Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FIGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

CONSOL Energy invests in West Virginia CTL plant

Working with Synthesis Energy Systems (SES), America's leading bituminous coal producer assists with the engineering design package for a coal gasification and liquefaction plant to be located near Benwood in West Virginia. Coal will be converted to syngas using SES's proprietary U-GAS technology. The syngas is expected to be used to produce about 720,000 metric tons per year of methanol. The U-GAS technology is licensed from the Gas Technology Institute (GTI). The article explains how the GTI gasification process works. It is based on a surge-stage fluidised bed for production of low-to-medium calorific value synthesis gas from a variety of feedstocks, including coal. 2 figs.

01 COAL, LIGNITE, AND PEAT↗

Vendors boot up a new generation of mining software

From complete mine management down to the smallest detail of process or machine design, the latest programs are claimed to process and display data easier, faster, and more accurately. MINExpo 2008 held in Las Vegas in September offered a bonanza of information on complete mine management to specilaized financial modules. Gemcom Software introduced new versions of five of its key products - Surpac 6.1, GEMS 6.2, Minex 5.3, MinerSched 6.0 and Whittle 4.2. Lerca Geosystems launched its Jigsaw 360 mine management suite, encompassing GPS navigation. Products launched by Modular Mining systems, Carlson Software, DEM Solutions and Logimine are also mentioned. 2 figs.

01 COAL, LIGNITE, AND PEAT↗

Hearing protection for miners

A NIOSH analysis showed that at age 50 approximately 90% of coal miners have a hearing impairment, yet noise included hearing loss is 100% preventable. The article discusses requirements of the MSHA regulations, 30 CFR Part 62 - occupational noise exposure (2000) and a 2008-MSHA document describing technologically achievable and promising controls for several types of mining machinery. Hearing protection is still required for exposure to greater than 90 dBA. These are now commercially available ways to determine how much attenuation an individual gets from a given hearing protector, known as 'fit testing'. 3 refs., 1 fig., 1 tab., 1 photo.

01 COAL, LIGNITE, AND PEAT↗

Whistling in the dark - inside South Africa's power crisis

State-owned Eskom has a near-monopoly on power generation in South Africa. Though one might think government control would make the business of managing power supplies easier, the story of Eskom's recent troubles shows that state ownership, in and of itself, is neither the problem nor the solution. More important than ownership structure are policy and planning decisions that take the long view. Eskom's cautionary tale should remind those involved in the power industry anywhere in the world that, to vary a disclosure from the financial sector that too few have paid attention to, past performance is not a guarantee of future success. 8 figs.

20 FOSSIL-FUELED POWER PLANTS↗

Extraction of weakly reductive and reductive coals with sub- and supercritical water

On a semi-continuous apparatus, a weakly reductive Shenfu-Dongsheng (SD) coal and a reductive Pingshuo (PS) coal were non-isothermally extracted with sub- and supercritical water to explore the differences between the two coals. The effect of the temperature on the extract formation rate, conversion, and product composition under different pressures was investigated. The extraction results of two coal samples indicate that the extract formation rate has a maximum in the studied temperature range between room temperature and 500{degree}C. The temperature corresponding to the maximum extract formation rate, changing with the pressure, is between 390 and 410{degree}C. The gas yield, extract yield, and conversion of two coals increase with the increasing pressure. In comparison to PS coal, SD coal has a low temperature corresponding to the maximum extract formation rate under the same pressure. Both coals have a main fraction of asphaltene, but SD coal has a higher fraction of oil than PS coal. The main gas components are CO{sub 2}, CH{sub 4}, and H{sub 2}. The gas from PS coal has a higher CH{sub 4} content and lower CO{sub 2} content than that from SD coal. The analysis results of the extraction residue indicated that SD coal has a low residue yield and the residue shows a large surface area and small average pore diameter compared to PS coal. 17 refs., 4 figs., 8 tabs.

01 COAL, LIGNITE, AND PEAT↗

Differences in gasification behaviors and related properties between entrained gasifier fly ash and coal char

In the study, two fly ash samples from Texaco gasifiers were compared to coal char and the physical and chemical properties and reactivity of samples were investigated by scanning electron microscopy (SEM), SEM-energy-dispersive spectrometry (EDS), X-ray diffraction (XRD), N{sub 2} and CO{sub 2} adsorption method, and isothermal thermogravimetric analysis. The main results were obtained. The carbon content of gasified fly ashes exhibited 31-37%, which was less than the carbon content of 58-59% in the feed coal. The fly ashes exhibited higher Brunauer-Emmett-Teller (BET) surface area, richer meso- and micropores, more disordered carbon crystalline structure, and better CO{sub 2} gasification reactivity than coal char. Ashes in fly ashes occurred to agglomerate into larger spherical grains, while those in coal char do not agglomerate. The minerals in fly ashes, especial alkali and alkaline-earth metals, had a catalytic effect on gasification reactivity of fly ash carbon. In the low-temperature range, the gasification process of fly ashes is mainly in chemical control, while in the high-temperature range, it is mainly in gas diffusion control, which was similar to coal char. In addition, the carbon in fly ashes was partially gasified and activated by water vapor and exhibited higher BET surface area and better gasification activity. Consequently, the fact that these carbons in fly ashes from entrained flow gasifiers are reclaimed and reused will be considered to be feasible. 15 refs., 7 figs., 5 tabs.

01 COAL, LIGNITE, AND PEAT↗

Changes in char structure during the gasification of a Victorian brown coal in steam and oxygen at 800{degree}C

Char structure is an important factor influencing its reactivity during gasification. This study aims to investigate the changes in char structure during the gasification of brown coal. A Victorian brown coal was gasified in a fluidized-bed/fixed-bed reactor at 800{degree}C in atmospheres containing 15% H{sub 2}O, 2000 ppm O{sub 2}, or 15% H{sub 2}O and 2000 ppm O{sub 2}, respectively. Although the char gasification in 2000 ppm O{sub 2} was mainly rate-limited by the external diffusion of O{sub 2}, the char-H{sub 2}O reaction was mainly rate-limited by the chemical reactions. The structural features of char at different levels of char gasification conversion were examined with FT-Raman spectroscopy. Our results show that the chars from the gasification in the mixture of 2000 ppm O{sub 2} and 15% H{sub 2}O had almost the same features as the chars from the gasification in 15% H{sub 2}O alone when the same levels of char conversion were achieved. Both the thermal decomposition of char and the char gasification reactions could result in changes in char structure during gasification. 29 refs., 5 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Black gold: return of the king

The coal industry has woken from its slumber and finds itself ill-prepared for the demands being made upon it. Exporters are proving slow to expand their capacities and overcome infrastructural bottlenecks. The financial crisis may cause a hiatus in demand growth, but it will also limit finance for investment. 3 figs.

01 COAL, LIGNITE, AND PEAT↗

Natural mercury isotope variation in coal deposits and organic soils

There is a need to distinguish among sources of Hg to the atmosphere in order to more fully understand global Hg pollution. In this study we investigate whether coal deposits within the United States, China, and Russia-Kazakhstan, which are three of the five greatest coal-producing regions, have diagnostic Hg isotopic fingerprints that can be used to discriminate among Hg sources. We also investigate the Hg isotopic composition of modern organic soil horizons developed in areas distant from point sources of Hg in North America. Mercury stored in coal deposits displays a wide range of both mass dependent fractionation and mass independent fractionation. {delta}{sup 202}Hg varies in coals by 3{per_thousand} and {Delta}{sup 201}Hg varies by 0.9{per_thousand}. Combining these two Hg isotope signals results in what may be a unique isotopic 'fingerprint' for many coal deposits. Mass independent fractionation of mercury has been demonstrated to occur during photochemical reactions of mercury. This suggests that Hg found in most coal deposits was subjected to photochemical reduction near the Earth's surface prior to deposition. The similarity in MDF and MIF of modern organic soils and coals from North America suggests that Hg deposition from coal may have imprinted an isotopic signature on soils. This research offers a new tool for characterizing mercury inputs from natural and anthropogenic sources to the atmosphere and provides new insights into the geochemistry of mercury in coal and soils. 35 refs., 2 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Indonesian coal mining

The article examines the opportunities and challenges facing the Indonesian coal mining industry and how the coal producers, government and wider Indonesian society are working to overcome them. 2 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

The formation and emission of particulate matter during the combustion of density separated coal fractions

A Chinese bituminous coal was separated into three density fractions using the float-sink method: heavy , medium and light Combustion and pyrolysis ofcoal with different density fractions were carried out in a laboratory-scale drop tube furnace to understand the formation mechanism of inhalable particulate matter, PM10 and PM1. The results indicated that the light fraction of the coal produced 44 wt % of total PM10 and 45 wt % of total PM1. The medium fraction of the coal contributed 52 wt % of total PM10 and 49 wt % of total PM1. The heavy fraction contributed 4 wt % of total PM10 and 6 wt % of total PM1. The light fraction and the medium fraction of the coal contained mostly included mineral and the heavy fraction contained largely excluded minerals. The PM10 and PM1 contents formed by the excluded minerals were very low compared to those formed primarily from included minerals. The proportion of the minerals in the light density fraction converted into PM1 and PM10 was the highest, with their weight percentages being 9.59% and 43.49%, respectively. One reason for this was the mineral particle size. The median mineral size in the light density fraction coal was smallest. Another reason was mineral transformation during combustion. The light fraction and the medium fraction of the coal contained mostly included minerals, and the heavy fraction contained largely excluded minerals. The transformations of included and excluded minerals were largely different and played a different role during coal combustion. The last reason was char fragmentation. Char formed by the light coal fraction was easier to fragment and subsequently formed more fine ash particles. This was because the swelling ratio, BET surface area, and total pore volume of char decreased with increasing parent coal density. 37 refs., 10 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

Occurrence and fate of some trace elements during pyrolysis of Yima coal, China

Modes of occurrence and transformation behaviors of selected trace elements during coal pyrolysis were studied. The element content in coal and chars was determined by inductively coupled plasma-mass spectrometry (ICP-MS). The elemental occurrence in raw coal was analyzed through a sequential extraction procedure and determined by inductively coupled plasma-atomic absorption spectroscopy (ICP-AAS). The trace elements in Yima coal are separated into five fractions: water soluble, ion exchangeable, carbonate, organic material, and residue. All the elements studied mainly exist in the residue fraction. With regard to heavy-metal elements studied, the residue fraction takes about 50-80% and the organic fraction takes about 15-40%; other chemical forms occurred at a very low level. Only Mn and Ni showed a sizable distribution of water-soluble, ion-exchangeable, and carbonate fraction. During coal pyrolysis, part of the element became released from the coal body and some other parts became enriched in chars. All the elements showed a increasing release ratio with the temperature ascending; at the same pyrolysis temperature, the release ratio of heavy-metal elements is higher than that of the rare earth elements (REEs). At 900{degree}C, the volatilizable fraction of the coal body is nearly depleted, the pyrolysis almost came to an end and the release intensity was approaching zero. All the elements showed a enrichment in chars and the enrichment ratioincreases with the temperature ascending. The modes of occurrence of the element is a key role affecting the transformation during pyrolysis. With regard to REEs, there is a negative correlation between the elements left in chars and the residue fraction in raw coal, indicatingthat the element content left in chars for REEs is a result of the element distribution in the residue fraction in raw coal. 26 refs., 7 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

Challenges for Lithuania: Ignalina NPP Early Closure

As a condition of accession into the European Union (EU), Lithuania is committed to the closure and decommissioning of Ignalina NPP comprising two RBMK-1500 reactor units (Fig. 1). It was agreed in a special protocol to the Accession Treaty that, in return for adequate EU financial assistance, Unit 1 would be closed before 2005 and Unit 2 by the end of 2009. The first unit was duly shut down on December 31, 2004. Lithuania, which has borders with Russia (Kaliningrad territory), Poland, Latvia and Belarus, spent fifty years as part of the Soviet Union and was deeply integrated into its economy and electrical infrastructure. At the break-up of the USSR, Lithuania inherited electricity generating capacity designed to supply the north-west region including ownership of Ignalina NPP located in the north-east of the country. Ignalina NPP Unit 1 was commissioned in 1983, Unit 2 in 1987; the planned lifespan of each unit was 30 years. Construction of a third unit was started but never completed. Since Lithuania became independent in 1990, Ignalina NPP has typically contributed more than 70% of national power supply. The town of Visaginas (population approx. 30,000) was purpose built to serve the plant and staff were brought in from throughout the USSR. With 3200 direct employees, Ignalina NPP remains by far the largest employer. Although there are pockets of Russian-language speakers in communities throughout Lithuania, Visaginas is the only example on a whole-town scale. Thus closure of Ignalina NPP within the restricted timescale required by the EU Accession Treaty commitment set an exceptional challenge to Lithuania. However, since the preparatory phase of decommissioning started in 2000, notable progress has been made, experience gained and lessons learnt. At present Unit 1 remains partially fueled in a state of care and maintenance. Partly burnt fuel is being transferred from Unit 1 to Unit 2 for further irradiation in order to minimize the commitment of new fuel thereby reducing operating costs and the final quantity of spent fuel. Design and construction of the facilities for spent fuel storage, waste processing and free-release is ongoing. The siting of the Near Surface Repository is now in the final stages of approval and construction of the landfill facility is under tendering. In order to facilitate the approval process and minimize the transport of waste, both disposal facilities will be within the boundary of the NPP site. Approximately 450 staff are employed at the shutdown Unit 1 for the safe maintenance of essential systems. The total staffing level at the plant is currently being reduced by around 200 each year, with a larger release to take place at the closure of Unit 2. It is envisaged that 2000 staff will be required for the dismantling operations. Although Ignalina NPP is still in the early stages of closure and decommissioning, some important lessons have already been learnt: Firstly, the importance considering social and financial issues as well as technical factors in deciding the decommissioning strategy. This should be done before the preparation is started of the FDP. The same broad consideration should also be given to the economic restructuring of the local area. Consultation is necessary with local and national authorities, and other stakeholders up to ensure a common vision. At Ignalina NPP it was considered essential to staff morale and the maintenance of a strong safety culture to guarantee the special social and employment benefits to dismissed staff in law [9]. At the same time, measures were also adopted to encourage certain key personnel to remain at the plant until closure. The case of Lithuania, which at independence had no legislative framework or management infrastructure for radioactive waste, may be exceptional; however, for all decommissioning projects it is necessary to have, from the outset, a clear strategy on waste storage and disposal. Finally, coordination at all levels must be assured, especially with the involvement of the nuclear regulators and other regulatory authorities, to achieve a smooth progression from operation into decommissioning.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Roof bolting improvements

Suppliers partner with mine operators to offer safer, more productive tools for roof bolting. 4 figs.

01 COAL, LIGNITE, AND PEAT↗

Mercury emissions during cofiring of sub-bituminous coal and biomass (chicken waste, wood, coffee residue, and tobacco stalk) in a laboratory-scale fluidized bed combustor

Four types of biomass (chicken waste, wood pellets, coffee residue, and tobacco stalks) were cofired at 30 wt % with a U.S. sub-bituminous coal (Powder River Basin Coal) in a laboratory-scale fluidized bed combustor. A cyclone, followed by a quartz filter, was used for fly ash removal during tests. The temperatures of the cyclone and filter were controlled at 250 and 150{sup o}C, respectively. Mercury speciation and emissions during cofiring were investigated using a semicontinuous mercury monitor, which was certified using ASTM standard Ontario Hydra Method. Test results indicated mercury emissions were strongly correlative to the gaseous chlorine concentrations, but not necessarily correlative to the chlorine contents in cofiring fuels. Mercury emissions could be reduced by 35% during firing of sub-bituminous coal using only a quartz filter. Cofiring high-chlorine fuel, such as chicken waste (Cl = 22340 wppm), could largely reduce mercury emissions by over 80%. When low-chlorine biomass, such as wood pellets (Cl = 132 wppm) and coffee residue (Cl = 134 wppm), is cofired, mercury emissions could only be reduced by about 50%. Cofiring tobacco stalks with higher chlorine content (Cl = 4237 wppm) did not significantly reduce mercury emissions. Gaseous speciated mercury in flue gas after a quartz filter indicated the occurrence of about 50% of total gaseous mercury to be the elemental mercury for cofiring chicken waste, but occurrence of above 90% of the elemental mercury for all other cases. Both the higher content of alkali metal oxides or alkali earth metal oxides in tested biomass and the occurrence of temperatures lower than 650{sup o}C in the upper part of the fluidized bed combustor seemed to be responsible for the reduction of gaseous chlorine and, consequently, limited mercury emissions reduction during cofiring. 36 refs., 3 figs. 1 tab.

01 COAL, LIGNITE, AND PEAT↗

New laser technology helps reduce coal-slagging headaches

Laser-induced breakdown spectroscopy (LIBS) is starting to light the way for power plant operators who want to reduce coal ash deposition in their boilers. The method was developed by Lehigh University's Energy Research Centre and the Energy Research Co. The LIBS system analyzes the chemical properties of coal using a pulsating laser with two frequencies, one infrared and one visible light. The laser vaporizes a sample, resulting in a distinct elemental signature. From these data, a newly developed software package containing artificial neural network (ANN) models estimates ash fusion temperature and predicts coal slagging potential. LIBS is the size of a table top, safe to use and provides instantaneous data without interrupting the process. The performance of the LIBS system was verified in lab experiments and then the system was set up at Dominion's Brayton Point Power Station, a 1,150-MW coal-fired power plant in Somerset, MA. The project demonstrated the merit of the LIBS system that produces coal elemental analysis and estimated fusion temperatures. Further development is needed to equip a LIBS system with an automatic online coal-sampling attachment and to achieve higher accuracy and repeatability. The researchers have been awarded a second DOE grant to fund development of a commercial prototype of the LIBS system. 2 figs., 2 photos.

01 COAL, LIGNITE, AND PEAT↗

Predictable SCR co-benefits for mercury control

A test program, performed in cooperation with Dominion Power and the Babcock and Wilcox Co., was executed at Dominion Power's Mount Storm power plant in Grant County, W. Va. The program was focused on both the selective catalytic reduction (SCR) catalyst capability to oxide mercury as well as the scrubber's capability to capture and retain the oxidized mercury. This article focuses on the SCR catalyst performance aspects. The Mount Storm site consists of three units totaling approximately 1,660 MW. All units are equipped with SCR systems for NOx control. A full-scale test to evaluate the effect of the SCR was performed on Unit 2, a 550 MWT-fired boiler firing a medium sulfur bituminous coal. This test program demonstrated that the presence of an SCR catalyst can significantly affect the mercury speciation profile. Observation showed that in the absence of an SCR catalyst, the extent of oxidation of element a mercury at the inlet of the flue gas desulfurization system was about 64%. The presence of a Cornertech SCR catalyst improved this oxidation to levels greater than 95% almost all of which was captured by the downstream wet FGD system. Cornertech's proprietary SCR Hg oxidation model was used to accurately predict the field results. 1 ref., 2 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Demonstration of integrated optimization software

NeuCO has designed and demonstrated the integration of five system control modules using its proprietary ProcessLink{reg_sign} technology of neural networks, advanced algorithms and fuzzy logic to maximize performance of coal-fired plants. The separate modules control cyclone combustion, sootblowing, SCR operations, performance and equipment maintenance. ProcessLink{reg_sign} provides overall plant-level integration of controls responsive to plant operator and corporate criteria. Benefits of an integrated approach include NOx reduction improvement in heat rate, availability, efficiency and reliability; extension of SCR catalyst life; and reduced consumption of ammonia. All translate into cost savings. As plant complexity increases through retrofit, repowering or other plant modifications, this integrated process optimization approach will be an important tool for plant operators. 1 fig., 1 photo.

01 COAL, LIGNITE, AND PEAT↗