Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FEET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Silicon Ingot Casting: Heat Exchanger Method. Multi-wire Slicing: Fixed Abrasine Slicing Technique, Phase 3

Ingot casting was scaled up to 16 cm by 16 cm square cross section size and ingots weighing up to 8.1 kg were cast. The high degree of crystallinity was maintained in the large ingot. For large sizes, the nonuniformity of heat treatment causes chipping of the surface of the ingot. Progress was made in the development of a uniform graded structure in the silica crucibles. The high speed slicer blade-head weight was reduced to 37 pounds, allowing surface speeds of up to 500 feet per minute. Slicing of 10 cm diameter workpieces at these speeds increased the through-put of the machine to 0.145 mm/min.

Schmid, F.↗

Wind turbine generator application places unique demands on tower design and materials

The most relevant contractual tower design requirements and goal for the Mod-1 tower are related to steel truss tower construction, cost-effective state-of-the-art design, a design life of 30 years, and maximum wind conditions of 120 mph at 30 feet elevation. The Mod-1 tower design approach was an iterative process. Static design loads were calculated and member sizes and overall geometry chosen with the use of finite element computer techniques. Initial tower dynamic characteristics were then combined with the dynamic properties of the other wind turbine components, and a series of complex dynamic computer programs were run to establish a dynamic load set and then a second tower design.

Kita, J. P.↗

Potential applications of a high altitude powered platform in the ocean/coastal zone community

The results of a survey of the ocean/coastal zone community conducted for the NASA Wallops Flight Center to identify potential applications of a high altitude powered platform (HAPP) are presented. Such a platform would stationkeep at 70,000 feet for up to a year over a given location and make frequent high resolution observations, or serve as a regional communications link. The survey results indicate user interest among scientific researchers, operational agencies and private industry. It is felt that such a platform would combine the desirable characteristics of both geostationary satellites (wide area, frequent observation) and aircraft (high resolution). As a result a concept for an operational HAPP system in the form of a 'mesoscale geostationary satellite' system evolved. Such a system could employ many of the same technologies used in current NASA and NOAA geostationary satellite programs. A set of generalized instrument requirements for HAPP borne sensors is also presented.

Escoe, D.↗

XV-15 flight test results compared with design goals

Aircraft No. 2 is presently in the midst of flight envelope expansion. Noise and safety design goals have been demonstrated; preliminary results indicate that performance and component life goals may also be met. Hovering power indicates a standard hover ceiling of 7,000 feet. After 18.0 hours of flight, a true airspeed of 207 knots has been reached. The goal is a 300-knot cruise speed. So far, XV-15 flight tests indicate no reason why the tilt rotor concept should not fulfill its promise to provide a major step forward in air vehicle flexibility and in rotary wing performance.

Wernicke, K. G.↗

An interpretation of the polarization of microwave bursts

High-spatial-resolution (a few seconds of arc) observations of microwave bursts have demonstrated that only the impulsive phase of the burst is polarized; one observes only one polarity in the burst source if it is weak (Alissandrakis and Kundu) and both polarities if it is intense (Enome et al.). These results are interpreted in terms of an asymmetrical bipolar field structure of the loop in which the energetic electrons responsible for the radiation are contained. The role of unequal field strengths at the feet of the loop on the number of electrons trapped and their pitch angle distribution are discussed in a specific model. Computations of the polarized intensity originating from each foot of the loop seem to be consistent with the observations at present available.

Kundu, M. R.↗

Safely splicing glass optical fibers

Field-repair technique fuses glass fibers in flammable environment. Apparatus consists of v-groove vacuum chucks on manipulators, high-voltage dc power supply and tungsten electrodes, microscope to observe joint alignment and fusion, means of test transmission through joint. Apparatus is enclosed in gas tight bos filled with inert gas during fusion. About 2 feet of fiber end are necessary for splicing.

Korbelak, K.↗

Solar-heating and cooling demonstration project

Florida Solar Energy Center has retrofitted office building, approximately 5,000 square feet of area, with solar heating and air-conditioning. Information on operation, installation, controls, and hardware for system is contained in 164 page report. Document includes manufacturer's product literature and detailed drawings.

Source record↗

Solar energy meets 50 pecent of motel hot water needs--Key West, Florida

Final report describes domestic water preheat installed in 148 room motel. Equipment meets 50 percent of needs when motel is 100 percent occupied; equivalently, it supplies 100 percent of hot water when occupancy is 50 percent. System consists of 1,400 square feet of flat plate liquid solar collectors, storage tanks, pump, controller, and hardware.

Source record↗

Versatile modular scaffolds

Movable and fixed modular scaffolds can be tailored to most scaffolding needs by interconnecting only 4 basic structural elements: platforms, rails, vertical-support angles, and stiffener. Standard nuts and bolts are used to join elements, simplifying construction, and reducing costs. Scaffolds are rigid and can be made any length. They are stable on unlevel ground and can extend to well over 50 feet in height. Scaffolds allow for internal elevators and for wheels and air mounts so that same elements can be used for standing or movable scaffold.

Kerley, J.↗

Solar-heated bank-Marks Mississippi

Report describes air solar-energy collectors which supply 60 percent of space heating load for full-service bank. Contemporary structure supports 468 square feet of flat-plate arrays, and features onsite temperature and power measurement readouts. Air-flow collectors minimize problems experienced with conventional liquid solar equipment and eliminate need for heat exchanger for space heating.

Source record↗

Solar water-heating performance evaluation-San Diego, California

Report describes energy saved by replacing domestic, conventional natural gas heater with solar-energy subsystem in single-family residence near San Diego, California. Energy savings for 6 month test period averaged 1.089 million Btu. Collector array covered 65 square feet and supplied hot water to both 66-gallon solar storage tank and 40-gallon tank for domestic use. Natural gas supplied house's auxiliary energy.

Source record↗

Solar-energy heats a transportation test center--Pueblo, Colorado

Petroleum-base, thermal energy transport fluid circulating through 583 square feet of flat-plate solar collectors accumulates majority of energy for space heating and domestic hot-water of large Test Center. Report describes operation, maintenance, and performance of system which is suitable for warehouses and similar buildings. For test period from February 1979 to January 1980, solar-heating fraction was 31 percent, solar hot-water fraction 79 percent.

Source record↗

Single-family-residence solar heating--Carlsbad, New Mexico

Solar-heating and hot-water system includes 408 square feet of flat-plate air collectors, rock storage bin, energy transport system, air-to-water heat exchanger, controls, and hot-water preheat tank. Hot-air oil furnace supplies auxiliary space heating, and electricity powers air-handler blower and hot water preheat pump. For 12 month period, system provided 43 percent of space-heating and 53 percent of hot-water energy; net energy savings were 23.072 million Btu.

Source record↗

Solar-heated swimming school--Wilmington, Delaware

Report describes operation, installation, and performance of solar-energy system which provides alternative to natural gas pool heating. System is comprised of 2,500 square feet of liquid flat-plate collectors connected to 3,600 galloon; gallongalloon storage tank, with microcomputer-based controls. Extension of building incorporates vertical-wall, passive collection system which provides quarter of heated fresh air for office.

Source record↗

Solar space-heating system--Yosemite National Park, California

A 12 months performance of Visitors Center installation suffered from low insolation, high energy dissipation, and equipment breakdown. System has 980 square feet of liquid flat-plate collectors, water energy storage, 4-mode control, heat exchangers, pumps, and plumbing. Design expected system to supply over 50 percent of annual heating demand, but only 109 million Btu were conserved.

Source record↗

Parametric study of the Orbiter rollout using an approximate solution

An approximate solution to the motion of the Orbiter during rollout is used to perform a parametric study of the rollout distance required by the Orbiter. The study considers the maximum expected dispersions in the landing speed and the touchdown point. These dispersions are assumed to be correlated so that a fast landing occurs before the nominal touchdown point. The maximum rollout distance is required by the maximum landing speed with a 10 knot tailwind and the center of mass at the forward limit of its longitudinal travel. The maximum weight that can be stopped within 15,000 feet on a hot day at Kennedy Space Center is 248,800 pounds. The energy absorbed by the brakes would exceed the limit for reuse of the brakes.

Garland, B. J.↗

Solar process water heat for the IRIS images custom color photo lab

The solar facility located at a custom photo laboratory in Mill Valley, California is described. It was designed to provide 59 percent of the hot water requirements for developing photographic film and domestic hot water use. The design load is to provide 6 gallons of hot water per minute for 8 hours per working day at 100 F. It has 640 square feet of flat plate collectors and 360 gallons of hot water storage. The auxillary back up system is a conventional gas-fired water heater. Site and building description, subsystem description, as-built drawings, cost breakdown and analysis, performance analysis, lessons learned, and the operation and maintenance manual are presented.

Source record↗

Solar hot water system installed at Quality Inn, Key West, Florida

The solar energy hot water system installed in the Quality Inn, Key West, Florida, which consists of four buildings is described. Three buildings are low-rise, two-story buildings containing 100 rooms. The fourth is a four-story building with 48 rooms. The solar system was designed to provide approximately 50 percent of the energy required for the domestic hot water system. The solar system consists of approximately 1400 square feet of flat plate collector, two 500 gallon storage tanks, a circulating pump, and a controller. Operation of the system was begun in April 1978, and has continued to date with only three minor interruptions for pump repair. In the first year of operation, it was determined that the use of the solar facility resulted in forty percent fuel savings.

Source record↗