PU/SS EUTECTIC ASSESSMENT IN 9975 PACKAGINGS IN A STORAGE FACILITY DURING EXTENDED FIRE

In a radioactive material (RAM) packaging, the formation of eutectic at the Pu/SS (plutonium/stainless steel) interface is a serious concern and must be avoided to prevent of leakage of fissile material to the environment. The eutectic temperature for the Pu/SS is rather low (410 C) and could seriously impact the structural integrity of the containment vessel under accident conditions involving fire. The 9975 packaging is used for long term storage of Pu bearing materials in the DOE complex where the Pu comes in contact with the stainless steel containment vessel. Due to the serious consequences of the containment breach at the eutectic site, the Pu/SS interface temperature is kept well below the eutectic formation temperature of 410 C. This paper discusses the thermal models and the results for the extended fire conditions (1500 F for 86 minutes) that exist in a long term storage facility and concludes that the 9975 packaging Pu/SS interface temperature is well below the eutectic temperature.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dynamic modeling of a single-stage downward firing, entrained flow gasifier

The gasifier is the heart of the integrated gasification combined cycle (IGCC), a technology that has emerged as an attractive alternative to conventional coal-fired power plant technology due to its higher efficiency and cleaner environmental performance especially with the option of CO{sub 2} capture and sequestration. Understanding the optimal performance of the gasifier is therefore paramount for the efficient operation of IGCC power plants. Numerous gasifier models of varying complexity have been developed to study the various aspects of gasifier performance. These range from simple one-dimensional (1D) process-type models to rigorous higher order 2-3D models based on computational fluid dynamics (CFD). Whereas high-fidelity CFD models can accurately predict most key aspects of gasifier performance, they are computationally expensive and typically take hours to days to execute on high-performance computers. Therefore, faster 1D partial differential equation (PDE)-based models are required for use in dynamic simulation studies, control system analysis, and training applications. A number of 1D gasifier models can be found in the literature, but most are steady-state models that have limited application in the practical operation of the gasifier. As a result, 1D PDE-based dynamic models are needed to further study and predict gasifier performance under a wide variety of process conditions and disturbances. In the current study, a 1D transient model of a single-stage downward-fired GE/Texaco-type entrained-flow gasifier has been developed. The model comprises mass, momentum and energy balances for the gas and solid phases. The model considers the initial gasification processes of water evaporation and coal devolatilization. In addition, the key heterogeneous and homogeneous chemical reactions have been modeled. The resulting time-dependent PDE model is solved using the well-known method of lines approach in Aspen Custom Modeler®, whereby the PDEs in the spatial domain are discretized and the resulting differential algebraic equations (DAEs) are then integrated over time using a dynamic integrator. The dynamic response results of the gasifier performance parameters to certain disturbances commonly encountered during practical operation are presented. These disturbances include ramp and step changes to input variables such as coal flow rate, oxygen-to-coal ratio and water-to-coal ratio among others. Comparison of model predictions to available dynamic data will also be discussed.

01 COAL, LIGNITE, AND PEAT↗

Practical Thermal Evaluation Methods For HAC Fire Analysis In Type B Radiaoactive Material (RAM) Packages

Title 10 of the United States Code of Federal Regulations Part 71 for the Nuclear Regulatory Commission (10 CFR Part 71.73) requires that Type B radioactive material (RAM) packages satisfy certain Hypothetical Accident Conditions (HAC) thermal design requirements to ensure package safety during accidental fire conditions. Compliance with thermal design requirements can be met by prototype tests, analyses only or a combination of tests and analyses. Normally, it is impractical to meet all the HAC using tests only and the analytical methods are too complex due to the multi-physics non-linear nature of the fire event. Therefore, a combination of tests and thermal analyses methods using commercial heat transfer software are used to meet the necessary design requirements. The authors, along with his other colleagues at Savannah River National Laboratory in Aiken, SC, USA, have successfully used this 'tests and analyses' approach in the design and certification of several United States' DOE/NNSA certified packages, e.g. 9975, 9977, 9978, 9979, H1700, and Bulk Tritium Shipping Package (BTSP). This paper will describe these methods and it is hoped that the RAM Type B package designers and analysts can use them for their applications.

42 ENGINEERING↗

High-Efficiency Thermal Integration of Closed Supercritical CO 2 Brayton Power Cycles with Oxy-Fired Heaters (Final Report)

The primary goal of this project was to prepare designs for indirect-heated, oxy-combustion-based, coal-fired, supercritical carbon dioxide (sCO 2 ) power plants, to assess the potential cost and performance benefits that this marriage of technologies might offer when compared to more conventional, oxy / coal-fired steam-Rankine power plants. The oxy-combustion technologies under investigation in this project were atmospheric-pressure, oxy-pulverized coal (PC) cases as well as chemical looping combustion cases. In addition, a smaller-scale air-PC plant without CO 2 capture integrated with a sCO 2 power cycle was also designed and compared to a comparable steam-Rankine cycle baseline.

Maxson, Andrew↗

Performance Baseline for Direct-Fired sCO2 Cycles

NETL has conducted an evaluation of the performance and emissions for a direct coal-fired supercritical CO2 (sCO2) power plant, which has recently received interest as a potentially lower-cost, fossil-fuelled power source with inherent amenability to carbon capture. This study describes a baseline coal-fired cycle configuration, where coal is first gasified and cleaned in order to avoid introducing sulfur and particulate matter into the sCO2 cycle, with the sCO2 cycle’s oxy-combustor operating on syngas. The baseline sCO2 plant design yields a net plant thermal efficiency of 37.7% (HHV), with 98.1% CO2 capture at 99.4% purity. This compares favorably to the reference IGCC plant, which has a 31.2% net HHV thermal efficiency, and 90.1% CO2 capture rate at 99.99% purity. The sensitivity of the sCO2 plant’s performance to its process variables is discussed, as well as their effect on plant operability and cost surrogate variables.

Shelton, Walter↗

Performance Baseline for Direct-Fired sCO2 Cycles

NETL has conducted an evaluation of the performance and emissions for a direct coal-fired supercritical CO2 (sCO2) power plant, which has recently received interest as a potentially lower-cost, fossil-fuelled power source with inherent amenability to carbon capture. This study describes a baseline coal-fired cycle configuration, where coal is first gasified and cleaned in order to avoid introducing sulfur and particulate matter into the sCO2 cycle, with the sCO2 cycle’s oxy-combustor operating on syngas. The baseline sCO2 plant design yields a net plant thermal efficiency of 37.7% (HHV), with 98.1% CO2 capture at 99.4% purity. This compares favorably to the reference IGCC plant, which has a 31.2% net HHV thermal efficiency, and 90.1% CO2 capture rate at 99.99% purity. The sensitivity of the sCO2 plant’s performance to its process variables is discussed, as well as their effect on plant operability and cost surrogate variables.

Weiland, Nathan↗

Resilient buildings for fire-adapted landscapes: EE and flexible loads integrated with solar and storage microgrids

Energy efficiency (EE) and flexible loads can be part of a resilient buildings packagewhen they are combined with solar and storage in a clean energy microgrid to reduce the carbonfootprint of buildings and enable resilience to extreme events. Recent large wildfires and an emerging understanding of the fire-adapted landscapes in the American West underscore the urgency of work towards scaling and commercializing these systems. For example, a recent power shutoff in Northern California (October 9-12, 2019) resulted in 738k customers disconnected at the peak of the outage and is emblematic of challenges to come. Our paper reports on insights from a clean energy microgrid deployment pilot that integrates a 50 kWAC PV array, a 109 kW / 174 kWh battery system, switchgear to safely isolate from the regional power system, and communicating controllers for HVAC and refrigeration. The project will be commissioned in May 2020 and is sited at a critical infrastructure site in rural Northern California – in this case a gasoline station with convenience store. Our experience and results shed light on capabilities of integrated microgrids to provide value to customers during blue sky conditions and resilience during black sky days with high fire risk, and what opportunities and barriers exist for scaling these integrated microgrid systems in the near term. We use a simulation model to estimate how EE and flexibility can extend the run time of solar and storage, improving the reliability of power at critical sites.

Alstone, Peter↗

Dynamic Simulation of a Sub-Critical Coal Fired Power Plant

In order to address the demanding operating conditions for remaining coal-fired power plants, a dynamic model and a suite of tools have been developed for studying load cycling and to find optimization opportunities. A sub-critical steam cycle power plant was modeled in a flow-sheet modeling tool, APROS™. The model represented the firing system, economizer, evaporator, superheat, and reheat systems. Four loads from 100% TMCR to 25% TMCR were calibrated and tested such that low-to-high cycling could be studied. The model was run through various load cycles; one of which is presented here. This modeling is a prototype for general use in developing cutting edge controls products and for maximizing economic, low-emissions, and efficient operation of the existing coal power fleet.

Braun, Timothy↗

Case studies on recent fossil-fired plants

The article summarises the findings of case studies on fossil-fired power plants carried out by the IEA Clean Coal Centre for the IEA at the request of world leaders at the Gleneagles G8 Summit in July 2005. The studies compared the cost, efficiency and emissions of eight recently constructed coal-fired plants using pulverized coal combustion with subcritical, supercritical or ultra-supercritical steam turbine cycles. Also included was a review of IGCC developments. A case study of a natural gas combined-cycle plant was included for comparison. The full report has been published by the IEA. 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Repowering a small coal-fired power plant

The Arkansas River Power Authority (ARPA) Lamar Repowering Project is moving forward. The new generator, capable of producing 18 MW of electricity, is scheduled to be online in June 2008 bringing the total generation to 43 MW. New coal handling equipment, with infrared fire detectors, is almost complete. The new 18 MW steam turbine will be cooled by an air-cooled condenser. Coal will be delivered in a railroad spur to an unloading site then be unloaded onto a conveyor under the tracks and conveyed to two storage domes each holding 6000 tons of coal. It will be drawn out of these through an underground conveyor system, brought into a crusher, conveyed through overhead conveyors and fed into the new coal- fired fluidized bed boilers. 1 photo.

01 COAL, LIGNITE, AND PEAT↗

Options for reducing a coal-fired plant's carbon footprint: Part. 1

Caps on greenhouse gas emissions are imminent in the US and they will change how we design tomorrow's coal-fired power plants. Efforts are already under way to develop alternative capture and sequestration technologies, mainly for CO{sub 2}. Unfortunately, the proposed processes all consume lots of energy, reducing plants' net output and efficiency. In Part 1 of our look at these technologies, we list and quantify the impacts of post combustion removal of CO{sub 2} from a coal plant's flue gas. Next month, in Part. 2 we will do the same for four other CO{sub 2} reduction techniques: oxyfuel combustion, using higher-temperature and higher-pressure boilers, cofiring biomass, and replacing some coal-fired capacity with renewable capacity. 10 figs., 4 tabs.

01 COAL, LIGNITE, AND PEAT↗

Application of hybrid coal reburning/SNCR processes for NOx reduction in a coal-fired boiler

Boilers in Beijing Thermal Power Plant of Zhongdian Guohua Co. in China are coal-fired with natural circulation and tangential fired method, and the economical continuous rate is 410 ton per hour of steam. Hybrid coal reburning/SNCR technology was applied and it successfully reduced NOx to about 170 mg/Nm{sup 3} from about 540 mg/Nm{sup 3}, meanwhile ammonia slip was lower than 10 ppm at 450-210 t/h load and the total reduction efficiency was about 70%. Normal fineness pulverized coal from the bin was chosen as the reburning fuel and the nozzles of the upper primary air were retrofitted to be used as the reburning fuel nozzles. The reducing agent of SNCR was an urea solution, and it was injected by the four layer injectors after online dilution. At 410 t/h load, NOx emission was about 300 mg/Nm{sup 3} when the ratio of reburning fuel to the total fuel was 25.9%-33.4%. Controlling the oxygen content of the gas in the reversal chamber to less than 3.4% resulted in not only low NOx emission but also high combustion efficiency. Ammonia slip distribution in the down gas pass was uneven and ammonia slip was higher in the front of the down gas pass than in the rear of the down gas pass. NSR and NOx reduction were proportional to each other and usually resulted in more ammonia slip with reduction in NOx. About 100 mg/Nm{sup 3} NOx emission could be achieved with about 40 ppm NH{sub 3} slip at 300-450 t/h, and ammonia slip from the SNCR reactions could be used as reducing agent of SCR, which was favorable for the future SCR retrofit.

01 COAL, LIGNITE, AND PEAT↗

Lessons learned in upgrading and refurbishing older coal-fired power plants - a best practices guide for developing APEC economies

The report reviews upgrading and refurbishment projects recently implemented by coal-fired power plants in developing APEC economies, and includes a Best Practice Guide for 15 classes of upgrade and refurbishment items to aid in decision making. There is an urgent need to optimize the performance of older coal-fired power plants in the Asia Pacific region. Refurbished power plants are more efficient and emit less CO{sub 2}. Plants can also be upgraded with new pollution control equipment to emit less CO{sub 2}, SO{sub 2} NOx, particulates and other emissions, including mercury. 20 figs., 6 tabs., 4 apps.

01 COAL, LIGNITE, AND PEAT↗

Best practices in environmental monitoring for coal-fired power plants: lessons for developing Asian APEC economies

The report assesses environmental monitoring and reporting by individual coal-fired power plants, makes recommendations regarding how monitoring should be applied, and evaluates the interrelationship of monitoring and regulation in promoting CCTs. Effective monitoring is needed to ensure that power plants are performing as expected, and to confirm that they are complying with applicable environmental regulations. Older coal-fired power plants in APEC economies often have limited monitoring capabilities, making their environmental performance difficult to measure. 585 refs., 5 figs., 85 tabs.

01 COAL, LIGNITE, AND PEAT↗

Executive roundtable on coal-fired generation

Power Engineering magazine invited six industry executives from the coal-fired sector to discuss issues affecting current and future prospects of coal-fired generation. The executives are Tim Curran, head of Alstom Power for the USA and Senior Vice President and General Manager of Boilers North America; Ray Kowalik, President and General Manager of Burns and McDonnell Energy Group; Jeff Holmstead, head of Environmental Strategies for the Bracewell Giuliani law firm; Jim Mackey, Vice President, Fluor Power Group's Solid Fuel business line; Tom Shelby, President Kiewit Power Inc., and David Wilks, President of Energy Supply for Excel Energy Group. Steve Blankinship, the magazine's Associate Editor, was the moderator. 6 photos.

20 FOSSIL-FUELED POWER PLANTS↗

Influence of the down-draft secondary air on the furnace aerodynamic characteristics of a down-fired boiler

The operation of down-fired boilers can suffer from problems of high carbon content in the fly ash. This is because horizontally fed secondary air keeps the fuel-rich flow from going deep down into the lower furnace and the recirculation zones in the furnace hopper area are too large. To improve the burnout of coal in down-fired boilers, a retrofit modification was devised and validated. The modification lowered the angle of flow of the secondary air to a down-draft. Experiments were carried out on a single-phase test facility to investigate the influence of down-draft secondary air on the aerodynamic field in the furnace. The depth reached by the fuel-rich flow in the down-furnace, the volume of dead recirculation zone, the angle of the mixed air in the airflow zone of secondary air, and the turbulence intensity in certain cross sections were investigated. The results show when the flow of secondary air was lowered to an optimized angle, the primary air can reach a deeper position in the lower furnace without washing the furnace hopper, and consequently the dead recirculation zone shrinks. The influence of the secondary air ratio distribution on the flow field was also investigated. 6 refs., 13 figs., 5 tabs.

01 COAL, LIGNITE, AND PEAT↗

Radiological Impact Associated to Technologically Enhanced Naturally Occurring Radioactive Materials (TENORM) from Coal-Fired Power Plants Emissions - 13436

Certain materials used and produced in a wide range of non-nuclear industries contain enhanced activity concentrations of natural radionuclides. In particular, electricity production from coal is one of the major sources of increased human exposure to naturally occurring radioactive materials. A methodology was developed to assess the radiological impact due to natural radiation background. The developed research was applied to a specific case study, the Sines coal-fired power plant, located in the southwest coastline of Portugal. Gamma radiation measurements were carried out with two different instruments: a sodium iodide scintillation detector counter (SPP2 NF, Saphymo) and a gamma ray spectrometer with energy discrimination (Falcon 5000, Canberra). Two circular survey areas were defined within 20 km of the power plant. Forty relevant measurements points were established within the sampling area: 15 urban and 25 suburban locations. Additionally, ten more measurements points were defined, mostly at the 20-km area. The registered gamma radiation varies from 20 to 98.33 counts per seconds (c.p.s.) corresponding to an external gamma exposure rate variable between 87.70 and 431.19 nGy/h. The highest values were measured at locations near the power plant and those located in an area within the 6 and 20 km from the stacks. In situ gamma radiation measurements with energy discrimination identified natural emitting nuclides as well as their decay products (Pb-212, Pb-2142, Ra-226, Th-232, Ac-228, Th-234, Pa-234, U- 235, etc.). According to the results, an influence from the stacks emissions has been identified both qualitatively and quantitatively. The developed methodology accomplished the lack of data in what concerns to radiation rate in the vicinity of Sines coal-fired power plant and consequently the resulting exposure to the nearby population. (authors)

54 ENVIRONMENTAL SCIENCES↗

Revenue Opportunities through Ancillary Services for Nuclear Power Plants with Integrated Firebrick Resistance- Heated Energy Storage (FIRES)

Deregulation of electricity markets has brought about major changes in the ways investments in and operation of power plants are planned and optimized. Although many NPPs have seen reduced revenue in recent years as power purchase agreement end and wholesale market electricity prices have remained low, there are opportunities to expand the technical capabilities of NPPs, participate in additional market services and increase revenue. This transaction summarizes the opportunities provided by participation in ancillary services markets potentially made possible by integration of thermal energy storage capacity, specifically the Firebrick Resistance-heated Energy Storage System (FIRES), into future nuclear power plants with high-temperature reactors and Nuclear Air-Brayton combined cycle (NACC) power conversion. The restructuring, or deregulation, of electric power systems in most of Europe and North America has had a substantial impact on the economic performance of currently operating nuclear power plants (NPPs) and the prospects for new builds. Owners of NPPs in some markets have expressed concern that low wholesale electricity market prices and insufficient compensation for capacity, reliability, and other services are threatening the financial viability of their plants. However, both current and future NPPs have the potential to increase their competitiveness by increasing the flexibility of their electricity output. Flexible output has previously only been possible in water-cooled reactors through load-following operation, which requires core power maneuvers and operation of the steam turbine at reduced efficiency. Integration of thermal energy storage systems (TESS) provides an alternative, providing the plant the option to either output electricity or store heat for greater later electric output. The plant owner may thus increase sales of electricity during hours when it is most valuable. Even more, some TESS technologies have the potential to greatly increase the net ramp rate capability of the plant. The ability to rapidly change net power output to the grid may make it possible for NPPs to secure additional revenue by providing additional minute-by-minute balancing services to the grid. FIRES is only one technology out of many that might provide additional technical capabilities at NPPs, and this discussion has only highlighted the opportunities in a single market. Analysis of other options, include steam accumulator systems, nitrate salt TESS, phase change material TESS, and opportunities in other markets are subjects of ongoing work. Deregulation of electricity markets has brought about major changes in the ways investments in and operation of power plants are planned and optimized. Although many NPPs have seen reduced revenue in recent years as power purchase agreements end and wholesale market electricity prices have remained low, there are opportunities to expand the technical capabilities of NPPs, participate in additional market services, and increase revenue. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗