Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Germanium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

High pressure Marinelli for counting low activity compressed gas samples

Quantification of low-activity noble gases in air is typically accomplished through separation of the noble gas from air followed by radiometric assay. Here, this work is aimed at quantification of radioactive noble gas in air without extraction. A high pressure aluminum Marinelli counting vessel was designed and fabricated that can be placed on a coaxial high purity germanium detector for gamma counting. Characterization of the performance of this Marinelli using MCNP modeling, large excesses of activity, and low-activity noble gas in air is discussed. Minimum detectable concentrations achieved during a 24 h count are: 5, 10, 50, and 1 Bq/m 3 for 133 Xe, 133m Xe, 131m Xe, and 135 Xe, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a multidimensional gamma-spectrometer

A high-sensitivity multidimensional gamma-spectrometer is being developed within the shallow underground laboratory at Pacific Northwest National Laboratory (PNNL, USA). The system consists of two Broad Energy Germanium (BEGe) detectors, inside a low-background lead and copper shield, fitted with a cosmic veto background reduction system. The detector has advanced functionality, including operation in single or combined detector mode, with reductions in the cosmic background by 49.6% and Compton suppression of 6.5%. For selected radionuclides this provides an overall MDA improvement of 52.7%. Utilizing both detectors for simultaneous measurements of thermally irradiated highly enriched uranium (HEU) increased peak identification and reduced uncertainty by 27.6%. The design uses commercially off-the-shelf (COTS) components, for which the configuration is described, to provide a practical and powerful solution for low-level nuclear measurements.

Compton suppression↗

Validation of a Monte Carlo HPGe detector model against irradiated foil gamma-ray spectroscopy measurements

In this study, a high-purity germanium detector Monte Carlo model was evaluated for its ability to predict activation product ratios in Fe, Cr, Ni, and stainless-steel foils. To evaluate the model, activation product ratios calculated from simulated gamma-ray spectra were compared against those from experiment measurements. Analysis shows that the detector model accurately predicts activation product ratios within 10% when free of interferences. Presence of a shield chamber greatly increases computation time, but does not provide any quantitative advantages. Overall, the model is useful for predicting activation product ratios and experiment planning.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

High-precision measurements of half-lives for 69 Ge, 73 Se, 83 Sr, 85 mSr, and 63 Zn radionuclides relevant to the astrophysical p-process via photoactivation at the Madison Accelerator Laboratory

The ground state half-lives of 69 Ge, 73 Se, 83 Sr, 63 Zn, and the half-life of the 1/2 - isomer in 85 Sr have been measured with high precision using the photoactivation technique at an unconventional bremsstrahlung facility that features a repurposed medical electron linear accelerator. The γ -ray activity was counted over about 6 half-lives with a high-purity germanium detector, enclosed into an ultra low-background lead shield. The measured half-lives are: T 1/2 ( 69 Ge) = 38.82 ± 0.07 (stat) ± 0.06 (sys) h; T 1/2 ( 73 Se) = 7.18 ± 0.02 (stat) ± 0.004 (sys) h; T 1/2 ( 83 Sr) = 31.87 ± 1.16 (stat) ± 0.42 (sys) h; T 1/2 ( 85m Sr) = 68.24 ± 0.84 (stat) ± 0.11 (sys) min; T 1/2 ( 63 Zn) = 38.71 ± 0.25 (stat) ± 0.10 (sys) min. These high-precision half-life measurements will contribute to a more accurate determination of corresponding ground-state photoneutron reaction rates, which are part of a broader effort of constraining statistical nuclear models needed to calculate stellar nuclear reaction rates relevant for the astrophysical p -process nucleosynthesis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gamma-ray spectrometry analysis methods for radioisotope dissolution and mixing for nuclear forensics applications

We report the production of surrogate nuclear explosive debris involves the dissolution of irradiated fissile material, elemental isolation, and recombination based on required fission product ratios. Gamma-ray spectrometry is used following each step to assess the radioactive fission product inventory. A high-purity germanium detector is used to measure each sample, and the detector efficiencies are determined prior to sample measurements. Through radiochemical techniques, elements are isolated and recombined into samples with specific fission product ratios. As a result, a matrix-based approach can account for imperfect chemical separations to calculate the proper mixture volumes to obtain intended volatile-to-refractory fission product ratios, or R-values.

07 ISOTOPE AND RADIATION SOURCES↗

Characterization of PIPS detectors for measurement of radioxenon

The International Monitoring System arm of the Comprehensive Nuclear-Test-Ban Treaty Organization utilizes sampling of atmospheric radioxenon to scan the world for nuclear testing events. Current designs utilized in the field involve plastic scintillator cells run in coincidence with Sodium Iodide (NaI) or High Purity Germanium (HPGe) detectors. The use of plastic scintillators as electron detectors exhibit some issues in comparison to other materials. Silicon detectors are analyzed as an alternative to plastic scintillators for beta detection based on their higher energy resolution and lowered memory effect. A radioxenon detection setup was created with the intent of measuring radioxenon samples using coincidence counting between silicon and NaI detectors as well as silicon and HPGe. Finally, the absolute efficiency of both setups is calculated and compared.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Design and validation of a gamma-ray scanning system for measuring irradiated nuclear fuel

We report a prototype gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. This paper documents the design process, modeling and the laboratory characterization performed to validate the system. The modeling of the system was done using the Monte Carlo N-Particle code with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector. The characterization included measurements of calibrated radiation sources in different geometries, and calculations for absolute efficiency and dead time. Benchmark measurements were performed scanning an irradiated fuel rodlet containing ten pellets of 4.9% enriched UO2 in zirconium alloy. These results were compared to simulated spectra to further help characterize the detector model. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel; comparison of the results from this prototype system's assay of the irradiated fuel rodlet are in agreement with previously estimated results.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Synchrotron-based X-ray fluorescence imaging and elemental mapping from biological samples

The present study utilized the new hard X-ray microspectroscopy beamline facility, X27A, available at NSLS, BNL, USA, for elemental mapping. This facility provided the primary beam in a small spot of the order of {approx}10 {mu}m, for focussing. With this spatial resolution and high flux throughput, the synchrotron-based X-ray fluorescent intensities for Mn, Fe, Zn, Cr, Ti and Cu were measured using a liquid-nitrogen-cooled 13-element energy-dispersive high-purity germanium detector. The sample is scanned in a 'step-and-repeat' mode for fast elemental mapping measurements and generated elemental maps at 8, 10 and 12 keV, from a small animal shell (snail). The accumulated trace elements, from these biological samples, in small areas have been identified. Analysis of the small areas will be better suited to establish the physiology of metals in specific structures like small animal shell and the distribution of other elements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Benchmarking the repeatability of a pneumatic cyclic neutron activation analysis facility using 16 O(n,p) 16 N for nuclear forensics

A target was prepared for cyclic neutron activation analysis by heat sealing lithium-carbonate in polyethylene. The target was cyclically irradiated 50 times using a Thermo-Scientific accelerator based deuterium–tritium fusion neutron generator. During counting periods, gamma-rays emitted by 16 N were detected using three high-purity germanium detectors acquiring data in list-mode. Total counts acquired in each spectrum were compared between the three detectors to examine variability in geometric positioning of the target and variability of the generator intensity throughout the experiment. These two effects were determined to be the primary sources of variation in the measured counts. Variation in target positioning and generator intensity were found to increase the standard deviation by 34% and 33%, respectively. Transit times to the detector were found to be slower and more variable than transit to the generator but were well below the half second threshold needed to measure short-lived radionuclides with half-lives on the order of seconds. The standard deviation in irradiation time was found to be less than 1 milliseconds. The impact on statistical variability in the measured counts was negligible relative to the two primary sources of variation. Spectra acquired from each cycle were summed together. The sum of the peak areas from the 6.1 MeV gamma-ray and its corresponding single and double escape peaks were used to measure the half-life of 16N. The result of 7.108(15) seconds derived from data suggests that the currently published value of 7.13(2) seconds has minimal systematic bias induced by background.

43 PARTICLE ACCELERATORS↗

Black Hills State University Underground Campus

The Black Hills State University Underground Campus (BHUC) houses a low background counting facility on the 4850' level of the Sanford Underground Research Facility. As of the date of this paper, there are currently four ultra-low background, high-purity germanium detectors installed in the BHUC and it is anticipated four more detectors will be installed within a year. In total, the BHUC will be able to accommodate up to twelve detectors with space inside a class 1000 cleanroom, an automated liquid nitrogen fill system, on-site personnel assistance and other required utilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent Bremsstrahlung-based Assays of 210Pb in Lead and Comments on Current Availability of Low-Background Lead in North America

Abstract Low-background lead for radiation measurement shielding is often assayed for 210Pb to ensure acceptable backgrounds. Samples of lead assayed with a germanium spectrometer calibrated for bremsstrahlung-based assay of 210Pb provide a view into the 210Pb content of commercial lead in the U.S. (other than stockpiled Doe Run lead). Results suggest that the loss of lead smelting in the U.S. has eliminated the traditional supply of “low background” lead (~30 Bq·kg-1), and indicate current commercial supplies contain roughly an order of magnitude higher 210Pb levels.

Low background, gamma spectroscopy, lead, bremsstr↗

Half-lives of 101 Rh g and 108 Ag m

Using long-term gamma-ray spectroscopy with high resolution germanium detectors and a ratio method, the half-lives of 101 Rh g and 108 Ag m have been determined to be 4.07 ± 0.05 years and 448 ± 27 years, respectively. These results are then compared with previously reported values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Two Extraordinary AmLi Neutron Sources

Two legacy AmLi sources, MRC-101 and MRC-103, are routinely used for neutron detector characterization and testing campaigns that Pacific Northwest National Laboratory manages for the Defense Threat Reduction Agency within the U.S. Department of Defense. However, applicability of source measurement data has been substantially limited due to the lack of original manufacturer documentation and cross comparison to other sources. This paper summarizes results of the measurement campaign conducted to better quantify source radionuclide content, neutron energy spectrum and emission rate of the AmLi sources. The source characterization study consisted of three major consecutive measurement exercises. First, gamma spectrometry measurements using a high purity germanium detector were used to estimate the radionuclide content and potential impurities of the AmLi sources. Then neutron spectral measurements were taken to determine the unique neutron energy distribution. Finally, assessments of the total neutron yields of the sources were made with measurements in a neutron well counter. The neutron detection efficiency for these measurements was determined via detailed Monte Carlo modeling based on the neutron energy distribution measured with the rotating neutron spectrometer. The most exciting and unexpected finding of the study was a significant contamination of the source material with beryllium, contributing up to 17% to the total neutron emission rate and correspondingly changing the neutron energy spectrum. Also, the obtained lithium-only portion of the measured energy distribution of the sources was compared against several AmLi spectra previously reported by different researchers.

AWCC, AmLi, beryllium contamination, neutron spect↗

Fast neutron activation of ubiquitous materials

Nuclear explosions expose ubiquitous materials to large numbers of neutrons, producing a variety of radioactive isotopes. To simulate such phenomena from both fission and thermonuclear explosions, we irradiated 29 different targets with approximately 3 and 14 MeV neutrons and measured the beta-delayed gamma rays using germanium detectors. Therefore, for each neutron energy, the expected radioisotopes, half-lives, and gamma ray energies were deduced. From measurements of the ratios of activities of the radionuclides produced by neutron irradiations, we were able to identify several materials that are particularly sensitive to the neutron energy spectra.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The 40 Ar(d,p) 41 Ar cross section between 3–7 MeV

To determine the safety of using argon as a deuteron beam stopping material, the 40 Ar(d,p) 41 Ar cross section was measured at average deuteron energies of 3.6 MeV, 5.5 MeV, and 7.0 MeV using an activation method. A 16-MeV deuteron beam produced by Lawrence Berkeley National Laboratory’s 88-Inch Cyclotron was degraded to each energy by nickel foils and the front wall of an aluminum gas chamber. The reduced-energy deuterons were used to activate a sample of nat Ar gas. After each irradiation, the gas chamber’s 41 Ar activation was measured with a high-purity germanium detector. The cross sections measured were larger than a previous measurement by ~40%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Discrimination of phosgene from cyanogen chloride in recovered chemical munitions using tagged neutron interrogation with high-resolution gamma-ray spectroscopy

The Associated Particle technique has recently been utilized with a germanium-based high-resolution $\gamma$-ray spectrometer and assessed for its capability to improve field identification of recovered chemical warfare (CW) materiel through prompt gamma-ray neutron activation analysis (PGNAA) measurements. An accurate chemical identification is necessary for the safe handling, destruction, and disposal of such hazardous items. A particularly challenging pair of CW agents commonly found in recovered munitions are phosgene (CG) and cyanogen chloride (CK), which have two of three elements in common, i.e. chlorine and carbon, but differ in the third being either oxygen or nitrogen. The detection of both latter elements is complicated by high oxygen concentration in the field environment which interferes with the small signal produced from the chemical agents. The matter is further complicated by the precautionary field practice of overpacking recovered munitions with vermiculite in larger steel multiple round containers (MRCs), which places additional oxygen-rich material around the munition while further attenuating an already weak signal emitted from the munition center. Here, this work reports quantitative results from realistic field measurements of CG and CK simulants in mock 4.2-inch mortar rounds overpacked with vermiculite in a large MRC. Results obtained with the AP technique are compared to those obtained with the traditional PGNAA approach for both overpacked- and bare-munition measurements. The AP technique is shown to provide a much more confident discrimination between the two chemicals, particularly for the more challenging field-relevant overpacked measurements, where a significant gain in sensitivity to all the key elements chlorine, carbon, nitrogen and oxygen is achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of measurement techniques and sorption of radium-226 in low and high salinity aqueous samples

Human activities have the potential to redistribute radium (Ra) in the marine environment in a manner that may necessitate monitoring or management of subsequent human or environmental exposures. There is therefore a need to identify accurate and accessible techniques for Ra measurement in high salinity samples and to describe the distribution of Ra in estuarine and marine environments, but most efforts in these areas have focused on low salinity matrices. In addition, rapid and reliable measurements are crucial for time-sensitive samples such as short-lived isotopes or emergency situations. The objective of this study is to describe the limits of detection, cost, and relative ease for measurement of Ra in both low and high salinity aqueous samples via three analytical methods: liquid scintillation counting (LSC), high purity germanium (HPGe) gamma spectrometry, and inductively coupled plasma mass spectrometry (ICP-MS). To contextualize these measurements for real-world scenarios, the partitioning of 226 Ra to substrates relevant to the marine environment was also characterized. Although HPGe detection with solid phase extraction had the lowest limit of detection for low salinity samples (0.27 Bq L −1 ), poor 226 Ra recovery for high salinity samples and high materials costs make this method prohibitive for many users. Limits of detection for high salinity samples were lower for LSC (1.28 Bq L −1 ) than for ICP-MS without dilution (11.4 Bq L −1 ), but significant and unexpected degradation of the high salinity LSC standards was observed after six months. Furthermore, our preferred measurement method for high salinity Ra samples is ICP-MS with sample dilution as necessary to reduce matrix effects.

07 ISOTOPE AND RADIATION SOURCES↗

Precise half-life determination of 131 Ba and 125 Xe

Barium-131 and Xenon-125 are valuable radioisotopes with numerous scientific and medical applications. Here, we produced both isotopes via proton irradiation of a cesium iodide (CsI) target at the Brookhaven Tandem Van de Graaff accelerator (BTVG). Following irradiation, we conducted systematic γ-ray spectroscopy measurements at the National Nuclear Data Center (NNDC) decay station using a calibrated High-Purity Germanium (HPGe) detector, collecting data over a 2-month period (spanning approximately 4.5 half-lives for 131 Ba). Through careful analysis of the characteristic γ-ray emissions from both isotopes, we determined the half-life of 131 Ba to be 11.55(6) days, which agrees with the previously evaluated value. For 125 Xe, we measured a half-life of 16.56(8) hours, slightly lower than the evaluated value.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗