Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLAT PLATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Development of a three-dimensional Navier-Stokes code on CDC star-100 computer

A three-dimensional code in body-fitted coordinates was developed using MacCormack's algorithm. The code is structured to be compatible with any general configuration, provided that the metric coefficients for the transformation are available. The governing equations are developed in primitive variables in order to facilitate the incorporation of physical boundary conditions and turbulence-closure models. MacCormack's two-step, unsplit, time-marching algorithm is used to solve the unsteady Navier-Stokes equations until steady-state solution is achieved. Cases discussed include (1) flat plate in supersonic free stream; (2) supersonic flow along an axial corner; (3) subsonic flow in an axial corner at M infinity = 0.95; and (4) supersonic flow in an axial corner at M infinity 1.5.

Vatsa, V. N.↗

Thermal performance evaluation of the Calmac (liquid) solar collector

The procedures used and the results obtained during the evaluation test program on the S. N. 1, (liquid) solar collector are presented. The flat plate collector uses water as the working fluid. The absorber plate is aluminum with plastic tubes coated with urethane black. The glazing consists of .040 in fiberglass reinforced polyester. The collector weight is 78.5 pounds with overall external dimensions of approximately 50.3in. x 98.3in. x 3.8in. The following information is given: thermal performance data under simulated conditions, structural behavior under static loading, and the effects of long term exposure to natural weathering. These tests were conducted using the MSFC Solar Simulator.

Usher, H.↗

Development of Surfaces Optically Suitable for Flat Solar Panels

Three areas of research in the development of flat solar panels are described. (1) A reflectometer which can separately evaluate the spectral and diffuse reflectivities of surfaces was developed. The reflectometer has a phase locked detection system. (2) A coating composed of strongly bound copper oxide that is formed by an etching process performed on an aluminum alloy with high copper content was also developed. Because of this one step fabrication process, fabrication costs are expected to be small. (3) A literature search was conducted and conclusions on the required optical properties of flat plate solar collectors are presented.

Desmet, D.↗

Pressure and velocity measurements in a three dimensional wall jet

A flat plate and a curved wall surface, intended to model a wing-flap combination in a high V/STOL configuration, were used to measure pressure and flow velocity in a freely expanding coflowing jet and a three dimensional wall jet. The effects of increasing the velocity ratio of the jet exit plane velocity to the free stream velocity were investigated. Velocity measurements were made using a two color laser Doppler velocimeter with a phase-locked loop processor. Fluctuating pressures were monitored with condenser-type microphones. Quantities measured include the width of the mixing region, the mean velocity field, turbulent intensities, and time scales. Wall and static pressure-velocity correlations and coherences are presented.

Catalano, G. D.↗

Lifetime and diffusion length measurements on silicon material and solar cells

Experimental methods were evaluated for the determination of lifetime and diffusion length in silicon intentionally doped with potentially lifetime-degrading impurities found in metallurgical grade silicon, impurities which may be residual in low-cost silicon intended for use in terrestrial flat-plate arrays. Lifetime measurements were made using a steady-state photoconductivity method. Diffusion length determinations were made using short-circuit current measurements under penetrating illumination. Mutual consistency among all experimental methods was verified, but steady-state photoconductivity was found preferable to photoconductivity decay at short lifetimes and in the presence of traps. The effects of a number of impurities on lifetime in bulk material, and on diffusion length in cells fabricated from this material, were determined. Results are compared with those obtained using different techniques. General agreement was found in terms of the hierarchy of impurities which degrade the lifetime.

Othmer, S.↗

Description and preliminary calibration results for the Langley hypersonic CF4 tunnel

A detailed description of the hypersonic CF4 tunnel is presented along with discussion of the basic components, instrumentation, and operating procedure. Operational experience with the CF4 reclaimer and lead-bath heater is discussed. Comparison of measured and predicted shock detachment distance on a sphere and pressure distributions measured on a sharp leading-edge flat plate revealed the absence of significant flow nonuniformity and lent creditability to predicted free stream flow conditions. The economic operation of this facility centers about the CF4 reclaimer, which was designed to operate at an efficiency of 90 to 95 percent. A number of modifications were made to the reclaimer system to improve its performance, and presently, the system reclaims approximately 75 percent of the test gas. Even with current budgetary constraints, this efficiency permits the CF4 tunnel to be operated as a viable research wind tunnel.

Midden, R. E.↗

Long-term weathering effects on the thermal performance of the Lennox/Honeywell (liquid) solar collector

The test procedures used and the results obtained during the evaluation test program of the Lennox/Honeywell double covered liquid solar collector. The tests were performed under simulated conditions, following long-term exposure to natural weathering conditions. The Lennox/Honeywell collector is a flat-plate solar collector. The absorber plate is steel with copper tubes bonded on the upper surface, and is coated with black chrome. Visual inspection of the collector indicated slight discoloration of the absorber plate. Results indicate that performance degradation had occurred. Absorptivity and/or transmissivity decreased as a result of the weathering.

Source record↗

Libbey-Owens-Ford solar collector static load test

The test article is a flat plate solar collector that uses liquid as the heat transfer medium. The absorber plate is copper and has a double tempered glass cover. Test requirements and procedures are described and results are presented in a table. Results demonstrate that the collector performed satisfactorily.

Source record↗

LARGO hot water system thermal performance test report

The thermal performance tests and results on the LARGO Solar Hot Water System under natural environmental conditions is presented. Some objectives of these evaluations are to determine the amount of energy collected, the amount of energy delivered to the household as contributed by solar power supplied to operate the system and auxiliary power to maintain tank temperature at proper level, overall system efficiency and to determine temperature distribution within the tank. The Solar Hot Water system is termed a Dump-type because of the draining system for freeze protection. The solar collector is a single glazed flat plate. An 82-gallon domestic water heater is provided as the energy storage vessel. Water is circulated through the collector and water heater by a 5.3 GPM capacity pump, and control of the pump motor is achieved by a differential temperature controller.

Source record↗

Exploratory investigation of the effect of porous surfaces on hypersonic turbulent boundary layers

Four different test surfaces were studied to determine the effect of porous walls on the characteristics of a hypersonic turbulent flat-plate boundary layer. The investigation was an attempt to decrease the surface shear of the boundary layer by transmitting fluctuating pressure energy through the wall and absorbing it in a cavity beneath the wall. Pitot surveys were made at two locations, schlieren photographs of the boundary layer were taken, and hot-wire measurements in the flow above the boundary layer were made to determine whether the surfaces affected the turbulent boundary layer. Neither an increase nor a decrease in surface shear or boundary-layer growth was detected. Tabulations of the pitot data are included.

Watson, R. D.↗

Thermal performance evaluation of the Solargenics solar collector at outdoor conditions

Test procedures used during the performance of an evaluation program are presented. The test program was conducted to obtain the following performance data and information on the solar collector. (1) thermal performance data under outdoor conditions; (2) structural behavior of collector under static conditions; (3) effects of long term exposure to material weathering elements. The solargenics is a liquid, single-glazed, flat plate collector. Approximate dimensions of each collector are 240 inches long, 36 inches wide, and 3.5 inches in depth.

Source record↗

Solar hot water system installed at Anderson, South Carolina

A description is given of the solar energy hot water system installed in the Days Inns of America, Inc., at Anderson, South Carolina. The building is a low-rise, two-story 114-room motel. The solar system was designed to provide 40 percent of the total hot water demand. The collector is a flat plate, liquid with an area of 750 square feet. Operation of this system was begun in November 1977, and has performed flawlessly for one year.

Source record↗

Solar heating and hot water system installed at Listerhill, Alabama

The Solar system was installed into a new building and was designed to provide 79% of the estimated annual space heating load and 59% of the estimated annual potable hot water requirement. The collectors are flat plate, liquid manufactured by Reynolds Metals Company and cover a total area of 2344 square feet. The storage medium is water inhibited with NALCO 2755 and the container is an underground, unpressurized steel tank with a capacity of 5000 gallons. This report describes in considerable detail the solar heating facility and contains detailed drawings of the completed system.

Source record↗

System Design Package for SIMS Prototype System 3, Solar Heating and Domestic Hot Water

A collation of documents and drawings are presented that describe a prototype solar heating and hot water system using liquid flat plate collectors and a gas or electric furnace energy subsystem. The system was designed for installation into a single-family dwelling. The description, performance specification, subsystem drawings, verification plan/procedure, and hazard analysis of the system are packaged for evaluation of the system with information sufficient to assemble a similar system.

Source record↗

Analysis and Experimental Tests of a High-Performance Evacuated Tubular Collector

A high-performance collector based on the use of all-glass, evacuated tubular collector elements is described and analyzed, and supporting experimental data presented. The collector operated with excellent efficiency at temperatures high enough to drive existing air conditioning units, and showed good performance under diffuse light and low insolation conditions. Collector efficiency was insensitive to operating temperature, ambient temperature, and wind speed. In addition, air, as well as liquid, can be used as the heat transfer fluid, with no significant performance penalty. While the equations governing the useful energy produced can be cast in a form similar to that for flat plate collectors, several important parameters were unique in a number of respects. The loss coefficient was unusually low, while the flow factor and effective insolation were unusually high.

Beekley, D. C.↗

Long term weathering effects on the thermal performance of the sunworks (liquid) solar collector

The test procedures used and the results obtained during the evaluation test program of the Sunworks single-covered liquid solar collector are presented. The tests were performed under simulated conditions, following long-term exposure to natural weathering conditions. The sunworks collector is a flat-plate solar collector. The absorber plate is copper with copper tubes bonded by soft solder, and is coated with Enthon selective black with an absorptivity factor of .87 similar to .92 and an emissivity factor of .10 similar to .20. It has a single glass cover of 3/16 inches tempered glass and weighs about 115 pounds. The overall dimensions of the collector are 36 x 84 x 4 inches.

Source record↗

Nonlinear interaction of waves in boundary-layer flows

First-order nonlinear interactions of Tollmien-Schlichting waves of different frequencies and initial amplitudes in boundary-layer flows are analyzed by using the method of multiple scales. For the case of two waves, a strong nonlinear interaction exists if one of the frequencies w2 is twice the other frequency w1. Numerical results for flow past a flat plate show that this interaction mechanism is strongly destabilizing even in regions where either the fundamental or its harmonic is damped in the absence of the interaction. For the case of three waves, a strong nonlinear interaction exists when w3 = w2- w1. This combination resonance causes the amplitude of the wave with the difference frequency w3 to multiply many times in magnitude in a short distance even if it is damped in the absence of the interaction. The initial amplitudes play a dominant role in determining the changes in the amplitudes of the waves in both of these mechanisms.

Nayfeh, A. H.↗

Pressure and thermal distributions on wings and adjacent surfaces induced by elevon deflections at Mach 6

Surface pressure distributions and heat transfer distributions were obtained on wing half-models in regions where three dimensional separated flow effects are prominent. Unswept and 50 deg and 70 deg swept semispan wings were tested, for trailing-edge-elevon ramp angles of 0 deg, 10 deg, 20 deg, and 30 deg, with and without cylindrical and flat plate center bodies and with and without various wing-tip plates and fins. The data, obtained for a free stream Mach number of 6 and a wing-root-chord Reynolds number of 18.5 million, reveal considerably larger regions of increased pressure and thermal loads than would be anticipated using non-separated flow analyses.

Kaufman, L. G., II↗