Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Direct detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Systems and methods for correcting optical reflectance measurements

We disclose measurement systems and methods for measuring analytes in target regions of samples that also include features overlying the target regions. The systems include: (a) a light source; (b) a detection system; (c) a set of at least first, second, and third light ports which transmit light from the light source to a sample and receive and direct light reflected from the sample to the detection system, generating a first set of data including information corresponding to both an internal target within the sample and features overlying the internal target, and a second set of data including information corresponding to features overlying the internal target; and (d) a processor configured to remove information characteristic of the overlying features from the first set of data using the first and second sets of data to produce corrected information representing the internal target.

Yang, Ye↗

Systems and Methods for Correcting Optical Reflectance Measurements

We disclose measurement systems and methods for measuring analytes in target regions of samples that also include features overlying the target regions. The systems include: (a) a light source; (b) a detection system; (c) a set of at least first, second, and third light ports which transmit light from the light source to a sample and receive and direct light reflected from the sample to the detection system, generating a first set of data including information corresponding to both an internal target within the sample and features overlying the internal target, and a second set of data including information corresponding to features overlying the internal target; and (d) a processor configured to remove information characteristic of the overlying features from the first set of data using the first and second sets of data to produce corrected information representing the internal target.

Yang, Ye↗

Computational Prediction of Infrasound Arrival Times and Directions from Stationary and Moving Impulsive Sources

This report addresses the need to predict infrasound signal arrival times and back azimuths at monitoring stations, enabling more focused and efficient searches within recorded waveform data. The primary challenge is estimating expected signal arrival windows for stationary and moving acoustic sources, such as chemical explosions, volcanic eruptions, meteoroids, and spacecraft re-entry events. To address this challenge, a reproducible methodology is described that uses simplified propagation speeds for boundary layer, tropospheric, stratospheric, and thermospheric atmospheric waveguides. While the Python source code itself is not freely available, this document provides detailed, step-by-step instructions, and equations enabling users to replicate and adapt the method independently. The method reliably predicts signal arrival intervals and back azimuths, thereby supporting rapid detection and accurate interpretation of infrasound events. Results demonstrate that this method effectively identifies plausible signal arrival intervals and directions, facilitating faster event detection and more reliable interpretation. This methodology directly supports atmospheric monitoring, planetary defense, and forensic analysis of explosive atmospheric events.

47 OTHER INSTRUMENTATION↗

Planetary Gearbox Fault Detection Using Vibration Separation Techniques

Studies were performed to demonstrate the capability to detect planetary gear and bearing faults in helicopter main-rotor transmissions. The work supported the Operations Support and Sustainment (OSST) program with the U.S. Army Aviation Applied Technology Directorate (AATD) and Bell Helicopter Textron. Vibration data from the OH-58C planetary system were collected on a healthy transmission as well as with various seeded-fault components. Planetary fault detection algorithms were used with the collected data to evaluate fault detection effectiveness. Planet gear tooth cracks and spalls were detectable using the vibration separation techniques. Sun gear tooth cracks were not discernibly detectable from the vibration separation process. Sun gear tooth spall defects were detectable. Ring gear tooth cracks were only clearly detectable by accelerometers located near the crack location or directly across from the crack. Enveloping provided an effective method for planet bearing inner- and outer-race spalling fault detection.

Lewicki, David G.↗

Reinforcement Learning for Anomaly Detection in Nuclear Power Plant Operation and Maintenance

In nuclear power plants (NPPs), timely identification of sensor and human errors is critical to ensure safe and efficient plant operations. Anomaly detection models can be employed for this task. However, traditional anomaly detection approaches may have high dependency on labeled datasets and struggle with adaptability in complex, dynamic environments. Reinforcement learning (RL) has demonstrated significant potential in fault diagnosis and anomaly detection; however, its application to anomaly detection in NPPs remains a relatively underexplored research direction. Hence, to address this gap, in this study, we present a novel physics-informed reinforcement learning model, PIRL-AD: Physics-Informed Reinforcement Learning for Anomaly Detection, that integrates domain knowledge from calorimetric equations into the RL framework for enhanced sensor and human error anomaly detection. We evaluate the performance of PIRL-AD against a non-physics informed RL benchmark and a support vector machine (SVM) on data collected from a forced flow loop testbed. Experimental results suggest that PIRL-AD outperforms other baselines on a range of anomalous datasets that include both sensor and human-induced anomalies across key performance metrics, statistically outperforming the RL and SVM benchmarks with respect to geometric mean (respectively, 92.96% vs. 91.06% vs. 83.01%) and F1-score (respectively, 89.23% vs. 86.98% vs. 77.01%). Furthermore, the findings suggest the potential of physics-integrated reinforcement learning models for enhanced anomaly detection performance in NPPs.

Reinforcement learning↗

Enzymatic Laser-Induced Graphene Biosensor for Electrochemical Sensing of the Herbicide Glyphosate

Glyphosate is a globally applied herbicide yet it has been relatively undetectable in-field samples outside of gold-standard techniques. Its presumed nontoxicity toward humans has been contested by the International Agency for Research on Cancer, while it has been detected in farmers’ urine, surface waters and crop residues. Rapid, on-site detection of glyphosate is hindered by lack of field-deployable and easy-to-use sensors that circumvent sample transportation to limited laboratories that possess the equipment needed for detection. Herein, the flavoenzyme, glycine oxidase, immobilized on platinum-decorated laser-induced graphene (LIG) is used for selective detection of glyphosate as it is a substrate for GlyOx. The LIG platform provides a scaffold for enzyme attachment while maintaining the electronic and surface properties of graphene. The sensor exhibits a linear range of 10–260 µm, detection limit of 3.03 µm, and sensitivity of 0.991 nA µm -1 . The sensor shows minimal interference from the commonly used herbicides and insecticides: atrazine, 2,4-dichlorophenoxyacetic acid, dicamba, parathion-methyl, paraoxon-methyl, malathion, chlorpyrifos, thiamethoxam, clothianidin, and imidacloprid. Sensor function is further tested in complex river water and crop residue fluids, which validate this platform as a scalable, direct-write, and selective method of glyphosate detection for herbicide mapping and food analysis.

47 OTHER INSTRUMENTATION↗

Rapid direct methods for enumeration of specific, active bacteria in water and biofilms

Conventional methods for detecting indicator and pathogenic bacteria in water may underestimate the actual population due to sublethal environmental injury, inability of the target bacteria to take up nutrients and other physiological factors which reduce bacterial culturability. Rapid and direct methods are needed to more accurately detect and enumerate active bacteria. Such a methodological advance would provide greater sensitivity in assessing the microbiological safety of water and food. The principle goal of this presentation is to describe novel approaches we have formulated for the rapid and simultaneous detection of bacteria plus the determination of their physiological activity in water and other environmental samples. The present version of our method involves the concentration of organisms by membrane filtration or immunomagnetic separation and combines an intracellular fluorochrome (CTC) for assessment of respiratory activity plus fluorescent-labelled antibody detection of specific bacteria. This approach has also been successfully used to demonstrate spatial and temporal heterogeneities of physiological activities in biofilms when coupled with cryosectioning. Candidate physiological stains include those capable of determining respiratory activity, membrane potential, membrane integrity, growth rate and cellular enzymatic activities. Results obtained thus far indicate that immunomagnetic separation can provide a high degree of sensitivity in the recovery of seeded target bacteria (Escherichia coli O157:H7) in water and hamburger. The captured and stained target bacteria are then enumerated by either conventional fluorescence microscopy or ChemScan(R), a new instrument that is very sensitive and rapid. The ChemScan(R) laser scanning instrument (Chemunex, Paris, France) provides the detection of individual fluorescently labelled bacterial cells using three emission channels in less than 5 min. A high degree of correlation has been demonstrated between results obtained with the ChemScan and traditional plate counts of mixed natural bacterial populations in water. The continuing evolution of these methods will be valuable in the rapid and accurate analysis of environmental samples.

Review, Tutorial↗

Accelerating fissile material detection with a neutron source

A system discriminating fissile material from nonfissile material wherein a digital data acquisition unit collects data at high rate, and processes large volumes of data directly to count neutrons from the unknown source and detect excess grouped neutrons to identify fission. The system includes a Poisson neutron generator for in-beam interrogation of a possible fissile neutron source and inducing neutron emission therefrom, and a DC power supply that exhibits electrical ripple of less than one part per million. A neutron count histogram and Poisson count distribution are overlaid to provide a visual indication of the difference in correlation of natural and induced emitted neutrons from the radiation source to characterize the neutron source as fissile material or non-fissile material.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Conceptual design of DIII-D experiments to diagnose the lifetime of spin polarized fuel

Abstract In magnetic fusion experiments, the cross sections for the D-T and D- 3 He fusion reactions are increased by as much as 50% if the fuel remains spin polarized parallel to the magnetic field. The goal of this study is to assess the feasibility of lifetime measurements of spin polarization, in magnetic fusion relevant conditions, on the DIII-D tokamak using relative changes in charged fusion product (CFP) loss measurements that depend upon the differential fusion cross section d σ /dΩ. Relative measurements that capture changes in the escaping CFP pitch, poloidal, and energy distributions are studied in two realistic TRANSP calculated plasma scenarios: (a) vector-polarized 3 He and D pellets are injected into a hot hydrogen plasma to produce thermonuclear reactions, and (b) a tensor-polarized deuterium pellet is injected into an L-mode hydrogen background plasma that includes unpolarized 3 He neutral beam injection. Ideal CFP signals in both scenarios show substantial pitch sensitivity to polarization for 14.7 MeV proton detection at a poloidal angle of − 56 ∘ (on the outer wall in the ion ∇ B direction), and strong sensitivity to polarization for 3.6 MeV alpha flux detection by an array of poloidal detectors. Energy-resolved measurements of 14.7 MeV protons are also sensitive to the degree of polarization for the − 56 ∘ port in the beam-plasma scenario. A realistic assessment of CFP signals in the thermonuclear scenario show count rates in the range of 2 × 10 4 cps for pitch-resolved proton detection and 2 × 10 5 cps for alpha flux measurements. Reduced chi-squared χ r 2 calculations show polarization lifetime measurements are feasible for either proton or alpha detection of both enhanced or suppressed polarization for the thermonuclear scenario. Measurements of gamma rays produced in the weak D + 3 He → γ + 5 Li branch complement the CFP measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Potentials for change detection using Seasat synthetic aperture radar data

The use of synthetic aperture radar (SAR) images for detecting change on the earth's surface is highly dependent on target orientation, azimuth angle, and sensor depression angle. SAR data can be used for change detection when consistency is maintained in radar wavelength, polarization, azimuth directions, and off-nadir depression angle. The interaction of these parameters and the imaged surface for change detection are shown in examples drawn from (1) Los Angeles, CA, (2) southern Florida, (3) Imperial Valley, CA, (4) a desert region west of Tucson, AZ, and (5) western Kansas. SAR imagery is used to emphasize the geometric form, and roughness, of the earth's surface. As changes in the roughness of the surface occur over time, temporal SAR images will indicate those differences. Several guidelines for change detection studies using imaging radar are derived from the examples.

Bryan, M. L.↗

Local Ultrasonic Resonance Spectroscopy of Lithium Metal Batteries for Aerospace Applications

As next-generation aircraft and vehicles continue to develop, so do their associated energy demands. Lithium metal batteries are a leading candidate to fulfill this energy requirement, but these batteries are prone to internal dendrite defects that can lead to catastrophic thermal runaway events. Current battery management systems are capable of mitigating such risks, but are unable to detect such defects until thermal runaway has already begun. Various nondestructive evaluation (NDE) techniques, particularly ultrasonic NDE, can directly monitor internal battery parameters giving them the potential to detect critical defects prior to catastrophic failure. However, most of the current battery NDE research has focused on improved battery state-of-charge (SOC) and stateof- health (SOH) monitoring with little emphasis on critical defect detection. Thus, a measurement technique sensitive to subtle battery defects is needed. In addition, the complex mechanics of ultrasound in porous, thin, multilayered batteries prompt the use of physics-based simulation to guide inspections. In this work, an ultrasonic NDE technique has been developed utilizing frequency domain analysis of local battery resonances to detect the presence of battery defects. This technique is a practical extension of local ultrasonic resonance spectroscopy (LURS) – which previously required non-contact laser ultrasonics – to measurements with piezoelectric contact and immersion scan transducers. To extend the technique to work with piezoelectric transducers, ultrasonic battery measurements were compared to a sans-battery calibration measurement. Then, a linear systems deconvolution was used to eliminate the transfer functions of extraneous factors such as the transducer and electronics, leaving only the frequency-dependent battery reflection coefficient. The LURS technique was first validated on stainless steel and aluminum plates, producing reflection coefficients in line with analytical and numerical finite element modeling (FEM) results. Functioning Li-metal pouch cells were then seeded with lithium chip defects prior to LURS measurements. The presence of these defects is shown to cause a measurable shift in the battery’s through-thickness local resonances. 2D, frequency-domain poroelastic models of ultrasonic propagation in a single-cell lithium metal pouch battery were created and corroborated these findings. Thus, this work has both extended and proven the feasibility of the LURS technique in the detection of local battery defects.

Ultrasound↗

Detection of a compact radio source near the center of a gravitational lens - Quasar image or galactic core

By use of a new, very sensitive interferometric system, a faint, compact radio source has been detected near the center of the galaxy that acts as the main part of a gravitational lens. This lens forms two previously discovered images of the quasar Q0957+561, which lies in the direction of the constellation Ursa Major. The newly detected source has a core smaller than 0.002 arc second in diameter with a flux density of 0.6 + or - 0.1 millijansky at the 13-centimeter wavelength of the radio observations. This source could be the predicted third image of the transparent gravitational lens, the central core of the galaxy, or some combination of the two. It is not yet possible to choose reliably between these alternatives.

Gorenstein, M. V.↗

Distribution of gas in the halo of the galaxy

Results are presented from a high-resolution, ultraviolet study of interstellar gas situated away from the plane of the Milky Way Galaxy, using the nuclei of Seyfert galaxies Mkn 509 and F9 as background probes. In these directions, low-velocity, galactic gas were detected as well as two extragalactic clouds, one probably associated with the Magellanic Stream and the other with Mkn 509. These data were combined with results from other lines of sight to show that the ultraviolet species extend about 10 kpc from the plane, assuming the high-latitude gas corotates with the galactic disk. Complimentary observations of the optical Ca II and Na I species suggests that these do not extend as far - perhaps 2 to 3 kpc from the plane. Further, the exceedingly complex velocity structure found only in Magellanic Cloud directions suggests that these sight-lines are not typical of high-latitude gas in general.

Blades, J. C.↗

Compatibility of a Diffractive Pupil and Coronagraphic Imaging

Detection and characterization of exo-earths require direct-imaging techniques that can deliver contrast ratios of 10(exp 10) at 100 milliarc-seconds or smaller angular separation. At the same time, astrometric data is required to measure planet masses and can help detect planets and constrain their orbital parameters. To minimize costs, a single space mission can be designed using a high efficiency coronograph to perform direct imaging and a diffractive pupil to calibrate wide-field distortions to enable high precision astrometric measurements. This paper reports the testing of a diffractive pupil on the high-contrast test bed at the NASA Ames Research Center to assess the compatibility of using a diffractive pupil with coronographic imaging systems. No diffractive contamination was found within our detectability limit of 2x10(exp -7) contrast outside a region of 12lambda/D and 2.5x10(exp -6) within a region spanning from 2 to 12lambda/D. Morphology of the image features suggests that no contamination exists even beyond the detectability limit specified or at smaller working angles. In the case that diffractive contamination is found beyond these stated levels, active wavefront control would be able to mitigate its intensity to 10(exp -7) or better contrast.

Bendek, Eduardo↗

The chemistry and mineralogy of Mars soil and dust

A single geological unit consisting of fine, apparently weathered soil material is covering large portions of the surface of Mars. This soil material has been thoroughly homogenized by global dust storms and it is plausible to assume that Mars dust is strongly correlated with it. The chemical-elemental composition of the soil was directly measured by the Viking Landers. Positive detection of Si, Al, Fe, Mg, Ca, Ti, S, Cl, and Br was achieved. Analyses of the SNC meteorites, a group of meteorites that has been suggested to be ejected Martian rocks, supply additional elemental-concentration data, broadening considerably the chemical data-base on the surface materials. A composition model for Mars soil, giving selected average elemental concentrations of major and trace elements, was recently suggested. It was constructed by combining the Viking Lander data, the SNC meteorite analyses, and other analyses. The mineralogy of the surface materials on Mars has not been directly measured yet. By use of various indirect approaches, including chemical correspondence to the surface analyses, spectral analogies, simulations of Viking Lander experiments, analyses of the SNC meteorites and various modeling efforts, the mineralogical composition was constrained to some extent. No direct analyses of soil reactivity have been done yet. Indirect evidence, mostly from the Viking biology experimental results, suggests that the soil probably has a slightly acidic reaction and is generally oxidized. Unambiguous identification of the Mars soil minerals by direct mineralogical analyses, and non-disturbed or in-situ measurements of the soil's reactivity, are of primary importance in future Mars research.

Banin, A.↗

Accelerating fissile material detection with a neutron source

A method of discriminating fissile material from non-fissile material with a digital data acquisition system that collects data at high rate, and processes large volumes of data directly to count neutrons from the unknown source and detect excess grouped neutrons to identify fission. The system includes a Poisson neutron generator for in-beam interrogation of a possible fissile neutron source and inducing neutron emission therefrom, and a DC power supply that exhibits electrical ripple of less than one part per million. A neutron count histogram and Poisson count distribution are overlaid to provide a visual indication of the difference in correlation of natural and induced emitted neutrons from the radiation source to characterize the neutron source as fissile material or non-fissile material.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Coherent Laser Instrument Would Measure Range and Velocity

A proposed instrument would project a narrow laser beam that would be frequency-modulated with a pseudorandom noise (PN) code for simultaneous measurement of range and velocity along the beam. The instrument performs these functions in a low mass, power, and volume package using a novel combination of established techniques. Originally intended as a low resource- footprint guidance sensor for descent and landing of small spacecraft onto Mars or small bodies (e.g., asteroids), the basic instrument concept also lends itself well to a similar application guiding aircraft (especially, small unmanned aircraft), and to such other applications as ranging of topographical features and measuring velocities of airborne light-scattering particles as wind indicators. Several key features of the instrument s design contribute to its favorable performance and resource-consumption characteristics. A laser beam is intrinsically much narrower (for the same exit aperture telescope or antenna) than a radar beam, eliminating the need to correct for the effect of sloping terrain over the beam width, as is the case with radar. Furthermore, the use of continuous-wave (CW), erbium-doped fiber lasers with excellent spectral purity (narrow line width) permits greater velocity resolution, while reducing the laser s power requirement compared to a more typical pulsed solid-state laser. The use of CW also takes proper advantage of the increased sensitivity of coherent detection, necessary in the first place for direct measurement of velocity using the Doppler effect. However, measuring range with a CW beam requires modulation to "tag" portions of it for time-of-flight determination; typically, the modulation consists of a PN code. A novel element of the instrument s design is the use of frequency modulation (FM) to accomplish both the PN-modulation and the Doppler-bias frequency shift necessary for signed velocity measurements. This permits the use of a single low-power waveguide electrooptic phase modulator, while simultaneously mitigating the effects of speckle as a noise source in the coherent detection.

Chang, Daniel↗

Summary of 2011 Direct and Nearby Lightning Strikes to Launch Complex 39B, Kennedy Space Center, Florida

A Lightning Protection System (LPS) was designed and built at Launch Complex 39B (LC39B), at the Kennedy Space Center (KSC), Florida in 2009. This LPS was instrumented with comprehensive meteorological and lightning data acquisition systems that were deployed from late 2010 until mid 2011. The first direct strikes to the LPS were recorded in March of 2011, when a limited number of sensors had been activated. The lightning instrumentation system detected a total of 70 nearby strokes and 19 direct strokes to the LPS, 2 of the 19 direct strokes to the LPS had two simultaneous ground attachment points (in both instances one channel terminated on the LPS and the other on the nearby ground). Additionally, there are more unaccounted nearby strokes seen on video records for which limited data was acquired either due to the distance of the stroke or the settings of the data acquisition system. Instrumentation deployment chronological milestones, a summary of lightning strikes (direct and nearby), high speed video frames, downconductor currents, and dH/dt and dE/dt typical waveforms for direct and nearby strokes are presented.

Mata, C.T.↗