Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

MULTI-SCALE MODELING AND APPROXIMATION ASSISTED OPTIMIZATION OF BARE TUBE HEAT EXCHANGERS

Air-to-refrigerant heat exchangers are very common in air-conditioning, heat pump and refrigeration applications. In these heat exchangers, there is a great benefit in terms of size, weight, refrigerant charge and heat transfer coefficient, by moving from conventional channel sizes (~ 9mm) to smaller channel sizes (< 5mm). This work investigates new designs for air-to-refrigerant heat exchangers with tube outer diameter ranging from 0.5 to 2.0mm. The goal of this research is to develop and optimize the design of these heat exchangers and compare their performance with existing state of the art designs. The air-side performance of various tube bundle configurations are analyzed using a Parallel Parameterized CFD (PPCFD) technique. PPCFD allows for fast-parametric CFD analyses of various geometries with topology change. Approximation techniques drastically reduce the number of CFD evaluations required during optimization. Maximum Entropy Design method is used for sampling and Kriging method is used for metamodeling. Metamodels are developed for the air-side heat transfer coefficients and pressure drop as a function of tube-bundle dimensions and air velocity. The metamodels are then integrated with an air-to-refrigerant heat exchanger design code. This integration allows a multi-scale analysis of air-side performance heat exchangers including air-to-refrigerant heat transfer and phase change. Overall optimization is carried out using a multi-objective genetic algorithm. The optimal designs found can exhibit 50 percent size reduction, 75 percent decrease in air side pressure drop and doubled air heat transfer coefficients compared to a high performance compact micro channel heat exchanger with same capacity and flow rates.

CFD↗

Analysis on the Preliminary Gap Conductance Test with Single Primary Heat Extraction and Removal Emulator

Microreactor is a type of nuclear reactor that is intended to produce thermal energy from the micro and integrated design. Among various microreactor roadmaps, microreactor with heat pipes is one of the promising designs that under active development. At Idaho National Laboratory (INL) and supported by the Department of Energy (DOE) Microreactor Program (MRP), a Single Primary Heat Extraction and Removal Emulator (SPHERE) was developed. The main purpose of SPHRE is to understand thermal performance of heat pipe in the conjunction of heat source without using nuclear material. The heat pipe used in the SPHERE has sodium as a working fluid, with Argon gas in the vapor region, thus this heat pipe is variable conductance heat pipe (VCHP). The volume of non-condensable gas changes with power and elapsed time, so the area covered by non-condensable gas changes. This gives an effect that passively controls the cooling capability of condenser section. This preliminary experiment was intended to perform a gap conductance experiment that reveals heat transfer characteristics of gas at the gap around the heat pipe. However, there are not many experimental data that deals with heat transfer of the gas at the gap around heat pipe. In this research, the preliminary experimental result regarding to the heat pipe performance with different composition of gas at the gap, level of power is presented. The experimental data will be used for the validation study of SOCKEYE as a future plan.

42 ENGINEERING↗

Development and experimental qualification of a calculation scheme for the evaluation of gamma heating in experimental reactors. Application to MARIA and Jules Horowitz (JHR) MTR Reactors

Precise computational determination of nuclear heating which consists predominantly of gamma heating (more than 80 %) is one of the challenges in material testing reactor exploitation. Due to sophisticated construction and conditions of experimental programs planned in JHR it became essential to use most accurate and precise gamma heating model. Before the JHR starts to operate, gamma heating evaluation methods need to be developed and qualified in other experimental reactor facilities. This is done inter alia using OSIRIS, MINERVE or EOLE research reactors in France. Furthermore, MARIA - Polish material testing reactor - has been chosen to contribute to the qualification of gamma heating calculation schemes/tools. This reactor has some characteristics close to those of JHR (beryllium usage, fuel element geometry). To evaluate gamma heating in JHR and MARIA reactors, both simulation tools and experimental program have been developed and performed. For gamma heating simulation, new calculation scheme and gamma heating model of MARIA have been carried out using TRIPOLI4 and APOLLO2 codes. Calculation outcome has been verified by comparison to experimental measurements in MARIA reactor. To have more precise calculation results, model of MARIA in TRIPOLI4 has been made using the whole geometry of the core. This has been done for the first time in the history of MARIA reactor and was complex due to cut cone shape of all its elements. Material composition of burnt fuel elements has been implemented from APOLLO2 calculations. An experiment for nuclear heating measurements and calculation verification has been done in September 2014. This involved neutron, photon and nuclear heating measurements at selected locations in MARIA reactor using in particular Rh SPND, Ag SPND, Ionization Chamber (all three from CEA), KAROLINA calorimeter (NCBJ) and Gamma Thermometer (CEA/SCK CEN). Measurements were done in forty points using four channels. Maximal nuclear heating evaluated from measurements is of the order of 2.5 W/g at half of the possible MARIA power - 15 MW. The approach and the detailed program for experimental verification of calculations will be presented. The following points will be discussed: - Development of a gamma heating model of MARIA reactor with TRIPOLI 4 (coupled neutron-photon mode) and APOLLO2 model taking into account the key parameters like: configuration of the core, experimental loading, control rod location, reactor power, fuel depletion); - Design of specific measurement tools for MARIA experiments including for instance a new single-cell calorimeter called KAROLINA calorimeter; - MARIA experimental program description and a preliminary analysis of results; - Comparison of calculations for JHR and MARIA cores with experimental verification analysis, calculation behavior and n-γ 'environments'. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Defining an industrial heat pump: A review & synthesis

Clear and understandable definitions of advanced energy technologies are not common and often confuse those who are not experts. This review paper addresses a critical issue in the field of heat pumps: the ambiguity surrounding the term “industrial heat pump.” The term, as discussed in various literature and media, often leads to misconceptions about the capabilities and applications of heat pumps, particularly in industrial contexts. This review paper seeks to refine and unify the definition of industrial heat pumps by analyzing existing academic and commercial literature, industry reports, and classifications. Unique identifiers explored for the definition of an industrial heat pump include the use of waste heat, operating temperature ranges, size specifications, and specific end-use applications. The study reveals differences in how industrial heat pumps are defined in academic and commercial contexts, highlighting the need for a standardized definition to facilitate better communication among manufacturers, policymakers, and end users. This is especially important considering recent legislative efforts such as the HEAT Act, which seeks to promote industrial heat pump adoption. The proposed definition aims to provide clarity while supporting the effective deployment of industrial heat pumps. With proper adoption, the definition will help promote the role of industrial heat pumps in achieving energy efficiency goals in the industrial sector. The intended impact is for the definition to serve as a foundational reference for future research and policy development.

Heat pump characteristics↗

Particle-wall heat transfer in narrow-channel bubbling fluidized beds for thermal energy storage

Robust metal oxide particles can provide low-cost and stable thermal energy storage (TES) to temperatures up to 1200 °C or higher. The transfer of heat into and out of the particles in cost-effective high-temperature particle heat exchangers remains a principal challenge to implementing particle-based TES. The present work expands on prior studies of particle-wall heat transfer in narrow-channel fluidized beds operated in the bubbling fluidization regime. Batch-mode experiments with various oxide particles over a range of temperatures and airflow rates indicate that particle-wall heat transfer increases with higher bed temperature and decreasing particle size. Measured particle-wall heat transfer coefficients in a 12 mm deep channel are fit to a Nusselt number correlation proportional to a non-monotonic function of excess fluidization velocity. Particle-wall heat transfer coefficients rise rapidly with excess fluidization velocities until reaching a maximum at intermediate air velocities due to a trade-off between enhanced transverse particle mixing and decreasing particle volume fraction with increased fluidization velocity. The heat transfer coefficient reaches a maximum of ≈ 400% of values without fluidization for oxide particles ranging in diameter d p from 159 to 408 μm. For the smallest particles tested, composed of olivine sand, particle-wall heat transfer coefficients peak above 1100 Wm –2 K –1 at 450 °C. 100-h tests at 500 °C and near-optimal heat transfer fluidization velocities indicated minimal wall wear or oxide scaling. Furthermore, high particle-wall heat transfer coefficients suggest narrow channel fluidized beds as a potential pathway for reducing the required surface area and cost of high-temperature particle heat exchangers, as needed in large-scale thermal energy storage applications.

14 SOLAR ENERGY↗

Estimation of and barriers to waste heat recovery from harsh environments in industrial processes

This paper discusses the industrial potential for waste heat recovery (WHR) in harsh environments – defined as a waste heat stream having either a temperature of at least 650 °C or containing reactive constituents that complicate heat recovery. The analysis covers five industries (steel, aluminum, glass, cement, and lime), chosen based on volume of production, discharge of exhaust gases containing components that present harsh environments, possibility of recovering considerably more heat than currently recovered, and current lack of acceptable WHR options. The total potential energy savings identified in harsh environment waste heat streams from these industries is equal to 15.4% (113.6 TWh) of the process heat energy lost in U.S. manufacturing. Existing technologies and materials for these industries are evaluated and the recoverable waste heat from harsh environment gas for each industrial sector is estimated. Finally, an in-depth summary of each waste heat source shows exactly where waste heat can be recovered and what specific issues must be addressed. The most potential lies within steel blast furnaces (46 TWh/year). Other waste heat streams considered include steel electric arc furnaces (14.1 TWh/year), flat glass (3.6 TWh/year), container glass (5.7 TWh/year), glass fiber (1.1 TWh/year), specialty glass (2.2 TWh/year), aluminum melting furnaces (4.7 TWh/year), cement (17.1 TWh/year), and lime (10.5 TWh/year). Furthermore attempts to recover waste heat in harsh environments have been mostly unsuccessful, advances in research and technology could unlock an enormous potential for energy and cost savings.

42 ENGINEERING↗

NGNP/HTE full-power operation at reduced high-temperature heat exchanger temperatures.

Operation of the Next Generation Nuclear Plant (NGNP) with reduced reactor outlet temperature at full power was investigated for the High Temperature Electrolysis (HTE) hydrogen-production application. The foremost challenge for operation at design temperature is achieving an acceptably long service life for heat exchangers. In both the Intermediate Heat Exchanger (IHX) and the Process Heat Exchanger (PHX) (referred to collectively as high temperature heat exchangers) a pressure differential of several MPa exists with temperatures at or above 850 C. Thermal creep of the heat exchanger channel wall may severely limit heat exchanger life depending on the alloy selected. This report investigates plant performance with IHX temperatures reduced by lowering reactor outlet temperature. The objective is to lower the temperature in heat transfer channels to the point where existing materials can meet the 40 year lifetime needed for this component. A conservative estimate for this temperature is believed to be about 700 C. The reactor outlet temperature was reduced from 850 C to 700 C while maintaining reactor power at 600 MWt and high pressure compressor outlet at 7 MPa. We included a previously reported design option for reducing temperature at the PHX. Heat exchanger lengths were adjusted to reflect the change in performance resulting from coolant property changes and from resizing related to operating-point change. Turbomachine parameters were also optimized for the new operating condition. An integrated optimization of the complete system including heat transfer equipment was not performed. It is estimated, however, that by performing a pinch analysis the combined plant efficiency can be increased from 35.5 percent obtained in this report to a value between 38.5 and 40.1 percent. Then after normalizing for a more than three percent decrease in commodities inventory compared to the reference plant, the commodities-normalized efficiency lies between 40.0 and 41.3. This compares with a value of 43.9 for the reference plant. This latter plant has a reactor outlet temperature of 850 C and the two high temperature heat exchangers. The reduction in reactor outlet temperature from 850 C to 700 C reduces the tritium permeability rate in the IHX metal by a factor of three and thermal creep by five orders of magnitude. The design option for reducing PHX temperature from 800 C to 200 C reduces the permeability there by three orders of magnitude. In that design option this heat exchanger is the single 'choke-point' for tritium migration from the nuclear to the chemical plant.

08 HYDROGEN↗

A Method for Calculating the Heat Required for Windshield Thermal Ice Prevention Based on Extensive Flight Tests in Natural Icing Conditions

An equation is presented for calculating the heat flow required from the surface of an internally heated windshield in order to prevent the formation of ice accretions during flight in specified icing conditions. To ascertain the validity of the equation, comparison is made between calculated values of the heat required and measured values obtained for test windshields in actual flights in icing conditions. The test windshields were internally heated and provided data applicable to two common types of windshield configurations; namely the V-type and the type installed flush with the fuselage contours. These windshields were installed on a twin-engine cargo airplane and the icing flights were conducted over a large area of the United States during the winters of 1945-46 and 1946-47. In addition to the internally heated windshield investigation, some test data were obtained for a windshield ice-prevention system in which heated air was discharged into the windshield boundary layer. The general conclusions resulting from this investigation are as follows: 1) The amount of heat required for the prevention of ice accretions on both flush- and V-type windshields during flight in specified icing conditions can be calculated with a degree of accuracy suitable for design purposes. 2) A heat flow of 2000 to 2500 Btu per hour per square foot is required for complete and continuous protection of a V-type windshield in fight at speeds up to 300 miles per hour in a moderate cumulus icing condition. For the same degree of protection and the same speed range, a value of 1000 Btu per hour per square foot suffices in a moderate stratus icing condition. 3) A heat supply of 1000 Btu per hour per square foot is adequate for a flush windshield located well aft of the fuselage stagnation region, at speeds up to 300 miles per hour, for flight in both stratus and moderate cumulus icing conditions. 4) The external air discharge system of windshield thermal ice prevention is thermally inefficient and requires a heat supply approximately 20 times that required for an internal system having the same performance.

ICE FORMATION↗

Time-Dependent 600 °C Post-Weld Heat Treatment Response of Laser-Wire-Directed Energy Deposited Austenitic Stainless Steel Claddings on Carbon Steel

Austenitic stainless steel overlay claddings are often used to protect nuclear reactor pressure vessels from corrosion. Arc welding processes are traditionally employed, which require a high heat input to bond the dissimilar metals, creating a large heat-affected zone and high residual stress that demands a lengthy stress-relieving post-weld heat treatment, up to 48 hours. High energy beam (e.g., laser, electron beam) directed energy deposition-based overlay cladding processes show promise for fabricating claddings with superior performance compared to arc welded ones because of their localized heat input; however, their necessity and time of post-weld heat treatment are currently unclear. In this research, we investigate the time dependence of a 600 C stress-relieving post-weld heat treatment of austenitic stainless steel clad on low carbon steel by laser-wire-directed energy deposition, comparing the microstructure and mechanical properties of the as-fabricated condition to 2-, 10-, and 48-hour heat treatment times. Diffusion simulations and microscopy show a gradual carburization of the stainless steel cladding and decarburization of the heat-affected zone/base metal. Nanoindentation testing shows up to a 1.8–2.69 embrittlement in the cladding and a 0.33 to 0.69 softening in the heat-affected zone after the 48-hour post-weld heat treatment. Tensile testing of the cladding composites reveals that increasing post-weld heat treatment time raises clad cracking susceptibility due to intergranular carbide formation and shows that laser-wire-directed energy deposition claddings may not require post-weld heat treatment.

Coating↗

Effects of bentonite heating on U(VI) adsorption

Engineered barrier systems designed to isolate high-level radioactive waste utilize bentonite, a montmorillonite rich material, to restrict contaminant transport due to its low hydraulic conductivity and high adsorption capacity. High temperatures (100–200 °C) near waste canisters resulting from radioactive decay may alter the clay's ability to adsorb contaminants. In this study, we examine U(VI) adsorption onto two different bentonite samples subjected to (1) 18 years of in situ heating during an underground experiment and (2) short-term (7-week), high temperature (300 °C) heating in the laboratory. Results show that U(VI) adsorption was lower for field-heated bentonite located closest to the heater, which experienced temperatures of approximately 95 °C, compared to a control sample, which experienced temperatures of approximately 20 °C, over a range of aqueous chemical conditions. On average, K d values for U(VI) adsorption were 31% lower for 95 °C heated samples. By contrast, U(VI) adsorption onto intermediate-heated bentonite (50 °C) was indistinguishable from the adsorption onto the cold-zone (20 °C) sample. U(VI) adsorption onto lab-heated bentonite was also lower than onto control bentonite over the pH range 4.5–8.0, with an average decrease in K d values of 50% after heating. Lower U(VI) adsorption to field-heated bentonite persisted after bentonite was purified to isolate the clay fraction. This allows us to rule out changes in pore-water chemistry or accessory mineral composition as causes of the lower adsorption. No evidence of montmorillonite illitization was observed in the heated samples. While some of the lower U(VI) adsorption in the lab-heated bentonite can be explained by changes in aqueous U(VI) speciation, we propose that lower U(VI) adsorption to field-heated bentonite may be primarily due to changes in the montmorillonite edge structure. The observed changes in U(VI) adsorption to bentonite after heating have implications for U(VI) diffusive transport through engineered barriers and must be considered when designing radioactive waste disposal repositories.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Study of optimal sizing for residential sorption heat pump system

Gas-driven sorption heat pumps (GDSHP) show significant potential to reduce primary energy use, associated emissions and energy costs for space heating and domestic hot water production in residential applications. This study considered a bivalent heating system consisting of a sorption heat pump and a condensing boiler, and focuses on the optimal heating capacity of each of these components relative to each other. Two bivalent systems were considered: one based on a solid chemisorption cycle (GDSHPA), and one based on a resorption cycle (GDSHPB). Simulations of year-round space heating loads for two single-family houses, one in New York and the other Minnesota, were carried out and the seasonal gas coefficient of performance (SGCOP) calculated. The sorption heat pump’s design heating capacity as a fraction of the bivalent system’s total heating capacity was varied from 0 to 100%. Results show that SGCOP was effectively constant for sorption heat pump design capacity greater than 41% of the peak bivalent GDSHPA design capacity in Minnesota, and 32% for GDSHPB. In New York, these values were 42% and 34% for GDSHPA and GDSHPB respectively. The payback period was also evaluated based on postulated sorption heat pump component costs. The fastest payback was achieved with sorption heat pump design capacity between 22 and 44%.

42 ENGINEERING↗

Experimental study of a tri-functional propane hydronic heat pump

This study investigates the performance of a propane hydronic heat pump system for space cooling, heating, and water heating applications, focusing on various operational conditions, with a total refrigerant charge below 1200 g. Cooling performance was evaluated at different outdoor temperatures, compressor stages (capacity levels), and water flow rates. The results showed that the coefficient of performance (COP) for cooling was higher at lower outdoor temperatures, with peak values exceeding 5.0 under low-stage operation and lower water flow rate. The cooling capacity increased with higher flow rates and compressor stages, reaching 12 kW. Space heating performance, evaluated at ambient temperatures ranging from −8.3 °C to 16.7 °C, revealed a decrease in COP with lower temperatures. However, high-stage operation maintained higher heating capacities even at low temperatures. The system demonstrated high Heating Seasonal Performance Factors (HSPF), exceeding 10.0. For water heating, the COP decreased with lower ambient temperatures and higher supply water temperatures. The system efficiently heated an 189-L water tank, outperforming conventional water heaters, with process COPs exceeding 4.0 under cooling-season conditions. Despite some efficiency loss due to defrosting at low temperatures, the propane heat pump consistently delivered strong performance. Seasonal energy efficiency ratios (SEER) and seasonal heating COP values indicated significant overall efficiency. The study concludes that propane is a promising refrigerant for heat pump systems, with future research needed to future reduce total system charge and optimize system performance through advanced controls and heat exchanger designs.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Inferring the scrape-off layer heat flux width in a divertor with a low degree of axisymmetry

Plasma facing components (PFCs) in the next generation of tokamak devices will operate in challenging environments, with heat loads predicted to exceed 10 MWm -2 . The magnitude of these heat loads is set by the width of the channel, the ‘scrape-off layer’ (SOL), into which heat is exhausted, and can be characterised by an e-folding length scale for the decay of heat flux across the channel. It is expected this channel will narrow as tokamaks move towards reactor relevant conditions. Understanding the processes involved in setting the SOL heat flux width is imperative to be able to predict the heat loads PFCs must handle in future devices. Measurements of the SOL width are performed on the high-field spherical tokamak, ST40, using a newly commissioned infrared thermography system. With its high on-axis toroidal magnetic field (≥1.5 T) ST40 is uniquely positioned to investigate the influence of toroidal field on the heat flux width in spherical tokamaks, whilst also extending measurements of the SOL width in spherical tokamaks to increased poloidal field (≥0.3 T). Due to the divertor on ST40 having a low degree of axisymmetry, it is necessary for a set of radial measurements of the heat flux to be taken across the divertor, made possible using an automated toolchain that fully incorporates its 3D geometry. These radial profiles are combined with the magnetic geometry of the plasma to infer the width of the SOL, with both Eich and double exponential profiles of heat flux observed. A reduction in the heat flux is observed toroidally across part of the divertor, along with increased heat loads observed locally around the edges of the tiles. Future work in characterising the impact of tile misalignment and uncertainties in the reconstructed divertor magnetic geometry is required in order to further understand the observed heat flux patterns, as are additional investigations into the role potentially being played by an inhomogeneous sheath electric field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The importance of sub-meter-scale snow roughness on conductive heat flux of Arctic sea ice

Abstract The conductive heat flux through the snow and ice is a critical component of the mass and energy budgets in the Arctic sea ice system. We use high horizontal resolution (3–15 cm) measurements of snow topography to explore the impacts of sub-meter-scale snow surface roughness on heat flux as simulated by the Finite Element method. Simulating horizontal heat flux in a variable snow cover modestly increases the total simulated heat flux. With horizontal heat flux, as opposed to simple 1D-vertical heat flux modeling, the simulated heat flux is 10% greater than that for uniform snow with the same mean snow thickness for a 31.5 × 21 m region of sea ice (the largest region we studied). Vertical-only (1D) heat flux simulates just a 6% increase for the same region. However, this is highly dependent on observation resolution. Had we measured the snow cover at 1 m horizontal spacing or greater, simulating horizontal heat flux would not have changed the net heat flux from that simulated with vertical-only heat flux. These findings suggest that measuring and modeling snow roughness at sub-meter horizontal scales may be necessary to accurately represent horizontal heat flux on level Arctic sea ice.

Geology↗

Energy dataset of Frontier supercomputer for waste heat recovery

The Hewlett Packard Enterprise–Cray EX Frontier is the world’s first and fastest exascale supercomputer, hosted at the Oak Ridge Leadership Computing Facility in Tennessee, United States. Frontier is a significant electricity consumer, drawing 8–30 MW; this massive energy demand produces significant waste heat, requiring extensive cooling measures. Although harnessing this waste heat for campus heating is a sustainability goal at Oak Ridge National Laboratory (ORNL), the 30 °C–38 °C waste heat temperature poses compatibility issues with standard HVAC systems. Heat pump systems, prevalent in residential settings and some industries, can efficiently upgrade low-quality heat to usable energy for buildings. Thus, heat pump technology powered by renewable electricity offers an efficient, cost-effective solution for substantial waste heat recovery. However, a major challenge is the absence of benchmark data on high-performance computing (HPC) heat generation and waste heat profiles. This paper reports power demand and waste heat measurements from an ORNL HPC data centre, aiming to guide future research on optimizing waste heat recovery in large-scale data centres, especially those of HPC calibre.

97 MATHEMATICS AND COMPUTING↗

Surface Merging Technique to Design GA-Optimized Heat Sinks

High-power density inverters require efficient and small heat dissipation systems. For liquid cooling systems, an effective heat sink design is important to enable higher heat transfer and keep the pressure drop within reasonable limits. A heat sink geometry generated from an extruded, 1D fast Fourier transform can achieve more even temperature distribution and improved heat transfer than a conventional heat sink. Building on this concept, this paper proposes a new heat sink geometry creation algorithm. Instead of one plane profile being extruded, multiple plane profiles, each created from the fast Fourier transform method, are subsequently merged by smooth surfaces along the flow direction of the heat sink. Thus, a 3D heat sink geometry is created that enables 3D coolant flow and efficient heat transfer. The volume of this design was reduced by 50% compared with pin fin heat sinks. Compared with extruded 1D fast Fourier transform heat sinks, the proposed design showed an approximately 5% device temperature reduction and a 20% pressure drop reduction.

Barua, Himel↗

ORGANIC RANKINE CYCLE TURBINE AND HEAT EXCHANGER SIZING FOR LIQUID AIR COMBINED CYCLE

Cryogenic energy storage offers several opportunities to design turbomachinery and other equipment for novel cycles. This paper presents the design and analysis of turbomachinery and heat exchangers for an Organic Rankine Cycle (ORC) subsystem for a hybrid energy storage concept. The Liquid Air Combined Cycle is an energy storage system that stores air at cryogenic conditions at times with high variable renewable energy to be dispatched along with a gas turbine to recover the exhaust heat. In order to re-vaporize the air, the liquid air is coupled with an ORC as an additional bottoming cycle. The ORC turbine is expected to expand the fluid with a pressure ratio of nearly 30 and a flow rate of approximately 45 kg/s. Sizing calculations for both a radial and axial turbine solution were performed over a range of speeds and stages to determine the optimal design point. The results show that either an axial (8- or 9-stage) or radial (four stages at two shaft speeds) turbine are capable of handling the pressure ratios. Further trades of the two configurations would be required to determine the best option. The ORC system also incorporates five heat exchangers to distribute heat, vaporize the liquid air, or recover exhaust heat from the gas turbine. Three heat exchangers were analyzed to understand the size of heat exchangers and pressure drop for the overall system. Different types of heat exchangers were explored for the different purposes, including plate-fin heat exchangers, gasketed plate heat exchangers and shell-in-tube heat exchangers. It was determined that the ORC recuperator, liquid-air vaporizer, and vaporized air pre-heater would be counter-flow heat exchangers using a gasketed plate design. Keywords: Energy Storage, Liquid Air Energy Storage, Organic Rankine Cycle

Pryor, Owen↗

Heat of Mixing During Fast Charge/Discharge of a Li-Ion Cell: A Study on NMC523 Cathode

Predicting temperature rise accurately during fast charge/discharge of a Li-ion cell is essential to avoid thermal runaway and extend battery life. While modeling the temperature rise, it is necessary to model the heat generation correctly. Heat of mixing, one of the four main sources of heat generation in a Li-ion battery, has often been considered insignificant and therefore excluded from modeling. When included, it is modeled using the expression from a Taylor expansion approximation. In this work, we have shown the conditions when including the heat of mixing becomes important and quantified the error associated with using the Taylor expansion, especially under high charge/discharge conditions. Consequently, we carry out the calculation of the rate of enthalpy change and the heat generation rate from the most fundamental equation for the rate of the total enthalpy change without simplifying assumptions or approximations. The heat generation rate calculated doing so naturally includes irreversible, reversible and mixing heat. We then exclusively separate out the heat of mixing by subtracting the rate of enthalpy change by reaction from the rate of the total enthalpy change. Results show that the contribution of heat of mixing in the total heat generated increases with the charge/discharge rate and is as large as 23% for a 6 C discharge. This result suggests that while modeling heat generation for fast charge/discharge, it is necessary to include the heat of mixing and avoid calculating it using the Taylor expansion approximation.

25 ENERGY STORAGE↗