Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Harmonization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

High harmonic fast wave heating efficiency enhancement and current drive at longer wavelength on the National Spherical Torus Experiment

High harmonic fast wave heating and current drive (CD) are being developed on the National Spherical Torus Experiment [M. Ono et al., Nucl. Fusion 41, 1435 (2001)] for supporting startup and sustainment of the spherical torus plasma. Considerable enhancement of the core heating efficiency ({eta}) from 44% to 65% has been obtained for CD phasing of the antenna (strap-to-strap {phi}=-90 deg., k{sub {phi}}=-8 m{sup -1}) by increasing the magnetic field from 4.5 to 5.5 kG. This increase in efficiency is strongly correlated to moving the location of the onset density for perpendicular fast wave propagation (n{sub onset}{proportional_to}Bxk{sub parallel}{sup 2}/{omega}) away from the antenna face and wall, and hence reducing the propagating surface wave fields. Radio frequency (RF) waves propagating close to the wall at lower B and k{sub parallel} can enhance power losses from both the parametric decay instability (PDI) and wave dissipation in sheaths and structures around the machine. The improved efficiency found here is attributed to a reduction in the latter, as PDI losses are little changed at the higher magnetic field. Under these conditions of higher coupling efficiency, initial measurements of localized CD effects have been made and compared with advanced RF code simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Disk-shaped Bose-Einstein condensates in the presence of an harmonic trap and an optical lattice

We study the existence and stability of solutions of the two-dimensional nonlinear Schroedinger equation in the combined presence of a parabolic and a periodic potential. The motivating physical example consists of Bose-Einstein condensates confined in an harmonic (e.g., magnetic) trap and an optical lattice. By connecting the nonlinear problem with the underlying linear spectrum, we examine the bifurcation of nonlinear modes out of the linear ones for both focusing and defocusing nonlinearities. In particular, we find real-valued solutions (such as multipoles) and complex-valued ones (such as vortices). A primary motivation of the present work is to develop ''rules of thumb'' about what waveforms to expect emerging in the nonlinear problem and about the stability of those modes. As a case example of the latter, we find that among the real-valued solutions, the one with larger norm for a fixed value of the chemical potential is expected to be unstable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detection of a new parametric decay instability branch in TST-2 during high harmonic fast wave heating

Parametric decay instability (PDI) is often observed in the TST-2 spherical tokamak during high harmonic fast wave heating by rf pickup probes. The frequency spectrum exhibits lower and upper sideband peaks in addition to the pump wave at f{sub 0}=21 MHz. Two types of PDI are observed. One is the well-known decay into the ion-cyclotron quasimode (nf{sub ci}) and the ion Bernstein wave (f{sub 0}-nf{sub ci}). The other is a newly found decay with the sideband frequency between f{sub 0} and f{sub 0}-f{sub ci}. The frequency difference between this sideband and the pump increases in proportion to B{sub t}. Moreover, high-speed visible light measuring systems with photomultiplier tubes or hybrid photodetectors viewing the plasma core detected oscillation of light emission at around f{sub 0}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Propagation of Non-harmonic Wave Packets in Stratified Media

We consider the problem of reconstructing non-harmonic wave packets of the internal gravity waves generated by a source moving in a horizontally stratified medium. The solution is proposed in terms of modes, propagating independently at the adiabatic approximation, and described as a non-integral degree series of a small parameter characterizing the stratified medium.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Explosive Boiling In Carbon Target Irradiated By Third Harmonic Of Nd :YAG Laser

In order to identify the physical phenomena responsible to the formation of droplets onto thin films grown during laser ablation, and to correlate between the appearance of those droplets versus the laser flux, we have measured the amount of ejected matter for carbon target irradiated by a third harmonic of Nd:YAG laser by changing laser flux. The measurement was achieved by a quartz microbalance placed in front of the target. The obtained results show at first a linear increase of the ejected material followed by a saturation behavior, and then an abrupt increase of the ablated mass beyond a laser Intensity of 3,64x10{sup 10} W/cm{sup 2}. This increasing is assigned to the homogeneous nucleation of bubbles in a layer of the molten material, also called phase explosion, the surface temperature of the target will approaches the critical thermodynamic temperature (T{sub tc}). We have also measured time-of-flight (TOF) distributions of positives ions of carbons in the plasma using a charge collector. The TOF signals have been fitted with a shifted Maxwellian distribution function. This has allowed us to estimate the critical temperature T{sub tc} of the material.

36 MATERIALS SCIENCE↗

Focused Ultrasound Surgery Control Using Local Harmonic Motion: VX2 Tumor Study

The objective of this study was to develop a real-time method for controlling focused ultrasound surgery using ultrasound imaging. The approach uses measurements of localized harmonic motion (LHM) in order to perform controlled FUS exposures by detecting changes in the elastic properties of tissues during coagulation. Methods: Nine New Zealand rabbits with VX2 tumors implanted in the thigh were used for this study. LHM was generated within the tumors by periodic induction of radiation force using a FUS transducer (80-mm focal length, 100-mm diameter, 20-mm central hole, 1.485-MHz). Tissue motion was tracked by collecting and cross-correlating RF signals during the motion using a separate diagnostic transducer (3-kHz PRF, 5-MHz). After locating the tumor in MR images, a series of sonications were performed to treat the tumors using a reduction in LHM amplitude to control the exposure. Results: LHM was successfully used to control the sonications. A LHM amplitude threshold value was determined at which changes were considered significant and then the exposure was started and stopped when the LHM amplitude dropped below the threshold. The appearance of a lesion was then verified by MRI. The feasibility of LHM measurements to control FUS exposure was validated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Simulation Model for Local Harmonic Motion Monitoring of Focused Ultrasound Surgery

A computational model for local harmonic motion (LHM) imaging-based monitoring of high-intensity focused ultrasound surgery (FUS) is presented. LMH technique is based on a focused ultrasound radiation force excitation, which induces local mechanical vibrations at the focal region. These pulse-echo imaged vibrations are then used to estimate the mechanical properties of the sonication region. LHM has been proven to be feasible for FUS monitoring because changes in the material properties during the coagulation affect the measured displacements. The presented model includes separate models to simulate acoustic fields, sonication induced temperature elevation and mechanical vibrations, and pulse-echo imaging of the induced motions. These simulation models are based on Rayleigh integral, finite element, and spatial impulse response methods. Simulated temperature rise and vibration amplitudes have been compared with in vivo rabbit experiments with noninvasive MRI thermometry.

60 APPLIED LIFE SCIENCES↗

Real-time Focused Ultrasound Surgery (FUS) Monitoring Using Harmonic Motion Imaging (HMI)

Monitoring changes in tissue mechanical properties to optimally control thermal exposure is important in thermal therapies. The amplitude-modulated (AM) harmonic motion imaging (HMI) for focused ultrasound (HMIFU) technique is a radiation force technique, which has the capability of tracking tissue stiffness during application of an oscillatory force. The feasibility of HMIFU for assessing mechanical tissue properties has been previously demonstrated. In this paper, a confocal transducer, combining a 4.5 MHz FUS transducer and a 3.3 MHz phased array imaging transducer, was used. The FUS transducer was driven by AM wave at 15 Hz with an acoustic intensity (I{sub spta}) was equal to 1050 W/cm{sup 2}. A lowpass digital filter was used to remove the spectrum of the higher power beam prior to displacement estimation. The resulting axial tissue displacement was estimated using 1D cross-correlation with a correlation window of 2 mm and a 92.5% overlap. A thermocouple was also used to measure the temperature near the ablated region. 2D HMI-images from six-bovine-liver specimens indicated the onset of coagulation necrosis through changes in amplitude displacement after coagulation due to its simultaneous probing and heating capability. The HMI technique can thus be used to monitor temperature-related stiffness changes of tissues during thermal therapies in real-time, i.e., without interrupting or modifying the treatment protocol.

60 APPLIED LIFE SCIENCES↗

Nonlinear cyclotron harmonic absorption

Nonlinear oscillations of particle's energy occur when a particle stays in a resonance zone. In this work, we found that collisionless heating of particles occurs when they pass the microwave beam at first, second, and third harmonic resonances. It is found that the net energy gain of particles from the microwaves is inversely proportional to the wave frequency. It is also found that the net energy gain is dependent on the microwave beam width. The energy gain of particles from a single pass through a resonance zone has been formulated analytically. A numerical calculation has been performed and the results are in good agreement with the analytic calculation. Both analytic and numerical calculations show a strong frequency dependence and a beam width dependence of nonlinear cyclotron resonance heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Matching stationary and axisymmetric spacetimes in perturbation theory: Lichnerowicz vs. Darmois junction conditions in harmonic gauge

We farther analyse a stationary and axisymmetric global metric we have recently built, resulting from the matching between a Wahlquist perfect fluid interior and an asymptotically flat exterior. It involves the use of Lichnerowicz junction conditions and harmonic gauge, thus imposing additional restrictions to the matching that could derive into a loss of generality if one is to obtain consequences from them. We show that this is not the case since the Lichnerowicz matching, besides fixing the gauge part of the metrics, is completely equivalent to the Darmois one. This holds for the polytropic source case.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Harmonicity in supermanifolds and sigma models

We show that given an odd metric G on a supermanifold (M, A) and its associated Laplacian {delta}, it is possible to interpret harmonic superfunctions (i.e., those f is an element of A such that {delta}f = 0) as solutions to a variational problem describing a supersymmetric sigma model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electron density measurements of a field-reversed configuration plasma using a novel compact ultrastable second-harmonic interferometer

A compact high-sensitivity second-harmonic interferometer for line-integrated electron density measurements on a large plasma machine is presented. The device is based on a fiber coupled near-infrared continuous-wave Nd:YAG laser and is remotely controlled. The performances of the instrument are tested on the Irvine field-reversed configuration machine, and a sensitivity of few 10{sup 14} cm{sup -2} in measuring line integrated electron density is demonstrated with a time resolution of a few microseconds. The interferometer is self calibrated, has an impressive stability, and it does not require any further alignment after proper installation. These features make this device a real turn-key system suitable for electron density measurement in large plasma machines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diffusion coefficients from resonant interactions with electrostatic electron cyclotron harmonic waves

Pitch-angle diffusion coefficients have been calculated for resonant interaction with electrostatic electron cyclotron harmonic (ECH) waves using quasilinear diffusion theory. Unlike previous calculations, the parallel group velocity has been included in this study. Further, ECH wave intensity is expressed as a function of wave frequency and wave normal angle with respect to ambient magnetic field. It is found that observed wave electric field amplitudes in Earth's magnetosphere are sufficient to set electrons on strong diffusion in the energy ranges of a few hundred eV. However, the required amplitudes are larger than the observed values for keV electrons and higher by about a factor of 3 compared to past calculations. Required electric field amplitudes are smaller at larger radial distances. It is concluded that ECH waves are responsible for diffuse auroral precipitation of electrons with energies less than about 500 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterisation of the Sub-Harmonic Arc Detection System on JET ITER-Like Antenna

A Sub-Harmonic Arc Detection (SHAD) system has been installed on the transmission lines feeding the JET ICRF ITER-like-Antenna (ILA). Along with the commissioning of SHAD, extensive measurements of the RF field in the transmission lines were carried-out using fast sampling (125 Mb/s) oscilloscopes. The system is described, and the SHAD ability to detect arcs during ILA operation (in particular on ELMy H modes) is discussed. Overall, SHAD proved to be efficient, and in some conditions it can offer extra protection in complement to other arc detection systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synergy in Two-Frequency Fast Wave Cyclotron Harmonic Absorption in DIII-D

Fast waves (FWs) at 60 MHz and at 90 MHz are coupled to DIII-D discharges for central heating and current drive at net FW power up to 3.5 MW. The primary absorption mechanism is intended to be direct electron damping in the plasma core. In discharges at B = 2 T with fast deuteron populations from neutral beam injection, 4th and 6th deuterium cyclotron harmonic absorption on the fast ions competes with direct electron damping. Previous experiments have shown that the 6{omega}{sub D} absorption of the 90 MHz FWs is weaker than the 4{omega}{sub D} absorption of 60 MHz FWs, in agreement with a model that includes unspecified edge losses. Recent experiments have shown that if the fast deuterons are accelerated by absorption of 60 MHz (4{omega}{sub D}) FWs, adding 90 MHz power (6{omega}{sub D}) can increase the fusion neutron rate by a larger increment than is obtained with 90 MHz power alone. Details of this synergy between 4{omega}{sub D} and 6{omega}{sub D} absorption are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advances in high-harmonic fast wave physics in the National Spherical Torus Experiment

Improved core high-harmonic fast wave (HHFW) heating at longer wavelengths and during start-up and plasma current ramp-up has now been obtained by lowering the edge density with lithium wall conditioning, thereby moving the critical density for perpendicular fast-wave propagation away from the vessel wall. Lithium conditioning allowed significant HHFW core electron heating of deuterium neutral beam injection (NBI) fuelled H-mode plasmas to be observed for the first time. Large edge localized modes were observed immediately after the termination of rf power. Visible and infrared camera images show that fast wave interactions can deposit considerable rf energy on the outboard divertor. HHFW-generated parametric decay instabilities were observed to heat ions in the plasma edge and may be the cause for a measured drag on edge toroidal rotation during HHFW heating. A significant enhancement in neutron rate and fast-ion profile was measured in NBI-fuelled plasmas when HHFW heating was applied.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Harmonic Responses in 2DEG AlGaAs/GaAs HEMT Devices Due to Plasma Wave Interaction

Plasma waves are oscillations of electron density in time and space, and in deep submicron field effect transistors, typical plasma frequencies, omega{sub p}, lie in the terahertz range and do not involve any quantum transitions. Hence, using plasma wave excitation for detection and/or generation of THz oscillations is a very promising approach. In this paper, the investigation of plasma wave interaction between the plasma waves propagating in a short-channel High-Electron-Mobility Transistor (HEMT) and the radiated electromagnetic waves was carried out. Experimentally, we have demonstrated the detection of the terahertz (THz) radiation by an AlGaAs/GaAs HEMT up to third harmonic at room temperature and their resonant responses show very good agreement with the calculated results.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multitone harmonic-balance simulations of an x-ray transition-edge sensor characterized at BESSY II

We present multitone harmonic-balance (MTHB) simulations of a Ti-Au x-ray transition-edge sensor (TES) microcalorimeter in a 5x5 pixel spectrometer array. The dynamic response of the TES microcalorimeter under simulation has been extremely well characterized at the BESSY II Synchrotron Radiation Facility in Berlin. We compare our simulated results directly with these measurements, and show that the MTHB algorithm is able to simulate to great accuracy the dynamic behavior of the TES, even when saturated by 6 keV photons. In this paper, we provide a detailed account of the MTHB simulations, and discuss the impact of this work on future missions such as the International X-ray Observatory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗