DLSIA features easy-to-use architectures, such as autoencoders, tunable U-Nets and parameter-lean mixed-scale dense networks (MSDNets). Additionally, this article introduces sparse mixed-scale networks (SMSNets), generated using random graphs, sparse connections and dilated convolutions connecting different length scales. For verification, several DLSIA-instantiated networks and training scripts are employed in multiple applications, including inpainting for X-ray scattering data using U-Nets and MSDNets, segmenting 3D fibers in X-ray tomographic reconstructions of concrete using an ensemble of SMSNets, and leveraging autoencoder latent spaces for data compression and clustering. As experimental data continue to grow in scale and complexity, DLSIA provides accessible CNN construction and abstracts CNN complexities, allowing scientists to tailor their machine learning approaches, accelerate discoveries, foster interdisciplinary collaboration and advance research in scientific image analysis.

97 MATHEMATICS AND COMPUTING↗

SU-F-R-46: Predicting Distant Failure in Lung SBRT Using Multi-Objective Radiomics Model

Purpose: To predict distant failure in lung stereotactic body radiation therapy (SBRT) in early stage non-small cell lung cancer (NSCLC) by using a new multi-objective radiomics model. Methods: Currently, most available radiomics models use the overall accuracy as the objective function. However, due to data imbalance, a single object may not reflect the performance of a predictive model. Therefore, we developed a multi-objective radiomics model which considers both sensitivity and specificity as the objective functions simultaneously. The new model is used to predict distant failure in lung SBRT using 52 patients treated at our institute. Quantitative imaging features of PET and CT as well as clinical parameters are utilized to build the predictive model. Image features include intensity features (9), textural features (12) and geometric features (8). Clinical parameters for each patient include demographic parameters (4), tumor characteristics (8), treatment faction schemes (4) and pretreatment medicines (6). The modelling procedure consists of two steps: extracting features from segmented tumors in PET and CT; and selecting features and training model parameters based on multi-objective. Support Vector Machine (SVM) is used as the predictive model, while a nondominated sorting-based multi-objective evolutionary computation algorithm II (NSGA-II) is used for solving the multi-objective optimization. Results: The accuracy for PET, clinical, CT, PET+clinical, PET+CT, CT+clinical, PET+CT+clinical are 71.15%, 84.62%, 84.62%, 85.54%, 82.69%, 84.62%, 86.54%, respectively. The sensitivities for the above seven combinations are 41.76%, 58.33%, 50.00%, 50.00%, 41.67%, 41.67%, 58.33%, while the specificities are 80.00%, 92.50%, 90.00%, 97.50%, 92.50%, 97.50%, 97.50%. Conclusion: A new multi-objective radiomics model for predicting distant failure in NSCLC treated with SBRT was developed. The experimental results show that the best performance can be obtained by combining all features.

60 APPLIED LIFE SCIENCES↗

A Comparative Study of Deep Learning Models for Fracture and Pore Space Segmentation in Synthetic Fractured Digital Rocks

This study focuses on the comparative study of deep learning (DL) models for pore space and discrete fracture networks (DFNs) segmentation in synthetic fractured digital rocks, specifically targeting low-permeability rock formations, such as shale and tight sandstones. Accurate characterization of pore space and DFNs is critical for subsequent property analysis and fluid flow modeling. Four DL models, SegNet, U-Net, U-Net-wide, and nested U-Net (i.e., U-Net++), were trained, validated, and tested using synthetic datasets, including input and label image pairs with varying properties. The model performance was assessed regarding pixel-wise metrics, including the F1 score and pixel-wise difference maps. In addition, the physics-based metrics were considered for further analysis, including sample porosity and absolute permeability. Particularly, We first simulated the permeability of porous media containing only pore space and then simulated the permeability of porous media with DFNs added. The difference between these two values is used to quantify the connectivity of segmented DFNs, which is an important parameter for low-permeability rocks. The pixel-wise metrics showed that the nested U-Net model outperformed the rest of the DL models in pore space and DFNs segmentation, with the SegNet model exhibiting the second-best performance. Particularly, nested U-Net enhanced segmentation accuracy for challenging boundary pixels affected by partial volume effects. The U-Net-wide model achieved improved accuracy compared to the U-Net model, which indicated the influence of parameter numbers. Similarly, nested U-Net has the closest match to the ground truth of physics-based metrics, including the porosity of pore space and DFNs, and the permeability difference quantifying the connectivity of DFNs. The findings highlight the effectiveness of DL models, especially the U-Net++ model with nested architecture and redesigned skip connections, in accurately segmenting pore spaces and DFNs, which are crucial for pore-scale fluid flow and transport simulation in low-permeability rocks.

Wang, Hongsheng↗

Focal Stenting of Complex Femoropopliteal Lesions with the Multi-LOC Multiple Stent Delivery System: 12-Month Results of the Multicenter LOCOMOTIVE Study

Introduction: The purpose of this observational study is to report the 12-month clinical outcomes with the novel Multiple Stent Delivery System (MSDS) to treat complex femoropopliteal lesions. Previously, we reported the 6-month clinical outcomes of the all-comers LOCOMOTIVE study, which demonstrated the safety and efficacy of the MSDS with a favorable target lesion revascularization (TLR) rate of 5.3% and a 90.7% patency rate at 6 months in claudicants and critical limb ischemia patients. The 12-month outcomes of LOCOMOTIVE registry are presented in this report. ClinicalTrials.gov Identifier: NCT02531230. Methods: The LOCOMOTIVE study (Multi-LOC for flOw liMiting Outcomes after POBA and/or DCB Treatment in the infrainguinal position with the objecIVE to implant multiple stent segments) investigates the efficacy and safety of the MSDS approach in an all-comers population. Clinical follow-ups at 6 and 12 months are scheduled to assess TLR, ABI, and vessel patency based on sonographic imaging. Results: At 12 months, the primary unassisted patency was 85.7% and all-cause TLR rate was 9.3% in the overall cohort. Between baseline and 12 months, the target leg ABI increased from 0.62 ± 0.24 to 0.91 ± 0.38 (p < 0.001) and the mean Rutherford class improved from 3.5 to 1.9 (p < 0.001). Conclusions: Over a 12-month post-procedural period, MSDS for focal provisional stenting of complex femoropopliteal lesions demonstrated a promising primary patency and freedom from TLR after 12 months. In addition, significant improvements were observed in symptom classification and hemodynamics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of a Model-Based Segmentation Approach to Propagating Normal Anatomic Regions of Interest Through the 10 Phases of Respiration

Purpose: To validate a model-based segmentation (MBS) algorithm in a commercial radiation treatment planning system for use in propagating the contours of normal anatomic regions of interest (ROIs) through the respiratory phases that constitute a four-dimensional (4D) computed tomography (CT) image data set. Methods and Materials: The 4D CT data sets for 12 patients treated for non-small-cell lung cancer were acquired. Five ROIs were selected for delineation: right and left lungs, spinal cord, heart, and esophagus. These ROIs were manually delineated on the CT data set corresponding to the end-inspiration respiratory phase (0%). An MBS algorithm implemented on the treatment planning system propagated the ROIs sequentially through the respiratory phases that constituted the 4D CT data sets, concluding with the 0% phase data set, which was propagated from the 90% phase data set. The propagated ROIs on the 0% phase were compared with the original ROIs on that phase by using visual assessment and a quantitative measure of coincidence. Results: Acceptable propagation accuracy within 1 mm of uncertainty was achieved for lungs and spinal cord. Propagation of the heart produced slightly larger contours that were similar to interphysician variations in contouring the heart. The esophagus was poorly propagated because of lack of tissue contrast and definitive shape. Conclusions: The MBS propagation is a promising tool for efficiently propagating contours through the different phases of respiration. However, propagating the esophagus through this technique may be difficult because of the lack of definitive shape and clearer boundaries from surrounding tissue.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A new protocol to accurately determine microtubule lattice seam location

Microtubules (MTs) are cylindrical polymers of αβ-tubulin that display pseudo-helical symmetry due to the presence of a lattice seam of heterologous lateral contacts. The structural similarity between α- and β-tubulin makes it difficult to computationally distinguish them in the noisy cryo-EM images, unless a marker protein for the tubulin dimer, such as kinesin motor domain, is present. We have developed a new data processing protocol that can accurately determine αβ-tubulin register and seam location for MT segments. Our strategy can handle difficult situations, where the marker protein is relatively small or the decoration of marker protein is sparse. Using this new seam-search protocol, combined with movie processing for data from a direct electron detection camera, we were able to determine the cryo-EM structures of MT at 3.5. Å resolution in different functional states. The successful distinction of α- and β-tubulin allowed us to visualize the nucleotide state at the E-site and the configuration of lateral contacts at the seam.

59 BASIC BIOLOGICAL SCIENCES↗

A Collaboration Website for Muon Catalyzed Fusion and Muon Beam Production

This research initiative establishes a dynamic online platform geared towards supporting the burgeoning Muon Catalyzed Fusion collaboration, focusing on the concurrent development of particle accelerators and transport beamlines for muon beams. The central feature of this endeavor is the creation of a multifaceted website comprising both public facing and private sections to cater to diverse user needs. The public segment is meticulously designed to serve as an educational hub, featuring information pages targeted at the general public alongside private pages exclusively accessible to collaboration members. These pages will host an array of multimedia elements, ranging from images and text animations to video lectures, covering an extensive spectrum of topics integral to the science of Muon Catalyzed Fusion. Encompassing areas such as Acceleration, Applications, Instrumentation, Beamline Design, and beam dynamics design codes, the educational content aims to make complex scientific concepts more accessible to a broader audience. Ensuring seamless accessibility across various devices and operating systems, the website incorporates integration with collaborative tools such as Google Docs for document collaboration, GitHub for code repository management, and WordPress for blogging with interactive commenting features. The bifurcation between public and private sections is a strategic approach to maintaining transparency while safeguarding proprietary research and works in progress. The public pages are strategically crafted to disseminate information, showcasing the latest endeavors and achievements within the NK Labs collaboration, including lectures, published papers, and regular blog posts open to public comments. On the other hand, the private section provides collaboration members with a secure space to share unpublished or nonpublic research, fostering collaborative efforts through integrated Google Docs and Python Plotty for shared graphing work. In essence, this ambitious project endeavors to bridge the gap between complex scientific knowledge and public understanding, enhance collaboration among researchers, and serve as a dynamic and inclusive platform for sharing and advancing the state-of-the-art in Muon Catalyzed Fusion and Accelerators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Micro-CT Imaging and Fluid Flow Simulations of Fractures in MSEEL Shale

micro-CT scans of a naturally fractured MSEEL shale sample as a shear fracture is generated and displaced in the center, intact region of the sample. Steady State laminar fluid flow simulations were then performed on each individual fracture during each experimental segment as effective stress and shear displacement changed. Released under LA-UR-21-24335.

Fractures,Fracturing Initiation,Marcellus Shale↗

End-to-end deep learning pipeline for real-time Bragg peak segmentation: from training to large-scale deployment

X-ray crystallography reconstruction, which transforms discrete X-ray diffraction patterns into three-dimensional molecular structures, relies critically on accurate Bragg peak finding for structure determination. As X-ray free electron laser (XFEL) facilities advance toward MHz data rates (1 million images per second), traditional peak finding algorithms that require manual parameter tuning or exhaustive grid searches across multiple experiments become increasingly impractical. While deep learning approaches offer promising solutions, their deployment in high-throughput environments presents significant challenges in automated dataset labeling, model scalability, edge deployment efficiency, and distributed inference capabilities. We present an end-to-end deep learning pipeline with three key components: (1) a data engine that combines traditional algorithms with our peak matching algorithm to generate high-quality training data at scale, (2) a modular architecture that scales from a few million to hundreds of million parameters, enabling us to train large expert-level models offline while deploying smaller, distilled models at the edge, and (3) a decoupled producer-consumer architecture that separates specialized data source layer from model inference, enabling flexible deployment across diverse computing environments. Using this integrated approach, our pipeline achieves accuracy comparable to traditional methods tuned by human experts while eliminating the need for experiment-specific parameter tuning. Although current throughput requires optimization for MHz facilities, our system's scalable architecture and demonstrated model compression capabilities provide a foundation for future high-throughput XFEL deployments.

Wang, Cong↗

Rubidium-82 PET imaging is feasible in a rat myocardial infarction model

Background: Small-animal myocardial infarct models are frequently used in the assessment of new cardioprotective strategies. A validated quantification of perfusion using a non-cyclotron-dependent PET tracer would be of importance in monitoring response to therapy. We tested whether myocardial PET perfusion imaging is feasible with Rubidium-82 ({sup 82}Rb) in a small-animal scanner using a rat myocardial infarct model. Methods: 18 Sprague-Dawley rats underwent permanent coronary artery ligation (infarct group), and 11 rats underwent ischemia-reperfusion (reperfusion group) procedure. {sup 82}Rb-PET and magnetic resonance imaging (MRI) were conducted before and after the intervention. Perfusion was compared to both left ventricle ejection fraction (LVEF) and infarct size assessed by MRI. Results: Follow-up global {sup 82}Rb-uptake correlated significantly with infarct size (infarct group: r = −0.81, P < 0.001 and reperfusion group: r = −0.61, P = 0.04). Only {sup 82}Rb-uptake in the infarct group correlated with LVEF. At follow-up, a higher segmental {sup 82}Rb-uptake in the infarct group was associated with better wall motion (β = 0.034, CI [0.028;0.039], P < 0.001, R{sup 2} = 0.30), and inversely associated with scar transmurality (β = −2.4 [−2.6; −2.2], P < 0.001, R{sup 2} = 0.59). The associations were similar for the reperfusion group. Conclusion: {sup 82}Rb-PET is feasible in small animal scanners despite the long positron range and enables fast and time-efficient myocardial perfusion imaging in rat models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-84: Comparison of Quantitative Deformable Image Registration Evaluation Tools: Application to Prostate IGART

Purpose: Errors in displacement vector fields (DVFs) generated by Deformable Image Registration (DIR) algorithms can give rise to significant uncertainties in contour propagation and dose accumulation in Image-Guided Adaptive Radiotherapy (IGART). The purpose of this work is to assess the accuracy of two DIR algorithms using a variety of quality metrics for prostate IGART. Methods: Pelvic CT images were selected from an anonymized database of nineteen prostate patients who underwent 8–12 serial scans during radiotherapy. Prostate, bladder, and rectum were contoured on 34 image-sets for three patients by the same physician. The planning CT was deformably-registered to daily CT using three variants of the Small deformation Inverse Consistent Linear Elastic (SICLE) algorithm: Grayscale-driven (G), Contour-driven (C, which utilizes segmented structures to drive DIR), combined (G+C); and also grayscale ITK demons (Gd). The accuracy of G, C, G+C SICLE and Gd registrations were evaluated using a new metric Edge Gradient Distance to Agreement (EGDTA) and other commonly-used metrics such as Pearson Correlation Coefficient (PCC), Dice Similarity Index (DSI) and Hausdorff Distance (HD). Results: C and G+C demonstrated much better performance at organ boundaries, revealing the lowest HD and highest DSI, in prostate, bladder and rectum. G+C demonstrated the lowest mean EGDTA (1.14 mm), which corresponds to highest registration quality, compared to G and C DVFs (1.16 and 2.34 mm). However, demons DIR showed the best overall performance, revealing lowest EGDTA (0.73 mm) and highest PCC (0.85). Conclusion: As expected, both C- and C+G SICLE more accurately reproduce manually-contoured target datasets than G-SICLE or Gd using HD and DSI metrics. In general, the Gd appears to have difficulty reproducing large daily position and shape changes in the rectum and bladder. However, Gd outperforms SICLE in terms of EGDTA and PCC metrics, possibly at the expense of topological quality of the estimated DVFs.

60 APPLIED LIFE SCIENCES↗

SU-E-J-272: Auto-Segmentation of Regions with Differentiating CT Numbers for Treatment Response Assessment

Purpose: It has been reported recently that the change of CT number (CTN) during and after radiation therapy (RT) may be used to assess RT response. The purpose of this work is to develop a tool to automatically segment the regions with differentiating CTN and/or with change of CTN in a series of CTs. Methods: A software tool was developed to identify regions with differentiating CTN using K-mean Cluster of CT numbers and to automatically delineate these regions using convex hull enclosing method. Pre- and Post-RT CT, PET, or MRI images acquired for sample lung and pancreatic cancer cases were used to test the software tool. K-mean cluster of CT numbers within the gross tumor volumes (GTVs) delineated based on PET SUV (standard uptake value of fludeoxyglucose) and/or MRI ADC (apparent diffusion coefficient) map was analyzed. The cluster centers with higher value were considered as active tumor volumes (ATV). The convex hull contours enclosing preset clusters were used to delineate these ATVs with color washed displays. The CTN defined ATVs were compared with the SUV- or ADC-defined ATVs. Results: CTN stability of the CT scanner used to acquire the CTs in this work is less than 1.5 Hounsfield Unit (HU) variation annually. K-mean cluster centers in the GTV have difference of ∼20 HU, much larger than variation due to CTN stability, for the lung cancer cases studied. The dice coefficient between the ATVs delineated based on convex hull enclosure of high CTN centers and the PET defined GTVs based on SUV cutoff value of 2.5 was 90(±5)%. Conclusion: A software tool was developed using K-mean cluster and convex hull contour to automatically segment high CTN regions which may not be identifiable using a simple threshold method. These CTN regions were reasonably overlapped with the PET or MRI defined GTVs.

60 APPLIED LIFE SCIENCES↗

Enhanced x-ray imaging for a thin film cochlear implant with metal artefacts using phase retrieval tomography

Phase retrieval tomography has been successfully used to enhance imaging in systems that exhibit poor absorption contrast. However, when highly absorbing regions are present in a sample, so-called metal artefacts can appear in the tomographic reconstruction. We demonstrate that straightforward approaches for metal artefact reconstruction, developed in absorption contrast tomography, can be applied when using phase retrieval. Using a prototype thin film cochlear implant that has high and low absorption components made from iridium (or platinum) and plastic, respectively, we show that segmentation of the various components is possible and hence measurement of the electrode geometry and relative location to other regions of interest can be achieved.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accurate Automatic Delineation of Heterogeneous Functional Volumes in Positron Emission Tomography for Oncology Applications

Purpose: Accurate contouring of positron emission tomography (PET) functional volumes is now considered crucial in image-guided radiotherapy and other oncology applications because the use of functional imaging allows for biological target definition. In addition, the definition of variable uptake regions within the tumor itself may facilitate dose painting for dosimetry optimization. Methods and Materials: Current state-of-the-art algorithms for functional volume segmentation use adaptive thresholding. We developed an approach called fuzzy locally adaptive Bayesian (FLAB), validated on homogeneous objects, and then improved it by allowing the use of up to three tumor classes for the delineation of inhomogeneous tumors (3-FLAB). Simulated and real tumors with histology data containing homogeneous and heterogeneous activity distributions were used to assess the algorithm's accuracy. Results: The new 3-FLAB algorithm is able to extract the overall tumor from the background tissues and delineate variable uptake regions within the tumors, with higher accuracy and robustness compared with adaptive threshold (T{sub bckg}) and fuzzy C-means (FCM). 3-FLAB performed with a mean classification error of less than 9% +- 8% on the simulated tumors, whereas binary-only implementation led to errors of 15% +- 11%. T{sub bckg} and FCM led to mean errors of 20% +- 12% and 17% +- 14%, respectively. 3-FLAB also led to more robust estimation of the maximum diameters of tumors with histology measurements, with <6% standard deviation, whereas binary FLAB, T{sub bckg} and FCM lead to 10%, 12%, and 13%, respectively. Conclusion: These encouraging results warrant further investigation in future studies that will investigate the impact of 3-FLAB in radiotherapy treatment planning, diagnosis, and therapy response evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗